1.
J Pers Med ; 14(4)2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38673043

RESUMO

PURPOSE: Errors and incidents may occur at any point within radiotherapy (RT). The aim of the present retrospective analysis is to evaluate the impact of a customized ARIA Visual Care Path (VCP) on quality assurance (QA) for the RT process. MATERIALS AND METHODS: The ARIA VCP was implemented in June 2019. The following tasks were customized and independently verified (by independent checks from radiation oncologists, medical physics, and radiation therapists): simulation, treatment planning, treatment start verification, and treatment completion. A retrospective analysis of 105 random and unselected patients was performed, and 945 tasks were reviewed. Patients' reports were categorized based on treatment years period: 2019-2020 (A); 2021 (B); and 2022-2023 (C). The QA metrics included data for timeliness of task completion and data for minor and major incidents. The major incidents were defined as incorrect prescriptions of RT dose, the use of different immobilization systems during RT compared to the simulation, the absence of surface-guided RT data for patients' positioning, incorrect dosimetric QA for treatment plans, and failure to complete RT as originally planned. A sample size of approximately 100 was able to obtain an upper limit of 95% confidence interval below 5-10% in the case of zero or one major incident. RESULTS: From June 2019 to December 2023, 5300 patients were treated in our RT department, an average of 1300 patients per year. For the purpose of this analysis, one hundred and five patients were chosen for the study and were subsequently evaluated. All RT staff achieved a 100% compliance rate in the ARIA VCP timely completion. A total of 36 patients were treated in Period A, 34 in Period B, and 35 in Period C. No major incidents were identified, demonstrating a major incident rate of 0.0% (95% CI 0.0-3.5%). A total of 26 out of 945 analyzed tasks (3.8%) were reported as minor incidents: absence of positioning photo in 32 cases, lack of patients' photo, and absence of plan documents in 4 cases. When comparing periods, incidents were statistically less frequent in Period C. CONCLUSIONS: Although the present analysis has some limitations, its outcomes demonstrated that software for the RT workflow, which is fully integrated with both the record-and-verify and treatment planning systems, can effectively manage the patient's care path. Implementing the ARIA VCP improved the efficiency of the RT care path workflow, reducing the risk of major and minor incidents.

2.
Radiol Med ; 128(4): 501-508, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36952115

RESUMO

PURPOSE: Aim of this study is to evaluate safety and efficacy of SBRT in elderly patients affected by localized prostate cancer (PC). MATERIAL AND METHODS: Men aged 70 years or older were enrolled and analyzed. The SBRT schedule was 35 Gy in 5 fractions administered in 1-2 weeks. According to risk group, androgen deprivation therapy (ADT) was prescribed. Urinary symptoms were evaluated at baseline using the International Prostate Symptom Score (IPSS). Genitourinary (GU) and gastrointestinal (GI) toxicities were assessed at the end of treatment, 2 weeks after SBRT and during follow-up using the Common Terminology Criteria for Adverse Events (CTCAE). PSA values were recorded before treatment and during follow-up as biochemical response criteria. RESULTS: Between 07/2019 and 09/2021, 111 patients were enrolled. Median age was 77 years. At the end of treatment, no acute GU/GI toxicities ≥ G2 were observed. At 2-3 weeks after treatment, 3 patients reported G2 GU toxicity, while 14 patients referred G2 GI toxicity. During the last follow up, 26 and 2 patients reported, respectively, G1 and G2 GU toxicity, while 22 and 1 cases described, respectively, G1 and G2 GI toxicity. No late toxicities ≥ G3 were recorded. GU toxicity is related to absence of urethra sparing, increasing PTV volume, Dmax PTV and IPSS; GI toxicity is related to RT schedule (each other day is better than consecutive day), Dmax rectum and IPSS, At a median follow-up of 24 months, excellent biochemical disease control was achieved in all cases with median PSA of 0.5 ng/ml. CONCLUSION: SBRT in elderly patients affected by PC is feasible and well tolerated with excellent biochemical disease control. Longer follow-up is needed to assess late toxicity profile and long-term clinical outcome.


Assuntos
Gastroenteropatias , Neoplasias da Próstata , Radiocirurgia , Masculino , Idoso , Humanos , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Antígeno Prostático Específico , Antagonistas de Androgênios , Radiocirurgia/efeitos adversos , Hipofracionamento da Dose de Radiação , Gastroenteropatias/etiologia
3.
J Pers Med ; 11(12)2021 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-34945823

RESUMO

AIM: To test inter-fraction reproducibility, intrafraction stability, technician aspects, and patient/physician's comfort of a dedicated immobilization solution for Brain Linac-based radiation therapy (RT). METHODS: A pitch-enabled head positioner with an open-face mask were used and, to evaluate inter- and intrafraction variations, 1-3 Cone-Beam Computed Tomography (CBCT) were performed. Surface Guided Radiation Therapy (SGRT) was used to evaluate intrafraction variations at 3 time points: initial (i), final (f), and monitoring (m) (before, end, and during RT). Data regarding technician mask aspect were collected. RESULTS: Between October 2019 and April 2020, 69 patients with brain disease were treated: 45 received stereotactic RT and 24 conventional RT; 556 treatment sessions and 863 CBCT's were performed. Inter-fraction CBCT mean values were longitudinally 0.9 mm, laterally 0.8 mm, vertically 1.1 mm, roll 0.58°, pitch 0.59°, yaw 0.67°. Intrafraction CBCT mean values were longitudinally 0.3 mm, laterally 0.3 mm, vertically 0.4 mm, roll 0.22°, pitch 0.33°, yaw 0.24°. SGRT intrafraction mean values were: i_, m_, f_ longitudinally 0.09 mm, 0.45 mm, 0.31 mm; i_, m_, f_ laterally 0.07 mm, 0.36 mm, 0.20 mm; i_, m_, f_ vertically 0.06 mm, 0.31 mm, 0.22 mm; i_, m_, f_ roll 0.025°, 0.208°, 0.118°; i_, m_, f_ pitch 0.036°, 0.307°, 0.194°; i_, m_, f_ yaw 0.039°, 0.274°, 0.189°. CONCLUSIONS: This immobilization solution is reproducible and stable. Combining CBCT and SGRT data confirm that 1 mm CTV-PTV margin for Linac-based SRT was adequate. Using open-face mask and SGRT, for conventional RT, radiological imaging could be omitted.