Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Biomater ; 103: 81-91, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31863910

RESUMO

Electrical stimulation of the muscle has been proven efficacious in preventing atrophy and/or reanimating paralyzed muscles. Intramuscular electrodes made from metals have significantly higher Young's Moduli than the muscle tissues, which has the potential to cause chronic inflammation and decrease device performance. Here, we present an intramuscular electrode made from an elastomeric conducting polymer composite consisting of PEDOT-PEG copolymer, silicone and carbon nanotubes (CNT) with fluorosilicone insulation. The electrode wire has a Young's modulus of 804 (±99) kPa, which better mimics the muscle tissue modulus than conventional stainless steel (SS) electrodes. Additionally, the non-metallic composition enables metal-artifact free CT and MR imaging. These soft wire (SW) electrodes present comparable electrical impedance to SS electrodes of similar geometric surface area, activate muscle at a lower threshold, and maintain stable electrical properties in vivo up to 4 weeks. Histologically, the SW electrodes elicited significantly less fibrotic encapsulation and less IBA-1 positive macrophage accumulation than the SS electrodes at one and three months. Further phenotyping the macrophages with the iNOS (pro-inflammatory) and ARG-1 (pro-healing) markers revealed significantly less presence of pro-inflammatory macrophage around SW implants at one month. By three months, there was a significant increase in pro-healing macrophages (ARG-1) around the SW implants but not around the SS implants. Furthermore, a larger number of AchR clusters closer to SW implants were found at both time points compared to SS implants. These results suggest that a softer implant encourages a more intimate and healthier electrode-tissue interface. STATEMENT OF SIGNIFICANCE: Intramuscular electrodes made from metals have significantly higher Young's Moduli than the muscle tissues, which has the potential to cause chronic inflammation and decrease device performance. Here, we present an intramuscular electrode made from an elastomeric conducting polymer composite consisting of PEDOT-PEG copolymer, silicone and carbon nanotubes with fluorosilicone insulation. This elastomeric composite results in an electrode wire with a Young's modulus mimicking that of the muscle tissue, which elicits significantly less foreign body response compared to stainless steel wires. The lack of metal in this composite also enables metal-artifact free MRI and CT imaging.


Assuntos
Elastômeros/química , Eletrodos Implantados , Músculos/fisiologia , Animais , Materiais Biocompatíveis/química , Eletroquímica , Imageamento por Ressonância Magnética , Masculino , Músculos/diagnóstico por imagem , Ratos Sprague-Dawley , Receptores Colinérgicos/metabolismo , Microtomografia por Raio-X
2.
PLoS Negl Trop Dis ; 13(3): e0007210, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30845250

RESUMO

Control of arbovirus transmission remains focused on vector control through application of insecticides directly to the environment. However, these insecticide applications are often reactive interventions that can be poorly-targeted, inadequate for localized control during outbreaks, and opposed due to environmental and toxicity concerns. In this study, we developed endectocide-treated feed as a systemic endectocide for birds to target blood feeding Culex tarsalis, the primary West Nile virus (WNV) bridge vector in the western United States, and conducted preliminary tests on the effects of deploying this feed in the field. In lab tests, ivermectin (IVM) was the most effective endectocide tested against Cx. tarsalis and WNV-infection did not influence mosquito mortality from IVM. Chickens and wild Eurasian collared doves exhibited no signs of toxicity when fed solely on bird feed treated with concentrations up to 200 mg IVM/kg of diet, and significantly more Cx. tarsalis that blood fed on these birds died (greater than 80% mortality) compared to controls (less than 25% mortality). Mosquito mortality following blood feeding correlated with IVM serum concentrations at the time of blood feeding, which dropped rapidly after the withdrawal of treated feed. Preliminary field testing over one WNV season in Fort Collins, Colorado demonstrated that nearly all birds captured around treated bird feeders had detectable levels of IVM in their blood. However, entomological data showed that WNV transmission was non-significantly reduced around treated bird feeders. With further development, deployment of ivermectin-treated bird feed might be an effective, localized WNV transmission control tool.


Assuntos
Controle de Doenças Transmissíveis/métodos , Culex/efeitos dos fármacos , Inseticidas/farmacologia , Mosquitos Vetores/efeitos dos fármacos , Doenças das Aves Domésticas/prevenção & controle , Febre do Nilo Ocidental/prevenção & controle , Vírus do Nilo Ocidental/efeitos dos fármacos , Animais , Galinhas , Colorado , Columbidae , Culex/virologia , Mosquitos Vetores/virologia , Doenças das Aves Domésticas/tratamento farmacológico , Doenças das Aves Domésticas/mortalidade , Doenças das Aves Domésticas/transmissão , Febre do Nilo Ocidental/tratamento farmacológico , Febre do Nilo Ocidental/mortalidade , Febre do Nilo Ocidental/transmissão
3.
Adv Healthc Mater ; 8(9): e1801311, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30843365

RESUMO

State-of-the-art intraneural electrodes made from silicon or polyimide substrates have shown promise in selectively modulating efferent and afferent activity in the peripheral nervous system. However, when chronically implanted, these devices trigger a multiphase foreign body response ending in device encapsulation. The presence of encapsulation increases the distance between the electrode and the excitable tissue, which not only reduces the recordable signal amplitude but also requires increased current to activate nearby axons. Herein, this study reports a novel conducting polymer based intraneural electrode which has Young's moduli similar to that of nerve tissue. The study first describes material optimization of the soft wire conductive matrix and evaluates their mechanical and electrochemical properties. Second, the study demonstrates 3T3 cell survival when cultured with media eluted from the soft wires. Third, the study presents acute in vivo functionality for stimulation of peripheral nerves to evoke force and compound muscle action potential in a rat model. Furthermore, comprehensive histological analyses show that soft wires elicit significantly less scar tissue encapsulation, less changes to axon size, density and morphology, and reduced macrophage activation compared to polyimide implants in the sciatic nerves at 1 month postimplantation.


Assuntos
Elastômeros/química , Microeletrodos , Nervos Periféricos/citologia , Células 3T3 , Animais , Sobrevivência Celular/fisiologia , Eletroquímica , Ativação de Macrófagos/fisiologia , Camundongos , Microscopia Eletrônica de Varredura , Nanotubos de Carbono/química , Nanotubos de Carbono/ultraestrutura , Nervos Periféricos/ultraestrutura , Ratos
4.
J Phys Chem B ; 109(43): 20180-5, 2005 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-16853608

RESUMO

Nanocomposite thermites are attractive materials for their diverse applications from metallurgy to ordnance technologies. While there are a plethora of combinations of fuel and oxidizers, this work shows that the composite's overall performance is intimately tied to how the fuel and oxidizer are prepared and combined. Comparison of the combustion velocities of two separate ternary mixtures of Al-Fe(2)O(3)-SiO(2), one prepared in situ using sol-gel processing and the other prepared by physically mixing discrete nanoscale particles, demonstrated different burning behaviors as a result of preparation technique. The stoichiometry of the two sets of thermite was varied to examine the influence of SiO(2) on combustion velocity as a means to control the reaction behavior. For pure Fe(2)O(3) + Al reactions, results show that the sol-gel synthesized materials (40 m/s) exhibit increased velocities over the physically mixed materials (9 m/s) by approximately 4 times. This trend is not observed, however, upon addition of SiO(2) to the thermite mixture; ternary thermites with 40 wt % SiO(2) showed decreased burn velocities of 0.02 m/s for sol-gel prepared thermites compared to 0.2 m/s for their physically mixed counterparts. The observed trends are believed to be caused by the unique mixing between the Fe(2)O(3) and SiO(2) phases resulting from the two synthesis techniques.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...