Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 194
Filtrar
1.
J Endourol ; 38(5): 505-512, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38482817

RESUMO

Background: The narrower focal zone (FZ) size of modern lithotripter was considered as one of the factors that resulted in suboptimal treatment result of extracorporeal shockwave lithotripsy (SWL). Therefore, we investigate the efficacy and safety of standard narrow or extended (FZ) sizes in SWL for patients with renal stones. Materials and Methods: In this prospective study conducted between April 2018 and October 2022, patients with renal stones were randomized to receive SWL with either standard or extended FZ. Treatment was delivered using a Modulith SLX-F2 lithotripter with a maximum of 3000 shocks at 1.5 Hz. The primary outcome was treatment success 12 weeks after a single SWL session, defined as the absence of a stone or stone fragment <4 mm on computed tomography. Secondary outcomes included the incidence of perinephric hematoma, stone-free rate (SFR), and changes in the urinary levels of acute renal injury markers. Results: A total of 320 patients were recruited, and 276 patients were randomized into the two groups. The two groups had similar baseline parameters. The treatment success rate was significantly better for standard FZ (74.3%) than the extended FZ group (59.3%) (p = 0.009). Standard FZ also had a significantly better SFR (Grade-A, 36.8% vs 23.0%, p = 0.013) and less pain after treatment. Both groups had similar perinephric hematoma formation rates, unplanned hospital admission rates, and changes in urinary acute renal injury markers. Conclusions: The standard narrow FZ has better treatment efficacy and similar safety compared with the extended FZ during SWL for renal stones. This clinical trial has been registered in the public domain (CCRBCTR) under trial number CUHK_CCRB00510.


Assuntos
Cálculos Renais , Litotripsia , Humanos , Cálculos Renais/terapia , Litotripsia/efeitos adversos , Litotripsia/métodos , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto , Rim , Idoso , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/terapia
2.
BJR Case Rep ; 10(1): uaad008, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38352256

RESUMO

Kawasaki disease is the most common vasculitis causing acquired coronary artery aneurysm (CAA) and affects mostly children. Computed tomography coronary angiography (CTCA) has unique diagnostic and prognostic values in cases of giant CAA. Here, we report technical challenges encountered when performed CTCA for a case of Kawasaki disease complicated with giant CAA. In particular, there was significant flow alteration caused by the giant CAA(s) causing suboptimal enhancement when the standard protocol was applied. We share our experience in optimizing the scan and propose the use of either manual bolus tracking or test bolus technique in similar scenarios, as well as multidisciplinary approach to optimize patient preparation.

4.
Diagnostics (Basel) ; 13(23)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38066821

RESUMO

Radiomics has the potential to aid prostate cancer (PC) diagnoses and prediction by analyzing and modeling quantitative features extracted from clinical imaging. However, its reliability has been a concern, possibly due to its high-dimensional nature. This study aims to quantitatively investigate the impact of randomly generated irrelevant features on MRI radiomics feature selection, modeling, and performance by progressively adding randomly generated features. Two multiparametric-MRI radiomics PC datasets were used (dataset 1 (n = 260), dataset 2 (n = 100)). The endpoint was to differentiate pathology-confirmed clinically significant (Gleason score (GS) ≥ 7) from insignificant (GS < 7) PC. Random features were generated at 12 levels with a 10% increment from 0% to 100% and an additional 5%. Three feature selection algorithms and two classifiers were used to build the models. The area under the curve and accuracy were used to evaluate the model's performance. Feature importance was calculated to assess features' contributions to the models. The metrics of each model were compared using an ANOVA test with a Bonferroni correction. A slight tendency to select more random features with the increasing number of random features introduced to the datasets was observed. However, the performance of the radiomics-built models was not significantly affected, which was partially due to the higher contribution of radiomics features toward the models compared to the random features. These reliability effects also vary among datasets. In conclusion, while the inclusion of additional random features may still slightly impact the performance of the feature selection, it may not have a substantial impact on the MRI radiomics model performance.

5.
Brain Connect ; 13(9): 553-562, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37551987

RESUMO

Introduction: The diagnosis of Alzheimer's disease (AD) requires the presence of amyloid and tau pathology, but it remains unclear how they affect the structural network in the pre-clinical stage. We aimed to assess differences in topological properties in cognitively normal (CN) individuals with varying levels of amyloid and tau pathology, as well as their association with AD pathology burden. Methods: A total of 68 CN individuals were included and stratified by normal/abnormal (-/+) amyloid (A) and tau (T) status based on positron emission tomography results, yielding three groups: A-T- (n = 19), A+T- (n = 28), and A+T+ (n = 21). Topological properties were measured from structural connectivity. Group differences and correlations with A and T were evaluated. Results: Compared with the A-T- group, the A+T+ group exhibited changes in the structural network topology. At the global level, higher assortativity was shown in the A+T+ group and was correlated with greater tau burden (r = 0.29, p = 0.02), while no difference in global efficiency was found across the three groups. At the local level, the A+T+ group showed disrupted topological properties in the left hippocampus compared with the A-T- group, characterized by lower local efficiency (p < 0.01) and a lower clustering coefficient (p = 0.014). Conclusions: The increased linkage in the higher level architecture of the white matter network reflected by assortativity may indicate increased brain resilience in the early pathological state. Our results encourage further investigation of the topological properties of the structural network in pre-clinical AD.


Assuntos
Doença de Alzheimer , Substância Branca , Humanos , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imageamento por Ressonância Magnética , Substância Branca/patologia , Hipocampo , Tomografia por Emissão de Pósitrons/métodos
6.
Br J Ophthalmol ; 107(12): 1920-1924, 2023 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36288914

RESUMO

BACKGROUND: Oral corticosteroid remains the first-line treatment of IgG4-related ophthalmic disease, but steroid-dependence is common and serious. Factors associated with steroid dependence and relapse have to be further explored. STUDY POPULATION: A city-wide, biopsy-proven, Chinese cohort. METHODS: Retrospective, masked review of medical records, orbital images and histopathology reports. RESULTS: There were 101 patients with at least 24-month follow-up. Up to 82% (82/101) received oral corticosteroid as first-line treatments, and 7 of them received also concomitant steroid-sparing agents (SSA)/biological agents as primary treatment. There was 61% (50/82) of patients required long-term corticosteroid (alone=23, with SSA=27) after 1.9±0.7 (range 1-5) relapses. When compared with the 21% (17/82) of patients who tapered corticosteroid successfully for 24 months, steroid dependence was associated with elevated baseline serum IgG4 level (94% vs 65%, p<0.01) and Mikulicz syndrome (46% vs 18%, p<0.05). Up to 13% (11/82) of patients tolerated residual disease after tapering off corticosteroid. There was 17% (17/101) of patients did not require any medications after biopsies. They were more likely to have debulking surgeries (71% vs 40%, p<0.05), discrete orbital lesions (65% vs 26%, p<0.05), normal baseline serum IgG4 level (24% vs 6%, p<0.05) and no Mikulicz syndrome (94% vs 61%, p<0.05). CONCLUSION: In this cohort, 60% of patients required long-term maintenance oral corticosteroid. Elevated pretreatment serum IgG4 level and Mikulicz syndrome were associated with steroid dependence. Debulking surgery is an alternative for a subgroup of patients with discrete orbital lesions, normal baseline IgG4 level and no Mikulicz syndrome.


Assuntos
Doença Relacionada a Imunoglobulina G4 , Recidiva Local de Neoplasia , Humanos , Estudos de Coortes , Estudos Retrospectivos , Glucocorticoides/uso terapêutico , Imunoglobulina G , Resultado do Tratamento , Esteroides
7.
Med Phys ; 50(2): 958-969, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36251320

RESUMO

PURPOSE: Determination of reliable change of radiomics feature over time is essential and vital in delta-radiomics, but has not yet been rigorously examined. This study attempts to propose a methodological approach using reliable change index (RCI), a statistical metric to determine the reliability of quantitative biomarker changes by accounting for the baseline measurement standard error, in delta-radiomics. The use of RCI was demonstrated with the MRI data acquired from a group of prostate cancer (PCa) patients treated by 1.5 T MRI-guided radiotherapy (MRgRT). METHODS: Fifty consecutive PCa patients who underwent five-fractionated MRgRT were retrospectively included, and 1023 radiomics features were extracted from the clinical target volume (CTV) and planning target volume (PTV). The two MRI datasets acquired at the first fraction (MRI11 and MRI21) were used to calculate the baseline feature reliability against image acquisition using intraclass correlation coefficient (ICC). The RCI was constructed based on the baseline feature measurement standard deviation, ICC, and feature value differences at two time points between the fifth (MRI51) and the first fraction MRI (MRI11). The reliable change of features was determined in each patient only if the calculated RCI was over 1.96 or smaller than -1.96. The feature changes between MRI51 and MRI11 were correlated to two patient-reported quality-of-life clinical endpoints of urinary domain summary score (UDSS) and bowel domain summary score (BDSS) in 35 patients using the Spearman correlation test. Only the significant correlations between a feature that was reliably changed in ≥7 patients (20%) by RCI and an endpoint were considered as true significant correlations. RESULTS: The 352 (34.4%) and 386 (37.7%) features among all 1023 features were determined by RCI to be reliably changed in more than five (10%) patients in the CTV and PTV, respectively. Nineteen features were found reliably changed in the CTV and 31 features in the PTV, respectively, in 10 (20%) or more patients. These features were not necessarily associated with significantly different longitudinal feature values (group p-value < 0.05). Most reliably changed features in more than 10 patients had excellent or good baseline test-retest reliability ICC, while none showed poor reliability. The RCI method ruled out the features to be reliably changed when substantial feature measurement bias was presented. After applying the RCI criterion, only four and five true significant correlations were confirmed with UDSS and BDSS in the CTV, respectively, with low true significance correlation rates of 10.8% (4/37) and 17.9% (5/28). No true significant correlations were found in the PTV. CONCLUSIONS: The RCI method was proposed for delta-radiomics and demonstrated using PCa MRgRT data. The RCI has advantages over some other statistical metrics commonly used in the previous delta-radiomics studies, and is useful to reliably identify the longitudinal radiomics feature change on an individual basis. This proposed RCI method should be helpful for the development of essential feature selection methodology in delta-radiomics.


Assuntos
Imageamento por Ressonância Magnética , Masculino , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Estudos Longitudinais , Imageamento por Ressonância Magnética/métodos
8.
J Magn Reson Imaging ; 57(2): 485-492, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35753084

RESUMO

BACKGROUND: Liver fibrosis is characterized by macromolecule depositions. Recently, a novel technology termed macromolecular proton fraction quantification based on spin-lock magnetic resonance imaging (MPF-SL) is reported to measure macromolecule levels. HYPOTHESIS: MPF-SL can detect early-stage liver fibrosis by measuring macromolecule levels in the liver. STUDY TYPE: Retrospective. SUBJECTS: Fifty-five participants, including 22 with no fibrosis (F0) and 33 with early-stage fibrosis (F1-2), were recruited. FIELD STRENGTH/SEQUENCE: 3 T; two-dimensional (2D) MPF-SL turbo spin-echo sequence, 2D spin-lock T1rho turbo spin-echo sequence, and multi-slice 2D gradient echo sequence. ASSESSMENT: Macromolecular proton fraction (MPF), T1rho, liver iron concentration (LIC), and fat fraction (FF) biomarkers were quantified within regions of interest. STATISTICAL TESTS: Group comparison of the biomarkers using Mann-Whitney U tests; correlation between the biomarkers assessed using Spearman's rank correlation coefficient and linear regression with goodness-of-fit; fibrosis stage differentiation using receiver operating characteristic curve (ROC) analysis. P-value < 0.05 was considered statistically significant. RESULTS: Average T1rho was 41.76 ± 2.94 msec for F0 and 41.15 ± 3.73 msec for F1-2 (P = 0.60). T1rho showed nonsignificant correlation with either liver fibrosis (ρ = -0.07; P = 0.61) or FF (ρ = -0.14; P = 0.35) but indicated a negative correlation with LIC (ρ = -0.66). MPF was 4.73 ± 0.45% and 5.65 ± 0.81% for F0 and F1-2 participants, respectively. MPF showed a positive correlation with liver fibrosis (ρ = 0.59), and no significant correlations with LIC (ρ = 0.02; P = 0.89) or FF (ρ = 0.05; P = 0.72). The area under the ROC curve was 0.85 (95% confidence interval [CI] 0.75-0.95) and 0.55 (95% CI 0.39-0.71; P = 0.55) for MPF and T1rho to discriminate between F0 and F1-2 fibrosis, respectively. DATA CONCLUSION: MPF-SL has the potential to diagnose early-stage liver fibrosis and does not appear to be confounded by either LIC or FF. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Cirrose Hepática , Prótons , Humanos , Estudos Retrospectivos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Fígado/patologia , Fibrose , Substâncias Macromoleculares , Biomarcadores
9.
Spine Deform ; 11(1): 87-93, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36098947

RESUMO

PURPOSE: The apical deformation in adolescent idiopathic scoliosis (AIS) is a combination of rotation, coronal deviation and passive anterior lengthening of the spine. In AIS surgery, posterior-concave lengthening or anterior-convex shortening can be part of the corrective maneuver, as determined by the individual surgeon's technique. The magnitude of convex-concave and anterior-posterior length discrepancies, and how this needs to be modified to restore optimal spinal harmony, remains unknown. METHODS: CT-scans of 80 pre-operative AIS patients with right convex primary thoracic curves were sex- and age-matched to 80 healthy controls. The spinal length parameters of the main thoracic curves were compared to corresponding levels in controls. Vertebral body endplates and posterior elements were semi-automatically segmented to determine the length of the concave and convex side of the anterior column and along the posterior pedicle screw entry points while taking the 3D-orientation of each individual vertebra into account. RESULTS: The main thoracic curves showed anterior lengthening with a mean anterior-posterior length discrepancy of + 3 ± 6%, compared to a kyphosis of - 6 ± 3% in controls (p < 0.01). In AIS, the convex side was 20 ± 7% longer than concave (0 ± 1% in controls; p < 0.01). The anterior and posterior concavity were 7 and 22 mm shorter, respectively, while the anterior and posterior convexity were 21 and 8 mm longer compared to the controls. CONCLUSIONS: In thoracic AIS, the concave shortening is more excessive than the convex lengthening. To restore spinal harmony, the posterior concavity should be elongated while allowing for some shortening of the posterior convexity.


Assuntos
Cifose , Parafusos Pediculares , Escoliose , Humanos , Adolescente , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia , Tomografia Computadorizada por Raios X/métodos
10.
Alzheimers Dement (N Y) ; 8(1): e12369, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36583111

RESUMO

Introduction: Cerebral small vessel disease (SVD) is an important cause of dementia that lacks effective treatment. We evaluated the efficacy and safety of cilostazol, an antiplatelet agent with potential neurovascular protective effects, in slowing the progression of white matter hyperintensities (WMHs) in stroke- and dementia-free subjects harboring confluent WMH on magnetic resonance imaging (MRI). Methods: In this single-center, randomized, double-blind, placebo-controlled study, we randomized stroke- and dementia-free subjects with confluent WMHs to receive cilostazol or placebo for 2 years in a 1:1 ratio. The primary outcome was change in WMH volume over 2 years. Secondary outcomes were changes in brain volumes, lacunes, cerebral microbleeds, perivascular space, and alterations in white matter microstructural integrity, cognition, motor function, and mood. Results: We recruited 120 subjects from October 27, 2014, to January 21, 2019. A total of 55 subjects in the cilostazol group and 54 subjects in the control group were included for intention-to-treat analysis. At 2-year follow-up, the changes in WMH volume were not statistically different between cilostazol treatment and placebo (0.3±1.0 mL vs -0.1±0.8 mL, p = 0.167). Secondary outcomes, bleeding and vascular events, were also not statistically different between the two groups. Discussion: In this trial with stroke- and dementia-free subjects with confluent WMHs, cilostazol did not impact WMH progression but demonstrated an acceptable safety profile. Future studies should address the treatment effects of cilostazol on subjects at different clinical stages of SVD.

11.
Nat Sci Sleep ; 14: 2013-2021, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36394067

RESUMO

Background: Lateral parapharyngeal wall (LPW) thickness is a potentially useful anatomical marker of childhood obstructive sleep apnea (OSA). Measuring LPW thickness by ultrasonography (USG) is technically feasible but its use in children has not been validated. Therefore, this study aimed to assess the intra- and inter-operator reliability of the sonographic measurements of LPW thickness in children and to assess its validity against magnetic resonance imaging (MRI) measurements. Methods: Prepubertal children aged 6-11 years suspected to suffer from OSA were recruited. Repeated measurements of LPW thickness by USG were conducted to evaluate the intra- and inter-operator reliability, examined by intraclass correlation coefficient (ICC). LPW thickness was measured as the distance between the internal carotid artery and the echogenic surface of the pharynx in an oblique coronal plane by USG. LPW thickness was measured by MRI at the retropalatal level. The agreement between the LPW thickness measured by USG and MRI was assessed by ICC and Bland-Altman plot. Results: Thirty-four children (mean age: 8.66 ± 1.61, 26 male) were recruited. The intra- and inter-operator reliability of the LPW thickness by USG was good (ICC = 0.84 and 0.82, respectively). The agreement between the USG-measured and MRI-measured LPW thickness was moderate (ICC = 0.72). he Bland-Altman plot demonstrated a mean difference of 0.061 cm and a 95% limit of agreement from 0.91 to 1.12 cm. Conclusion: In this study, we demonstrated that ultrasonography is a valid and reliable method to assess LPW thickness in children. This study was supported by the Direct Grant for Research from the Research Committee of the Chinese University of Hong Kong (Project no. 2020.073).

12.
Asia Pac J Ophthalmol (Phila) ; 11(5): 417-424, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36179335

RESUMO

PURPOSE: To evaluate the presenting radiological features of immunoglobulin G4-related ophthalmic disease (IgG4-ROD) and their associations with IgG4-related optic neuropathy (IgG4-RON), and IgG4-related ocular adnexal lymphoma (IgG4-ROL). METHODS: A territory-wide, biopsy-proven, Chinese cohort. Masked review of orbital images, medical records, and histopathology reports. RESULTS: A total of 115 (94%) of the 122 patients in our cohort had preoperative orbital images (computed tomography=105, magnetic resonance imaging=40). Among them, 103/115 (90%) showed enlarged lacrimal glands, and 91 (88%) were bilateral. Nerve enlargement was observed: infraorbital in 31/115 (27%) patients and frontal in 17/115 (15%), 10 and 9 being bilateral, respectively. At least 1 or more extraocular muscle (EOM) enlargement was found in 41/115 (37%) patients, bilaterally in 20. Lateral rectus occurred in 30 (73%) of these 41 EOM patients and inferior rectus in 28 (68%). Two adjacent EOMs (inferior and lateral recti in 11 patients, inferior and medial recti in 7 patients) or multiple EOMs (at least 3) were enlarged in 23/41 (56%) and 13/41 (32%) of the patients, respectively. Intraconal lesions (67% vs 11%, P<0.05), infraorbital (83% vs 23%, P<0.005), or frontal (50% vs 15%, P<0.05) nerve enlargement was significantly associated with IgG4-RON (6 patients) by univariate analyses. Asymmetric lacrimal gland enlargement and discrete orbital mass (both P<0.05) were associated with IgG4-ROL (9 patients) by multivariate analyses. CONCLUSIONS: In this IgG4-ROD cohort, most patients had bilateral enlarged lacrimal glands, and the lateral rectus is the most frequently involved EOM. For the first time, unique radiological patterns associated with the development of IgG4-RON and IgG4-ROL are found.


Assuntos
Doença Relacionada a Imunoglobulina G4 , Doenças do Aparelho Lacrimal , Doenças Orbitárias , Estudos de Coortes , Humanos , Hipertrofia , Imunoglobulina G , Doença Relacionada a Imunoglobulina G4/complicações , Doença Relacionada a Imunoglobulina G4/diagnóstico por imagem , Doenças Orbitárias/diagnóstico por imagem , Estudos Retrospectivos
13.
Trials ; 23(1): 306, 2022 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-35422056

RESUMO

BACKGROUND: Active participation in intellectual leisure activities such as calligraphy helps prevent cognitive decline and dementia, but the underlying mechanisms are not fully understood. With disrupted functional connectivity (FC) of default mode network (DMN) associated with cognitive decline, we speculate that intellectual activities might optimize cognitive function through modulating FC of DMN. This two-arm single-blind randomized controlled trial aims to identify the effects of increasing practice of calligraphy on cognitive function and FC of DMN in people with subjective cognitive decline (SCD). METHODS: One hundred twelve community-living Chinese aged 55 to 75 years old with SCD but without mild cognitive impairment or dementia and with prior practice of calligraphy as defined by 1 h of calligraphy per week will be recruited through elderly social centres in Hong Kong and randomized into either control or intervention group. The control group will continue with their usual practice of calligraphy, whereas the intervention group will double their practice of calligraphy. Measurement of cognitive outcomes and neuroimaging on resting-state FC will be performed at baseline and in 6 months. Repeated measures analysis of variance will be used to assess cognitive and FC changes, with time being the within-group factor, control/intervention as the between-group measure, and important covariates (age, sex, educational and occupational attainment, health, and other lifestyle factors) controlled for. DISCUSSION: This study will shed light on the underlying neurocognitive mechanisms of how intellectual activities promotes cognitive maintenance. Our anticipated findings will provide evidence that reversing or slowing FC disruption by actively participating in intellectual activities is still possible for the at-risk individuals. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR1900024433 . Registered on 11 July 2019.


Assuntos
Disfunção Cognitiva , Demência , Idoso , Cognição , Disfunção Cognitiva/prevenção & controle , Disfunção Cognitiva/psicologia , Rede de Modo Padrão , Demência/prevenção & controle , Humanos , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Método Simples-Cego
14.
Front Oncol ; 12: 1053698, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36686831

RESUMO

Background: Low health literacy (HL) is negatively associated with mammography screening uptake. However, evidence of the links between poor HL and low mammography screening participation is scarce. Methods: We conducted a cross-sectional questionnaire survey among participants of a cancer screening program. We measured HL using a validated Chinese instrument. We assessed breast cancer screening-related beliefs using the Health Belief Model and the accuracy of risk perception. We used multivariable regression models to estimate the relationship between HL and the outcomes. Results: A total of 821 females were included. 264 (32.2%) had excellent or sufficient, 353 (43.0%) had problematic, and 204 (24.8%) had inadequate health literacy (IHL). Women with IHL were more likely to agree that high price (ß = -0.211, 95% CI -0.354 to -0.069), lack of time (ß = -0.219, 95% CI -0.351 to -0.088), inconvenient service time (ß = -0.291, 95% CI -0.421 to -0.160), long waiting time (ß = -0.305, 95% CI -0.447 to -0.164), fear of positive results (ß = -0.200, 95% CI -0.342 to -0.058), embarrassment (ß = -0.225, 95% CI -0.364 to -0.086), fear of pain (ß = -0.154, 95% CI -0.298 to -0.010), fear of radiation (ß = -0.177, 95% CI -0.298 to -0.056), lack of knowledge on service location (ß = -0.475, 95% CI -0.615 to -0.335), and lack of knowledge on mammography (ß = -0.360, 95% CI -0.492 to -0.228) were barriers. They were also less likely to have an accurate breast cancer risk perception (aOR 0.572, 95% CI 0.341 to 0.956). Conclusion: Women with lower HL could have stronger perceived barriers to BC screening and an over-estimation of their breast cancer risk. Tackling emotional and knowledge barriers, financial and logistical assistance, and guidance on risk perception are needed to increase their breast cancer screening uptake.

15.
Int J Bipolar Disord ; 9(1): 40, 2021 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-34877622

RESUMO

BACKGROUND: To examine the antidepressant efficacy and response predictors of R-DLPFC-LF rTMS for antidepressant-nonresponding BD. METHODS: We conducted a single-blind randomized sham-controlled trial for 54 (28 sham, 26 active) patients with antidepressant-nonresponding BD (baseline MADRS ≥ 20). Patients received 15 daily sessions of active or sham neuronavigated rTMS (Figure-of-8 coil, five 1 Hz 60 s 110% RMT trains). Outcome measures included depressive response (≥ 50% MADRS reduction, CGI ≤ 2) and remission (MADRS < 7, CGI = 1) rates, treatment emergent hypo/mania (YMRS), depressive and anxiety symptoms (HAM-A). RESULTS: 48 patients (25 sham, 23 active) completed treatment, with 3 drop-outs each in active and sham groups. Active rTMS did not produce superior response or remission rates at endpoint or 6 or 12 weeks (ps > 0.05). There was no significant group * time interaction (ps > 0.05) in a multivariate ANOVA with MADRS, HAMA and YMRS as dependent variables. Exploratory analysis found MADRS improvement to be moderated by baseline anxiety (p = 0.02) and melancholia (p = 0.03) at week 3, and depressive onset at weeks 6 (p = 0.03) and 12 (p = 0.04). In subjects with below-mean anxiety (HAMA < 20.7, n = 24), MADRS improvement from active rTMS was superior to sham at week 3 (ITT, t = 2.49, p = 0.04, Cohen's d = 1.05). No seizures were observed. Groups did not differ in treatment-emergent hypomania (p = 0.1). LIMITATIONS: Larger sample size might be needed to power subgroup analyses. Moderation analyses were exploratory. Single-blind design. Unblinding before follow-up assessments due to ethical reasons. CONCLUSIONS: 1-Hz 110% RMT (5 × 60 s trains) R-DLPFC-LF rTMS was not effective for antidepressant non-responding BD but may be further investigated at increased dosage and/or in BD patients with low anxiety. Trial registration CCRB Clinical Trials Registry, CUHK, CUHK_CCT00440. Registered 04 December 2014, https://www2.ccrb.cuhk.edu.hk/registry/public/279.

16.
Quant Imaging Med Surg ; 11(10): 4431-4460, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34603997

RESUMO

Radiomics research is rapidly growing in recent years, but more concerns on radiomics reliability are also raised. This review attempts to update and overview the current status of radiomics reliability research in the ever expanding medical literature from the perspective of a single reliability metric of intraclass correlation coefficient (ICC). To conduct this systematic review, Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. After literature search and selection, a total of 481 radiomics studies using CT, PET, or MRI, covering a wide range of subject and disease types, were included for review. In these highly heterogeneous studies, feature reliability to image segmentation was much more investigated than reliability to other factors, such as image acquisition, reconstruction, post-processing, and feature quantification. The reported ICCs also suggested high radiomics feature reliability to image segmentation. Image acquisition was found to introduce much more feature variability than image segmentation, in particular for MRI, based on the reported ICC values. Image post-processing and feature quantification yielded different levels of radiomics reliability and might be used to mitigate image acquisition-induced variability. Some common flaws and pitfalls in ICC use were identified, and suggestions on better ICC use were given. Due to the extremely high study heterogeneities and possible risks of bias, the degree of radiomics feature reliability that has been achieved could not yet be safely synthesized or derived in this review. More future researches on radiomics reliability are warranted.

17.
Quant Imaging Med Surg ; 11(7): 3306-3313, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34249655

RESUMO

BACKGROUND: Biplanar X-ray system providing anteroposterior and sagittal plane with an ultra-low radiation dose and in weight-bearing position is increasingly used for spine imaging. The original three-dimensional (3D) reconstruction method from biplanar X-rays has been widely used for clinical parameters, however, the main issue is that manual adjustments of the 3D model was quite time-consuming and limited to thoracolumbar spine. A quasi-automated 3D reconstruction method of the spine from cervical vertebra to pelvis was proposed, which proved fast and accurate in 57 patients with adolescent idiopathic scoliosis. The aim of this study was to compare the newly developed technique of quasi-automatic 3D measurement with classical 2D measurements in a large cohort. METHODS: A total of 494 adults with biplanar EOS X-ray scanning were included in this study and divided into health and deformity group according to the presence of spinal deformity. The proposed method of quasi-automatic 3D measurement was applied to all these subjects. The radiographic parameters included: thoracic kyphosis (TK), lumbar lordosis (LL), pelvic incidence (PI), pelvic tilt (PT), sagittal vertical axis (SVA), T1 pelvic angle (TPA) in sagittal plane, and cobb angle in coronal plane. Comparison was made between quasi-automatic and manual measurement. RESULTS: The mean age was 53.7±19.9 years old. In the whole population, the mean differences between the two methods were 3.9° for TK (30.5°±9.9° vs. 26.5°±9.3°, P<0.001), -5.2° for LL (-47.5°±11.2° vs. -42.4°±11.0°, P<0.001), 3.6° for PI (46.9°±10.3° vs. 43.9°±10.3°, P<0.001), -0.2° for PT (11.9°±7.7° vs. 12.0°±8.2°, P=0.328), -2.1 mm for SVA (15.7±26.2 vs. 17.8±26.3 mm, P=0.221) and -1.1° for TPA (9.0°±7.6° vs. 10.1°±7.8°, P=0.051). The deformity group had similar mean differences with the asymptomatic group with the values ranged from -4.1° to 3.8° for sagittal parameters. The mean differences of Cobb angle were 1.9° for patients with Cobb angle <30° and 2.3° for patients with Cobb angle >30°, respectively. Correlation analysis showed r2 for all clinical parameters ranged from 0.667 to 0.923. On average, the new method takes 5 minutes to compute all the parameters for one case. CONCLUSIONS: In conclusion, this ergonomic and efficient quasi-automatic method for full spine proved fast and accurate measurement in a large population, which showed great potential in extensive clinical application.

18.
Neuroimage ; 241: 118430, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34314848

RESUMO

PURPOSE: Heating of gradient coils and passive shim components is a common cause of instability in the B0 field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites. METHOD: A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors. Phantom water signals were acquired before and after an EPI sequence. The protocol consisted of: minimal preparatory imaging; a short pre-fMRI PRESS; a ten-minute fMRI acquisition; and a long post-fMRI PRESS acquisition. Both pre- and post-fMRI PRESS were non-water suppressed. Real-time frequency stabilization/adjustment was switched off when appropriate. Sixty scanners repeated the protocol for a second dataset. In addition, a three-hour post-fMRI MRS acquisition was performed at one site to observe change of gradient temperature and drift rate. Spectral analysis was performed using MATLAB. Frequency drift in pre-fMRI PRESS data were compared with the first 5:20 minutes and the full 30:00 minutes of data after fMRI. Median (interquartile range) drifts were measured and showed in violin plot. Paired t-tests were performed to compare frequency drift pre- and post-fMRI. A simulated in vivo spectrum was generated using FID-A to visualize the effect of the observed frequency drifts. The simulated spectrum was convolved with the frequency trace for the most extreme cases. Impacts of frequency drifts on NAA and GABA were also simulated as a function of linear drift. Data from the repeated protocol were compared with the corresponding first dataset using Pearson's and intraclass correlation coefficients (ICC). RESULTS: Of the data collected from 99 scanners, 4 were excluded due to various reasons. Thus, data from 95 scanners were ultimately analyzed. For the first 5:20 min (64 transients), median (interquartile range) drift was 0.44 (1.29) Hz before fMRI and 0.83 (1.29) Hz after. This increased to 3.15 (4.02) Hz for the full 30 min (360 transients) run. Average drift rates were 0.29 Hz/min before fMRI and 0.43 Hz/min after. Paired t-tests indicated that drift increased after fMRI, as expected (p < 0.05). Simulated spectra convolved with the frequency drift showed that the intensity of the NAA singlet was reduced by up to 26%, 44 % and 18% for GE, Philips and Siemens scanners after fMRI, respectively. ICCs indicated good agreement between datasets acquired on separate days. The single site long acquisition showed drift rate was reduced to 0.03 Hz/min approximately three hours after fMRI. DISCUSSION: This study analyzed frequency drift data from 95 3T MRI scanners. Median levels of drift were relatively low (5-min average under 1 Hz), but the most extreme cases suffered from higher levels of drift. The extent of drift varied across scanners which both linear and nonlinear drifts were observed.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Análise de Dados , Bases de Dados Factuais/normas , Imageamento por Ressonância Magnética/normas , Espectroscopia de Ressonância Magnética/normas , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos
19.
Front Oncol ; 11: 631666, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33718212

RESUMO

Colorectal cancer (CRC), prostate cancer (PC) and breast cancer (BC) are among the most common cancers worldwide with well-established screening strategies. We aim to investigate the effectiveness and compliance of a one-stop screening service for CRC, PC and BC. Asymptomatic subjects aged 50-75 years were invited. Eligible subjects were offered fecal immunochemical test (FIT) for CRC screening. Serum prostate specific antigen (PSA) and Prostate Health Index (PHI) were offered for male PC screening and mammogram (MMG) for female BC screening as a one-stop service. Colonoscopy was offered to FIT+ subjects, prostate biopsy to PSA/PHI+ (PSA>10/PHI≥35) males and breast biopsy to MMG+ (Breast Imaging-Reporting and Data System, BI-RADS≥4) females. From August 2018 to April 2020, 3165 subjects were recruited. All participants (1372 men and 1793 women) were willing to accept FIT for CRC screening, and PSA/PHI test or MMG as second cancer screening. 102 subjects diagnosed advanced neoplasms after colonoscopy. Thirty-three males diagnosed PC after prostate biopsy and 15 females diagnosed BC after breast biopsy. No major complication reported in first tier screening tests. Subjects who were willing to undergo CRC screening were highly likely to accept other cancer screening when offered in a one-stop program. In conclusion, the effectiveness and compliance of a one-stop service for CRC, PC, and BC screening among asymptomatic subjects were high. Future studies should be conducted to test various ways of integrating cancer screening programs. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, identifier NCT04034953.

20.
Clin Transl Gastroenterol ; 12(2): e00300, 2021 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-33600104

RESUMO

INTRODUCTION: Visceral adipose tissue (VAT) has been found to play a critical role in the development of metabolic syndrome and nonalcoholic fatty liver disease (NAFLD) independent of generalized obesity. METHODS: In this secondary study of prospectively acquired data, 625 participants underwent magnetic resonance spectroscopy and chemical shift fat-water separation MRI (2-point Dixon) of the liver and whole abdomen, respectively, in a 3 Tesla magnet. Whole abdominal VAT and subcutaneous adipose tissue (SAT) were extracted from the 2-point Dixon image series using an automated method. Clinical/anthropometric/blood biochemistry parameters were measured. Using region-specific body mass index, participants were classified into 3 paired subgroups (lean, overweight, and obese) and presence of NAFLD (liver fat content ≥ 5.5%). RESULTS: All relevant clinical/anthropometric/blood biochemistry characteristics and liver enzymes were statistically significant between groups (P < 0.001). NAFLD was found in 12.1%, 43.8%, and 68.3% and metabolic syndrome in 51.1%, 61.9%, and 65% of the lean, overweight, and obese, respectively. Odds ratio for metabolic syndrome and NAFLD was increased by 2.73 (95% confidence interval [CI] 2.18-3.40) and 2.53 (95% CI 2.04-3.12), respectively, for 1SD increase in VAT volume while prevalence of metabolic syndrome was increased by 2.26 (95% CI 1.83-2.79) for 1SD increase in liver fat content (%). VAT/SAT ratio in the lean with fatty liver showed the highest ratio (0.54) among all the subgroups, without a significant difference between the lean and obese with NAFLD (P = 0.127). DISCUSSION: Increased VAT volume/disproportional distribution of VAT/SAT may be vital drivers to the development of metabolic syndrome and NAFLD irrespective of body mass index category.


Assuntos
Gordura Abdominal/patologia , Síndrome Metabólica/patologia , Hepatopatia Gordurosa não Alcoólica/patologia , Gordura Abdominal/diagnóstico por imagem , Adulto , Idoso , Povo Asiático , Índice de Massa Corporal , Feminino , Hong Kong , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Síndrome Metabólica/diagnóstico por imagem , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Obesidade/diagnóstico por imagem , Obesidade/patologia , Sobrepeso/diagnóstico por imagem , Sobrepeso/patologia , Estudos Prospectivos , Magreza/diagnóstico por imagem , Magreza/patologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...