Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
J Cardiovasc Surg (Torino) ; 54(3): 373-81, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22820738

RESUMO

AIM: The goal of this study was to identify physical characteristics of primary intimal tears in patients arriving to the hospital alive with acute type A aortic dissection using 64-multislice computerized tomography (MSCT) in order to determine anatomic feasibility of endovascular stent-grafting (ESG) for future treatment. METHODS: Radiology database was screened for acute type A aortic dissection since the time of acquisition of the 64-slice CT scanner and cross-referenced with surgical database. Seventeen patients met inclusion criteria. Images were reviewed for number, location, and size of intimal tears and aortic dimensions. Potential obstacles for ESG were determined. RESULTS: Ascending aorta (29%) and sinotubular junction (29%) were the most frequent regions where intimal tears originated. Location of intimal tears in nearly 75% of patients was inappropriate for ESG, and 94% of patients did not have sufficient proximal or distal landing zone required for secure fixation. Only 71% of patients underwent surgical aortic dissection repair after imaging and 86% of entry tears detected on MSCT were confirmed on intraoperative documentation. Only one patient would have met all technical criteria for ESG using currently available devices. CONCLUSION: Location of intimal tear, aortic valve insufficiency, aortic diameter>38 mm are major factors limiting use of ESG for acute type A dissection. Available stents used to treat type B aortic dissection do not address anatomic constraints present in type A aortic dissection in the majority of cases, such that development of new devices would be required.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Prótese Vascular , Procedimentos Endovasculares , Seleção de Pacientes , Stents , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento , Túnica Íntima/diagnóstico por imagem
2.
J Cardiovasc Surg (Torino) ; 53(5): 631-40, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22820737

RESUMO

AIM: Aortic dissection is a life-threatening aortic catastrophe where layers of the aortic wall are separated allowing blood flow within the layers. Propagation of aortic dissection is strongly linked to the rate of rise of pressure (dp/dt) experienced by the aortic wall but the hemodynamics is poorly understood. The purpose of this study was to perform computational fluid dynamics (CFD) simulations to determine the relationship between dissection propagation in the distal longitudinal direction (the tearing force) and dp/dt. METHODS: Five computational models of aortic dissection in a 2D pipe were constructed. Initiation of dissection and propagation were represented in 4 single entry tear models, 3 of which investigated the role of length of dissection and antegrade propagation, 1 of which investigated retrograde propagation. The 5th model included a distal re-entry tear. Impact of pressure field distribution on tearing force was determined. RESULTS: Tearing force in the longitudinal direction for dissections with a single entry tear was approximately proportional to dp/dt and L2 where L is the length of dissection. Tearing force was much lower under steady flow than pulsatile flow conditions. Introduction of a second tear distally along the dissection away from the primary entry tear significantly reduced tearing force. CONCLUSION: The hemodynamic mechanism for dissection propagation demonstrated in these models support the use of ß-blockers in medical management. Endovascular stent-graft treatment of dissection should ideally cover both entry and re-entry tears to reduce risk of retrograde propagation of aortic dissection.


Assuntos
Aneurisma Aórtico/fisiopatologia , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/fisiopatologia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Hemodinâmica , Modelos Cardiovasculares , Simulação de Dinâmica Molecular , Pressão Sanguínea , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Humanos , Hidrodinâmica , Fluxo Pulsátil , Fluxo Sanguíneo Regional , Stents , Estresse Mecânico
3.
J Cardiovasc Surg (Torino) ; 50(4): 447-60, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19734830

RESUMO

The aim of this paper was to describe the current status of endovascular thoracoabdominal aortic aneurysm (TAAA) repair. This is a comparative review of current device designs and implantation techniques. A literature review of all reported results of endovascular TAAA repair has also been carried out, together with a comparison of clinical outcomes achieved with endovascular TAAA repair and those achieved in current series of standard open TAAA repair. Endovascular TAAA repair has been performed with both unibody and modular devices, but modular devices currently predominate. In modular devices the aortic component provides access to the target visceral artery either through a fenestration or a cuff. Cuffs increase device profile and the length of aorta that is covered, but easily accommodate variations in deployment position and provide a good seal zone. Fenestrations do not affect device profile or add length to the device, but deployment position tolerates little deviation and the seal zone is tenuous. A covered stent is used to bridge the gap between the fenestration or cuff in the aortic component and the target visceral artery. Balloon-expandable covered stent branch extensions are delivered from the femoral approach when fenestrations are used. Self-expanding covered stents are delivered from either the brachial or femoral approach when cuffs are used, depending on the orientation of the cuff. Some groups reinforce the self-expanding covered stent with an uncovered self-expanding stent to enhance flexibility and stability. The majority of endovascular TAAA repairs have been performed in three centers, accounting for 84% of all reported cases. The treated TAAAs were Type 1 31.8%, Type 2 14.2%, Type 3 14.2% and Type 4 37.5%. Perioperative mortality is 6.9% (N. = 20), late mortality 13.6% (N. = 38), spinal cord ischemia (SCI) 14.9% (N. = 29) permanent in 6.7% (N. = 6), transient in 10.0% (N. = 9). Deterioration of renal function was reported in 9.8% (N. = 8), and required initiation of dialysis in 5.1% (N. = 5). Reintervention was required in 18 patients (20.0%) early in 8.9% and late in 11.1%. Branch occlusion developed in 3.5% (N. = 9) and stenosis in 0.85% (N. = 2). Current single-center series of open surgical TAAA repair report mortality rates of 5-16%, spinal cord ischemia rates of 3.8-15.5% and new onset dialysis between 2-16.2%. Population-based series of open surgical TAAA repair report mortality rates between 19.2-26.9%, spinal cord ischemia rates between 7.3-16.0% and new onset dialysis rates of 14.2-18.2%. Final status of SCI neurologic deficit, reintervention rates and branch occlusion or stenosis rates for open TAAA repair are inconsistently available, if at all. In conclusion, endovascular TAAA repair is an evolving technique that is developing increasing consistency in device design and implantation technique. It is effective in eliminating aneurysm flow and in preserving visceral branch perfusion. These early outcomes are better than the results achieved with open TAAA repair in population-based studies and are at least equal to the results of open TAAA repair reported from centers of focused expertise. These results support expanding the indications for endovascular TAAA repair to include standard risk patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Seleção de Pacientes , Stents , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/patologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Constrição Patológica , Medicina Baseada em Evidências , Oclusão de Enxerto Vascular/etiologia , Humanos , Nefropatias/etiologia , Nefropatias/terapia , Desenho de Prótese , Diálise Renal , Reoperação , Medição de Risco , Isquemia do Cordão Espinal/etiologia , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
4.
Ann Vasc Surg ; 22(6): 703-9, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18684589

RESUMO

Thoracic endovascular aortic repair (TEVAR) may involve either planned or inadvertent coverage of aortic branch vessels when stent grafts are implanted into the aortic arch. Vital branch vessels may be preserved by surgical debranching techniques or by placement of additional stents to maintain vessel patency. We report our experience with a double-barrel stent technique used to maintain aortic arch branch vessel patency during TEVAR. Seven patients underwent TEVAR using the double-barrel technique, with placement of branch stents into the innominate (n = 3), left common carotid (n = 3), and left subclavian (n = 1) arteries alongside an aortic stent graft. Gore TAG endografts were used in all cases, and either self-expanding stents (n = 6) or balloon-expandable (n = 1) stents were utilized to maintain patency of the arch branch vessels. In three cases the double-barrel stent technique was used to restore patency of an inadvertently covered left common carotid artery. Four planned cases involved endograft deployment proximally into the ascending aorta with placement of an innominate artery stent (n = 3) and coverage of the left subclavian artery with placement of a subclavian artery stent (n = 1). TEVAR using a double-barrel stent was technically successful with maintenance of branch vessel patency and absence of type I endoleak in all seven cases. One case of zone 0 endograft placement with an innominate stent was complicated by a left hemispheric stroke that was attributed to a technical problem with the carotid-carotid bypass. On follow-up of 2-18 months, all double-barrel branch stents and aortic endografts remained patent without endoleak, migration, or loss of device integrity. The double-barrel stent technique maintains aortic branch patency and provides additional stent-graft fixation length during TEVAR to treat aneurysms involving the aortic arch. Moreover, the technique uses commercially available devices and permits complete aortic arch coverage (zone 0) without a sternotomy. Although initial outcomes are encouraging, long-term durability remains unknown.


Assuntos
Angioplastia com Balão/métodos , Aorta Torácica/cirurgia , Doenças da Aorta/terapia , Implante de Prótese Vascular/métodos , Tronco Braquiocefálico/cirurgia , Artéria Carótida Primitiva/cirurgia , Artéria Subclávia/cirurgia , Idoso , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Doenças da Aorta/cirurgia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Stents , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Grau de Desobstrução Vascular
5.
J Cardiovasc Surg (Torino) ; 47(6): 619-28, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17043607

RESUMO

Open surgical repair of thoracoabdominal aortic aneurysms (TAAA) bridges the aneurysm with a large, conventional, unstented graft and restores flow to the visceral arteries through short grafts or direct sutured connections between the visceral arterial orifices and the primary conduit. The combination of retrograde visceral bypass and endovascular aneurysm exclusion substitutes an endovascular stent-graft for a standard graft, stented overlaps for sutured anastomoses, and transluminal insertion for direct aortic exposure. Compared to open surgery, the combination treatment requires less dissection, and causes less hemodynamic instability, and lower complication rates, particularly paraplegia. The multi-branched stent-graft substitutes endovascular visceral bypass through branches of the stent-graft for surgical visceral bypass through branches of a conventional extraluminal graft, which has the potential to further reduce surgical dissection, hemodynamic instability, and complication rates. We favor a modular approach in which short, axially oriented cuffs are extended into the visceral arteries, using self-expanding covered stents. In the past year, we have used this approach to implant multi-branched thoracoabdominal stent-graft in 16 patients. In our opinion, this approach will eventually assume a prominent role in the management of TAAA.


Assuntos
Angioplastia/métodos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Stents , Angioplastia/efeitos adversos , Angioplastia/história , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/história , História do Século XX , História do Século XXI , Humanos , Desenho de Prótese , Stents/efeitos adversos , Stents/história
6.
Am Surg ; 71(3): 267-8, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15869147

RESUMO

Percutaneous placement of large-diameter dialysis catheters via the Seldinger technique can be technically challenging in patients with coagulopathy, difficult anatomy, or several previous central line insertions. We describe a method for achieving safer access by combining an open approach to delineate the venous anatomy of the chest wall, with a micropuncture device and smaller diameter guidewire to gain intravascular access to the cephalic vein or its major tributaries. Serial dilation of otherwise unusable vessels can then permit successful and safer hemodialysis catheter insertion in these difficult cases.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Diálise Renal/métodos , Derivação Arteriovenosa Cirúrgica/instrumentação , Cateterismo , Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/métodos , Terapia Combinada , Desenho de Equipamento , Segurança de Equipamentos , Humanos , Punções , Diálise Renal/instrumentação , Medição de Risco , Sensibilidade e Especificidade
7.
Vasa ; 33(2): 68-71, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15224457

RESUMO

BACKGROUND: The purpose of this study was to compare the anatomy of the aortoiliac vessels in patients scheduled for infrarenal abdominal aortic aneurysm (AAA) repair in four different countries. MATERIAL AND METHODS: Consecutives series of 100 preoperative CT-scans were evaluated at each center. Diameters of the suprarenal aorta, maximal diameter of the aneurysm, right and left common and external iliac artery as well as the hypogastric arteries were recorded and compared between each center. RESULTS: Configuration of the AAA above bifurcation was similar at each center. The dimensions of the aortic bifurcation and the common iliac arteries were different among the centers. Common iliac arteries with diameters over 25 mm were significantly more common at center 1 (p < 0.001, p = 0.002 and p < 0.001). Among centers 2, 3 and 4 there was no significant difference in common iliac diameters. CONCLUSIONS: Configuration of the iliac arteries in AAA was significantly different for Swiss patients compared to American, Austrian and German patients. Reasons for these differences are unclear, epidemiological or genetic factors may be responsible.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Artéria Ilíaca/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/patologia , Áustria/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Alemanha/epidemiologia , Humanos , Artéria Ilíaca/patologia , Incidência , Masculino , Pessoa de Meia-Idade , Radiografia , Medição de Risco/métodos , Fatores de Risco , Suíça/epidemiologia , Estados Unidos/epidemiologia
8.
J Cardiovasc Surg (Torino) ; 44(4): 519-25, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-14627224

RESUMO

The aim of this study was to explain variations in the results of endovascular aneurysm repair as a consequences of device design. Low profile, trackable systems, such as Zenith and Excluder, rarely fail to traverse the iliac arteries, even in the presence of iliac tortuosity or stenosis. In most patients, optimal sizing is only possible with systems, such as Zenith, Talent, and Quantum lp, that have a wide range of diameters. Short, angulated necks call for a high degree of flexibility and secure, barb-enhanced proximal fixation, which are features of Excluder, Zenith and Ancure. The main risk factors for rupture are migration, type III endoleak, and aneurysm dilatation. Migration rates are high for devices, such as AneuRx, that have neither barbs nor suprarenal stents. Aneurysm shrinkage occurs at high rates with non-porous stent-grafts, such as Zenith, Talent, and Ancure, but at far lower rates with porous stent-grafts, such as Excluder and AneuRx. Type III endoleak, due to fabric failure or component separation, was a common failure mode for the Vanguard device, but is rare with newer devices. Suture breakage, barb separation and stent breakage occur frequently, yet clinical consequences, such as endoleak or rupture, are rare. Graft thrombosis is also unusual when the prostheses is fully-stented. In conclusion, modern devices are more versatile, more effective, and more durable than their first generation counterparts.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Stents , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Falha de Equipamento , Migração de Corpo Estranho , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Desenho de Prótese , Falha de Prótese , Stents/efeitos adversos
10.
J Vasc Surg ; 34(1): 98-105, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11436081

RESUMO

PURPOSE: We sought to assess the role of endovascular techniques in the management of perigraft flow (endoleak) after endovascular repair of an abdominal aortic aneurysm. METHOD: We performed endovascular repair of abdominal aortic aneurysm in 114 patients, using a variety of Gianturco Z-stent-based prostheses. Results were evaluated with contrast-enhanced computed tomography (CT) at 3 days, 3 months, 6 months, 12 months, and every year after the operation. An endoleak that occurred 3 days after operation led to repeat CT scanning at 2 weeks, followed by angiography and attempted endovascular treatment. RESULTS: Endoleak was seen on the first postoperative CT scan in 21 (18%) patients and was still present at 2 weeks in 14 (12%). On the basis of angiographic localization of the inflow, the endoleak was pure type I in 3 cases, pure type II in 9, and mixed-pattern in 2. Of the 5 type I endoleaks, 3 were proximal and 2 were distal. All five resolved after endovascular implantation of additional stent-grafts, stents, and embolization coils. Although inferior mesenteric artery embolization was successful in 6 of 7 cases and lumbar embolization was successful in 4 of 7, only 1 of 11 primary type II endoleaks was shown to be resolved on CT scanning. There were no type III or type IV endoleaks (through the stent-graft). Endoleak was associated with aneurysm dilation two cases. In both cases, the aneurysm diameter stabilized after coil embolization of the inferior mesenteric artery. There were two secondary (delayed) endoleaks; one type I and one type II. The secondary type I endoleak and the associated aneurysm rupture were treated by use of an additional stent-graft. The secondary type II endoleak was not treated. CONCLUSIONS: Type I endoleaks represent a persistent risk of aneurysm rupture and should be treated promptly by endovascular means. Type II leaks are less dangerous and more difficult to treat, but coil embolization of feeding arteries may be warranted when leakage is associated with aneurysm enlargement.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Complicações Pós-Operatórias , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Embolização Terapêutica , Humanos , Artéria Mesentérica Superior/diagnóstico por imagem , Complicações Pós-Operatórias/terapia , Intensificação de Imagem Radiográfica , Stents , Tomografia Computadorizada por Raios X
11.
Radiology ; 220(1): 157-60, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11425989

RESUMO

PURPOSE: To determine the spectrum and frequency of specific computed tomographic (CT) findings in the acute period after endovascular repair of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: CT images obtained 1--3 days after endograft placement were evaluated in 88 patients. The images were analyzed for stent position, appearance of endograft components, perigraft leak, and postoperative findings including air and acute thrombus within the aneurysm and air surrounding the femoral-femoral bypass graft. Findings that could be misinterpreted as perigraft leak were evaluated. RESULTS: Fifteen (17%) of 88 patients had perigraft leak in the acute postoperative period. The bare segment of the proximal self-expanding stent covered one or both renal arteries in 54 (61%) patients. One patient had CT evidence of renovascular compromise. Postoperative air was within the aneurysmal sac in 51 (58%) patients and surrounded the femoral-femoral bypass graft in 67 (94%) of 71 patients in whom the grafts were evaluated with CT. Mottled attenuation within the aneurysmal sac was seen in 50 (57%) patients. Forty-six (52%) patients had calcifications within longstanding thrombus. In 31 (35%) patients, findings that could have been misinterpreted as perigraft leak were identified. CONCLUSION: Accurate analysis of CT findings after endovascular AAA repair requires careful review of all available CT images (preprocedural and pre- and postcontrast) and clear understanding of specific stent-graft components and placement.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/terapia , Cateterismo/instrumentação , Stents , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Cateterismo/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Sensibilidade e Especificidade
13.
J Vasc Surg ; 33(2 Suppl): S157-64, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11174829

RESUMO

PURPOSE: To evaluate the initial and mid-term results of the Zenith endovascular grafting system for infrarenal abdominal aortic aneurysms. METHODS: Prospective databases at seven centers were used to assess a cohort of patients that underwent treatment for aortic, aortoiliac, or iliac aneurysms since 1995. Data were analyzed to yield descriptive characteristics that pertained to the patients, the aortic morphologic features, the graft configuration, and the complications. Follow-up imaging data were used to determine size changes of the aneurysm sac, endoleak rates, and further complications. Finally survival data were expressed with a Kaplan-Meier analysis. RESULTS: A total of 528 patients were treated with the Zenith endograft. Most of the patients (66%) were considered to be at a high physiologic risk for open repair. Successful graft implantation was accomplished in all but four patients. An overall endoleak rate of 15% was noted, of which 4% was treated urgently because they were thought to represent attachment site faults. The mean follow-up period was 18 months. A total of eight endograft migrations were detected after 2 years of follow-up with an early version of the system. There were three late conversions; two ruptures occurred during the follow-up period. CONCLUSION: This early and mid-term data support the use of the Zenith endovascular graft for the treatment of aortic and aortoiliac aneurysms in properly selected patients. The risks of significant complications or aneurysm rupture are low.


Assuntos
Angioplastia/instrumentação , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/normas , Stents/normas , Angioplastia/efeitos adversos , Aneurisma da Aorta Abdominal/classificação , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular/efeitos adversos , Comorbidade , Seguimentos , Humanos , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Radiografia , Fatores de Risco , Índice de Gravidade de Doença , Stents/efeitos adversos , Análise de Sobrevida , Resultado do Tratamento
14.
J Endovasc Ther ; 8(1): 25-33, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11220464

RESUMO

PURPOSE: To describe a stent-graft system for endovascular repair of thoracoabdominal aortic aneurysm (TAAA) that preserves side branch perfusion. TECHNIQUE: The modular endograft system includes 3 components. The primary stent-graft is custom-made from conventional graft fabric and Gianturco Z-stents. Covered nitinol Smart Stents are used for the visceral and renal extensions, and the distal extension is made from a modified Zenith system. With the supine patient under general anesthesia, the components are delivered sequentially through surgically exposed femoral and right brachial arteries in an operation that requires prolonged periods of magnified high-resolution imaging. This system was first used in a 76-year-old man with a contained rupture of a supraceliac ulcer and a large abdominal aortic aneurysm ending proximally at the celiac artery. The endograft was implanted successfully, but the patient developed paraplegia on day 2; imaging documented an excluded aneurysm and excellent flow through the endograft and all prosthetic branches. DISCUSSION: Endovascular repair of TAAA appears to be feasible. If there are no serious, specific, unavoidable complications, the potential advantages are enormous.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Procedimentos Cirúrgicos Vasculares , Aorta/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Torácica/patologia , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia , Desenho de Equipamento , Humanos , Fluxo Sanguíneo Regional , Stents , Tomografia Computadorizada por Raios X
15.
J Endovasc Ther ; 7(4): 286-91, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10958292

RESUMO

PURPOSE: To report the endovascular treatment of abdominal aortic aneurysms (AAA) in 2 patients with pelvic renal transplants. METHODS AND RESULTS: Two men with multiple comorbidities and pelvic transplant kidneys underwent endovascular AAA repair using an aortomonoiliac system with femorofemoral bypass grafting. The arterial end-to-side anastomosis in both patients was to the external iliac artery. Tapered aortomonoiliac grafts were fashioned from Gianturco Z-stents covered with Dacron graft material and implanted with the distal attachment site in the iliac system ipsilateral to the transplant kidney arterial anastomosis. The body of the stent-graft was reinforcement with a Wallstent in each case before the contralateral common iliac artery was occluded and the cross-femoral bypass constructed. Both patients recovered uneventfully from the procedure and are free of endoleak or other complications related to their aneurysm repair at 7 and 34 months. CONCLUSIONS: The presence of a pelvic renal transplant in a patient undergoing endovascular AAA repair increases the complexity of procedural planning and endograft implantation, but a good outcome can be achieved.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Transplante de Rim , Stents , Idoso , Anastomose Cirúrgica/métodos , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/métodos , Artéria Femoral/cirurgia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Masculino , Pessoa de Meia-Idade , Artéria Renal/diagnóstico por imagem , Artéria Renal/cirurgia , Tomografia Computadorizada por Raios X
16.
J Endovasc Ther ; 7(3): 240-4, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10883963

RESUMO

PURPOSE: To describe a case of presumed aortoduodenal fistula that was treated by endovascular implantation of a stent-graft. METHODS AND RESULTS: A 76-year-old man was transferred from another hospital where he had been treated for upper gastrointestinal hemorrhage over a 2-month period. Ten years previously, he had undergone aortobifemoral bypass, the right limb of which recently thrombosed. At the time of transfer, computed tomographic scanning showed a large false aneurysm between the aorta and the duodenum. Endoscopy disclosed mucosal erosions in the fourth portion of the duodenum. Following implantation of 2 overlapping stent-grafts, the bleeding ceased and the false aneurysm disappeared. At no time did the patient have a fever. The patient initially did well, but 8 months after treatment, he presented with fever and chills. Recurrent infection had caused erosion of the aorta so that a large portion of the stent-graft was visible from the duodenum. The infected graft and stent-grafts were removed in a two-part operation, from which the patient recovered satisfactorily. CONCLUSIONS: Endovascular stent-grafts may have a role to play in the management of aortoduodenal fistula, if only as a temporary measure to control bleeding.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Duodeno , Hemorragia Gastrointestinal/etiologia , Fístula Intestinal/complicações , Infecção da Ferida Cirúrgica/complicações , Fístula Vascular/cirurgia , Idoso , Falso Aneurisma/complicações , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Angiografia , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Diagnóstico Diferencial , Duodenoscopia , Seguimentos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/cirurgia , Humanos , Fístula Intestinal/diagnóstico , Fístula Intestinal/cirurgia , Masculino , Reoperação , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/cirurgia , Tomografia Computadorizada por Raios X , Fístula Vascular/complicações , Fístula Vascular/diagnóstico por imagem
18.
J Vasc Surg ; 31(1 Pt 1): 122-33, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10642715

RESUMO

PURPOSE: The purpose of this study was to evaluate the role of endovascular aneurysm repair in high-risk patients. METHODS: The elective endovascular repair of infrarenal aortic aneurysm was performed in 116 high-risk patients with either custom-made or commercial stent grafts. The routine follow-up examination included contrast-enhanced computed tomography (CT) before discharge, at 3, 6, and 12 months, and annually thereafter. Patients with endoleak on the initial CT underwent re-evaluation at 2 weeks. Those patients with positive CT results at 2 weeks underwent endovascular treatment. RESULTS: Endovascular repair was considered feasible in 67% of the patients. The mean age was 75 years, and the mean aneurysm diameter was 6.3 cm. The American Society of Anesthesiologists grade was II in 3.4%, III in 65.5%, IV in 30.1%, and V in 0.9%. There were no conversions to open repair. Custom-made aortomonoiliac stent grafts were implanted in 77.6% of the cases, custom-made aortoaotic stent grafts in 11.2%, and commercial bifurcated stent grafts in 11.2%. The 30-day rates of mortality, major morbidity, and minor morbidity were 3.4%, 20.7%, and 12%, respectively, in the first 58 patients and 0%, 3.4%, and 3.4%, respectively, in the last 58. The late complications included five cases of stent graft kinking, two cases of femorofemoral graft occlusion, and three cases of proximal stent migration, one of which led to aneurysm rupture. At 2 weeks after repair, endoleak was present in 10.3% of the cases. All the type I (direct perigraft) endoleaks underwent successful endovascular treatment, whereas only one type II (collateral) endoleak responded to treatment. The technical success rate at 2 weeks was 86.2%, and the clinical success rate was 96.6%. The continuing success rate was 87.9%. Seventeen patients died late, unrelated deaths. CONCLUSION: Endovascular aneurysm repair is safe and effective in patients at high risk, for whom it may be the preferred method of treatment.


Assuntos
Angioplastia/instrumentação , Angioplastia/métodos , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Stents , Idoso , Angiografia , Angioplastia/efeitos adversos , Angioplastia/mortalidade , Aneurisma da Aorta Abdominal/classificação , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Comorbidade , Seguimentos , Humanos , Seleção de Pacientes , Modelos de Riscos Proporcionais , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Stents/efeitos adversos , Análise de Sobrevida , Técnicas de Sutura , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
Semin Vasc Surg ; 12(3): 176-81, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10498260

RESUMO

The relative merits of aortomonoiliac and bifurcated stent-graft configurations depend on the patient's arterial anatomy and clinical status. Aortomonoiliac stent-grafts are simple to make, simple to insert, and versatile. They are most useful when the iliac artery anatomy is severely distorted and the patient is old, sick, and inactive. The main problems with this approach are all consequences of femorofemoral bypass. The bifurcated stent-graft is the preferred alternative in healthy patients, because it ensures flow to both common iliac arteries, thereby eliminating the need for femorofemoral bypass. However, bifurcated stent-grafts and their delivery systems are difficult to make and difficult to deploy, especially when the iliac anatomy is distorted or emergency circumstances preclude preoperative sizing. This article addresses the advantages and disadvantages of the aortomonoiliac graft.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Artéria Femoral/cirurgia , Artéria Ilíaca/cirurgia , Stents , Humanos , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA