Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Circulation ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38742915

RESUMO

Background: The administration of intravenous cangrelor at reperfusion achieves faster onset of platelet P2Y12 inhibition than oral ticagrelor and has been shown to reduce myocardial infarct (MI) size in the pre-clinical setting. We hypothesized that the administration of cangrelor at reperfusion will reduce MI size and prevent microvascular obstruction (MVO) in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI). Methods: This was a Phase 2, multi-center, randomized, double-blind, placebo controlled clinical trial conducted between November 2017 to November 2021 in six cardiac centers in Singapore (NCT03102723). Patients were randomized to receive either cangrelor or placeboinitiated prior to the PPCI procedure on top of oral ticagrelor. The key exclusion criteria included: presenting <6 hours of symptom onset, prior MI and stroke or transient ischemic attack; on concomitant oral anticoagulants; and a contraindication for cardiovascular magnetic resonance (CMR). The primary efficacy endpoint was acute MI size by CMR within the first week expressed as percentage of the left ventricle mass ( %LVmass). MVO was identified as areas of dark core of hypoenhancement within areas of late gadolinium enhancement. The primary safety endpoint was Bleeding Academic Research Consortium (BARC)-defined major bleeding in the first 48 hours. Continuous variables were compared by Mann-Whitney U test [reported as median (1st quartile- 3rd quartile)] and categorical variables were compared by Fisher's exact test. A 2-sided P<0.05 was considered statistically significant. Results: Of 209 recruited patients, 164 patients (78% ) completed the acute CMR scan. There were no significant differences in acute MI size [placebo: 14.9 (7.3 - 22.6) %LVmass versus cangrelor: 16.3 (9.9 - 24.4)%LVmass, P=0.40] or the incidence [placebo: 48% versus cangrelor: 47%, P=0.99] and extent of MVO [placebo:1.63 (0.60 - 4.65)%LVmass versus cangrelor: 1.18 (0.53 - 3.37)%LVmass, P=0.46] between placebo and cangrelor despite a two-fold decrease in platelet reactivity with cangrelor. There were no BARC-defined major bleeding events in either group in the first 48 hours. Conclusions: Cangrelor administered at time of PPCI did not reduce acute MI size or prevent MVO in STEMI patients given oral ticagrelor despite a significant reduction of platelet reactivity during the PCI procedure.

2.
Transl Stroke Res ; 14(3): 357-363, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35856131

RESUMO

Identification of patients with high-risk asymptomatic carotid plaques remains a challenging but essential step in stroke prevention. Current selection criteria for intervention in carotid disease are still determined by symptomatology and degree of luminal stenosis. This strategy has been less effective in identifying the high-risk asymptomatic individual patients. Inflammation is the key factor that drives plaque instability causing clinical sequelae. Currently, there is no imaging tool in routine clinical practice to assess the inflammatory status within atherosclerotic plaques. Herein we describe the development of a novel molecular magnetic resonance imaging (MRI) strategy to interrogate plaque inflammation, and hence its vulnerability in vivo, using dual-targeted iron particle-based probes and fast imaging with steady-state precession (FISP) sequence, adding further prognostic information to luminal stenosis alone. A periarterial cuff was used to generate high-risk plaques at specific timepoints and location of the carotid artery in an apolipoprotein-E-deficient mouse model. Using this platform, we demonstrated that in vivo dual-targeted iron particles with enhanced FISP can (i) target and characterise high-risk vulnerable plaques and (ii) quantitatively report and track the inflammatory activity within carotid plaques longitudinally. This molecular imaging tool may permit (i) accurate monitoring of the risk of carotid plaques and (ii) timely identification of high-risk asymptomatic patients for prophylactic carotid intervention, achieving early stroke prevention.


Assuntos
Doenças das Artérias Carótidas , Estenose das Carótidas , Placa Aterosclerótica , Acidente Vascular Cerebral , Animais , Camundongos , Estenose das Carótidas/complicações , Constrição Patológica/complicações , Constrição Patológica/patologia , Doenças das Artérias Carótidas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Placa Aterosclerótica/patologia , Artérias Carótidas/patologia , Acidente Vascular Cerebral/etiologia , Ferro , Inflamação/complicações
3.
Eur Radiol ; 31(2): 640-649, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32870393

RESUMO

OBJECTIVES: Simultaneous multi-slice (SMS) imaging with short repetition time (TR) accelerates diffusion tensor imaging (DTI) acquisitions. However, its impact when combined with readout-segmented echo planar imaging (RESOLVE) on the cranial nerves given the challenging skull base/posterior fossa terrain is unexplored. We evaluated the reliability of trigeminal nerve DTI metrics using SMS with RESOLVE-DTI. METHODS: Eight healthy controls and six patients with unilateral trigeminal neuralgia (TN) underwent brain MRI scan. Three different RESOLVE-DTI protocols were performed on a 3-T MRI system: non-SMS (TR = 4330 ms), SMS with identical TR (4330 ms), and SMS with short TR (2400 ms). Pontine signal-to-noise ratio (SNR) and DTI metrics of the trigeminal nerve streamlines tracked by two independent raters using deterministic tractography and standardized tracking protocol were obtained. These were statistically analyzed and compared across the three protocols using intra-rater and inter-rater intraclass correlation coefficients (ICCs), one-way analysis of variance (ANOVA), post hoc analysis, and linear regression. RESULTS: On visual screening, there were no artifacts across the trigeminal nerves. All data also cleared objective image quality assurance analysis. Pontine SNR was similar for the two SMS protocols and higher for the non-SMS RESOLVE-DTI (F(2,36) = 4.40, p = 0.02). Intra-rater and inter-rater ICCs were very good (> 0.85). Trigeminal nerve DTI metrics were consistently measured by the three protocols, revealing significant linear relationships between non-SMS- and SMS-derived DTI metrics. CONCLUSION: SMS RESOLVE-DTI enables fast and reliable evaluation of microstructural integrity of the trigeminal nerve, with potential application in the clinical management of TN. KEY POINTS: • Readout-segmented diffusion-weighted echo planar imaging (RESOLVE-DTI) reduces image distortion artifacts in the posterior fossa but its long acquisition time limits clinical utility. • Simultaneous multi-slice (SMS) imaging combined with RESOLVE-DTI provides reliable trigeminal nerve tractography with potential applications in trigeminal neuralgia. • Two-fold-accelerated RESOLVE-DTI yields comparable trigeminal nerve streamlines and DTI metrics while near-halving acquisition time.


Assuntos
Imagem de Tensor de Difusão , Imagem Ecoplanar , Humanos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Nervo Trigêmeo/diagnóstico por imagem
4.
Eur Radiol ; 30(1): 119-127, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31372787

RESUMO

OBJECTIVES: To compare visualization of joint intracranial and carotid vessel walls between 5× compressed sensing accelerated three-dimensional DANTE-SPACE sequence (CS VWI) acquired in 5 min and the same sequence accelerated by 2.7× parallel imaging (PI VWI) which takes 9-10 min currently. METHODS: Following institutional review board approval and informed consent, 28 subjects including 20 stroke patients underwent PI and CS VWI examinations with an acquired spatial resolution of isotropic 0.55 mm and joint coverage of intracranial and carotid arteries. Quantitative wall thickness measurements of CS VWI and PI VWI were compared on healthy volunteers and patients with wall thickening respectively. Subjective wall visualizations of the two VWI methods on patients were scored by two radiologists blindly and independently using a 4-point scale followed by inter-rater reproducibility analysis. RESULTS: Linear regression analysis of wall thickness measurements showed excellent agreement between CS VWI and PI VWI in both healthy volunteers (r = 0.99) and stroke patients with wall thickening (r = 0.99). Subjective wall visualization score of CS VWI was slightly lower than PI VWI (3.13 ± 0.41 vs. 3.31 ± 0.79) but still had good diagnostic quality (> 3 based on a 4-point scale). The two radiologists' scores agreed excellently, evidenced by the intraclass correlation coefficient (ICC) values being higher than 0.75 (p < 0.001). CONCLUSIONS: Compressed sensing expedients joint intracranial and carotid VWI acquired at an isotropic resolution of 0.55 mm in 5 min without compromising quantitative vessel wall thickness measurement or diagnostic wall visualization. KEY POINTS: • CS VWI facilitates comprehensive visualization of intracranial and carotid vessel walls at an acquired isotropic resolution of 0.55 mm in a single 5-min scan. • CS VWI affords comparable vessel wall visualization and morphology measurement as PI VWI with a shortened acquisition time by 45%. • CS VWI alleviates the intensive trade-off between imaging resolution and scan time, and benefits the scan efficiency, motion robustness, and patient tolerance of high-resolution joint intracranial and carotid VWI.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Artérias Cerebrais/diagnóstico por imagem , Imageamento Tridimensional/métodos , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Reprodutibilidade dos Testes
5.
J Cardiovasc Magn Reson ; 21(1): 72, 2019 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-31752919

RESUMO

BACKGROUND: Myocardial edema in acute myocardial infarction (AMI) is commonly imaged using dark-blood short tau inversion recovery turbo spin echo (STIR-TSE) cardiovascular magnetic resonance (CMR). The technique is sensitive to cardiac motion and coil sensitivity variation, leading to myocardial signal nonuniformity and impeding reliable depiction of edematous tissues. T2-prepared balanced steady state free precession (T2p-bSSFP) imaging has been proposed, but its contrast is low, and averaging is commonly needed. T2 mapping is useful but requires a long scan time and breathholding. We propose here a single-shot magnetization prepared sequence that increases the contrast between edema and normal myocardium and apply it to myocardial edema imaging. METHODS: A magnetization preparation module (T2STIR) is designed to exploit the simultaneous elevation of T1 and T2 in edema to improve the depiction of edematous myocardium. The module tips magnetization down to the -z axis after T2 preparation. Transverse magnetization is sampled at the fat null point using bSSFP readout and allows for single-shot myocardial edema imaging. The sequence (T2STIR-bSSFP) was studied for its contrast behavior using simulation and phantoms. It was then evaluated on 7 healthy subjects and 7 AMI patients by comparing it to T2p-bSSFP and T2 mapping using the contrast-to-noise ratio (CNR) and the contrast ratio as performance indices. RESULTS: In simulation and phantom studies, T2STIR-bSSFP had improved contrast between edema and normal myocardium compared with the other two edema imaging techniques. In patients, the CNR of T2STIR-bSSFP was higher than T2p-bSSFP (5.9 ± 2.6 vs. 2.8 ± 2.0, P < 0.05) but had no significant difference compared with that of the T2 map (T2 map: 6.6 ± 3.3 vs. 5.9 ± 2.6, P = 0.62). The contrast ratio of T2STIR-bSSFP (2.4 ± 0.8) was higher than that of the T2 map (1.3 ± 0.1, P < 0.01) and T2p-bSSFP (1.4 ± 0.5, P < 0.05). CONCLUSION: T2STIR-bSSFP has improved contrast between edematous and normal myocardium compared with commonly used bSSFP-based edema imaging techniques. T2STIR-bSSFP also differentiates between fat that was robustly suppressed and fluids around the heart. The technique is useful for single-shot edema imaging in AMI patients.


Assuntos
Edema Cardíaco/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Idoso , Estudos de Casos e Controles , Simulação por Computador , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
6.
Clin Cardiol ; 42(1): 5-12, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30421441

RESUMO

BACKGROUND: In ST-segment elevation myocardial infarction (STEMI) patients treated with primary percutaneous coronary intervention (PPCI), current oral P2Y12 platelet inhibitors do not provide maximal platelet inhibition at the time of reperfusion. Furthermore, administration of cangrelor prior to reperfusion has been shown in pre-clinical studies to reduce myocardial infarct (MI) size. Therefore, we hypothesize that cangrelor administered prior to reperfusion in STEMI patients will reduce the incidence of microvascular obstruction (MVO) and limit MI size in STEMI patients treated with PPCI. METHODS: The platelet inhibition to target reperfusion injury (PITRI) trial, is a phase 2A, multi-center, double-blinded, randomized controlled trial, in which 210 STEMI patients will be randomized to receive either an intravenous (IV) bolus of cangrelor (30 µg/kg) followed by a 120-minute infusion (4 µg/kg/min) or matching saline placebo, initiated prior to reperfusion (NCT03102723). RESULTS: The study started in October 2017 and the anticipated end date would be July 2020. The primary end-point will be MI size quantified by cardiovascular magnetic resonance (CMR) on day 3 post-PPCI. Secondary endpoints will include markers of reperfusion, incidence of MVO, MI size, and adverse left ventricular remodeling at 6 months, and major adverse cardiac and cerebrovascular events. SUMMARY: The aim of the PITRI trial is to assess whether cangrelor administered prior to reperfusion would reduce acute MI size and MVO, as assessed by CMR.


Assuntos
Monofosfato de Adenosina/análogos & derivados , Circulação Coronária/fisiologia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Reperfusão Miocárdica/métodos , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Remodelação Ventricular/fisiologia , Monofosfato de Adenosina/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Infusões Intravenosas , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Traumatismo por Reperfusão Miocárdica/diagnóstico , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Miocárdio/patologia , Inibidores da Agregação Plaquetária/administração & dosagem , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Resultado do Tratamento , Adulto Jovem
7.
J Cardiovasc Magn Reson ; 20(1): 69, 2018 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-30257686

RESUMO

BACKGROUND: Myocardial fibrosis is a common pathophysiological process that is related to ventricular remodeling in congenital heart disease. However, the presence, characteristics, and clinical significance of myocardial fibrosis in Ebstein's anomaly have not been fully investigated. This study aimed to evaluate myocardial fibrosis using cardiovascular magnetic resonance (CMR) late gadolinium enhancement (LGE) and T1 mapping techniques, and to explore the significance of myocardial fibrosis in adolescent and adult patients with Ebstein's anomaly. METHODS: Forty-four consecutive patients with unrepaired Ebstein's anomaly (34.0 ± 16.2 years; 18 males), and an equal number of age- and gender-matched controls, were included. A comprehensive CMR protocol consisted of cine, LGE, and T1 mapping by modified Look-Locker inversion recovery (MOLLI) sequences were performed. Ventricular functional parameters, native T1, extracellular volume (ECV), and LGE were analyzed. Associations between myocardial fibrosis and disease severity, ventricular function, and NYHA classification were analyzed. RESULTS: LGE was found in 10 (22.7%) patients. Typical LGE in Ebstein's anomaly was located in the endocardium of the septum within the right ventricle (RV). The LV ECV of Ebstein's anomaly were significantly higher than those of the controls (30.0 ± 3.8% vs. 25.3 ± 2.3%, P < 0.001). An increased ECV was found to be independent of the existence of LGE. Positive LGE or higher ECV (≥30%) was associated with larger fRV volume, aRV volume, increased disease severity, and worse NYHA functional class. In addition, ECV was significantly correlated with the LV ejection fraction (P <  0.001). CONCLUSIONS: Both focal and diffuse myocardial fibrosis were observed in adolescent and adult patients with Ebstein's anomaly. Increased diffuse fibrosis is associated with worse LV function, increased Ebstein's severity, and worse clinical status.


Assuntos
Anomalia de Ebstein/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular , Adolescente , Adulto , Fatores Etários , Estudos de Casos e Controles , Criança , China/epidemiologia , Meios de Contraste/administração & dosagem , Estudos Transversais , Progressão da Doença , Anomalia de Ebstein/epidemiologia , Anomalia de Ebstein/patologia , Anomalia de Ebstein/fisiopatologia , Feminino , Fibrose , Gadolínio DTPA/administração & dosagem , Humanos , Masculino , Valor Preditivo dos Testes , Prevalência , Prognóstico , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
8.
J Magn Reson ; 292: 25-35, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29758451

RESUMO

PURPOSE: The purpose of this study is to evaluate the effect of diffusion on SSFP (Steady-state Free Precession) signals in triple-echo steady state (TESS) sequence and ultimately on the accuracy of T2 relaxometry. METHODS: The extended phase graph (EPG) algorithm was used to study the effect of diffusion on SSFP signals and T2 relaxometry. The simulation results were verified by a commercial phantom and in vivo studies. Based on the simulation results, a correction scheme was proposed to correct the estimated T2 values. RESULTS: T2 underestimation in TESS was evident in case of small flip angle and large unbalanced gradient moment on objects with large T2 and D values. The T2 underestimation mainly originated from the diffusion sensitivity of SSFP-echo. It was also observed that SSFP-FID (Free Induction Decay) signals increased with increasing diffusion weighting under some specific conditions. The proposed correction scheme corrected the T2 underestimation, which verified that the underestimation was due to the neglect of diffusion effect. For clinical practice of TESS in tissues with short T2 such as cartilage and muscle, the diffusion effect of TESS is negligible. CONCLUSION: The effect of diffusion cannot be neglected during TESS T2 quantification as it is the main source of T2 underestimation when small flip angle and large unbalanced gradient moment is used, especially for objects with large T2 and D values.

10.
Magn Reson Imaging ; 44: 65-71, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28807750

RESUMO

PURPOSE: To develop a technique for three dimensional (3D) high resolution joint imaging of intracranial and extracranial arterial walls with improved cerebrospinal fluid (CSF) suppression and good blood suppression based on T1 weighted sampling perfection with application optimized contrast using different angle evolutions (T1w-SPACE) and to compare this technique (hereafter, iSPACE) with alternating with nutation for tailored excitation (DANTE) prepared SPACE sequence (DANTE-SPACE) for their CSF suppression performance around the mid cerebral arteries (MCA) and blood suppression at carotid arteries. MATERIALS AND METHODS: Eight volunteers and twelve patients were prospectively recruited in this institutional review board approved study. A custom designed 32-channel coil set covering the intracranial and extracranial arteries was used for signal reception. Imaging was performed in each subject using DANTE-SPACE and iSPACE. Signal-to-noise ratios (SNR) of the vessel walls at the MCA and carotid arteries, and contrast-to-noise ratios (CNR) between vessel wall and CSF at the MCA and between vessel wall and lumen at carotid arteries from the two sequences were compared. RESULTS: In volunteers, contrast between CSF and white matter (surrogate for vessel wall signal) at the M2 segments in iSPACE was 67.9% higher than in DANTE-SPACE. At the carotid region, the SNR of vessel wall in iSPACE was 11.6% higher than DANTE-SPACE while the CNR in iSPACE was 13% higher than DANTE-SPACE. In patients, images with 0.6mm isotropic resolution were obtained in 7.5min. iSPACE showed 70.9% improvement in CNR between plaque and CSF at the M2 segments compared to DANTE-SPACE. CONCLUSION: Simultaneous extracranial and intracranial arterial wall imaging using iSPACE improved CSF suppression significantly at the M2 segment of MCA while blood suppression was comparable to DANTE-SPACE. The technique achieved 3D images with 0.6mm isotropic spatial resolution and took 7.5min using a custom made coil set. Using this technique, intracranial plaque visualization was improved with no observable image SNR degradation.


Assuntos
Artérias Cerebrais/diagnóstico por imagem , Líquido Cefalorraquidiano/química , Angiografia por Ressonância Magnética , Idoso , Artérias Carótidas , Simulação por Computador , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
11.
Sci Rep ; 7(1): 3196, 2017 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-28600567

RESUMO

The size and function of the left atrium (LA) and right atrium (RA) are related closely with the prognosis of cardiovascular diseases. However, their normal reference values, as measured by cardiac magnetic resonance (CMR), are not well established in Chinese populations. Healthy Chinese subjects (n = 135, 66 males, age 23-83 years) without cardiovascular risk factors were recruited. We imaged the LA and RA of all subjects using short axis and long axis slices by steady-state free precession (SSFP) sequences using a 3.0T scanner. The size and functional parameters were measured. Age and gender differences in LA were further explored. The normal reference values of atrial dimensions, volumes, and empty fractions (EFs) were provided by short axis (SAX) and area-length methods. Volumes and EFs derived by the area-length method showed correlated well with those derived by the by SAX method, but significantly underestimated the volumes (all P < 0.001) and overestimated the LA EFs (all P < 0.001). Atrial dimensions and volumes were generally larger in males. Conduit EFs and total EFs showed gender differences. Most atrial parameters correlated with age. In general, our results showed that gender and age have considerable impact on LA and RA size and function.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Tamanho do Órgão/fisiologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/fisiopatologia , Feminino , Átrios do Coração/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valores de Referência , Fatores Sexuais
12.
J Magn Reson Imaging ; 46(3): 905-914, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28130855

RESUMO

PURPOSE: To evaluate the feasibility of a proposed cardiorespiratory-resolved analysis in left ventricular (LV) function quantification from real-time cines in a cohort of cardiac patients. MATERIALS AND METHODS: Electrocardiograph (ECG)-free free-breathing real-time cine imaging based on the balanced steady-state free precession technique was performed on short-axis slices of 20 cardiac patients at 3T. K-means cluster segmentation was used to delineate the endocardial contours, from which the LV centroid and cavity area were determined. Respiratory and cardiac signals were respectively resolved from the filtered LV centroid displacement and time-varied LV cavity area to identify end-expiratory end-diastolic (ED) and end-systolic (ES) images. The obtained LV cavity areas and derived volumetric function indices, including ED volume (EDV), ES volume (ESV), stroke volume (SV), and ejection fraction (EF), were compared with those measured from manual analysis using two-tailed paired Student's t-tests, linear regression analyses, and Bland-Altman plots. Interobserver variability was calculated. RESULTS: The LV cavity area was strongly correlated between the proposed and conventional manual methods (r > 0.87) for three representative slices at the base, middle ventricle, and apex. The average differences between the two methods were 0.66 ± 3.22 mL for EDV, -0.02 ± 2.68 mL for ESV, 0.67 ± 3.73 mL for SV, and 0.17 ± 2.30% for EF. All paired measures exhibited strong correlations (r > 0.96) without significant differences (P = 0.38-0.98). Acceptable interobserver variability (0.19-3.55%) and strong correlations (r > 0.96) were shown for all measures between the two observers. CONCLUSION: The proposed method is feasible for efficient measurement of LV function from real-time cines. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:905-914.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Fluxo de Trabalho , Adulto , Eletrocardiografia/métodos , Estudos de Viabilidade , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Respiração
13.
J Cardiovasc Magn Reson ; 19(1): 7, 2017 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-28110638

RESUMO

BACKGROUND: Exercise cardiovascular magnetic resonance (ExCMR) has great potential for clinical use but its development has been limited by a lack of compatible equipment and robust real-time imaging techniques. We developed an exCMR protocol using an in-scanner cycle ergometer and assessed its performance in differentiating athletes from non-athletes. METHODS: Free-breathing real-time CMR (1.5T Aera, Siemens) was performed in 11 athletes (5 males; median age 29 [IQR: 28-39] years) and 16 age- and sex-matched healthy volunteers (7 males; median age 26 [interquartile range (IQR): 25-33] years). All participants underwent an in-scanner exercise protocol on a CMR compatible cycle ergometer (Lode BV, the Netherlands), with an initial workload of 25W followed by 25W-increment every minute. In 20 individuals, exercise capacity was also evaluated by cardiopulmonary exercise test (CPET). Scan-rescan reproducibility was assessed in 10 individuals, at least 7 days apart. RESULTS: The exCMR protocol demonstrated excellent scan-rescan (cardiac index (CI): 0.2 ± 0.5L/min/m2) and inter-observer (ventricular volumes: 1.2 ± 5.3mL) reproducibility. CI derived from exCMR and CPET had excellent correlation (r = 0.83, p < 0.001) and agreement (1.7 ± 1.8L/min/m2). Despite similar values at rest (P = 0.87), athletes had increased exercise CI compared to healthy individuals (at peak exercise: 12.2 [IQR: 10.2-13.5] L/min/m2 versus 8.9 [IQR: 7.5-10.1] L/min/m2, respectively; P < 0.001). Peak exercise CI, where image acquisition lasted 13-17 s, outperformed that at rest (c-statistics = 0.95 [95% confidence interval: 0.87-1.00] versus 0.48 [95% confidence interval: 0.23-0.72], respectively; P < 0.0001 for comparison) in differentiating athletes from healthy volunteers; and had similar performance as VO2max (c-statistics = 0.84 [95% confidence interval = 0.62-1.00]; P = 0.29 for comparison). CONCLUSIONS: We have developed a novel in-scanner exCMR protocol using real-time CMR that is highly reproducible. It may now be developed for clinical use for physiological studies of the heart and circulation.


Assuntos
Atletas , Aptidão Cardiorrespiratória , Teste de Esforço , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Resistência Física , Função Ventricular Esquerda , Adulto , Ciclismo , Pressão Sanguínea , Débito Cardíaco , Estudos de Casos e Controles , Teste de Esforço/instrumentação , Tolerância ao Exercício , Estudos de Viabilidade , Feminino , Coração/fisiologia , Frequência Cardíaca , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Respiração , Decúbito Dorsal , Fatores de Tempo
14.
Magn Reson Imaging ; 36: 49-55, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27989908

RESUMO

This study aims to develop and evaluate a new method for fast high resolution T1 mapping of the brain based on the Look-Locker technique. Single-shot turboflash sequence with high temporal acceleration is used to sample the recovery of inverted magnetization. Multi-slice interleaved acquisition within one inversion slab is used to reduce the number of inversion pulses and hence SAR. Accuracy of the proposed method was studied using simulation and validated in phantoms. It was then evaluated in healthy volunteers and stroke patients. In-vivo results were compared to values obtained by inversion recovery fast spin echo (IR-FSE) and literatures. With the new method, T1 values in phantom experiments agreed with reference values with median error <3%. For in-vivo experiments, a T1 map was acquired in 3.35s and the T1 maps of the whole brain were acquired in 2min with two-slice interleaving, with a spatial resolution of 1.1×1.1×4mm3. The T1 values obtained were comparable to those measured with IR-FSE and those reported in literatures. These results demonstrated the feasibility of the proposed method for fast T1 mapping of the brain in both healthy volunteers and stroke patients at 3T.


Assuntos
Encéfalo/anatomia & histologia , Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Imagens de Fantasmas , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
15.
Magn Reson Imaging ; 36: 86-92, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27989910

RESUMO

PURPOSE: To develop a RF coil system for joint imaging of intracranial and extracranial arterial vessel wall at 3T. MATERIALS AND METHOD: The coil system consists of a 24-channel head coil combined with an 8-channel carotid coil. It is compared with a standard coil configuration (12-channel head coil+4-channel neck coil+8-channel carotid coil) for SNR and g-factors in phantoms and healthy volunteers. The clinical relevance of the proposed coil system is also evaluated in patients. RESULTS: In phantom experiments, the SNR of the proposed coil system is 53% higher than the maximum SNR of the standard coil configuration at the center of the phantom which usually corresponds to the intracranial region of the head. The g-factors of the proposed coil system in the sagittal plane are lower than the standard coil configuration (by 10.8% and 26.6% for R=2 and 4 respectively) in the same experiment. In healthy volunteer experiments, 55% of the pixels have SNR above 100 for the proposed coil system, which is 33% more than that of the standard coil configuration. The maximum g-factors in the standard configuration are higher than those from the new coil design by 12% at R=2 and up to 36% at R=4 in the sagittal plane. In patients, in-vivo intracranial and extracranial arterial wall images at an isotropic spatial resolution of 0.6mm can be acquired using the proposed coil system. Plaques are well depicted from the images. CONCLUSIONS: The performance of the proposed coil set is superior to the standard coil configuration, providing high SNR, low g-factor and good spatial coverage needed for simultaneous high resolution imaging of intracranial and extracranial arterial walls. Images acquired in 7.6min using the proposed coil system can achieve an isotropic spatial resolution of 0.6mm and can be used to depict plaques on the intracranial and extracranial arterial walls in patients.


Assuntos
Artérias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Doenças Vasculares/diagnóstico por imagem , Adulto , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Artérias Carótidas , Feminino , Humanos , Doenças Arteriais Intracranianas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Ondas de Rádio , Adulto Jovem
16.
Magn Reson Imaging ; 39: 89-97, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27989914

RESUMO

PURPOSE: To implement a fast (~15min) MRI protocol for carotid plaque screening using 3D multi-contrast MRI sequences without contrast agent on a 3Tesla MRI scanner. MATERIALS AND METHODS: 7 healthy volunteers and 25 patients with clinically confirmed transient ischemic attack or suspected cerebrovascular ischemia were included in this study. The proposed protocol, including 3D T1-weighted and T2-weighted SPACE (variable-flip-angle 3D turbo spin echo), and T1-weighted magnetization prepared rapid acquisition gradient echo (MPRAGE) was performed first and was followed by 2D T1-weighted and T2-weighted turbo spin echo, and post-contrast T1-weighted SPACE sequences. Image quality, number of plaques, and vessel wall thicknesses measured at the intersection of the plaques were evaluated and compared between sequences. RESULTS: Average examination time of the proposed protocol was 14.6min. The average image quality scores of 3D T1-weighted, T2-weighted SPACE, and T1-weighted magnetization prepared rapid acquisition gradient echo were 3.69, 3.75, and 3.48, respectively. There was no significant difference in detecting the number of plaques and vulnerable plaques using pre-contrast 3D images with or without post-contrast T1-weighted SPACE. The 3D SPACE and 2D turbo spin echo sequences had excellent agreement (R=0.96 for T1-weighted and 0.98 for T2-weighted, p<0.001) regarding vessel wall thickness measurements. CONCLUSION: The proposed protocol demonstrated the feasibility of attaining carotid plaque screening within a 15-minute scan, which provided sufficient anatomical coverage and critical diagnostic information. This protocol offers the potential for rapid and reliable screening for carotid plaques without contrast agent.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Placa Amiloide/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Adulto , Idoso , Artérias Carótidas/fisiopatologia , Estudos de Casos e Controles , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Múltiplas Afecções Crônicas , Estudos Prospectivos
17.
Phys Med Biol ; 62(1): 1-16, 2017 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-27973341

RESUMO

Proton resonance frequency shift (PRFS) MR thermometry is commonly used to measure temperature in thermotherapy. The method requires a baseline temperature map and is therefore motion sensitive. Several referenceless MR thermometry methods were proposed to address this problem but their performances have never been compared. This study compared the performance of five referenceless methods through simulation, heating of ex vivo tissues and in vivo imaging of the brain and liver of healthy volunteers. Mean, standard deviation, root mean square, 2/98 percentiles of error were used as performance metrics. Probability density functions (PDF) of the error distribution for these methods in the different tests were also compared. The results showed that the phase gradient method (PG) exhibited largest error in all scenarios. The original method (ORG) and the complex field estimation method (CFE) had similar performance in all experiments. The phase finite difference method (PFD) and the near harmonic method (NH) were better than other methods, especially in the lower signal-to-noise ratio (SNR) and fast changing field cases. Except for PG, the PDFs of each method were very similar among the different experiments. Since phase unwrapping in ORG and NH is computationally demanding and subject to image SNR, PFD and CFE would be good choices as they do not need phase unwrapping. The results here would facilitate the choice of appropriate referenceless methods in various MR thermometry applications.


Assuntos
Imageamento por Ressonância Magnética/métodos , Termometria/métodos , Humanos , Fígado , Prótons , Razão Sinal-Ruído , Temperatura
18.
Med Phys ; 43(4): 1897, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27036585

RESUMO

PURPOSE: Carotid artery diseases due to plaque buildup at the carotid bifurcation are a leading cause of stroke. Accurate plaque quantification and characterization of plaque composition and morphology by magnetic resonance imaging (MRI) is essential to identifying high-risk patients. Difficulties in detecting plaque, which is physically small, and the unique physiological structure of the carotid artery make use of a radio frequency (RF) coil array with high resolution, large longitudinal coverage, and deep penetration ideal for clinical examinations. The goal of this project was to design and fabricate a sensitive RF coil array with sufficient imaging coverage and signal-to-noise ratio (SNR) for carotid artery imaging at 3 T. METHODS: Based on clinical requirements and the anatomical structure of the human carotid artery, an 8-channel carotid coil array was designed and fabricated for 3 T MRI of the carotid artery in humans. The performance of the proposed 8-channel carotid coil array was validated through bench tests and MR imaging experiments on a 3 T whole body MRI scanner. Its performance was also compared experimentally to the performance of a commercial 4-channel phased array carotid coil designed by Machnet BV (Machnet BV coil, Roden, Netherlands). RESULTS: The 8-channel carotid coil array performed significantly better in imaging the carotid artery than the commercial 4-channel Machnet BV coil in terms of the SNR, coverage, and penetration depth. In parallel imaging, the proposed 8-channel carotid coil array demonstrated a much lower maximum value and average value of the geometry factor in the region of interest. Carotid artery images acquired in vivo using the proposed 8-channel carotid artery coil and the commercial 4-channel Machnet BV coil were also compared, demonstrating the former's potential for clinical diagnosis. CONCLUSIONS: Based on the analyses of phantom and in vivo imaging studies, the proposed 8-channel carotid coil array has the potential for use in clinical diagnosis, performing better in terms of SNR, imaging coverage, and penetration depth than the commercial 4-channel carotid artery coil array at 3 T. In future studies, the proposed 8-channel carotid coil array can also serve as an important part of a large-scale multichannel coil array for imaging the whole carotid artery system, including the extracranial and intracranial arteries.


Assuntos
Artéria Carótida Primitiva/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
19.
Biomed Res Int ; 2015: 540217, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26539508

RESUMO

PURPOSE: Conventional two-dimensional vessel wall imaging has been used to depict the middle cerebral artery (MCA) wall in patients with recent small subcortical infarctions (RSSIs). However, its clinical use has been limited by restricted spatial coverage, low signal-to-noise ratio (SNR), and long scan time. We used a novel three-dimensional high-resolution MR imaging (3D HR-MRI) technique to investigate the presence, locations, and contrast-enhanced patterns of MCA plaques and their relationship with RSSI. METHODS: Nineteen consecutive patients with RSSI but no luminal stenosis on MR angiography were prospectively enrolled. 3D HR-MRI was performed using a T1w-SPACE sequence at 3.0 T. The presence, locations, and contrast-enhanced patterns of the MCA plaques on the ipsilateral and contralateral sides to the RSSI were analyzed. RESULTS: Eighteen patients successfully completed the study. MCA atherosclerotic plaques occurred more frequently on the ipsilateral than the contralateral side to the RSSI (72.2% versus 33.3%, P = 0.044). The occurrence of superiorly located plaques was significantly higher on the ipsilateral than the contralateral side of the MCA (66.7% versus 27.8%; P = 0.044). CONCLUSIONS: Superiorly located plaques are closely associated with RSSI. 3D high-resolution vessel wall imaging may be a potential tool for etiologic assessment of ischemic stroke.


Assuntos
Infarto Cerebral/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Artéria Cerebral Média/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Adulto , Idoso , Infarto Cerebral/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Média/patologia , Placa Aterosclerótica/patologia , Radiografia
20.
Magn Reson Imaging ; 33(9): 1026-1034, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26143482

RESUMO

OBJECTIVE: To study the effect of imaging parameters on the contrast of T1 weighted SPACE (Sampling Perfection with Application optimized Contrast using different angle Evolutions, a 3D TSE variant) at 3 T for high resolution imaging of intracranial plaques before contrast and with post-gadolinium induced enhancement, and evaluate its relevance to patients with intracranial atherosclerosis. MATERIALS AND METHODS: Optimized parameters giving good T1 contrast between intracranial vessel wall and cerebrospinal fluid within a specific scan time and reasonable coverage were found by simulation and validated in a healthy volunteer study. Based on the results, a clinical protocol covering the three major intracranial arteries (middle cerebral arteries, basilar arteries, and petrous internal carotid arteries) was developed. It was applied in ten patients diagnosed with intracranial arterial lesions. The accuracy of the technique in depicting vessel lumen was assessed by comparison to contrast enhanced MR angiography. The contrast enhancement ratios of the vessel wall/plaque identified were analyzed. RESULTS: Simulation and volunteer study showed that using T1 weighted SPACE, good T1 contrast between vessel wall and cerebrospinal fluid occurred at TR of around 1000 ms using an echo train length of 21 within 10 minutes at an isotropic spatial resolution of 0.5 mm. In the 10 patients, 24 plaques were identified in the various segments of the intracranial arterial system of which eight appeared normal on MR angiography. Post-contrast enhancement ratio of these plaques varied from 0% up to 156%. CONCLUSIONS: T1 weighted SPACE provides good T1 contrast between intracranial arterial wall and cerebrospinal fluid with high resolution and good coverage within a clinically acceptable scan time. It can depict plaques pre- and post-contrast along the vessels surrounded by cerebrospinal fluid in the intracranial arterial system, and would be a useful tool in the clinical assessment of intracranial arterial diseases.


Assuntos
Encéfalo/patologia , Meios de Contraste , Aumento da Imagem , Imageamento Tridimensional , Arteriosclerose Intracraniana/patologia , Angiografia por Ressonância Magnética , Adulto , Idoso , Encéfalo/irrigação sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/patologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...