1.
J Acoust Soc Am ; 132(4): EL310-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23039570

RESUMO

Divers constitute a potential threat to waterside infrastructures. Active diver detection sonars are available commercially but present some shortcomings, particularly in highly reverberant environments. This has led to research on passive sonar for diver detection. Passive detection of open-circuit UBA (underwater breathing apparatus) has been demonstrated. This letter reports on the detection of a diver wearing closed-circuit UBA (rebreather) in an operational harbor. Beamforming is applied to a passive array of 10 hydrophones in a pseudo-random linear arrangement. Experimental results are presented demonstrating detection of the rebreather at ranges up to 120 m and are validated by GPS ground truth.


Assuntos
Acústica , Mergulho , Equipamentos Esportivos , Água , Acústica/instrumentação , Desenho de Equipamento , Expiração , Sistemas de Informação Geográfica , Humanos , Inalação , Movimento (Física) , Ruído , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Espectrografia do Som , Fatores de Tempo , Transdutores
2.
Med Phys ; 28(4): 638-53, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11339762

RESUMO

Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.


Assuntos
Radiometria , Anisotropia , Modelos Estatísticos , Imagens de Fantasmas , Fótons , Radioterapia/métodos , Água
3.
Phys Med Biol ; 45(5): 1319-34, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10843107

RESUMO

In this paper, we present results from three different simulation models that are used to determine the dose distribution around a 188W/188Re coronary brachytherapy source with EGS4 Monte Carlo simulations. The three models are found to give similar results within 10%. Agreement was found with experimental data from measurements in a PMMA phantom. It has been shown that in the therapeutically relevant region the beta line source can be characterized by the radial depth-dose distribution in water.


Assuntos
Braquiterapia/métodos , Angioplastia Coronária com Balão , Fenômenos Biofísicos , Biofísica , Braquiterapia/estatística & dados numéricos , Vasos Coronários/efeitos da radiação , Humanos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Polimetil Metacrilato , Radioisótopos/uso terapêutico , Rênio/uso terapêutico , Tungstênio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...