Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 132
Filtrar
1.
Healthcare (Basel) ; 12(2)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38255064

RESUMO

Somatic dysfunction (SD) is an altered body function involving the musculoskeletal system. However, its clinical signs-tissue texture abnormalities, positional asymmetry, restricted range of motion, and tissue tenderness-did not achieve satisfactory results for reliability. A recent theoretical model proposed a revision assessing the movement variability around the joint rest position. The asymmetry and restriction of motion may characterize functional assessment in osteopathic clinical practice, demonstrating the reliability required. Hence, this study investigated the reliability of the new variability model (VM) with gait analysis (GA). Three blind examiners tested 27 young healthy subjects for asymmetry of motion around rest position and the SD grade on six body regions. The results were compared to the VICON procedure for 3D-GA. The inter-rater agreement for the detection of reduced movement variability ranged from 0.78 to 0.54, whereas for SD, grade ranged from 0.64 to 0.47. VM had a sensitivity and specificity of 0.62 and 0.53, respectively, in SD detection compared to step length normality. Global severity grade of SD demonstrated moderate to good correlation with spatial-temporal parameters. The VM showed palpatory reliability and validity with spatial-temporal parameters in GA. Those findings contribute to the innovation for SD examination with implications for the clinical practice.

2.
Sensors (Basel) ; 23(22)2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-38005650

RESUMO

In recent years, wearable systems based on inertial sensors opened new perspectives for functional motor assessment with respect to the gold standard motion capture systems. The aim of this study was to validate an experimental set-up based on 17 body-worn inertial sensors (Awinda, Xsens, The Netherlands), addressing specific body segments with respect to the state-of-the art system (VICON, Oxford Metrics Ltd., Oxford, UK) to assess upper limb kinematics in obese, with respect to healthy subjects. Twenty-three obese and thirty healthy weight individuals were simultaneously acquainted with the two systems across a set of three tasks for upper limbs (i.e., frontal arm rise, lateral arm rise, and reaching). Root Mean Square error (RMSE) was computed to quantify the differences between the measurements provided by the systems in terms of range of motion (ROM), whilst their agreement was assessed via Pearson's correlation coefficient (PCC) and Bland-Altman (BA) plots. In addition, the signal waveforms were compared via one-dimensional statistical parametrical mapping (SPM) based on a paired t-test and a two-way ANOVA was applied on ROMs. The overall results partially confirmed the correlation and the agreement between the two systems, reporting only a moderate correlation for shoulder principal rotation angle in each task (r~0.40) and for elbow/flexion extension in obese subjects (r = 0.66), whilst no correlation was found for most non-principal rotation angles (r < 0.40). Across the performed tasks, an average RMSE of 34° and 26° was reported in obese and healthy controls, respectively. At the current state, the presence of bias limits the applicability of the inertial-based system in clinics; further research is intended in this context.


Assuntos
Ombro , Extremidade Superior , Humanos , Cotovelo , Obesidade , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Rotação
3.
Sensors (Basel) ; 23(13)2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-37447862

RESUMO

Inertial technology has spread widely for its comfortable use and adaptability to various motor tasks. The main objective of this study was to assess the validity of inertial measurements of the cervical spine range of motion (CROM) when compared to that of the optoelectronic system in a group of healthy individuals. A further aim of this study was to determine the optimal placement of the inertial sensor in terms of reliability of the measure, comparing measurements obtained from the same device placed at the second cervical vertebra (C2), the forehead (F) and the external occipital protuberance (EOP). Twenty healthy subjects were recruited and asked to perform flexion-extension, lateral bending, and axial rotation movements of the head. Outcome measurements of interest were CROM and mean angular velocities for each cervical movement. Results showed that inertial measurements have good reliability (0.75 < ICC < 0.9). Excellent reliability (ICC > 0.9) was found in both flexion and right lateral bending angles. All parameters extracted with EOP placement showed ICC > 0.62, while ICC < 0.5 was found in lateral bending mean angular velocities both for F and C2 placements. Therefore, the optimal sensor's positioning emerged to be EOP. These results suggest that inertial technology could be useful and reliable for the evaluation of the CROM.


Assuntos
Vértebras Cervicais , Pescoço , Humanos , Reprodutibilidade dos Testes , Amplitude de Movimento Articular , Movimento
4.
Sensors (Basel) ; 23(13)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37448005

RESUMO

In recent years, the use of inertial-based systems has been applied to remote rehabilitation, opening new perspectives for outpatient assessment. In this study, we assessed the accuracy and the concurrent validity of the angular measurements provided by an inertial-based device for rehabilitation with respect to the state-of-the-art system for motion tracking. Data were simultaneously collected with the two systems across a set of exercises for trunk and lower limbs, performed by 21 healthy participants. Additionally, the sensitivity of the inertial measurement unit (IMU)-based system to its malpositioning was assessed. Root mean square error (RMSE) was used to explore the differences in the outputs of the two systems in terms of range of motion (ROM), and their agreement was assessed via Pearson's correlation coefficient (PCC) and Lin's concordance correlation coefficient (CCC). The results showed that the IMU-based system was able to assess upper-body and lower-limb kinematics with a mean error in general lower than 5° and that its measurements were moderately biased by its mispositioning. Although the system does not seem to be suitable for analysis requiring a high level of detail, the findings of this study support the application of the device in rehabilitation programs in unsupervised settings, providing reliable data to remotely monitor the progress of the rehabilitation pathway and change in patient's motor function.


Assuntos
Terapia por Exercício , Telerreabilitação , Humanos , Fenômenos Biomecânicos , Exercício Físico , Amplitude de Movimento Articular
5.
Bioengineering (Basel) ; 10(6)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37370581

RESUMO

The COVID-19 pandemic brought new challenges to global healthcare systems regarding the care of acute patients and the delivery of rehabilitation programs to post-acute or chronic patients. Patients who survive severe forms of COVID-19 often report incomplete healing and long-term symptoms. The need of these patients for rehabilitation has been recognized as a public health problem. In this context, the application of tele-rehabilitation has been explored to reduce the burden on healthcare systems. The purpose of this narrative review is to present an overview of the state of the art regarding the application of remote motor rehabilitation programs for paucisymptomatic acute and post-acute COVID-19 patients, with a focus on the motor aspects of tele-rehabilitation. Following an extensive search on PubMed, the Web of Science, and Scopus, specific studies have been reviewed and compared in terms of study objectives and participants, experimental protocols and methods for home-based interventions, functional assessment, and rehabilitation outcomes. Overall, this review suggests the feasibility and the effectiveness of tele-rehabilitation as a promising tool to complement face-to-face rehabilitation interventions. However, further improvements are needed to overcome the limitations and the current lack of knowledge in the field.

6.
Sensors (Basel) ; 23(6)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36991886

RESUMO

Obesity has a critical impact on musculoskeletal systems, and excessive weight directly affects the ability of subjects to realize movements. It is important to monitor the activities of obese subjects, their functional limitations, and the overall risks related to specific motor tasks. From this perspective, this systematic review identified and summarized the main technologies specifically used to acquire and quantify movements in scientific studies involving obese subjects. The search for articles was carried out on electronic databases, i.e., PubMed, Scopus, and Web of Science. We included observational studies performed on adult obese subjects whenever reporting quantitative information concerning their movement. The articles must have been written in English, published after 2010, and concerned subjects who were primarily diagnosed with obesity, thus excluding confounding diseases. Marker-based optoelectronic stereophotogrammetric systems resulted to be the most adopted solution for movement analysis focused on obesity; indeed, wearable technologies based on magneto-inertial measurement units (MIMUs) were recently adopted for analyzing obese subjects. Further, these systems are usually integrated with force platforms, so as to have information about the ground reaction forces. However, few studies specifically reported the reliability and limitations of these approaches due to soft tissue artifacts and crosstalk, which turned out to be the most relevant problems to deal with in this context. In this perspective, in spite of their inherent limitations, medical imaging techniques-such as Magnetic Resonance Imaging (MRI) and biplane radiography-should be used to improve the accuracy of biomechanical evaluations in obese people, and to systematically validate less-invasive approaches.


Assuntos
Obesidade , Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Reprodutibilidade dos Testes , Movimento , Imageamento por Ressonância Magnética
7.
Front Public Health ; 11: 1121243, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36817927

RESUMO

Introduction: Digital transformation and technological innovation which have influenced several areas of social and productive life in recent years, are now also a tangible and concrete reality in the vast and strategic sector of public healthcare. The progressive introduction of digital technologies and their widespread diffusion in many segments of the population undoubtedly represent a driving force both for the evolution of care delivery methods and for the introduction of new organizational and management methods within clinical structures. Methods: The CS Clinical Engineering of the "Spedali Civili Hospital in Brescia" decided to design a path that would lead to the development of a software for the management of biomedical technologies within its competence inside the hospital. The ultimate aim of this path stems from the need of Clinical Engineering Department to have up-to-date, realistic, and systematic control of all biomedical technologies present in the company. "Spedali Civili Hospital in Brescia" is not just one of the most important corporate realities in the city, but it is also the largest hospital in Lombardy and one of the largest in Italy. System development has followed the well-established phases: requirement analysis phase, development phase, release phase and evaluating and updating phase. Results: Finally, cooperation between the various figures involved in the multidisciplinary working group led to the development of an innovative management software called "SIC Brescia". Discussion: The contribution of the present paper is to illustrate the development of a complex implementation model for the digitization of processes, information relating to biomedical technologies and their management throughout the entire life cycle. The purpose of sharing this path is to highlight the methodologies followed for its realization, the results obtained and possible future developments. This may enable other realities in the healthcare context to undertake the same type of pathway inspired by an accomplished model. Furthermore, future implementation and data collection related to the proposed Key Performance Indicators, as well as the consequent development of new operational management models for biomedical technologies and maintenance processes will be possible. In this way, the Clinical Risk Management concept will also be able to evolve into a more controlled, safe, and efficient system for the patient and the user.


Assuntos
Engenharia Biomédica , Tecnologia Biomédica , Humanos , Hospitais , Atenção à Saúde , Itália
8.
Multimed Tools Appl ; 82(7): 11079-11098, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36118187

RESUMO

Recent developments in 3D graphic technologies enable the affordable and precise reconstruction of body scanned models that can be applied in a variety of verticals, such as fashion, fitness and wellness, and healthcare. The accuracy of body measurements is a crucial element for the successful application of avatars in the following use cases: Avatars that go beyond visual representation and offer intrinsic and precise anthropometric data defined as a smart body are discussed in this paper. In particular, this paper presents the Gate technology, an innovative, autonomous, sustainable body scanner, coupled with an automatic production pipeline and the concept of avatars as smart bodies. We present an accuracy study of scanning technology for scanning inanimate objects, as well as body parts versus the ground, by using an established accuracy scanning system. The results appear to be promising and confirm the hypothesis of applying the technology to the use cases discussed as well as broadening the research to other studies and future applications.

9.
Physiother Theory Pract ; : 1-11, 2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-36384401

RESUMO

BACKGROUND: Individuals with Down syndrome (DS) require more time to develop motor and/or cognitive skills. Neuromodulation is used to assist in this development. However, there is a gap in the literature on neurophysiological changes that may occur in the primary motor cortex in individuals with DS following neuromodulation. OBJECTIVE: Our objective was to investigate possible neurophysiological changes in brain wave behavior of the primary motor cortex following the administration of anodal transcranial direct current stimulation combined with sensorimotor training. METHODS: The study involved 12 participants with DS. EEG equipment was used to investigate brain activity. The participants received neuromodulation involving anodal tDCS for 20 minutes with a current of 1 mA combined with virtual reality (VR) training three times a week for a total of ten sessions. We analyzed EGG signals and 3D movement during a reaching movement of the dominant upper limb before and after the ten-session protocol. RESULTS: Significant differences in event-related desynchronization and event-related synchronization of the alpha and beta rhythms were found throughout the evaluations. Brain mapping revealed reductions in power and frequency, demonstrating changes in the patterns of these rhythms in the cerebral cortex. Revealed reorganization of the behavior of alpha and beta waves, as demonstrated by distribution of synchronization and desynchronization of these waves among the regions of the brain. CONCLUSION: The results suggest that anodal tDCS promotes the reorganization of brain impulses, redirecting these impulses to the required regions more efficiently and contributing to better motor planning.

10.
Sensors (Basel) ; 22(13)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35808426

RESUMO

The aim of this review was to present an overview of the state of the art in the use of the Microsoft Kinect camera to assess gait in post-stroke individuals through an analysis of the available literature. In recent years, several studies have explored the potentiality, accuracy, and effectiveness of this 3D optical sensor as an easy-to-use and non-invasive clinical measurement tool for the assessment of gait parameters in several pathologies. Focusing on stroke individuals, some of the available studies aimed to directly assess and characterize their gait patterns. In contrast, other studies focused on the validation of Kinect-based measurements with respect to a gold-standard reference (i.e., optoelectronic systems). However, the nonhomogeneous characteristics of the participants, of the measures, of the methodologies, and of the purposes of the studies make it difficult to adequately compare the results. This leads to uncertainties about the strengths and weaknesses of this technology in this pathological state. The final purpose of this narrative review was to describe and summarize the main features of the available works on gait in the post-stroke population, highlighting similarities and differences in the methodological approach and primary findings, thus facilitating comparisons of the studies as much as possible.


Assuntos
Hemiplegia , Acidente Vascular Cerebral , Fenômenos Biomecânicos , Marcha , Humanos , Extremidade Inferior , Acidente Vascular Cerebral/complicações
11.
Brain Sci ; 12(6)2022 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-35741683

RESUMO

Brain asymmetry is connected with motor performance, suggesting that hemiparetic patients have different gait patterns depending on the side of the lesion. This retrospective cohort study aims to further investigate the difference between right and left hemiplegia in order to assess whether the injured side can influence the patient's clinical characteristics concerning gait, thus providing insights for new personalized rehabilitation strategies. The data from 33 stroke patients (17 with left and 16 with right hemiplegia) were retrospectively compared with each other and with a control group composed of 20 unaffected age-matched individuals. The 3D gait analysis was used to assess kinematic data and spatio-temporal parameters. Compared to left hemiplegic patients, right hemiplegic patients showed worse spatio-temporal parameters (p < 0.05) and better kinematic parameters (p < 0.05). Both pathological groups were characterized by abnormal gait parameters in comparison with the control group (p < 0.05). These findings show an association between the side of the lesion­right or left­and the different stroke patients' gait patterns: left hemiplegic patients show better spatio-temporal parameters, whereas right hemiplegic patients show better segmentary motor performances. Therefore, further studies may develop and assess new personalized rehabilitation strategies considering the injured hemisphere and brain asymmetry.

12.
Phys Ther ; 102(8)2022 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-35689805

RESUMO

OBJECTIVE: The aim of this study was to assess the effects of applying transcranial direct-current stimulation (tDCS), a footdrop stimulator (FDS), and gait training simultaneously on functional mobility in people with chronic hemiparesis after stroke. METHODS: In this double-blind controlled trial, 32 individuals with mild, moderate, and severe chronic hemiparesis after stroke were randomized to tDCS plus FDS or sham tDCS plus FDS groups. Both groups underwent 10 concurrent tDCS and FDS gait training sessions 5 times per week for 2 weeks. Functional mobility was evaluated by the Timed "Up & Go" test (TUG). Secondary outcomes included spasticity of plantarflexors, knee extensors, and hip adductors; quality of life; and walking endurance (distance covered during each treadmill gait training session). Clinical assessments were performed before treatment, after treatment, and at a 1-month follow-up. A generalized estimating equation was used to compare the effects of time, group, and time × group interaction. RESULTS: No difference between groups was observed during performance of the TUG or other outcomes. TUG performance was improved in both the tDCS plus FDS group (before treatment = 24.29 [95% CI = 17.72-33.28]; after treatment = 21.75 [95% CI = 15.75-30.08]) and the sham tDCS plus FDS group (before treatment = 19.63 [95% CI = 16.06-23.0]; after treatment = 18.45 [95% CI = 15.26-22.3]). This improvement remained at the follow-up evaluation. Both groups also showed reduced spasticity of plantarflexors and knee extensors, increased quality of life, and increased total distance walked. CONCLUSION: This study provided no evidence that bicephalic tDCS improves functional mobility, spasticity, quality of life, or walking endurance in people with chronic hemiparesis after stroke. IMPACT: Bicephalic tDCS does not add relevant benefits to FDS and gait training in people who have chronic hemiparesis after stroke. Given that tDCS has few additional effects and given its costs for clinical practice, tDCS for rehabilitation in people with chronic hemiparesis after stroke is discouraged. FDS and gait training improve functional mobility, walking resistance, and quality of life in people with chronic hemiparesis after stroke.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Estimulação Transcraniana por Corrente Contínua , Método Duplo-Cego , Humanos , Paresia , Qualidade de Vida , Resultado do Tratamento
13.
Sensors (Basel) ; 22(10)2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35632128

RESUMO

Quantitative movement analysis is widely used in clinical practice and research to objectively and thoroughly investigate movement disorder [...].


Assuntos
Movimento , Dispositivos Eletrônicos Vestíveis , Atenção à Saúde
14.
Artigo em Inglês | MEDLINE | ID: mdl-35206189

RESUMO

The emergency caused by the escalation in the COVID-19 pandemic, which became widespread starting on 31 January 2020, put a strain on the Italian National Health System and forced purchasing centres to deviate from the ordinary general principles dictated by current legislation. The aim of this paper is to describe how Spedali Civili Hospital in Brescia challenged the crisis, structured itself optimally, followed simplified procedures, launched new processes, and opened up more Intensive Care Unit beds to accommodate the high number of COVID cases. From an analysis of the equipment variation in terms of increased purchases, subsequent installations, and tests carried out compared with the pre-pandemic period, we report the difficulties that hospitals had to face in the first phase of the pandemic and how they were able to respond to their needs. Our data clearly displayed how the pandemic situation led to a deep internal reorganisation and that the drafting of simpler, effective, and adaptable procedures represents a first key element to ensure receptivity and responsiveness in the management of ordinary and non-ordinary events such as this pandemic condition.


Assuntos
COVID-19 , Pandemias , COVID-19/epidemiologia , Hospitais , Humanos , Assistência Médica , SARS-CoV-2
15.
Sensors (Basel) ; 22(3)2022 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-35161528

RESUMO

Walking remains a highly recommended form of exercise for the management of obesity. Thus, comfortable and adequate shoes represent, together with the prescription of a safe adapted physical activity, an important means to achieve the recommended physical activity target volume. However, the literature on shoes specific for obese individuals is inadequate. The aim of the present study was to compare the performance of shoes specifically designed for subjects with obesity with everyday sneakers during instrumented 6-min walking test and outdoor 30-min ambulation in a group of subjects with obesity using a single wearable device. Twenty-three obese individuals (mean age 58.96 years) were recruited and classified into two groups: deconditioned (n = 13) and non-deconditioned patients (n = 10). Each participant was evaluated with his/her daily sneakers and the day after with shoes specifically designed for people with obesity by means of a questionnaire related to the comfort related to each model of shoes and instrumentally during the i6MWT and an outdoor walking test. The results showed that the specifically designed shoes displayed the higher score as for comfort, in particular in the deconditioned group. During the i6MWT, the distance walked, and step length significantly increased in the deconditioned group when specifically designed shoes were worn; no significant changes were observed in the non-deconditioned individuals. The deconditioned group displayed longer step length during the outdoor 30-min ambulation test. In the non-deconditioned group, the use of specific shoes correlated to better performance in terms of gait speed and cadence. These data, although preliminary, seem to support the hypothesis that shoes specifically conceived and designed for counteracting some of the known functional limitations in subjects with obesity allow for a smoother, more stable and possibly less fatiguing gait schema over time.


Assuntos
Sapatos , Caminhada , Adaptação Fisiológica , Feminino , Marcha , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade
16.
Sensors (Basel) ; 22(3)2022 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-35161570

RESUMO

The accurate and reliable assessment of gait parameters is assuming an important role, especially in the perspective of designing new therapeutic and rehabilitation strategies for the remote follow-up of people affected by disabling neurological diseases, including Parkinson's disease and post-stroke injuries, in particular considering how gait represents a fundamental motor activity for the autonomy, domestic or otherwise, and the health of neurological patients. To this end, the study presents an easy-to-use and non-invasive solution, based on a single RGB-D sensor, to estimate specific features of gait patterns on a reduced walking path compatible with the available spaces in domestic settings. Traditional spatio-temporal parameters and features linked to dynamic instability during walking are estimated on a cohort of ten parkinsonian and eleven post-stroke subjects using a custom-written software that works on the result of a body-tracking algorithm. Then, they are compared with the "gold standard" 3D instrumented gait analysis system. The statistical analysis confirms no statistical difference between the two systems. Data also indicate that the RGB-D system is able to estimate features of gait patterns in pathological individuals and differences between them in line with other studies. Although they are preliminary, the results suggest that this solution could be clinically helpful in evolutionary disease monitoring, especially in domestic and unsupervised environments where traditional gait analysis is not usable.


Assuntos
Transtornos Neurológicos da Marcha , Doença de Parkinson , Marcha , Análise da Marcha , Transtornos Neurológicos da Marcha/diagnóstico , Humanos , Doença de Parkinson/diagnóstico , Caminhada
17.
Trials ; 23(1): 87, 2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35090554

RESUMO

BACKGROUND: Children with Down syndrome have poorer functional and sensory skills compared to children with typical development. Virtual reality (VR) training could help improve these skills. Moreover, transcranial direct current stimulation (tDCS) has achieved promising results in terms of enhancing the effects of physical and sensory therapy by modulating cortical excitability. METHODS/DESIGN: Two investigations are proposed: (1) an observational study with a convenience sample consisting of children with Down syndrome (group 1-cognitive age of 6 to 12 years according to the Wechsler Abbreviated Scale of Intelligence) and children with typical development 6 to 12 years of age (group 2). Both groups will undergo evaluations on a single day involving a three-dimensional analysis of upper limb movements, an analysis of muscle activity of the biceps and brachial triceps muscles and an analysis of visuospatial and cognitive-motor variables. (2) Analysis of clinical intervention: a pilot study and clinical trial will be conducted involving individuals with Down syndrome (cognitive age of 6 to 12 years according to the Wechsler Abbreviated Scale of Intelligence). The sample will be defined after conducting a pilot study with the same methodology as that to be used in the main study. The participants will be randomly allocated to two groups: An experimental group submitted to anodal tDCS combined with a VR game and a manual motor task and a control group submitted to sham tDCS combined with a VR game and a manual motor task. The training protocol will involve 10 sessions of active or sham tDCS during memory and motor task games. Three 20-min sessions will be held per week for a total of 10 sessions. Evaluations will be performed on three different occasions: pre-intervention, post-intervention (after 10 sessions) and follow-up (1 month after the intervention). Evaluations will consist of analyses of electroencephalographic signals, electromyographic signals of the biceps and triceps brachii, and the three-dimensional reconstruction of the reaching movement. The results will be analyzed statistically with the significance level set at 5% (p ≤ 0.05). DISCUSSION: The optimization of the results obtained with virtual reality training is believed to be related to the interactive experience with a wide range of activities and scenarios involving multiple sensory channels and the creation of exercises, the intensity of which can be adjusted to the needs of children. Therefore, the proposed study aims to complement the literature with further information on tDCS and VR training considering different variables to provide the scientific community with clinical data on this combination of interventions. TRIAL REGISTRATION: Brazilian Clinical Trials Registry (REBEC) protocol number RBR-43pk59 registered on 2019 March 27 https://ensaiosclinicos.gov.br/rg/RBR-43pk59 and Human Research Ethics Committee number 3.608.521 approved on 2019 September 30. Protocol version 2021 October 20. Any changes to the protocol will be reported to the committees and approved. Informed consent will be obtained from all participants by the clinical research coordinator and principal investigator.


Assuntos
Síndrome de Down , Estimulação Transcraniana por Corrente Contínua , Realidade Virtual , Encéfalo , Criança , Método Duplo-Cego , Síndrome de Down/diagnóstico , Síndrome de Down/terapia , Humanos , Estudos Observacionais como Assunto , Projetos Piloto , Ensaios Clínicos Controlados Aleatórios como Assunto , Extremidade Superior
18.
Comput Methods Biomech Biomed Engin ; 25(2): 140-147, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34121521

RESUMO

The effects of robotic-assisted gait training on upper and lower body strategy during gait in diplegic children with Cerebral Palsy (CP) were quantified using summary parameters (Upper Body Profile Score (UBPS) and Gait Profile Score (GPS)). Firstly, the upper body strategy during gait was assessed in 73 children with CP and 15 healthy children (Control Group: CG): patients with CP exhibited higher values of most of the summary parameters of the upper body position than the CG. Then, the effects of a robotic-assisted gait training in a sub-group of 35 children by means of UBPS were evaluated. After robotic-assisted gait training program, no significant differences as for the summary parameters (UBPS and GPS). However, considering the specific variables scores, significant improvements are displayed as for the upper body parameter on the sagittal plane (Upper Body Ant/Pst index) and the lower limbs, in particular pelvis (Pelvic Ant/Pst and Pelvic Int/Ext indices) and as for walking velocity. A sort of reorganization of full-body kinematics, especially at upper body and proximal level (pelvis) seems to appear, with a new gait approach, characterised by a better strategy of the upper body associated with a significant improvement of the pelvis movement.


Assuntos
Paralisia Cerebral , Procedimentos Cirúrgicos Robóticos , Fenômenos Biomecânicos , Criança , Terapia por Exercício , Marcha , Humanos , Caminhada
19.
Brain Sci ; 13(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36671993

RESUMO

The present study assessed the effects of anodal transcranial direct current stimulation (tDCS) combined with treadmill training on spatiotemporal and kinematic variables in stroke survivors using gait speed as the primary outcome. A randomized, sham-controlled, triple-blind, study was conducted involving 28 patients with hemiparesis allocated to two groups. The experimental group was submitted to treadmill training combined with anodal tDCS over the primary motor cortex (M1) of the damaged hemisphere. The control group was submitted to treadmill training combined with sham tDCS. Stimulation was administered (2 mA, 20 min) five times a week for two weeks during treadmill training. No significant differences (p > 0.05) in spatiotemporal variables were found in the intra-group and inter-group analyses. However, the experimental group demonstrated improvements in kinematic variables of the knee and ankle (p < 0.05) and these results were maintained one month after the end of the intervention. The inter-group analysis revealed significant differences (p < 0.05) with regard to the pelvis, hip and knee. Anodal tDCS over M1 of the damaged hemisphere combined with treadmill training did not affect spatiotemporal variables, but promoted improvements in kinematic variables of the pelvis, hip, knee and ankle and results were maintained one month after treatment.

20.
J Clin Med ; 10(23)2021 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-34884325

RESUMO

The relationship between skeletal muscle mass at the beginning of the post-acute rehabilitation phase and rehabilitation outcomes has been scarcely investigated. The aim of this study was to investigate the impact of the existence of sarcopenia upon admission to a post-acute COVID-19 patient rehabilitation unit on body composition and functional and respiratory capacity at discharge. Thirty-four post-acute COVID-19 patients were referred to our Rehabilitation Unit from different COVID Hospitals in northern Italy. Body weight loss, body composition, handgrip strength, functional parameters, oxygen saturation and related perception of dyspnea in several positions were measured before and after a 28-day multidisciplinary rehabilitation program. Spirometry was performed only upon admission. The intervention included psychiatric support, cognitive behavioral therapy, nutritional therapy and physiotherapy, including aerobic and resistance training. Training volume was 45 min/session, 6 sessions/week. Upon admission, the prevalence of sarcopenia among our patients was 58%. In all of the 34 patients, we observed a trend of improvement in all of the respiratory, body composition, muscle strength and functional parameters considered. Monitoring muscle mass and strength in post-acute COVID-19 patients appears to be a key predictor of rehabilitation outcomes. Early diagnosis of sarcopenia therefore appears to be of paramount importance in the management of post-acute COVID-19 patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...