Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Phys Med ; 87: 131-135, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34153572

RESUMO

Occupational radiation doses from interventional procedures have the potential to be relatively high. The requirement to optimise these doses encourages the use of electronic or active personal dosimeters (APDs) which are now increasingly used in hospitals. They are typically used in tandem with a routine passive dosimetry monitoring programme, with APDs used for real-time readings, for training purposes and when new imaging technology is introduced. However, there are limitations when using APDs. A survey in hospitals to identify issues related to the use of APDs was recently completed, along with an extensive series of APD tests by the EURADOS Working Group 12 on Dosimetry for Medical Imaging. The aim of this review paper is to summarise the state of the art regarding the use of APDs. We also used the results of our survey and our tests to develop a set of recommendations for the use of APDs in the clinical interventional radiology/cardiology settings, and draw attention to some of the current challenges.


Assuntos
Exposição Ocupacional , Monitoramento de Radiação , Proteção Radiológica , Hospitais , Exposição Ocupacional/análise , Doses de Radiação , Radiologia Intervencionista , Local de Trabalho
2.
Radiat Prot Dosimetry ; 194(1): 42-56, 2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-33989429

RESUMO

Since 2012, the European Radiation Dosimetry Group (EURADOS) has developed its Strategic Research Agenda (SRA), which contributes to the identification of future research needs in radiation dosimetry in Europe. Continued scientific developments in this field necessitate regular updates and, consequently, this paper summarises the latest revision of the SRA, with input regarding the state of the art and vision for the future contributed by EURADOS Working Groups and through a stakeholder workshop. Five visions define key issues in dosimetry research that are considered important over at least the next decade. They include scientific objectives and developments in (i) updated fundamental dose concepts and quantities, (ii) improved radiation risk estimates deduced from epidemiological cohorts, (iii) efficient dose assessment for radiological emergencies, (iv) integrated personalised dosimetry in medical applications and (v) improved radiation protection of workers and the public. This SRA will be used as a guideline for future activities of EURADOS Working Groups but can also be used as guidance for research in radiation dosimetry by the wider community. It will also be used as input for a general European research roadmap for radiation protection, following similar previous contributions to the European Joint Programme for the Integration of Radiation Protection Research, under the Horizon 2020 programme (CONCERT). The full version of the SRA is available as a EURADOS report (www.eurados.org).


Assuntos
Monitoramento de Radiação , Proteção Radiológica , Europa (Continente) , Humanos , Doses de Radiação , Radiação Ionizante , Radiometria
3.
Radiat Prot Dosimetry ; 188(1): 22-29, 2020 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-31832653

RESUMO

Medical staff in interventional procedures are among the professionals with the highest occupational doses. Active personal dosemeters (APDs) can help in optimizing the exposure during interventional procedures. However, there can be problems when using APDs during interventional procedures, due to the specific energy and angular distribution of the radiation field and because of the pulsed nature of the radiation. Many parameters like the type of interventional procedure, personal habits and working techniques, protection tools used and X-ray field characteristics influence the occupational exposure and the scattered radiation around the patient. In this paper, we compare the results from three types of APDs with a passive personal dosimetry system while being used in real clinical environment by the interventional staff. The results show that there is a large spread in the ratios of the passive and active devices.


Assuntos
Hospitais , Corpo Clínico , Exposição Ocupacional/análise , Dosímetros de Radiação , Radiologia Intervencionista , Humanos , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Local de Trabalho
4.
J Radiol Prot ; 39(4): R37-R50, 2019 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-31307030

RESUMO

This paper provides a summary of the Education and Training (E&T) activities that have been developed and organised by the European Radiation Dosimetry Group (EURADOS) in recent years and in the case of Training Courses over the last decade. These E&T actions include short duration Training Courses on well-established topics organised within the activity of EURADOS Working Groups (WGs), or one-day events integrated in the EURADOS Annual Meeting (workshops, winter schools, the intercomparison participants' sessions and the learning network, among others). Moreover, EURADOS has recently established a Young Scientist Grant and a Young Scientist Award. The Grant supports young scientists by encouraging them to perform research projects at other laboratories of the EURADOS network. The Award is given in recognition of excellent work developed within the WGs' work programme. Additionally, EURADOS supports the dissemination of knowledge in radiation dosimetry by promoting and endorsing conferences such as the individual monitoring (IM) series, the neutron and ion dosimetry symposia (NEUDOS) and contributions to E&T sessions at specific events.

5.
Radiat Prot Dosimetry ; 182(3): 317-322, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590842

RESUMO

In the context of a new annual eye lens dose limit for occupational exposure equal to 20 mSv, European Radiation Dosimetry Group (EURADOS) organized an intercomparison dedicated to eye lens dosemeters, including photon and beta radiations. The objective was to complete the first intercomparison recently organized by EURADOS for photons and to update the overview of eye lens dosemeters available in Europe. The dosemeters provided by the 22 participants coming from 12 countries were all composed of thermoluminescent detectors. The dosemeters were irradiated with photon and beta fields defined in relevant standards. The results, provided by participants in terms of Hp(3), were compared to the reference delivered doses. Results are globally satisfactory for photons since 90% of the data are in accordance to the ISO 14146 standard requirements. The respective values for betas stress the fact that dosemeters designed for Hp(0.07) are not suitable to monitor the eye lens dose in case of betas.


Assuntos
Cristalino/efeitos da radiação , Exposição Ocupacional/análise , Dosímetros de Radiação/normas , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Partículas beta , Calibragem , Europa (Continente) , Humanos , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos
6.
Phys Med ; 52: 154-164, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30139604

RESUMO

PURPOSE: This study aims at characterising the properties of TruView™ and ClearView™ two new gel dosimeters (Modus Medical Devices Inc.) and at studying the feasibility of relative dosimetry using these dosimeters and the Vista™ Optical CT scanner to accurately evaluate dose. METHODS: In this work, we investigated key dosimetric aspects (dose response, energy and dose rate dependence) and stability of these radiochromic gels initiated in preliminary works (Huet et al., 2017; Colnot et al., 2017) using spectrophotometric measurements. Moreover, by mean of optical CT scanning (Vista™), their performances to measure relative depth dose (PDD) and cross profiles were analysed. RESULTS: TruView™ and ClearView™ present a linear dose response up to 20 Gy and up to 80 Gy respectively, independent of both photon beam energy (4-18 MV) and dose rate (up to 9.9 Gy/min) (Huet et al., 2017; Colnot et al., 2017). ClearView™ response proves to be stable for a week post-irradiation and uniform within the batch whereas TruView™ presents an unstable but uniform response. Optical CT scanning generates errors due to stray light that need to be corrected in order to use these gels; ClearView™ scanning particularly requires important precautions. After corrections, those gels used in combination with the Vista™ scanner show promising spatial and dosimetric precision (dose difference <5%). Finally, TruView™ is reusable and presents excellent reproducible response (maximum 3% difference) and the ClearView™ dosimeter presents good spatial stability (0.5% difference after 6 days). CONCLUSION: This study provides important knowledge about two gel dosimeters presenting interesting dosimetric properties. A study is ongoing to benchmark those promising candidates for clinical dose verification.


Assuntos
Dosímetros de Radiação , Radiometria/instrumentação , Calibragem , Elétrons , Estudos de Viabilidade , Imagem Óptica/instrumentação , Imagem Óptica/métodos , Imagens de Fantasmas , Fótons , Espectrofotometria , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Incerteza
7.
Phys Med ; 32(9): 1111-7, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27554367

RESUMO

OBJECTIVE: This paper aims to provide some practical recommendations to reduce eye lens dose for workers exposed to X-rays in interventional cardiology and radiology and also to propose an eye lens correction factor when lead glasses are used. METHODS: Monte Carlo simulations are used to study the variation of eye lens exposure with operator position, height and body orientation with respect to the patient and the X-ray tube. The paper also looks into the efficiency of wraparound lead glasses using simulations. Computation results are compared with experimental measurements performed in Spanish hospitals using eye lens dosemeters as well as with data from available literature. RESULTS: Simulations showed that left eye exposure is generally higher than the right eye, when the operator stands on the right side of the patient. Operator height can induce a strong dose decrease by up to a factor of 2 for the left eye for 10-cm-taller operators. Body rotation of the operator away from the tube by 45°-60° reduces eye exposure by a factor of 2. The calculation-based correction factor of 0.3 for wraparound type lead glasses was found to agree reasonably well with experimental data. CONCLUSIONS: Simple precautions, such as the positioning of the image screen away from the X-ray source, lead to a significant reduction of the eye lens dose. Measurements and simulations performed in this work also show that a general eye lens correction factor of 0.5 can be used when lead glasses are worn regardless of operator position, height and body orientation.


Assuntos
Cardiologia/métodos , Cristalino/efeitos da radiação , Proteção Radiológica/métodos , Radiologia Intervencionista/métodos , Algoritmos , Simulação por Computador , Desenho de Equipamento , Humanos , Chumbo , Método de Monte Carlo , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Recursos Humanos , Raios X
8.
Phys Med ; 32(4): 590-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27050170

RESUMO

PURPOSE: In scattering proton therapy, the beam incidence, i.e. the patient's orientation with respect to the beam axis, can significantly influence stray neutron doses although it is almost not documented in the literature. METHODS: MCNPX calculations were carried out to estimate stray neutron doses to 25 healthy organs of a 10-year-old female phantom treated for an intracranial tumor. Two beam incidences were considered in this article, namely a superior (SUP) field and a right lateral (RLAT) field. For both fields, a parametric study was performed varying proton beam energy, modulation width, collimator aperture and thickness, compensator thickness and air gap size. RESULTS: Using a standard beam line configuration for a craniopharyngioma treatment, neutron absorbed doses per therapeutic dose of 63µGyGy(-1) and 149µGyGy(-1) were found at the heart for the SUP and the RLAT fields, respectively. This dose discrepancy was explained by the different patient's orientations leading to changes in the distance between organs and the final collimator where external neutrons are mainly produced. Moreover, investigations on neutron spectral fluence at the heart showed that the number of neutrons was 2.5times higher for the RLAT field compared against the SUP field. Finally, the influence of some irradiation parameters on neutron doses was found to be different according to the beam incidence. CONCLUSION: Beam incidence was thus found to induce large variations in stray neutron doses, proving that this parameter could be optimized to enhance the radiation protection of the patient.


Assuntos
Craniofaringioma/radioterapia , Nêutrons , Imagens de Fantasmas , Neoplasias Hipofisárias/radioterapia , Terapia com Prótons/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Criança , Feminino , Humanos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
9.
Radiat Prot Dosimetry ; 170(1-4): 21-6, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26163384

RESUMO

In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of the passive eye lens dosemeters currently in use in Europe for occupational monitoring in medical fields. A total of 20 European individual monitoring services from 15 different countries have participated. The dosemeters provided by the participants were all composed of thermoluminescent detectors, of various types and designs. The irradiations were carried out with several photon fields chosen to cover the energy and angle ranges encountered in medical workplace. Participants were asked to report the doses in terms of Hp(3) using their routine protocol. The results provided by each participant were compared with the reference delivered doses. All the results were anonymously analysed. Results are globally satisfactory since, among the 20 participants, 17 were able to provide 90 % of their response in accordance with the ISO 14146 standard requirements.


Assuntos
Cristalino/efeitos da radiação , Exposição Ocupacional/análise , Doses de Radiação , Dosímetros de Radiação , Monitoramento de Radiação/instrumentação , Proteção Radiológica/métodos , Calibragem , Europa (Continente) , União Europeia , Humanos , Fótons , Monitoramento de Radiação/métodos , Proteção Radiológica/instrumentação
10.
Radiat Prot Dosimetry ; 168(1): 11-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25737581

RESUMO

In 2011, the International Commission on Radiological Protection (ICRP) reviewed its recommendation concerning the equivalent dose limit for the eye lens, lowering it to 20 mSv in a year, for occupational exposure in planned exposure situations. The ICRP's statement does not contain any explicit recommendations regarding the organ dose limit for the eye lens for public exposure. For the moment, no change is proposed. But, to be coherent in the overall approach, the current equivalent limit for the public might be lowered. A similar yardstick than in the former recommendation may be used, that is to say a reduction of 10 times lower than that for occupational exposure. In this context, additional data on potential scenarios for public exposure of the eye lens are necessary. This paper, mainly based on a literature study, aims to provide, as far as possible, an exhaustive list of the situations in which members of the public can be exposed at the level of the eye lens. Once these situations have been defined, some calculations, made to assess the associated doses to the eye lens, are presented. This literature study did not reveal any current situations where members of the public would receive significant radiation doses to the eye lens. Indeed, the situations in which the dose to the eye lens might reach around 1 mSv per year for the public are extremely rare.


Assuntos
Exposição Ambiental/efeitos adversos , Cristalino/efeitos da radiação , Materiais de Construção , Materiais Dentários , Humanos , Cooperação Internacional , Joias , Lentes , Exposição Ocupacional , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Radiometria , Medição de Risco , Televisão , Trítio/análise , Armas
11.
Phys Med ; 31(8): 1112-1117, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26439858

RESUMO

PURPOSE: Point detectors are frequently used to measure patient's maximum skin dose (MSD) in fluoroscopically-guided interventional procedures (IP). However, their performance and ability to detect the actual MSD are rarely evaluated. The present study investigates the sampling uncertainty associated with the use of grids of point detectors to measure MSD in IP. METHOD: Chemoembolisation of the liver (CE), percutaneous coronary intervention (PCI) and neuroembolisation (NE) procedures were studied. Spatial dose distributions were measured with XR-RV3 Gafchromic(®) films for 176 procedures. These distributions were used to simulate measurements performed using grids of detectors such as thermoluminescence detectors, with detector spacing from 1.4 up to 10 cm. RESULTS: The sampling uncertainty was the highest in PCI and NE procedures. With 40 detectors covering the film area (36 cm × 44 cm), the maximum dose would be on average 86% and 63% of the MSD measured with Gafchromic(®) films in CE and PCI procedures, respectively. In NE procedures, with 27 detectors covering the film area (14 cm × 35 cm), the maximum dose measured would be on average 82% of the MSD obtained with the Gafchromic(®) films. CONCLUSION: Thermoluminescence detectors show good energy and dose response in clinical beam qualities. However the poor spatial resolution of such point-like dosimeters may far outweigh their good dosimetric properties. The uncertainty from the sampling procedure should be estimated when point detectors are used in IP because it may lead to strong underestimation of the MSD.


Assuntos
Quimioembolização Terapêutica/métodos , Intervenção Coronária Percutânea/métodos , Doses de Radiação , Pele/efeitos da radiação , Fluoroscopia , Dosimetria Termoluminescente , Incerteza
12.
Med Phys ; 42(7): 4211-26, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26133620

RESUMO

PURPOSE: To investigate the optimal use of XR-RV3 GafChromic(®) films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. METHODS: XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. RESULTS: First, the performance analysis of six different scanner models has shown that scan uniformity perpendicular to the lamp motion axis and that long term stability are the main sources of scanner-related uncertainties. These could induce errors of up to 7% on the film readings unless regularly checked and corrected. Typically, scan uniformity correction matrices and reading normalization to the scanner-specific and daily background reading should be done. In addition, the analysis on multiple film batches has shown that XR-RV3 films have generally good uniformity within one batch (<1.5%), require 24 h to stabilize after the irradiation and their response is roughly independent of dose rate (<5%). However, XR-RV3 films showed large variations (up to 15%) with radiation quality both in standard laboratory and in clinical conditions. As such, and prior to conducting patient skin dose measurements, it is mandatory to choose the appropriate calibration beam quality depending on the characteristics of the x-ray systems that will be used clinically. In addition, yellow side film irradiations should be preferentially used since they showed a lower dependence on beam parameters compared to white side film irradiations. Finally, among the six different fit equations tested in this work, typically used third order polynomials and more rational and simplistic equations, of the form dose inversely proportional to pixel value, were both found to provide satisfactory results. Fitting-related uncertainty was clearly identified as a major contributor to the overall film dosimetry uncertainty with up to 40% error on the dose estimate. CONCLUSIONS: The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.


Assuntos
Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Algoritmos , Calibragem , Doses de Radiação , Pele/efeitos da radiação , Incerteza , Raios X
13.
Phys Med ; 31(3): 248-56, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25682475

RESUMO

PURPOSE: This study focuses on the configuration and validation of an analytical model predicting leakage neutron doses in proton therapy. METHODS: Using Monte Carlo (MC) calculations, a facility-specific analytical model was built to reproduce out-of-field neutron doses while separately accounting for the contribution of intra-nuclear cascade, evaporation, epithermal and thermal neutrons. This model was first trained to reproduce in-water neutron absorbed doses and in-air neutron ambient dose equivalents, H*(10), calculated using MCNPX. Its capacity in predicting out-of-field doses at any position not involved in the training phase was also checked. The model was next expanded to enable a full 3D mapping of H*(10) inside the treatment room, tested in a clinically relevant configuration and finally consolidated with experimental measurements. RESULTS: Following the literature approach, the work first proved that it is possible to build a facility-specific analytical model that efficiently reproduces in-water neutron doses and in-air H*(10) values with a maximum difference less than 25%. In addition, the analytical model succeeded in predicting out-of-field neutron doses in the lateral and vertical direction. Testing the analytical model in clinical configurations proved the need to separate the contribution of internal and external neutrons. The impact of modulation width on stray neutrons was found to be easily adjustable while beam collimation remains a challenging issue. Finally, the model performance agreed with experimental measurements with satisfactory results considering measurement and simulation uncertainties. CONCLUSION: Analytical models represent a promising solution that substitutes for time-consuming MC calculations when assessing doses to healthy organs.


Assuntos
Modelos Teóricos , Método de Monte Carlo , Nêutrons , Terapia com Prótons , Espalhamento de Radiação , Humanos , Dosagem Radioterapêutica
14.
Radiat Prot Dosimetry ; 164(1-2): 138-42, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25316909

RESUMO

To help operators acknowledge patient dose during interventional procedures, EURADOS WG-12 focused on measuring patient skin dose using XR-RV3 gafchromic films, thermoluminescent detector (TLD) pellets or 2D TL foils and on investigating possible correlation to the on-line dose indicators such as fluoroscopy time, Kerma-area product (KAP) and cumulative air Kerma at reference point (CK). The study aims at defining non-centre-specific European alert thresholds for skin dose in three interventional procedures: chemoembolization of the liver (CE), neuroembolization (NE) and percutaneous coronary interventions (PCI). Skin dose values of >3 Gy (ICRP threshold for skin injuries) were indeed measured in these procedures confirming the need for dose indicators that correlate with maximum skin dose (MSD). However, although MSD showed fairly good correlation with KAP and CK, several limitations were identified challenging the set-up of non-centre-specific European alert thresholds. This paper presents preliminary results of this wide European measurement campaign and focuses on the main challenges in the definition of European alert thresholds.


Assuntos
Procedimentos Cirúrgicos Cardiovasculares/métodos , Radiografia Intervencionista/métodos , Radiometria/instrumentação , Pele/diagnóstico por imagem , Raios X , Absorção de Radiação , Humanos , Concentração Máxima Permitida , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fenômenos Fisiológicos da Pele/efeitos da radiação
15.
Radiat Prot Dosimetry ; 164(1-2): 84-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25316910

RESUMO

In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose.


Assuntos
Cateterismo Cardíaco/métodos , Cristalino/efeitos da radiação , Proteção Radiológica/métodos , Radiografia Intervencionista/métodos , Radiometria/métodos , Algoritmos , Cateterismo Cardíaco/efeitos adversos , Simulação por Computador , Humanos , Cristalino/lesões , Modelos Biológicos , Doses de Radiação , Radiografia Intervencionista/efeitos adversos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Radiol Prot ; 34(3): 509-28, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24938591

RESUMO

Monte Carlo calculations were used to investigate the efficiency of radiation protection equipment in reducing eye and whole body doses during fluoroscopically guided interventional procedures. Eye lens doses were determined considering different models of eyewear with various shapes, sizes and lead thickness. The origin of scattered radiation reaching the eyes was also assessed to explain the variation in the protection efficiency of the different eyewear models with exposure conditions. The work also investigates the variation of eye and whole body doses with ceiling-suspended shields of various shapes and positioning. For all simulations, a broad spectrum of configurations typical for most interventional procedures was considered. Calculations showed that 'wrap around' glasses are the most efficient eyewear models reducing, on average, the dose by 74% and 21% for the left and right eyes respectively. The air gap between the glasses and the eyes was found to be the primary source of scattered radiation reaching the eyes. The ceiling-suspended screens were more efficient when positioned close to the patient's skin and to the x-ray field. With the use of such shields, the Hp(10) values recorded at the collar, chest and waist level and the Hp(3) values for both eyes were reduced on average by 47%, 37%, 20% and 56% respectively. Finally, simulations proved that beam quality and lead thickness have little influence on eye dose while beam projection, the position and head orientation of the operator as well as the distance between the image detector and the patient are key parameters affecting eye and whole body doses.


Assuntos
Imagens de Fantasmas , Proteção Radiológica/instrumentação , Radiologia Intervencionista , Dispositivos de Proteção dos Olhos , Cristalino , Método de Monte Carlo , Radiometria , Contagem Corporal Total
17.
Phys Med Biol ; 59(11): 2747-65, 2014 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-24800943

RESUMO

Monte Carlo calculations are increasingly used to assess stray radiation dose to healthy organs of proton therapy patients and estimate the risk of secondary cancer. Among the secondary particles, neutrons are of primary concern due to their high relative biological effectiveness. The validation of Monte Carlo simulations for out-of-field neutron doses remains however a major challenge to the community. Therefore this work focused on developing a global experimental approach to test the reliability of the MCNPX models of two proton therapy installations operating at 75 and 178 MeV for ocular and intracranial tumor treatments, respectively. The method consists of comparing Monte Carlo calculations against experimental measurements of: (a) neutron spectrometry inside the treatment room, (b) neutron ambient dose equivalent at several points within the treatment room, (c) secondary organ-specific neutron doses inside the Rando-Alderson anthropomorphic phantom. Results have proven that Monte Carlo models correctly reproduce secondary neutrons within the two proton therapy treatment rooms. Sensitive differences between experimental measurements and simulations were nonetheless observed especially with the highest beam energy. The study demonstrated the need for improved measurement tools, especially at the high neutron energy range, and more accurate physical models and cross sections within the Monte Carlo code to correctly assess secondary neutron doses in proton therapy applications.


Assuntos
Método de Monte Carlo , Nêutrons , Terapia com Prótons/métodos , Doses de Radiação , Humanos , Imagens de Fantasmas , Terapia com Prótons/instrumentação , Dosagem Radioterapêutica
18.
J Radiol Prot ; 34(2): 279-96, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24704989

RESUMO

This paper's goal is to assess secondary neutron doses received by paediatric patients treated for intracranial tumours using a 178 MeV proton beam. The MCNPX Monte Carlo model of the proton therapy facility, previously validated through experimental measurements for both proton and neutron dosimetry, was used. First, absorbed dose was calculated for organs located outside the clinical target volume using a series of hybrid computational phantoms for different ages and considering a realistic treatment plan. In general, secondary neutron dose was found to decrease as the distance to the treatment field increases and as the patient age increases. In addition, secondary neutron doses were studied as a function of the beam incidence. Next, neutron equivalent dose was assessed using organ-specific energy-dependent radiation weighting factors determined from Monte Carlo simulations of neutron spectra at each organ. The equivalent dose was found to reach a maximum value of ∼155 mSv at the level of the breasts for a delivery of 49 proton Gy to an intracranial tumour of a one-year-old female patient. Finally, a thorough comparison of the calculation results with published data demonstrated the dependence of neutron dose on the treatment configuration and proved the need for facility-specific and treatment-dependent neutron dose calculations.


Assuntos
Neoplasias Encefálicas/fisiopatologia , Neoplasias Encefálicas/radioterapia , Transferência Linear de Energia , Modelos Biológicos , Nêutrons , Terapia com Prótons/métodos , Contagem Corporal Total/métodos , Absorção de Radiação , Adolescente , Adulto , Criança , Pré-Escolar , Simulação por Computador , Feminino , Humanos , Lactente , Masculino , Especificidade de Órgãos , Doses de Radiação , Dosagem Radioterapêutica , Espalhamento de Radiação , Adulto Jovem
19.
Radiat Prot Dosimetry ; 161(1-4): 449-53, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24759916

RESUMO

Relative Biological Effectiveness (RBE) values are used to characterise the biological efficiency of different radiation qualities relative to photon irradiations. The RBE-high linear energy transfer (LET) relation for ion irradiations presents general features that the authors propose to look at using a nanometric description of the energy deposition of these ion irradiations (protons and alphas of different energies). In this work, the simulation of the energy transfer points in the tracks was made by Monte Carlo method using the Geant4-DNA processes and a nanometric description of the target of interest for studying biological effects, the DNA molecule. Results were obtained concerning the sensitive volume to be considered for direct DNA clustered damages that could be related to late biological effects.


Assuntos
Partículas alfa , DNA/efeitos da radiação , Transferência Linear de Energia , Radiometria/instrumentação , Radiometria/métodos , Algoritmos , Animais , Linhagem Celular/efeitos da radiação , Análise por Conglomerados , DNA/química , Dano ao DNA , Hélio/química , Humanos , Íons , Método de Monte Carlo , Neônio , Prótons , Doses de Radiação , Eficiência Biológica Relativa
20.
Radiat Prot Dosimetry ; 161(1-4): 469-73, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24615262

RESUMO

The purpose of this work is to evaluate the influence of the chromatin condensation on the number of direct double-strand break (DSB) damages induced by ions. Two geometries of chromosome territories containing either condensed or decondensed chromatin were implemented as biological targets in the Geant4 Monte Carlo simulation code and proton and alpha irradiation was simulated using the Geant4-DNA processes. A DBSCAN algorithm was used in order to detect energy deposition clusters that could give rise to single-strand breaks or DSBs on the DNA molecule. The results of this study show an increase in the number and complexity of DNA DSBs in condensed chromatin when compared with decondensed chromatin.


Assuntos
Cromatina/química , Quebras de DNA de Cadeia Dupla , DNA/análise , Algoritmos , Partículas alfa , Animais , Cromossomos/ultraestrutura , Análise por Conglomerados , Simulação por Computador , DNA/química , Dano ao DNA , Elétrons , Humanos , Íons , Transferência Linear de Energia , Método de Monte Carlo , Nucleossomos/química , Prótons , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...