Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
3.
Clin Infect Dis ; 71(5): 1331-1333, 2020 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-31811283

RESUMO

We describe a sudden 2-week outbreak due to a blaNDM-1Citrobacter amalonaticus strain in a 22-bed digestive rehabilitation center. Three of the 5 colonized patients received long-term rifaximin treatment to prevent hepatic encephalopathy. The strains were genotypically identical, phenotypically resistant to rifampin, and harbored arr-3, a rifampin adenosine diphosphate-ribosyl transferase.


Assuntos
Antibacterianos , Rifampina , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Surtos de Doenças , Humanos , Testes de Sensibilidade Microbiana , Centros de Reabilitação , Rifampina/farmacologia , Rifaximina
4.
Infect Control Hosp Epidemiol ; 35(12): 1539-42, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25419778

RESUMO

Contamination of a point-of-care ultrasound system (POCUS) mainly involved electrocardiography accessories and included pathogenic microorganisms. The use of a glass-sealed control panel significantly facilitated its cleaning and reduced its bacterial contamination compared with a standard control panel. Overall hand hygiene compliance during examinations with POCUS was poor.


Assuntos
Infecção Hospitalar/prevenção & controle , Eletrocardiografia/instrumentação , Contaminação de Equipamentos/prevenção & controle , Bactérias/classificação , Bactérias/isolamento & purificação , Transmissão de Doença Infecciosa/prevenção & controle , Higiene das Mãos/normas , Humanos , Controle de Infecções/métodos , Controle de Infecções/normas , Sistemas Automatizados de Assistência Junto ao Leito
5.
Infect Control Hosp Epidemiol ; 34(2): 119-24, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23295556

RESUMO

OBJECTIVE: To describe the course and management of a protracted outbreak after intercontinental transfer of 2 patients colonized with multidrug-resistant Acinetobacter baumannii (MDRAB). DESIGN: An 18-month outbreak investigation. SETTING: An 860-bed university hospital in France. PATIENTS: Case patients (ie, carriers) were those colonized or infected with an MDRAB isolate. METHODS: During the epidemic period, all intensive care unit (ICU) patients and contacts of carriers who were transferred to wards were screened for MDRAB carriage. Contact precautions, environmental screening, and auditing of healthcare worker (HCW) practices were implemented; rooms were cleaned with hydrogen peroxide mist disinfection. One ICU, in which most of the cases occurred, was closed on 4 occasions for thorough cleaning and disinfection. RESULTS: The 2 index case patients were identified as 2 patients who carried the same MDRAB strain and who were admitted to the hospital after repatriation from Tahiti 5 months apart. During an 18-month period, a total of 84 secondary cases occurred. Reintroduction of MDRAB into the ICUs occurred from patients previously colonized or from healthcare personnel. Termination of the outbreak was only achieved when all carriers from wards or the ICU were cohorted to an isolation unit with dedicated healthcare personnel. CONCLUSIONS: Intercontinental transfer of carriers of MDRAB can result in extensive outbreaks and serious disruption of the hospital's organization. Transmission from carriers most likely occurred via the hands of HCWs, poor cleaning protocols, airborne spread, and contaminated water from sink traps. This protracted outbreak was controlled only after implementation of an extensive control program and eventual cohorting of all carriers in an isolation unit with dedicated healthcare personnel.


Assuntos
Infecções por Acinetobacter/epidemiologia , Acinetobacter baumannii/efeitos dos fármacos , Infecção Hospitalar/epidemiologia , Surtos de Doenças , Farmacorresistência Bacteriana Múltipla , Infecções por Acinetobacter/tratamento farmacológico , Infecções por Acinetobacter/transmissão , Acinetobacter baumannii/isolamento & purificação , Portador Sadio/microbiologia , Busca de Comunicante , Infecção Hospitalar/tratamento farmacológico , Infecção Hospitalar/transmissão , França/epidemiologia , Hospitais Universitários , Humanos , Incidência , Unidades de Terapia Intensiva , Internacionalidade , Transferência de Pacientes , Viagem
6.
Clin Infect Dis ; 47(5): 627-33, 2008 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-18662134

RESUMO

BACKGROUND: Nosocomial transmission is the second most frequent cause of hepatitis C virus (HCV) infection. A prospective observational study was conducted to assess the roles of environmental contamination and noncompliance with standard precautions in HCV cross-transmission in a hemodialysis unit. METHODS: Patients undergoing chronic hemodialysis in a French university hospital unit were systematically screened, revealing 2 sporadic cases of HCV transmission. An investigation was launched to determine whether the patients were infected in the hemodialysis unit and the possible roles of environmental contamination and noncompliance with standard precautions. We examined possible relationships among new cases of HCV infection, environmental contamination by blood and HCV RNA, and compliance with guidelines on hand hygiene and glove use. RESULTS: Two patients experienced seroconversion to HCV during the study period. Phylogenetic analyses showed that 1 of these patients was infected with the same strain as that affecting a chronically infected patient also treated in the unit. Of 740 environmental surface samples, 82 (11%) contained hemoglobin; 6 (7%) of those contained HCV RNA. The rate of compliance with hand hygiene was 37% (95% confidence interval, 35%-39%), and gloves were immediately removed after patient care in 33% (95% confidence interval, 29%-37%) of cases. A low ratio of nurses to patients and poor hand hygiene were independent predictors of the presence of hemoglobin on environmental surfaces. CONCLUSION: Blood-contaminated surfaces may be a source of HCV cross-transmission in a hemodialysis unit. Strict compliance with hand hygiene and glove use and strict organization of care procedures are needed to reduce the risk of HCV cross-transmission among patients undergoing hemodialysis.


Assuntos
Infecção Hospitalar/epidemiologia , Microbiologia Ambiental , Fidelidade a Diretrizes , Unidades Hospitalares de Hemodiálise , Hepacivirus/isolamento & purificação , Hepatite C/epidemiologia , Infecção Hospitalar/transmissão , França/epidemiologia , Genótipo , Luvas Protetoras/estatística & dados numéricos , Desinfecção das Mãos , Hepacivirus/classificação , Hepacivirus/genética , Hepatite C/transmissão , Hospitais Universitários , Humanos , Filogenia , Estudos Prospectivos , RNA Viral/genética
7.
Intensive Care Med ; 31(12): 1715-8, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16228175

RESUMO

OBJECTIVE: To compare bacterial contamination associated with electronic faucets and manual faucets in wards admitting patients highly susceptible to infection. DESIGN: Water samples from electronic faucets and manual faucets were taken according to the French recommendations on water surveillance in healthcare settings. SETTING: Hematology and intensive care units (ICUs) of a 900-bed university hospital and a 500-bed general hospital. MEASUREMENTS AND RESULTS: Overall 227 water samples were collected, 92 from electronic faucets and 135 from manual faucets. Thirty-six (39%) of the water samples from electronic faucets and 2 (1%) from manual faucets yielded pathogenic bacteria. In hematology wards 17 (30%) samples from electronic faucets and 2 (2%) from manual faucets were contaminated. In ICUs 19 (53%) samples from electronic faucets and none of 48 from manual faucets were contaminated. All samples were contaminated with various strains of Pseudomonas aeruginosa (8 to >100 CFU/100 ml). Despite hyperchlorination the electronic faucets remained contaminated. Replacing the contaminated electronic faucets by manual faucets led to a complete and sustained elimination of bacterial contamination. Contamination was not associated with a particular brand of electronic faucets. CONCLUSIONS: Our findings demonstrate that electronic faucets are significantly more frequently contaminated than manual faucets and could be a major reservoir for P. aeruginosa. Wards admitting patients highly susceptible to infection and using electronic faucets should be aware of this potential threat. Moreover, units already equipped with these devices, should check water quality periodically.


Assuntos
Contaminação de Equipamentos/prevenção & controle , Desinfecção das Mãos , Banheiros , Microbiologia da Água , Contagem de Colônia Microbiana , Eletrônica , Hematologia , Unidades Hospitalares , Humanos , Unidades de Terapia Intensiva , Infecções por Pseudomonas/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA