Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 276: 126204, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38728803

RESUMO

Detecting progesterone (P4) concentration in cow serum is essential for monitoring the pregnancy progress after fertilization and is significant for the dairy farming industry and veterinary medicine. This study reports enzyme-free immunomagnetic beads (IMBs)-based competitive immunoassay for detecting P4 by P4-bovine serum albumin (BSA)-modified biosensors. The anti-P4 antibody-conjugated IMBs serve as collectors to capture P4 in undiluted serum samples to prevent the biosensor surface from biosample contamination and as insulated labels to report the electron-transfer resistance signal of electrochemical impedance spectroscopy (EIS) measurement. The IMBs and P4-containing samples were mixed for 15-30 min, capable of obtaining stable P4@IMB complexes. The 0.2-kGauss pulsed magnetic field (PMF) of the 20-s pulse width and 20-s relaxation time applied for 5 min can shorten the immunoreaction time between the P4@IMBs and the P4-BSA-modified biosensor and reduce the IMB's nonspecific adsorption on the biosensor surface. This competitive immunoassay's cut-off value and detection limit were 7.71 ng/mL and 7.33 ng/mL, respectively, which is lower than the serum's P4 plateau concentration (over 8 ng/mL) of dairy cows on days 6-16 of estrus cycles and that in pregnancy. The IMB-based immunoassay combining the PMF attraction and the label-free EIS measurement exhibits promising potential for rapidly detecting P4 in undiluted serum.


Assuntos
Análise Química do Sangue , Bovinos , Imunoensaio , Progesterona , Indústria de Laticínios , Animais , Progesterona/sangue , Análise Química do Sangue/instrumentação , Análise Química do Sangue/métodos , Análise Química do Sangue/veterinária , Imunoensaio/instrumentação , Imunoensaio/métodos , Imunoensaio/veterinária , Separação Imunomagnética/veterinária , Gravidez , Campos Magnéticos
2.
Biosensors (Basel) ; 13(1)2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36671960

RESUMO

Electrochemical immunosensors have attracted immense attention due to the ease of mass electrode production and the high compatibility of the miniature electric reader, which is beneficial for developing point-of-care diagnostic devices. Electrochemical immunosensors can be divided into label-free and label-based sensing strategies equipped with potentiometric, amperometric, voltammetric, or impedimetric detectors. Emerging nanomaterials are frequently used on electrochemical immunosensors as a highly rough and conductive interface of the electrodes or on nanocarriers of immobilizing capture antibodies, electroactive mediators, or catalyzers. Adopting nanomaterials can increase immunosensor characteristics with lower detection limits and better sensitivity. Recent research has shown innovative immobilization procedures of nanomaterials which meet the requirements of different electrochemical immunosensors. This review discusses the past five years of advances in nanomaterials (metal nanoparticles, metal nanostructures, carbon nanotubes, and graphene) integrated into the electrochemical immunosensor. Furthermore, the new tendency and endeavors of nanomaterial-based electrochemical immunosensors are discussed.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Nanotubos de Carbono , Técnicas Eletroquímicas , Imunoensaio/métodos , Nanoestruturas/química
3.
Sensors (Basel) ; 20(3)2020 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-32023863

RESUMO

The sensing properties of immunosensors are determined not only by the amount of immobilized antibodies but also by the number of effective antigen-binding sites of the immobilized antibody. Protein A (PA) exhibits a high degree of affinity with the Fc part of IgG antibody to feasibly produce oriented antibody immobilization. This work proposes a simple method to control the PA surface density on gold nanostructure (AuNS)-deposited screen-printed carbon electrodes (SPCEs) by mixing concentration-varied PA and bovine serum albumin (BSA), and to explore the effect of PA density on the affinity attachment of anti-salbutamol (SAL) antibodies by electrochemical impedance spectroscopy. A concentration of 100 µg/mL PA and 100 µg/mL BSA can obtain a saturated coverage on the 3-mercaptoproponic acid (MPA)/AuNS/SPCEs and exhibit a 50% PA density to adsorb the amount of anti-SAL, more than other concentration-varied PA/BSA-modified electrodes. Compared with the randomly immobilized anti-SAL/MPA/AuNS/SPCEs and the anti-SAL/PA(100 µg/mL):BSA(0 µg/mL)/MPA/AuNS/SPCE, the anti-SAL/PA(100 µg/mL): BSA(100 µg/mL)/MPA/AuNS/SPCE-based immunosensors have better sensing properties for SAL detection, with an extremely low detection limit of 0.2 fg/mL and high reproducibility (<2.5% relative standard deviation). The mixture of PA(100 µg/mL):BSA(100 µg/mL) for the modification of AuNS/SPCEs has great promise for forming an optimal protein layer for the oriented adsorption of IgG antibodies to construct ultrasensitive SAL immunosensors.


Assuntos
Albuterol/isolamento & purificação , Técnicas Biossensoriais , Imunoensaio/métodos , Albuterol/imunologia , Anticorpos Imobilizados/química , Carbono/química , Ouro/química , Humanos , Limite de Detecção , Nanoestruturas , Soroalbumina Bovina/química , Soroalbumina Bovina/imunologia , Proteína Estafilocócica A/química , Proteína Estafilocócica A/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...