Diabetes Technol Ther ; 25(9): 652-658, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37252734

RESUMO

Background: Safety and significant improvement in overall glycated hemoglobin (A1C) and percentage of time spent in (TIR), below (TBR), and above (TAR) glucose range were demonstrated in the pivotal trial of adolescents and adults using the MiniMed™ advanced hybrid closed-loop (AHCL) system with the adjunctive, calibration-required Guardian™ Sensor 3. The present study evaluated early outcomes of continued access study (CAS) participants who transitioned from the pivotal trial investigational system to the approved MiniMed™ 780G system with the non-adjunctive, calibration-free Guardian™ 4 Sensor (MM780G+G4S). Study data were presented alongside those of real-world MM780G+G4S users from Europe, the Middle East, and Africa. Methods: The CAS participants (N = 109, aged 7-17 years and N = 67, aged >17 years) used the MM780G+G4S for 3 months and data of real-world MM780G+G4S system users (N = 10,204 aged ≤15 years and N = 26,099 aged >15 years) were uploaded from September 22, 2021 to December 02, 2022. At least 10 days of real-world continuous glucose monitoring (CGM) data were required for analyses. Glycemic metrics, delivered insulin and system use/interactions underwent descriptive analyses. Results: Time in AHCL and CGM use were >90% for all groups. AHCL exits averaged 0.1/day and there were few blood glucose measurements (BGMs) (0.8/day-1.0/day). Adults in both cohorts met most consensus recommendations for glycemic targets. Pediatric groups met recommendations for %TIR and %TBR, although not those for mean glucose variability and %TAR, possibly due to low use of recommended glucose target (100 mg/dL) and active insulin time (2 h) settings (28.4% in the CAS cohort and 9.4% in the real-world cohort). The CAS pediatric and adult A1C were 7.2% ± 0.7% and 6.8% ± 0.7%, respectively, and there were no serious adverse events. Conclusions: Early clinical use of the MM780G+G4S was safe and involved minimal BGMs and AHCL exits. Consistent with real-world pediatric and adult use, outcomes were associated with achievement of recommended glycemic targets. Clinical Trial Registration number: NCT03959423.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Criança , Humanos , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Hemoglobinas Glicadas , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
3.
J Diabetes Sci Technol ; 17(4): 962-967, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35466707

RESUMO

BACKGROUND: Accuracy of a seventh-generation "G7" continuous glucose monitoring (CGM) system was evaluated in children and adolescents with type 1 diabetes (T1D). METHODS: Sensors were worn on the upper arm and abdomen. The CGM data were available from 127 of 132 participants, ages 7 to 17 years, across 10.5 days of use, various glucose concentration ranges, and various rates of glucose change for comparisons with temporally matched venous blood glucose measurements (YSI). Data were also available from 28 of 32 participants, ages 2 to 6 years, for whom capillary (fingerstick) blood provided comparator glucose values. Accuracy metrics included the mean absolute relative difference (MARD) between CGM and comparator glucose pairs, the proportion of CGM values within 15 mg/dL or 15% of comparator values <100 or ≥100 mg/dL, respectively, and the analogous %20/20 and %30/30 agreement rates. RESULTS: For participants aged 7 to 17, a total of 15 437 matched pairs were obtained from 122 arm-placed and 118 abdomen-placed sensors. For arm-placed sensors, the overall MARD was 8.1% and overall %15/15, %20/20, and %30/30 agreement rates were 88.8%, 95.3%, and 98.7%, respectively. For abdomen-placed sensors, the overall MARD was 9.0% and overall %15/15, %20/20, and %30/30 agreement rates were 86.0%, 92.9%, and 97.7%, respectively. Good accuracy was maintained across wear days, glucose ranges, and rates of glucose change. Among those aged 2 to 6, a total of 343 matched pairs provided an overall MARD of 9.3% and an overall %20/20 agreement rate of 91.5%. CONCLUSIONS: The G7 CGM placed on the arm or abdomen was accurate in children and adolescents with T1D. NCT#: NCT04794478.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Criança , Humanos , Abdome , Glicemia , Automonitorização da Glicemia , Reprodutibilidade dos Testes
4.
Diabetes Technol Ther ; 25(1): 1-12, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36472543

RESUMO

Objective: To evaluate safety and effectiveness of MiniMed™ 670G hybrid closed loop (HCL) in comparison with continuous subcutaneous insulin infusion (CSII) therapy for 6 months in persons with type 1 diabetes (T1D). Methods: Adults (aged 18-80 years), adolescents, and children (aged 2-17 years) with T1D who were using CSII therapy were enrolled and randomized (1:1) to 6 months of HCL intervention (n = 151, mean age of 39.9 ± 19.8 years) or CSII without continuous glucose monitoring (n = 151, 35.7 ± 18.4 years). Primary effectiveness endpoints included change in A1C for Group 1 (baseline A1C >8.0%), from baseline to the end of study, and difference in the end of study percentage of time spent below 70 mg/dL (%TBR <70 mg/dL) for Group 2 (baseline A1C ≤8.0%), to show superiority of HCL intervention versus control. Secondary effectiveness endpoints were change in A1C and %TBR <70 mg/dL for Group 2 and Group 1, respectively, to show noninferiority of HCL intervention versus control. Primary safety endpoints were rates of severe hypoglycemia and diabetic ketoacidosis (DKA). Results: Change in A1C and difference in %TBR <70 mg/dL for the overall group were significantly improved, in favor of HCL intervention. In addition, a significant mean (95% confidence interval) change in A1C was observed for both Group 1 (-0.8% [-1.1% to -0.4%], P < 0.0001) and Group 2 (-0.3% [-0.5% to -0.1%], P < 0.0001), in favor of HCL intervention. The same was observed for difference in %TBR <70 mg/dL for Group 1 (-2.2% [-3.6% to -0.9%]) and Group 2 (-4.9% [-6.3% to -3.6%]) (P < 0.0001 for both). There was one DKA event during run-in and six severe hypoglycemic events: two during run-in and four during study (HCL: n = 0 and CSII: n = 4 [6.08 per 100 patient-years]). Conclusions: This RCT demonstrates that the MiniMed 670G HCL safely and significantly improved A1C and %TBR <70 mg/dL compared with CSII control in persons with T1D, irrespective of baseline A1C level.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Adulto , Criança , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/tratamento farmacológico , Hemoglobinas Glicadas , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Pré-Escolar , Idoso , Idoso de 80 Anos ou mais
5.
Nat Med ; 28(10): 2092-2099, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36192552

RESUMO

Hyperglucagonemia contributes to hyperglycemia in patients with type 1 diabetes (T1D); however, novel therapeutics that block glucagon action could improve glycemic control. This phase 2 study evaluated the safety and efficacy of volagidemab, an antagonistic monoclonal glucagon receptor (GCGR) antibody, as an adjunct to insulin therapy in adults with T1D. The primary endpoint was change in daily insulin use at week 12. Secondary endpoints included changes in hemoglobin A1c (HbA1c) at week 13, in average daily blood glucose concentration and time within target range as assessed by continuous blood glucose monitoring (CGM) and seven-point glucose profile at week 12, incidence of hypoglycemic events, the proportion of subjects who achieve HbA1c reduction of ≥0.4%, volagidemab drug concentrations and incidence of anti-drug antibodies. Eligible participants (n = 79) were randomized to receive weekly subcutaneous injections of placebo, 35 mg volagidemab or 70 mg volagidemab. Volagidemab produced a reduction in total daily insulin use at week 12 (35 mg volagidemab: -7.59 units (U) (95% confidence interval (CI) -11.79, -3.39; P = 0.040 versus placebo); 70 mg volagidemab: -6.64 U (95% CI -10.99, -2.29; P = 0.084 versus placebo); placebo: -1.27 U (95% CI -5.4, 2.9)) without meeting the prespecified significance level (P < 0.025). At week 13, the placebo-corrected reduction in HbA1c percentage was -0.53 (95% CI -0.89 to -0.17, nominal P = 0.004) in the 35 mg volagidemab group and -0.49 (95% CI -0.85 to -0.12, nominal P = 0.010) in the 70 mg volagidemab group. No increase in hypoglycemia was observed with volagidemab therapy; however, increases in serum transaminases, low-density lipoprotein (LDL)-cholesterol and blood pressure were observed. Although the primary endpoint did not meet the prespecified significance level, we believe that the observed reduction in HbA1c and tolerable safety profile provide a rationale for further randomized studies to define the long-term efficacy and safety of volagidemab in patients with T1D.


Assuntos
Anticorpos Monoclonais Humanizados , Diabetes Mellitus Tipo 1 , Receptores de Glucagon , Adulto , Anticorpos Monoclonais Humanizados/efeitos adversos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Método Duplo-Cego , Glucagon , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/uso terapêutico , Humanos , Insulina/uso terapêutico , Lipoproteínas LDL/uso terapêutico , Receptores de Glucagon/antagonistas & inibidores , Transaminases/uso terapêutico , Resultado do Tratamento
6.
J Diabetes Sci Technol ; : 19322968221110622, 2022 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-35833638

RESUMO

BACKGROUND: Technosphere Insulin (TI) is an ultra-rapid-acting inhaled insulin. This study assessed the mean peak two-hour postprandial glucose concentration with the initial TI dose (dose 1) calculated per the current label (United State Prescribing Information) compared with a ~2× higher dose (dose 2). Secondary objectives were to evaluate hypoglycemia within the two-hour postprandial period, evaluate change in forced expiratory volume in one second (FEV1) before and after the two-hour postprandial period, and monitor for other adverse events. METHODS: Twenty patients with diabetes, on basal-bolus insulin therapy, received an initial dose 1 of TI followed by the higher dose 2, one to three days later. Subjects received an identical meal for both visits, and TI doses were administered immediately prior to the meal. RESULTS: The higher dose 2 provided significant reductions in mean postprandial glucose excursion (PPGE) in the two-hour postprandial period starting from 45 minutes (P = .008) to 120 minutes (P < .0001). Mean peak glucose was reduced from 228.6 to 179.3 mg/dL (P < .001) at two hours. Two hypoglycemic events (one level 1, one level 2) were observed in a single subject during the two-hour postprandial period with dose 2. There were no significant changes in FEV1 after either dose of TI. CONCLUSIONS: The higher dose 2 reduced PPGE versus the current label recommended dose 1 within the two-hour postprandial timeframe without any new safety concerns. When confirmed with a larger study, this higher TI dosing recommendation may help patients and clinicians minimize immediate postprandial hyperglycemia when titrating TI for prandial glucose control.

8.
Diabetes Technol Ther ; 24(6): 373-380, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35157505

RESUMO

Background: We evaluated the accuracy and safety of a seventh generation (G7) Dexcom continuous glucose monitor (CGM) during 10.5 days of use in adults with diabetes. Methods: Adults with either type 1 or type 2 diabetes (on intensive insulin therapy or not) participated at 12 investigational sites in the United States. In-clinic visits were conducted on days 1 or 2, 4 or 7, and on the second half of day 10 or the first half of day 11 for frequent comparisons with comparator blood glucose measurements obtained with the YSI 2300 Stat Plus glucose analyzer. Participants wore sensors concurrently on the upper arm and abdomen. Accuracy evaluation included the proportion of CGM values within 15% of comparator glucose levels >100 mg/dL or within 15 mg/dL of comparator levels ≤100 mg/dL (%15/15), along with the %20/20 and %30/30 agreement rates. The mean absolute relative difference (MARD) between temporally matched CGM and comparator values was also calculated. Results: Data from 316 participants (619 sensors, 77,774 matched pairs) were analyzed. For arm- and abdomen-placed sensors, overall MARDs were 8.2% and 9.1%, respectively. Overall %15/15, %20/20, and %30/30 agreement rates were 89.6%, 95.3%, and 98.8% for arm-placed sensors and were 85.5%, 93.2%, and 98.1% for abdomen-placed sensors. Across days of wear, glucose concentration ranges, and rates of change, %20/20 agreement rates varied by no more than 9% from the overall %20/20. No serious adverse events were reported. Conclusions: The G7 CGM provides accurate glucose readings with single-digit MARD with arm or abdomen placement in adults with diabetes. Clinicaltrials.gov: NCT04794478.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glucose , Humanos , Reprodutibilidade dos Testes
9.
J Diabetes Sci Technol ; 16(1): 70-77, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32954812

RESUMO

BACKGROUND: In this study, we evaluated the analytical performance of the second-generation factory-calibrated FreeStyle Libre Flash Glucose Monitoring (FreeStyle Libre 2) System compared to plasma venous blood glucose reference, Yellow Springs Instrument 2300 (YSI). METHODS: The study enrolled participants aged four and above with type 1 or type 2 diabetes at seven sites in the United States. Adult participants (18+ years) participated in three in-clinic sessions and pediatric participants (4-17 years) participated in up to two in-clinic sessions stratified to provide data for days 1, 2, 3, 7, 8, 9, 12, 13, or 14 of sensor wear. Participants aged 11+ underwent supervised glycemic manipulation during in-clinic sessions to achieve glucose levels across the measurement range of the System. Performance evaluation included accuracy measures such as the proportion of continuous glucose monitoring (CGM) values that were within ±20% or ±20 mg/dL of reference glucose values, and bias measures such as the mean absolute relative difference (MARD) between CGM and reference values. RESULTS: Data from the 144 adults and 129 pediatric participants were analyzed. Percent of sensor results within ±20%/20 mg/dL of YSI reference were 93.2% and 92.1%, and MARD was 9.2% and 9.7% for the adults and pediatric participants, respectively. The System performed well in the hypoglycemic range, with 94.3% of the results for the adult population and 96.1% of the data for pediatric population being within 15 mg/dL of the YSI reference. The time lag was 2.4 ± 4.6 minutes for adults and 2.1 ± 5.0 minutes for pediatrics. CONCLUSIONS: The System demonstrated improved analytical accuracy performance across the dynamic range during the 14-day sensor wear period as compared to the previous-generation device.NCT#: NCT03607448 and NCT03820050.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Pediatria , Adulto , Idoso , Algoritmos , Glicemia , Automonitorização da Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glucose , Humanos , Reprodutibilidade dos Testes
10.
Diabetes Technol Ther ; 24(3): 178-189, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34694909

RESUMO

Introduction: This trial assessed safety and effectiveness of an advanced hybrid closed-loop (AHCL) system with automated basal (Auto Basal) and automated bolus correction (Auto Correction) in adolescents and adults with type 1 diabetes (T1D). Materials and Methods: This multicenter single-arm study involved an intent-to-treat population of 157 individuals (39 adolescents aged 14-21 years and 118 adults aged ≥22-75 years) with T1D. Study participants used the MiniMed™ AHCL system during a baseline run-in period in which sensor-augmented pump +/- predictive low glucose management or Auto Basal was enabled for ∼14 days. Thereafter, Auto Basal and Auto Correction were enabled for a study phase (∼90 days), with glucose target set to 100 or 120 mg/dL for ∼45 days, followed by the other target for ∼45 days. Study endpoints included safety events and change in mean A1C, time in range (TIR, 70-180 mg/dL) and time below range (TBR, <70 mg/dL). Run-in and study phase values were compared using Wilcoxon signed-rank test or paired t-test. Results: Overall group time spent in closed loop averaged 94.9% ± 5.4% and involved only 1.2 ± 0.8 exits per week. Compared with run-in, AHCL reduced A1C from 7.5% ± 0.8% to 7.0% ± 0.5% (<0.001, Wilcoxon signed-rank test, n = 155), TIR increased from 68.8% ± 10.5% to 74.5% ± 6.9% (<0.001, Wilcoxon signed-rank test), and TBR reduced from 3.3% ± 2.9% to 2.3% ± 1.7% (<0.001, Wilcoxon signed-rank test). Similar benefits to glycemia were observed for each age group and were more pronounced for the nighttime (12 AM-6 AM). The 100 mg/dL target increased TIR to 75.4% (n = 155), which was further optimized at a lower active insulin time (AIT) setting (i.e., 2 h), without increasing TBR. There were no severe hypoglycemic or diabetic ketoacidosis events during the study phase. Conclusions: These findings show that the MiniMed AHCL system is safe and allows for achievement of recommended glycemic targets in adolescents and adults with T1D. Adjustments in target and AIT settings may further optimize glycemia and improve user experience. Clinical Trial Registration number: NCT03959423.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Idoso , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Pessoa de Meia-Idade , Adulto Jovem
11.
Diabetes Technol Ther ; 24(2): 84-92, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34515521

RESUMO

Background: Use of continuous glucose monitoring (CGM) systems is being rapidly adopted as standard of care for insulin-requiring patients with diabetes. The PROMISE study (NCT03808376) evaluated the accuracy and safety of the next-generation implantable Eversense CGM system for up to 180 days. Methods: This was a prospective multicenter study involving 181 subjects with diabetes at 8 USA sites. All subjects were inserted with a primary sensor. Ninety-six subjects had a second sensor, either an identical sensor or a modified sensor (sacrificial boronic acid [SBA]), inserted in their other arm (53 and 43 subjects, respectively). Accuracy was evaluated by comparing CGM to YSI 2300 glucose analyzer (Yellow Springs Instrument [YSI]) values during 10 clinic visits (day 1-180). Confirmed event detection rates, calibration stability, sensor survival, and serious adverse events (SAEs) were evaluated. Results: For primary sensors, the percent CGM readings within 20%/20% of YSI values was 92.9%; overall mean absolute relative difference (MARD) was 9.1%. The confirmed alert detection rate at 70 mg/dL was 93% and at 180 mg/dL was 99%. The median percentage of time for one calibration per day was 56%. Sixty-five percent of the primary sensors survived to 180 days. For the SBA sensors, the percent CGM readings within 20%/20% of YSI values was 93.9%; overall MARD was 8.5%. The confirmed alert detection rate at 70 mg/dL was 94% and at 180 mg/dL was 99%. The median percentage of time for one calibration per day was 63%. Ninety percent of the SBA sensors survived to 180 days. No device- or insertion/removal procedure-related SAEs were reported. Conclusion: These data show the next-generation Eversense CGM system had sustained accuracy and safety up to 180 days, with an improved calibration scheme and survival, using the primary or SBA sensors.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes
12.
Artigo em Inglês | MEDLINE | ID: mdl-34620618

RESUMO

INTRODUCTION: To prevent medical sequelae of severe hypoglycemic emergencies, prompt and reliable rescue intervention is critically important. A ready-to-use, liquid stable glucagon, administered subcutaneously by glucagon autoinjector (GAI), Gvoke HypoPen (glucagon injection; Xeris Pharmaceuticals), was evaluated for rescue treatment of severe hypoglycemia. RESEARCH DESIGN AND METHODS: Two phase III, randomized, controlled, blinded, non-inferiority crossover studies were conducted in 161 adults with type 1 diabetes to compare 1 mg doses of GAI versus glucagon emergency kit (GEK) for treating insulin-induced severe hypoglycemia. Efficacy was evaluated as either a return of plasma glucose to >70 mg/dL (3.9 mmol/L) or increase ≥20 mg/dL (1.1 mmol/L) from a baseline glucose of <50 mg/dL (2.9 mmol/L), within 30 min of dosing. RESULTS: For successful plasma glucose recovery within 30 min, treatment with GAI was non-inferior to GEK. Treatment with GAI was non-inferior to GEK for a plasma glucose >70 mg/dL (3.9 mmol/L) or neuroglycopenic symptom relief within 30 min. From administration of glucagon, the mean time to achieve plasma glucose >70 mg/dL (3.9 mmol/L) or increase ≥20 mg/dL (1.1 mmol/L) was 13.8±5.6 min for GAI and 10.0±3.6 min for GEK. This mean time does not account for the significantly shorter (p<0.0001) drug preparation and administration time for GAI (27.3±19.7 s) versus GEK (97.2±45.1 s). The incidence of treatment emergent adverse events was comparable in both groups. CONCLUSIONS: A ready-to-use GAI was non-inferior to GEK, with a similar tolerability profile. GAI is an effective, safe, and well-tolerated rescue treatment for severe hypoglycemia and is a viable alternative to GEK. TRIAL REGISTRATION NUMBERS: NCT02656069 and NCT03439072.


Assuntos
Glucagon , Hipoglicemia , Glicemia , Estudos Cross-Over , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , Insulina
13.
Nat Genet ; 53(9): 1300-1310, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34475573

RESUMO

Trait-associated genetic variants affect complex phenotypes primarily via regulatory mechanisms on the transcriptome. To investigate the genetics of gene expression, we performed cis- and trans-expression quantitative trait locus (eQTL) analyses using blood-derived expression from 31,684 individuals through the eQTLGen Consortium. We detected cis-eQTL for 88% of genes, and these were replicable in numerous tissues. Distal trans-eQTL (detected for 37% of 10,317 trait-associated variants tested) showed lower replication rates, partially due to low replication power and confounding by cell type composition. However, replication analyses in single-cell RNA-seq data prioritized intracellular trans-eQTL. Trans-eQTL exerted their effects via several mechanisms, primarily through regulation by transcription factors. Expression of 13% of the genes correlated with polygenic scores for 1,263 phenotypes, pinpointing potential drivers for those traits. In summary, this work represents a large eQTL resource, and its results serve as a starting point for in-depth interpretation of complex phenotypes.


Assuntos
Proteínas Sanguíneas/genética , Regulação da Expressão Gênica/genética , Locos de Características Quantitativas/genética , Estudo de Associação Genômica Ampla , Humanos , Herança Multifatorial/genética , Polimorfismo de Nucleotídeo Único/genética , Transcriptoma/genética
14.
Clin Transl Sci ; 14(3): 1176-1184, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33465273

RESUMO

VM202 is a plasmid DNA encoding two isoforms of hepatocyte growth factor (HGF). A previous phase II study in subjects with painful diabetic peripheral neuropathy (DPN) showed significant reductions in pain. A phase III study was conducted to evaluate the safety and efficacy of VM202 in DPN. The trial was conducted in two parts, one for 9 months (DPN 3-1) with 500 subjects (VM202: 336 subjects; and placebo: 164) and a preplanned subset of 101 subjects (VM202: 65 subjects; and placebo: 36) with a noninterventional extension to 12 months (DPN 3-1b). VM202 or placebo was administered to calf muscles on days 0 and 14, and on days 90 and 104. The primary end point in DPN 3-1 was change from baseline in the mean 24-h Numerical Rating Scale (NRS) pain score. In DPN 3-1b, the primary end point was safety, whereas the secondary efficacy end point was change in the mean pain score. VM202 was well-tolerated in both studies without significant adverse events. VM202 failed to meet its efficacy end points in DPN 3-1. In DPN 3-1b, however, VM202 showed significant and clinically meaningful pain reduction versus placebo. Pain reduction in DPN 3-1b was even greater in subjects not receiving gabapentin or pregabalin, confirming an observation noted in the phase II study. In DPN 3-1b, symptomatic relief was maintained for 8 months after the last injection suggesting that VM202 treatment might change disease progression. Despite the perplexing discrepancy between the two studies, the safety and long-lasting pain-relieving effects of VM202 observed in DPN 3-1b warrant another rigorous phase III study. Study Highlights WHAT IS THE CURRENT KNOWLEDGE ON THE TOPIC? Current therapies for painful diabetic peripheral neuropathy (DPN) are palliative and do not target the underlying mechanisms. Moreover, symptomatic relief is often limited with existing neuropathic pain drugs. Thus, there is a great medical need for safer and effective treatments for DPN. WHAT QUESTION DID THIS STUDY ADDRESS? Can nonviral gene delivery of hepatocyte growth factor reduce pain in patients with DPN and potentially modify progression of the disorder? WHAT DOES THIS STUDY ADD TO OUR KNOWLEDGE? Nonviral gene therapy can be used safely and practically to treat DPN. HOW MIGHT THIS CHANGE CLINICAL PHARMACOLOGY OR TRANSLATIONAL SCIENCE? As the first gene medicine to enter advanced clinical trials for the treatment of DPN, this study provides the proof of concept of an entirely new potential approach to the disorder.


Assuntos
Neuropatias Diabéticas/terapia , Terapia Genética/métodos , Fator de Crescimento de Hepatócito/genética , Neuralgia/terapia , Plasmídeos/administração & dosagem , Idoso , Neuropatias Diabéticas/complicações , Neuropatias Diabéticas/genética , Método Duplo-Cego , Feminino , Humanos , Injeções Intramusculares , Masculino , Pessoa de Meia-Idade , Neuralgia/diagnóstico , Neuralgia/genética , Medição da Dor/estatística & dados numéricos , Placebos/administração & dosagem , Placebos/efeitos adversos , Plasmídeos/efeitos adversos , Plasmídeos/genética , Resultado do Tratamento
15.
Diabetes Technol Ther ; 23(3): 187-194, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32940537

RESUMO

Background: Automated insulin delivery (AID) systems have demonstrated improvements in time-in-range (TIR, blood glucose 70-180 mg/dL) without increasing hypoglycemia. Testing a closed-loop system in an inpatient environment with supervised challenges allows for initial evaluation of performance and safety of the system. Methods: Adults with type 1 diabetes (T1D) were enrolled into two similar studies (n = 10 per study), with 3-day inpatient analysis periods. Participants tested a Lilly hybrid closed-loop (HCL) system comprising an investigational insulin pump, insulin lispro, a pump-embedded model predictive control algorithm, a continuous glucose monitor (CGM), and an external dedicated controller. Each protocol included meal-related and exercise challenges to simulate real-world diabetes self-management errors. Only study staff interacted with the HCL system. Performance was assessed using standard CGM metrics overall and within prespecified periods. Results: Participants (25% male) had mean ± standard deviation (SD) age 44.7 ± 14.2 years, T1D duration 30.2 ± 11.1 years, A1C 7.2% ± 0.8%, and insulin usage 0.53 ± 0.21 U/(kg·day). Percentage TIR 70-180 mg/dL (mean ± SD) was 81.2 ± 8.4 overall, 85.2 ± 8.1 outside of challenge periods, 97.3 ± 5.3 during the nocturnal periods, and 74.5 ± 16.2 for the postprandial periods. During challenge periods, percentage TIR for the overbolus challenge was 65.4 ± 29.2 and that for the delayed bolus challenge was 57.1 ± 25.1. No adverse events (AEs), serious AEs, or unanticipated adverse device events occurred while participants were using the HCL system. Conclusions: In participants with T1D, Lilly AID system demonstrated expected algorithm performance and safety with satisfactory glycemic outcomes overall and in response to simulated diabetes management challenges. Additional studies in less supervised conditions and with broader patient populations are warranted. ClinicalTrials.gov Registration number NCT03743285, NCT03849612.


Assuntos
Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Pâncreas Artificial , Adulto , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Estudos de Viabilidade , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade
16.
Artigo em Inglês | MEDLINE | ID: mdl-32303532

RESUMO

INTRODUCTION: This prospective observational study sought to establish the glycemic, physiological and dietary demands of strenuous exercise training as part of a 9-day performance camp in a professional cycling team with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: Sixteen male professional cyclists with T1D on multiple daily injections (age: 27±4 years; duration of T1D: 11±5 years; body mass index: 22±2 kg/m2; glycated hemoglobin: 7%±1% (50±6 mmol/mol); maximum rate of oxygen consumption: 73±4 mL/kg/min) performed road cycle sessions (50%-90% of the anaerobic threshold, duration 1-6 hours) over 9 consecutive days. Glycemic (Dexcom G6), nutrition and physiological data were collected throughout. Glycemic data were stratified into predefined glycemic ranges and mapped alongside exercise physiology and nutritional parameters, as well as split into daytime and night-time phases for comparative analysis. Data were assessed by means of analysis of variance and paired t-tests. A p value of ≤0.05 (two-tailed) was statistically significant. RESULTS: Higher levels of antecedent hypoglycemia in the nocturnal hours were associated with greater time spent in next-day hypoglycemia overall (p=0.003) and during exercise (p=0.019). Occurrence of nocturnal hypoglycemia was associated with over three times the risk of next-day hypoglycemia (p<0.001) and a twofold risk of low glucose during cycling (p<0.001). Moreover, there was trend for a greater amount of time spent in mild hypoglycemia during the night compared with daytime hours (p=0.080). CONCLUSION: The higher prevalence of nocturnal hypoglycemia was associated with an increased risk of next-day hypoglycemia, which extended to cycle training sessions. These data highlight the potential need for additional prebed carbohydrates and/or insulin dose reduction strategies around exercise training in professional cyclists with T1D. TRIAL REGISTRATION NUMBER: DRKS00019923.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Glicemia , Diabetes Mellitus Tipo 1/epidemiologia , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/epidemiologia , Hipoglicemiantes , Masculino , Adulto Jovem
18.
Diabetes Care ; 43(5): 1142-1145, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32179510

RESUMO

OBJECTIVE: To investigate factors related to glycemic management among members of a professional cycling team with type 1 diabetes over a 7-day Union Cycliste Internationale World Tour stage race. RESEARCH DESIGN AND METHODS: An observational evaluation of possible factors related to glycemic management and performance in six male professional cyclists with type 1 diabetes (HbA1c 6.4 ± 0.6%) during the 2019 Tour of California. RESULTS: In-ride time spent in euglycemia (3.9-10.0 mmol/L glucose) was 63 ± 11%, with a low percentage of time spent in level 1 (3.0-3.9 mmol/L; 0 ± 1% of time) and level 2 (<3.0 mmol/L; 0 ± 0% of time) hypoglycemia over the 7-day race. Riders spent 25 ± 9% of time in level 1 (10.1-13.9 mmol/L) and 11 ± 9% in level 2 (>13.9 mmol/L) hyperglycemia during races. Bolus insulin use was uncommon during races, despite high carbohydrate intake (76 ± 23 g ⋅ h-1). Overnight, the riders spent progressively more time in hypoglycemia from day 1 (6 ± 12% in level 1 and 0 ± 0% in level 2) to day 7 (12 ± 12% in level 1 and 2 ± 4% in level 2) (χ2[1] > 4.78, P < 0.05). CONCLUSIONS: Professional cyclists with type 1 diabetes have excellent in-race glycemia, but significant hypoglycemia during recovery overnight, throughout a 7-day stage race.


Assuntos
Atletas , Ciclismo/fisiologia , Glicemia/metabolismo , Diabetes Mellitus Tipo 1/sangue , Controle Glicêmico , Adulto , Automonitorização da Glicemia , California , Comportamento Competitivo , Diabetes Mellitus Tipo 1/tratamento farmacológico , Controle Glicêmico/normas , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Autogestão/métodos , Fatores de Tempo
19.
Sci Rep ; 9(1): 15192, 2019 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-31645637

RESUMO

Previous research has shown that genes play a substantial role in determining a person's susceptibility to age-related hearing impairment. The existing studies on this subject have different results, which may be caused by difficulties in determining the phenotype or the limited number of participants involved. Here, we have gathered the largest sample to date (discovery n = 9,675; replication n = 10,963; validation n = 356,141), and examined phenotypes that represented low/mid and high frequency hearing loss on the pure tone audiogram. We identified 7 loci that were either replicated and/or validated, of which 5 loci are novel in hearing. Especially the ILDR1 gene is a high profile candidate, as it contains our top SNP, is a known hearing loss gene, has been linked to age-related hearing impairment before, and in addition is preferentially expressed within hair cells of the inner ear. By verifying all previously published SNPs, we can present a paper that combines all new and existing findings to date, giving a complete overview of the genetic architecture of age-related hearing impairment. This is of importance as age-related hearing impairment is highly prevalent in our ageing society and represents a large socio-economic burden.


Assuntos
Envelhecimento/genética , Loci Gênicos , Predisposição Genética para Doença , Estudo de Associação Genômica Ampla , Perda Auditiva/genética , Animais , Vias Auditivas/metabolismo , Feminino , Regulação da Expressão Gênica , Humanos , Masculino , Camundongos , Pessoa de Meia-Idade , Anotação de Sequência Molecular , Fenótipo , Reprodutibilidade dos Testes
20.
J Infect Dis ; 220(3): 411-419, 2019 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-31535143

RESUMO

BACKGROUND: A conditionally replication-defective human cytomegalovirus (CMV) vaccine (V160) derived from AD169 and genetically engineered to express CMV pentameric complex (gH/gL/pUL128/pUL130/pUL131) was developed and evaluated for phase 1 vaccine safety and immunogenicity in CMV-seronegative and CMV-seropositive adults. METHODS: Subjects received 3 doses of V160 or placebo on day 1, month 1, and month 6. Four vaccine dose levels, formulated with or without aluminum phosphate adjuvant, were evaluated. Injection-site and systemic adverse events (AEs) and vaccine viral shedding were monitored. CMV-specific cellular and humoral responses were measured by interferon-gamma ELISPOT and virus neutralization assay up to 12 months after last dose. RESULTS: V160 was generally well-tolerated, with no serious AEs observed. Transient, mild-to-moderate injection-site and systemic AEs were reported more frequently in vaccinated subjects than placebo. Vaccine viral shedding was not detected in any subject, confirming the nonreplicating feature of V160. Robust neutralizing antibody titers were elicited and maintained through 12 months postvaccination. Cellular responses to structural and nonstructural viral proteins were observed, indicating de novo expression of viral genes postvaccination. CONCLUSIONS: V160 displayed an acceptable safety profile. Levels of neutralizing antibodies and T-cell responses in CMV-seronegative subjects were within ranges observed following natural CMV infection. CLINICAL TRIAL REGISTRATION: . NCT01986010.


Assuntos
Infecções por Citomegalovirus/imunologia , Vacinas contra Citomegalovirus/imunologia , Citomegalovirus/imunologia , Replicação Viral/imunologia , Adjuvantes Imunológicos/administração & dosagem , Adolescente , Adulto , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , Método Duplo-Cego , ELISPOT/métodos , Feminino , Humanos , Imunidade Celular/imunologia , Imunidade Humoral/imunologia , Imunização/métodos , Masculino , Pessoa de Meia-Idade , Linfócitos T/imunologia , Vacinação/métodos , Eliminação de Partículas Virais/imunologia , Adulto Jovem