Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Nutr Assoc ; 41(6): 541-550, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34252340

RESUMO

OBJECTIVE: The purpose of the present study was to examine the effect of capsiate supplementation on energy intake, self-reported appetite-related sensations, energy expenditure, fat oxidation, and autonomic parameters with and without an exercise intervention. METHODS: Thirteen healthy men completed four randomized trials: two trials for the control condition (without exercise), one with capsiate supplementation (CTRLcap) and one with a placebo (CTRLpla), and two trials for the exercise condition, one with capsiate supplementation (EXcap) and one with placebo (EXpla). Exercise sessions were performed 150 min after the consumption of a standardized breakfast, and supplementation 115 min after consumption of breakfast. An ad libitum buffet was offered 200 min following the completion of the standardized breakfast, and energy intake (EI) and relative energy intake (REI) (relative energy intake = energy intake - energy expenditure related to exercise) were evaluated. RESULTS: There were no significant effects on EI, self-reported appetite sensations, fat oxidation, and energy expenditure. REI was reduced in conditions involving EX when compared to CTRL. A low-frequency to high-frequency ratio for heart rate variability was higher in CTRLcap (1.6 ± 1.1) vs. CTRLpla (1.2 ± 0.9) (p = 0.025; d = 0.39). CONCLUSION: Acute capsiate supplementation combined with aerobic exercise has limited effects on the examined variables (EI, REI, fat oxidation, energy expenditure, and autonomic parameters), while changes in the autonomic nervous system function in the absence of exercise may have occurred without influencing other variables. CLINICAL TRIAL REGISTRATION: ensaiosclinicos.gov.br number, RBR-5pckyr https://ensaiosclinicos.gov.br/rg/RBR-5pckyr.


Assuntos
Apetite , Ingestão de Energia , Apetite/fisiologia , Capsaicina/análogos & derivados , Suplementos Nutricionais , Ingestão de Energia/fisiologia , Exercício Físico/fisiologia , Humanos , Masculino
2.
J Strength Cond Res ; 35(3): 586-595, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33470602

RESUMO

ABSTRACT: Boffey, D, Clark, NW, and Fukuda, DH. Efficacy of rest redistribution during squats: Considerations for strength and sex. J Strength Cond Res 35(3): 586-595, 2021-This study examined the kinematic, perceptual, and heart rate responses to rest redistribution (RR) and traditional sets (TS) during the barbell back squat for men and women possessing a wide range of strength levels. Forty-five resistance-trained subjects (30 men and 15 women) performed 40 repetitions of the barbell squat with 65% 1RM load with TS (4 × 10 repetitions, 3-minute rest) or RR (10 × 4 repetitions, 1-minute rest), in a randomized order on days separated by ≥72 hours. The significance was set at p ≤ 0.05 for all statistical analyses. The mean velocity (MV) maintenance was significantly higher for RR compared with TS (87.70 ± 4.50% vs. 84.07 ± 4.48%, respectively; p < 0.01, d = 0.35). Rating of perceived exertion (active muscles) was significantly lower for RR compared with TS (5.38 ± 1.42 vs. 6.08 ± 1.43, respectively; p = 0.02, d = -0.35). Rating of perceived exertion (overall) was also significantly lower for RR compared with TS (5.60 ± 1.40 vs. 6.48 ± 1.49, respectively; p = 0.02, d = -0.37). The relative strength ratio (relative strength ratio; squat 1RM: body mass) was significantly correlated with the difference in MV maintenance between RR and TS (r = -0.34, p = 0.02). No sex-based differences (p > 0.05) were found for any dependent variables. Rest redistribution produced significantly higher mean HR (143.25 ± 21.11 vs. 135.05 ± 20.74, p < 0.01) and minimum HR (102.77 ± 19.58 vs. 95.97 ± 22.17, p < 0.01). Subjects were better able to maintain velocity with RR compared with TS, while experiencing less perceived effort. Rest redistribution can be recommended for both men and women, but very strong individuals may not improve their velocity maintenance with RR to the same extent as less strong individuals.


Assuntos
Treinamento Resistido , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Força Muscular , Postura , Projetos de Pesquisa , Caracteres Sexuais
3.
Nutrients ; 12(8)2020 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-32784372

RESUMO

This study examined the cardiac autonomic responses, as measured by heart rate variability (HRV), during cycling exercise and short-term rest after energy drink consumption. Seventeen participants (seven males and 10 females; age: 22.8 ± 3.5 years; BMI: 24.3 ± 3.3 kg/m2) completed this double-blind, placebo-controlled, counterbalanced crossover design study. Participants received an energy drink formula containing 140 mg of caffeine and a placebo in a randomized order before completing a 10-min steady-state warm up (WUP) and a graded exercise test to exhaustion (GXT) followed by a 15-min short-term rest (STR) period. Heartbeat intervals were recorded using a heart rate monitor. Data were divided into WUP, GXT, and STR phases, and HRV parameters were averaged within each phase. Additionally, root mean square of the standard deviation of R-R intervals (RMSSD) during GXT was analyzed to determine the HRV threshold. Separate two-way (sex (male vs. female) x drink (energy drink vs. placebo)) repeated measures ANOVA were utilized. Significant increases in high frequency (HF) and RMSSD were shown during WUP after energy drink consumption, while interactions between drink and sex were observed for HRV threshold parameters (initial RMSSD and rate of RMSSD decline). No significant differences were noted during STR. Energy drink consumption may influence cardiac autonomic responses during low-intensity exercise, and sex-based differences in response to graded exercise to exhaustion may exist.


Assuntos
Ciclismo/fisiologia , Ingestão de Líquidos/fisiologia , Bebidas Energéticas , Frequência Cardíaca/fisiologia , Fatores Sexuais , Análise de Variância , Cafeína/administração & dosagem , Estudos Cross-Over , Método Duplo-Cego , Metabolismo Energético/fisiologia , Teste de Esforço , Feminino , Humanos , Masculino , Esforço Físico/fisiologia , Descanso/fisiologia , Adulto Jovem
4.
J Sports Sci ; 38(14): 1615-1623, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32316854

RESUMO

Post-activation potentiation likely acutely improves power-based performance; however, few studies have demonstrated improved endurance performance. Forty collegiate female rowers performed isometric potentiating (ISO), dynamic potentiating (DYN) and control (CON) warm-up protocols on a rowing ergometer, followed by a three-minute all-out test to evaluate their total distance, peak power, mean power, critical power, anaerobic working capacity (W') and stroke rate. Fifteen-second splits were also analysed. ISO consisted of 5 × 5-second static muscle actions with the ergometer handle rendered immovable with a nylon strap, while DYN consisted of 2 × 10-second all-out rowing bouts, separated by a 2-minute rest interval. The participants were divided into high and low experience groups by median experience level (3.75 years) for statistical analysis. Significant differences (DYN > CON; p < 0.05) were found for distance (+5.6 m), mean power (+5.9 W) and W' (+1561.6 J) for more experienced rowers (n = 19) and no differences for less experienced rowers (n = 18). Mean power in DYN was significantly greater than CON and ISO in the 15-30, 30-45, 45-60 and 60-75 second intervals independent of experience level. These results suggest that DYN may benefit experienced female rowers and that these strategies might benefit a greater power output over shorter distances regardless of experience.


Assuntos
Resistência Física/fisiologia , Exercício de Aquecimento , Esportes Aquáticos/fisiologia , Estudos Cross-Over , Teste de Esforço , Feminino , Humanos , Contração Isométrica/fisiologia , Adulto Jovem
5.
J Int Soc Sports Nutr ; 17(1): 10, 2020 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-32054486

RESUMO

BACKGROUND: Thermogenic fitness drink formulas (TFD) have been shown to increase energy expenditure and markers of lipid metabolism. The purpose of the current study was to compare TFD formulas containing different caffeine concentrations versus a placebo drink on energy expenditure and lipid metabolism at rest and during exercise. METHODS: Thirty-two recreationally active participants (22.9 ± 0.7 y, 167.1 ± 1.4 cm, 68.8 ± 2.0 kg, 24.0 ± 1.2% fat) who were regular caffeine consumers, participated in this randomized, double-blind, crossover design study. Participants reported to the laboratory on three occasions, each of which required consumption of either a TFD containing 140 mg or 100 mg of caffeine or a placebo. Baseline measurements of resting energy expenditure (REE) and resting fat oxidation (RFO) were assessed using indirect calorimetry as well as measurements of serum glycerol concentration. Measurements were repeated at 30, 60, 90 min post-ingestion. Following resting measures, participants completed a graded exercise test to determine maximal oxygen uptake (V̇O2max), maximal fat oxidation (MFO) and the exercise intensity that elicits MFO (Fatmax), and total energy expenditure (EE). RESULTS: A significant interaction was shown for REE (p < 0.01) and RFO (p < 0.01). Area under the curve analysis showed an increased REE for the 140 mg compared to the 100 mg formula (p = 0.02) and placebo (p < 0.01) and an increased REE for the 100 mg formula compared to placebo (p = 0.02). RFO significantly decreased for caffeinated formulas at 30 min post ingestion compared to placebo and baseline (p < 0.01) and significantly increased for the 140 mg formula at 60 min post-ingestion (p = 0.03). A main effect was shown for serum glycerol concentrations over time (p < 0.01). No significant differences were shown for V̇O2max (p = 0.12), Fatmax (p = 0.22), and MFO (p = 0.05), and EE (p = 0.08) across drinks. CONCLUSIONS: Our results suggest that TFD formulas containing 100 and 140 mg of caffeine are effective in increasing REE and that a 40 mg of caffeine difference between the tested formulas may impact REE and RFO in healthy individuals within 60 min of ingestion.


Assuntos
Cafeína/farmacologia , Metabolismo Energético , Exercício Físico , Metabolismo dos Lipídeos , Substâncias para Melhoria do Desempenho/farmacologia , Adolescente , Adulto , Bebidas , Calorimetria Indireta , Estudos Cross-Over , Método Duplo-Cego , Teste de Esforço , Feminino , Glicerol/sangue , Humanos , Masculino , Descanso , Adulto Jovem
6.
Eur J Appl Physiol ; 120(3): 643-651, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31974857

RESUMO

PURPOSE: The primary purpose of this study was to examine the influence of different work-to-rest ratios on relative energy system utilization during short-term upper-body sprint interval training (SIT) protocols. METHODS: Forty-two recreationally trained men were randomized into one of three training groups [10 s work bouts with 2 min of rest (10:2, n = 11) or 4 min of rest (10:4, n = 11), or 30 s work bouts with 4 min of rest (30:4, n = 10)] or a control group (CON, n = 10). Participants underwent six training sessions over 2 weeks with 4-6 'all-out' sprints. Participants completed an upper body Wingate test (30 s 'all-out' using 0.05 kg kg-1 of the participant's body mass) pre- and post-intervention from which oxygen consumption and blood lactate were used to estimate oxidative, glycolytic, and adenosine triphosphate-phosphocreatine (ATP-PCr) energy system provisions. An analysis of covariance was performed on all testing measurements collected at post with the associated pre-values used as covariates. RESULTS: Relative energy contribution (p = 0.026) and energy expenditure (p = 0.019) of the ATP-PCr energy system were greater in 10:4 (49.9%; 62.1 kJ) compared to CON (43.1%; 47.2 kJ) post training. No significant differences were found between groups in glycolytic or oxidative energy contribution over a 30 s upper body Wingate test. CONCLUSION: SIT protocols with smaller work-to-rest ratios may enhance ATP-PCr utilization in a 30 s upper body Wingate over a 2-week intervention.


Assuntos
Metabolismo Energético , Treinamento Intervalado de Alta Intensidade , Adulto , Humanos , Masculino , Extremidade Superior/fisiologia , Adulto Jovem
7.
J Sports Sci Med ; 18(2): 359-368, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31191107

RESUMO

The purpose of the present study is two-fold. First, we evaluated whether 8-weeks of combined training (high-intensity intermittent plus strength training) may change brain derived neurotropic factor (BDNF) and lipid parameters (triacylglycerol, HDL-c and non-HDL) in a fasted state. Second, we investigated the effect of an acute session of high-intensity intermittent exercise followed by strength training on systemic BDNF and lipid parameters pre- and post 8-weeks of training. Twenty-one healthy and physically active men were divided into two groups: high-intensity intermittent exercise combined with strength training (HSG; n = 11) and control (CG; n = 10). The HSG exercised for one minute at 100% of speedVO2max (sVO2max) interspersed with one minute of passive recovery followed by strength training (8 exercises with 8-12 repetition maximum loads) for 8-weeks. Heart rate variability, blood pressure, lipid profile, and BDNF concentrations were measured in the fasted state pre- and post-exercise and before and after the 8-week training period. After 8-weeks of exercise training, there was an increase in spectral high frequency component (ms2) and RR interval (p < 0.05), a decreased spectral low frequency component (nu) and heart rate values (p < 0.05), an increase in HDL-c (p < 0.001), and lower BDNF concentrations (p < 0.001). These results suggest that 8-weeks of high-intensity intermittent exercise combined with strength exercise is an effective protective cardio-metabolic strategy capable of increasing HDL-c and BDNF concentrations after an acute exercise session. In the long-term, the modulation on BDNF and HDL-c concentrations may be a determining factor for protection against neurological and cardiovascular diseases.


Assuntos
Sistema Nervoso Autônomo/fisiologia , Fator Neurotrófico Derivado do Encéfalo/sangue , Treinamento Intervalado de Alta Intensidade , Lipídeos/sangue , Treinamento Resistido , Adulto , Pressão Sanguínea , HDL-Colesterol/sangue , Frequência Cardíaca , Humanos , Masculino , Força Muscular , Consumo de Oxigênio , Adulto Jovem
8.
Respir Physiol Neurobiol ; 262: 12-19, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30660860

RESUMO

The objective was to compare the metabolic influence of varying work-to-rest ratios during upper body sprint interval training (SIT). Forty-two recreationally-trained men were randomized into a training group [10 s work - 2 min of rest (10:2) or 4 min of rest (10:4), or 30 s work - 4 min of rest (30:4)] or a control group (CON). Participants underwent six training sessions over two weeks. Assessments consisted of a graded exercise test [maximal oxygen consumption (VO2peak) and peak power output (PPO)], four constant-work rate trials [critical power, anaerobic working capacity, and electromyographic fatigue threshold], and an upper body Wingate test (mean/peak power and total work). Post-training absolute and relative VO2peak was greater than pre-training for 30:4 (p = .005 and p = .009, respectively), but lower for CON (p = .001 and p = .006, respectively). Post-training PPO was greater in 30:4 (p < .001). No differences were observed during the constant-work rate trials or Wingate test. Traditional SIT appears to have enhanced VO2peak in the upper body over a short-term two-week intervention.


Assuntos
Desempenho Atlético/fisiologia , Treinamento Intervalado de Alta Intensidade/métodos , Extremidade Superior/fisiologia , Composição Corporal , Eletromiografia , Teste de Esforço , Humanos , Masculino , Fadiga Muscular/fisiologia , Músculo Esquelético/fisiologia , Consumo de Oxigênio , Descanso , Fatores de Tempo , Adulto Jovem
9.
Int J Exerc Sci ; 11(4): 980-986, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30338018

RESUMO

The purpose of this study was to compare power outputs of the flying start to the stationary start method on an electromagnetically-braked cycle ergometer. Twenty advanced resistance-trained men (age 24.6 ± 4.5 years; 25.4 ± 2.5 kg/m2) volunteered to participate in this study. A counter-balanced, repeated-measures design was utilized to randomly assign participants to either the flying start or the stationary start for their first Wingate test. Paired t tests were used to evaluate mean differences between start methods. Peak power (PP), mean power (MP), total work (TW), peak cadence (PC), mean cadence (MC), and time to reach peak power (TPP) were recorded. Start method revealed significant differences for PP (p<0.01; flying start = 1,111 ± 42 W vs. stationary start = 854 ± 41 W) and PC attainment (p<0.01; flying start = 167 ± 7 RPM vs. stationary start = 128 ± 5 RPM). Start method did not significantly affect MP (p=0.73; flying start 673 ± 30 W vs. stationary start 657 ± 34 W) or MC (p=0.61; flying start 102 ± 5 RPM vs. 99 ± 4 RPM). The flying start method allowed for not only a greater PP but also a faster TPP (0.24 ± 0.02 seconds). In contrast, TPP was not attained until approximately one-third of the stationary start test (10.3 ± 0.4 seconds). This study showed that the traditional flying start allowed higher PP and PC outputs when compared to the alternative stationary start method in a sample of advanced resistance-trained male participants.

10.
J Exerc Sci Fit ; 16(1): 12-15, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30662486

RESUMO

BACKGROUND/OBJECTIVE: Wintertime thermal inversions in narrow mountain valleys create a ceiling effect, increasing concentration of small particulate matter (PM2.5). Despite potential health risks, many people continue to exercise outdoors in thermal inversions. This study measured the effects of ambient PM2.5 exposure associated with a typical thermal inversion on exercise performance, pulmonary function, and biological markers of inflammation. METHODS: Healthy, active adults (5 males, 11 females) performed two cycle ergometer time trials outdoors in a counterbalanced design: 1) low ambient PM2.5 concentrations (<12 µg/m3), and 2) an air quality index (AQI) ranking of "yellow." Variables of interest were exercise performance, exhaled nitric oxide (eNO), c-reactive protein (CRP), forced vital capacity (FVC), and forced expiratory volume in 1 s (FEV1). RESULTS: Despite a significant difference in mean PM2.5 concentration of 9.3 ±â€¯3.0 µg/m3 between trials (p < .001), there was no significant difference (p = .424) in the distance covered during low PM2.5 conditions (9.9 ±â€¯1.7 km) compared to high PM2.5 conditions (10.1 ±â€¯1.5 km). There were no clinically significant differences across time or between trials for eNO, CRP, FVC, or FEV1. Additionally, there were no dose-response relationships (p > .05) for PM2.5 concentration and the measured variables. CONCLUSION: An acute bout of vigorous exercise during an AQI of "yellow" did not diminish exercise performance in healthy adults, nor did it have a negative effect on pulmonary function or biological health markers. These variables might not be sensitive to small changes from acute, mild PM2.5 exposure.

11.
J Sci Med Sport ; 21(2): 202-206, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28807684

RESUMO

OBJECTIVES: This study compared an 85-tooth versus the standard 62-tooth chainring for power outputs during a Wingate test using a Velotron electromagnetically-braked cycle ergometer. DESIGN: All participants completed trials using both chainring sizes in a repeated-measures cross-over design. METHODS: Resistance-trained male participants (n=20, 24.6±4.5years) performed two Wingate tests separated by at least 48h. Peak power (PP), mean power (MP), fatigue index (FI), peak cadence, mean cadence, and total work (TW) were recorded. RESULTS: Peak power was not significantly different (p=0.10) between trials (62-tooth=1111±187W vs. 85-tooth=1188±103W). However, MP, mean cadence, and TW were significantly greater (p<0.01) for the 85-tooth trial (869±114W, 131±16rpm, and 26,063±3418J) compared to the 62-tooth test (673±136W, 102±24rpm, and 20,199±4066J). Fatigue index was reduced during the 85-tooth trial (49.9±9.1% vs. 61.6±8.8%; p<0.01). Agreement was poor with most ICCs≈0.19 and large SEMs. CONCLUSIONS: The two options for chainrings on Velotron cycle ergometers should not be interchangeably used with the Wingate test software; the 62-tooth ring is recommended for most applications. Individuals who can attain peak cadence >180rpm have less variability and tend to achieve higher power outputs on the 62-tooth ring. We suspect that the manufacturer's software limits peak cadence to 182rpm when using the 85-tooth chainring.


Assuntos
Ciclismo/fisiologia , Teste de Esforço/instrumentação , Adulto , Variação Antigênica , Estudos Cross-Over , Fadiga/fisiopatologia , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
12.
PLoS One ; 11(4): e0153146, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27073854

RESUMO

This study evaluated the validity and reliability of the BodyMetrix™ BX2000 A-mode ultrasound for estimating percent body fat (%BF) in athletes by comparing it to skinfolds and the BOD POD. Forty-five (22 males, 23 females) National Collegiate Athletic Association (NCAA) Division-I athletes volunteered for this study. Subjects were measured once in the BOD POD then twice by two technicians for skinfolds and ultrasound. A one-way repeated-measures ANOVA revealed significant differences between body composition methods (F = 13.24, p < 0.01, η² = 0.24). This difference was further explained by a sex-specific effect such that the mean difference between ultrasound and BOD POD was large for females (~ 5% BF) but small for males (~ 1.5% BF). Linear regression using the %BF estimate from ultrasound to predict %BF from BOD POD resulted in an R2 = 0.849, SEE = 2.6% BF and a TE = 4.4% BF. The inter-rater intraclass correlation (ICC) for skinfold was 0.966 with a large 95% confidence interval (CI) of 0.328 to 0.991. The inter-rater ICC for ultrasound was 0.987 with a much smaller 95% CI of 0.976 to 0.993. Both skinfolds and ultrasound had test-retest ICCs ≥ 0.996. The BX2000 ultrasound device had excellent test-retest reliability, and its inter-rater reliability was superior to the skinfold method. The validity of this method is questionable, particularly for female athletes. However, due to its excellent reliability, coaches and trainers should consider this portable and easy to use A-mode ultrasound to assess body composition changes in athletes.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Atletas , Composição Corporal/fisiologia , Ultrassonografia/métodos , Imagem Corporal Total/métodos , Adolescente , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Dobras Cutâneas , Adulto Jovem
13.
J Sports Sci ; 34(9): 852-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26238160

RESUMO

Investigations in the 1990s evaluated the influence of breathing assemblies on respiratory variables at rest and during exercise; however, research on new models of breathing assemblies is lacking. This study compared metabolic gas analysis data from a mouthpiece with a noseclip (MOUTH) and a face mask (MASK). Volunteers (7 males, 7 females; 25.1 ± 2.7 years) completed two maximal treadmill tests within 1 week, one MOUTH and one MASK, in random order. The difference in maximal oxygen consumption (VO2max) between MOUTH (52.7 ± 11.3 ml · kg(-1) · min(-1)) and MASK (52.2 ± 11.7 ml · kg(-1) · min(-1)) was not significant (P = 0.53). Likewise, the mean MOUTH-MASK differences in minute ventilation (VE), fraction of expired oxygen (FEO2) and carbon dioxide (FECO2), respiration rate (RR), tidal volume (Vt), heart rate (HR), and rating of perceived exertion (RPE) at maximal and submaximal intensities were not significant (P > 0.05). Furthermore, there was no systematic bias in the error scores (r = -0.13, P = 0.66), and 12 of the 14 participants had a VO2max difference of ≤3 ml · kg(-1) · min(-1) between conditions. Finally, there was no clear participant preference for using the MOUTH or MASK. Selection of MOUTH or MASK will not affect the participant's gas exchange or breathing patterns.


Assuntos
Dióxido de Carbono/análise , Teste de Esforço/métodos , Oxigênio/análise , Respiração , Descanso/fisiologia , Corrida/fisiologia , Adulto , Teste de Esforço/instrumentação , Face , Fadiga , Feminino , Frequência Cardíaca , Humanos , Masculino , Boca , Consumo de Oxigênio , Esforço Físico , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...