J Clin Med ; 13(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38592020

RESUMO

BACKGROUND: Esophagogastroduodenoscopy (EGD) is an endoscopic examination of the upper gastrointestinal tract that requires insufflation with gas, leading to intra-abdominal hypertension (IAH). There is evidence suggesting that IAH positively correlates with intracranial pressure (ICP) and possibly with intraocular pressure (IOP). The aim of this study was to examine the effect of a routine screening EGD on the IOP. METHODS: In this observational study, 25 patients were recruited; 15 males with a mean age of 50 ± 18 years and 10 females with a mean age of 45 ± 14 years. EGD was conducted under sedation in 21 subjects. Both eyes' IOP measurements were performed using Tonopen Avia in the sitting and left lateral decubitus positions before sedation and the start of EGD, and subsequently in the left lateral decubitus position when the endoscope reached the duodenum (D2) and at the end of the procedure. The final measurement was performed in the sitting position 10 min after the end of the procedure. RESULTS: The mean IOP in the sitting position was 15.16 ± 2.27 mmHg, and in the left lateral decubitus position, 15.68 ± 2.82 mmHg. When the gastroscope entered the D2, it was 21.84 ± 6.55 mmHg, at the end of the procedure, 15.80 ± 3.25 mmHg, and 10 min later, 13.12 ± 3.63 mmHg. There was a statistically significant IOP increase when the gastroscope entered the duodenum (p < 0.01). At the end of the gastroscopy, the IOP significantly decreased compared to the one registered when the gastroscope entered the D2 (p < 0.001) and it became similar to the values measured before the EGD, in the same left lateral decubitus position (p > 0.05). CONCLUSION: Significant changes in IOP were observed during the EGD. IOP fluctuations during EGD should be taken into account, especially in patients that need repeated EGDs during their life or in patients with glaucoma. Further studies are needed to better understand the short-effect and long-effect influence of an IOP increase in these patients.

3.
J Clin Med ; 12(19)2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37834998

RESUMO

The purpose of this study is to evaluate choroidal thickness (ChT) at the subfoveal and peripheral level after the instillation of 0.5% tropicamide + 10% phenylephrine 9 hydrochloride eye drops by using OCT scans in enhanced depth image (EDI) mode. In total, 53 patients (30 males and 23 females) were involved, and the mean age was 25.62 ± 2.41 (age range: 23-36). The dominant eye was treated with tropicamide + phenylephrine (Visumidriatic Fenil 100 mg/mL + 5 mg/mL, Visufarma) while the nondominant eye was used as the control. An OCT analysis was performed on both eyes before and 30 min after the instillation of a drop of mydriatic in the dominant eye. The ChT was measured by using the OCT software measurement tool (Spectralis; Heidelberg Engineering; Heidelberg, Germany, version 6.0). The results showed a statistically significant ChT decrease (p = 0.009) in the temporal sector after the treatment with tropicamide + phenylephrine. In the subfoveal and nasal sectors, no statistically significant ChT changes were detected (p = 0.94; p = 0.85) following the administration of the mydriatic eye drops. The ChT thinning in the temporal sector following the instillation of the tropicamide + phenylephrine eye drops suggests that in the case of ChT studies, mydriatic administration should be avoided.

6.
J Clin Med ; 12(18)2023 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-37762825

RESUMO

BACKGROUND: Comparing intraocular pressure (IOP) changes (ΔIOP) between obese subjects and non-obese controls in relation to different positions: standing, sitting, supine. METHODS: the IOP was measured in both obese patients and non-obese controls groups with Tono-Pen AVIA in different positions following this sequence: after 5 min (5') in the standing position, sitting, supine, supine after 5 min (supine 5') and immediately after standing. ΔIOP values obtained comparing all positions were, therefore, evaluated. RESULTS: 92 eyes of 46 obese subjects aged between 18 and 59 years (mean 38.07 ± 11.51 years) and of a Body Mass Index (BMI) between 31.84 and 60.65 (mean 41.84 ± 7.05) were evaluated. A total of 48 eyes of 24 non-obese controls aged between 23 and 55 (mean 35.21 ± 11.96 years) and of a BMI between 18.20 and 26.79 (mean 21.04 ± 2.36) were also recruited. In obese subjects, there were statistically significant differences between the IOP in the supine position and the supine positions 5' with all other IOP measurements (p < 0.05). There were statistically significant differences between ΔIOP in both supine positions and prolonged standing positions obtained by obese subjects and non-obese controls (p < 0.05). CONCLUSIONS: In obese subjects, there is a statistically significant increase in IOP in the supine positions that is significantly greater than the non-obese population. BMI is weakly correlated with IOP and ΔIOP in postural changes.

9.
J Clin Med ; 12(8)2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-37109228

RESUMO

This retrospective comparative study proposes a multi-formula approach by comparing no-history IOL power calculation methods after myopic laser-refractive-surgery (LRS). One-hundred-thirty-two eyes of 132 patients who had myopic-LRS and cataract surgery were examined. ALMA, Barrett True-K (TK), Ferrara, Jin, Kim, Latkany and Shammas methods were evaluated in order to back-calculate refractive prediction error (PE). To eliminate any systematic error, constant optimization through zeroing-out the mean error (ME) was performed for each formula. Median absolute error (MedAE) and percentage of eyes within ±0.50 and ±1.00 diopters (D) of PE were analyzed. PEs were plotted with corresponding mean keratometry (K), axial length (AL), and AL/K ratio; then, different ranges were evaluated. With optimized constants through zeroing-out ME (90 eyes), ALMA was better when K ≤ 38.00 D-AL > 28.00 mm and when 38.00 D < K ≤ 40.00 D-26.50 mm < AL ≤ 29.50 mm; Barrett-TK was better when K ≤ 38.00 D-AL ≤ 26.50 mm and when K > 40.00 D-AL ≤ 28.00 mm or AL > 29.50 mm; and both ALMA and Barrett-TK were better in other ranges. (p < 0.05) Without modified constants (132 eyes), ALMA was better when K > 38.00 D-AL ≤ 29.50 mm and when 36.00 < K ≤ 38.00 D-AL ≤ 26.50 mm; Barrett-TK was better when K ≤ 36.00 D and when K ≤ 38.00 D with AL > 29.50 mm; and both ALMA and Barrett-TK were better in other ranges (p < 0.05). A multi-formula approach, according to different ranges of K and AL, could improve refractive outcomes in post-myopic-LRS eyes.

10.
11.
Microorganisms ; 11(2)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36838468

RESUMO

Due to the wide etiology of conjunctivitis, the expensive and time-consuming diagnosis requires new therapeutic strategies with broad-spectrum antimicrobial activity and nonselective mechanisms of action. In this context, eye drops could provide an alternative to conventional antimicrobial therapies. Here, we compare the antibacterial and antiviral activity of Oftasecur and Visuprime, commercially available ophthalmic solutions. Cytotoxicity assay was performed on Vero CCL-81 cells by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide (MTT) test. Antibacterial efficacy was evaluated on Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Escherichia coli, and Klebsiella pneumoniae by disk diffusion, broth microdilution methods, and time-killing tests. Furthermore, the antiviral activity against HSV-1 was estimated by co-treatment, cell and viral pretreatment and post-treatment, via plaque reduction assay, fluorescence assessment (GFP-engineered HSV-1), and real-time PCR. After 24 h of exposure, Oftasecur and Visuprime showed a volume-inducing 50% of cytotoxicity of 125 and 15.8 µL, respectively Oftasecur and Visuprime induced 90% antibacterial activity in response to mean volume of 10.0 and 4.4 µL for Gram-positive and Gram-negative strains, respectively. Oftasecur exerted bactericidal action on both bacterial populations, while Visuprime was bacteriostatic on Gram-negative strains and slightly bactericidal on Gram-positive bacteria. A major impact on infectivity occurred by exposure of viral particles to the ophthalmic solutions. In detail, 50% of inhibition was verified by exposing the viral particles to 3.12 and 0.84 µL of Oftasecur and Visuprime, respectively, for 1 h. The reduction of the fluorescence and the expression of the viral genes confirmed the recorded antiviral activity. Due to their high antimicrobial efficiency, Oftasecur and Visuprime could represent a valid empirical strategy for the treatment of conjunctivitis.

13.
Sci Rep ; 12(1): 18845, 2022 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-36344612

RESUMO

To verify the influence of axial length (AL) variations after cataract surgery in IOL power calculation. Patients underwent ophthalmic evaluation before surgery, including optical biometry with IOLMaster 500. Same exams were repeated 2 months after surgery: AL of operated eye was evaluated using two modes (pseudophakic/aphakic options). Mean Keratometry and AL changes were analyzed. Furthermore, refractive prediction error (PE) was back-calculated with Barrett Universal-II, Hoffer-Q, Holladay-1 and SRK/T formulas. To eliminate any systematic error, the mean error (ME) was zeroed-out for each formula. MEs and median absolute errors (MedAEs) of PEs were analyzed. Two-hundred-one operated eyes of 201 patients and 201 opposite eyes were evaluated. In operated eyes, mean AL difference was - 0.11 ± 0.07 mm (p < 0.001) with pseudophakic option and 0.00 ± 0.07 mm (p = 0.922) with aphakic option. There were not-statistically significant differences between MedAE of PEs calculated after zeroing-out the ME with different ALs (p > 0.05). Instead, only MEs of PEs obtained with postoperative ALs-pseudophakic option were not-statistically different from zero (p > 0.05). AL measurement change after cataract surgery is probably due to a systematic error in optical biometer in case of phakic eyes. A correction factor applied to preoperative AL could eliminate any systematic error in IOL power calculation without modifying the lens constant.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Erros de Refração , Humanos , Refração Ocular , Comprimento Axial do Olho , Reprodutibilidade dos Testes , Biometria , Estudos Retrospectivos , Óptica e Fotônica
14.
Sci Rep ; 12(1): 20190, 2022 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-36418360

RESUMO

In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ophthalmologic exam. IOP was measured in each eye with DCT and then with GAT. IOP values obtained with GAT were corrected with 10 equations and then compared with those provided by DCT. Participants mean age was 42.24 ± 14.08 years; mean IOP measured with DCT was 17.61 ± 2.87 and 15.50 ± 2.47 mmHg, measured with GAT. The mean discordance between DCT and GAT measurements was 2.11 ± 2.24 mmHg. All the correcting formulas, but Srodka one (p ˂ 0.001), tend to increase the difference between GAT and DCT. According to these results Sródka equation provides the best correction, reducing the difference between the two IOP measurement methods of - 0.03 ± 0.85 mmHg. Other equations do not provide a valid improvement of the agreement between the two methods or they provide a worsening of the agreement.


Assuntos
Pressão Intraocular , Tonometria Ocular , Humanos , Adulto , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tonometria Ocular/métodos , Olho , Manometria
15.
J Clin Med ; 11(21)2022 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-36362460

RESUMO

Background: Intraocular pressure (IOP) is influenced by body position. The purpose of this study is to compare the IOP measurements obtained with two different devices, to investigate IOP changes in standing, sitting, and supine positions. Methods: In this comparative prospective case series, IOP was measured in sitting, supine, prone, and standing (standing 1) positions and again five minutes after standing (standing 2), utilizing an Icare Pro (ICP) and a Tono-Pen Avia (TPA) in the 64 eyes of 32 healthy subjects. Results: Compared to the sitting position, both devices showed an increase in the IOP both in supine and standing 2 positions (p < 0.05). The mean IOP difference between the two devices was: in the sitting position, 0.57 ± 2.10 mmHg (range: −3.80 to 6.60 mmHg) (p < 0.05), in the supine position, 0.93 ± 2.49 mmHg (range: −4.50 to 7.10 mmHg) (p < 0.05), in the standing 1 position, 0.37 ± 1.96 mmHg (range: −5.20 to 5.00 mmHg) (p = 0.102), and in the standing 2 position 0.73 ± 2.03 mmHg (range: −4.5 to 6.4 mmHg) (p < 0.001). Conclusions: The results highlight an agreement between the TPA and ICP, both confirming not only the increase in IOP in the supine position, but also showing an increase in the standing 2 position. Therefore, it is suggested to perform such measurements in patients with glaucoma, to explain its progression in an apparently normal tension or in compensated patients.

16.
J Clin Med ; 11(20)2022 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-36294473

RESUMO

Background: To evaluate the interocular optic nerve diameter (ONDs) asymmetry in patients with idiopathic intracranial hypertension (IIH) utilizing the A-scan ultrasound technique. Methods: Thirty-seven patients diagnosed with IIH were recruited from outpatients referred to the University Eye Unit between June 2014 and December 2021. Patients with optic disc pseudoedema or edema caused by other conditions were excluded. All patients with negative neuroimaging for intracranial space-occupying masses underwent standardized A-scan measurement of the OND in the primary gaze and lateral position (30 degrees test). Results: Mean, median, standard deviation, the minimum and maximum value of the two eyes at 0 degrees and the difference between the left and right thicker and thinner ONDs were measured. The two-tailed paired student t-test between the two eyes was performed using SPSS software. A statistically significant difference (p-value <0.001) between the two eyes, without a side prevalence, was found. Conclusions: Due to the differences between the ONDs of both eyes, we propose to use the mean of the ONDs between the left and right eyes at 0 degrees with the standardized A-scan diagnostic technique for a better follow-up of patients with IIH.

19.
J Clin Med ; 11(13)2022 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-35806999

RESUMO

This observational study compared optic coherence tomography (OCT) and B-scan in the detection of optic disc drusen. In total, 86 eyes of 50 patients with optic disc drusen (ODD) (36 bilateral) with a mean age of 34.68 ± 23.81 years, and 54 eyes of 27 patients with papilledema, with a mean age of 35.42 years ± 17.47, were examined. Patients with ODD, diagnosed with ultrasound, underwent spectral-domain OCT evaluation. With US, 28 ODD cases were classified as large (4 buried and 24 superficial), 58 were classified as point-like (6 buried, 49 superficial and 3 mixed). Then, all patients underwent OCT. OCT was able to detect the presence of ODD and/or peripapillary hyperreflective ovoid mass structure (PHOMS) in 69 eyes (p < 0.001). In particular, 7 eyes (8.14%) showed the presence of ODD alone, 25 eyes (29.07%) showed only PHOMS and 37 eyes (43.02%) showed ODD and PHOMS. In 17 eyes (19.77%) no ODD or PHOMS were detected. In the papilledema group, no ODD were observed with both US and OCT. OCT showed the presence of drusen or similar lesions in only 80.23% of the cases highlighted by the US scan, so it does not allow for certain ODD diagnoses, especially in the case of buried ODD.