Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
J Appl Lab Med ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38573939

RESUMO

BACKGROUND: Point-of-care testing in the emergency department decreases wait times and supports evidence-based patient care. However, hurdles to successful implementation include management of interdisciplinary work flows and establishment of an effective quality control program. As COVID-19 testing is now integrated into screening protocols in emergency and urgent care settings, hospital systems must maintain flexible and adaptable respiratory virus testing to adapt to regional trends in transmission. In response to this challenge, our hospital system established a point-of-care respiratory virus laboratory within the emergency department to test for COVID, influenza A/B, and respiratory syncytial virus (RSV). However, maintaining regulatory compliance and standardized protocols within such a dynamic environment became challenging. METHODS: We launched a quality improvement initiative to support improved performance and efficiency in the point-of-care laboratory with a focus on regulatory benchmarks. Following a period of observation and discussion with key stakeholders in the emergency department and pathology, an audit tool was developed and to be deployed in collaboration with ED nursing. Utilizing the new tool, ED nursing would perform audits in parallel to audits performed by point-of-care staff. RESULTS: Prior to the intervention, the average audit score was approximately 55%; 6 months following the intervention, audit scores have remained stable at approximately 80%, representing a significant improvement in regulatory compliance. CONCLUSIONS: Creation of a regulatory tool enabled real-time cross-departmental monitoring of regulatory compliance. These findings underscore the importance of developing transparent interdisciplinary work flows and effective communication to improve patient care.

2.
Addiction ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561602

RESUMO

BACKGROUND AND AIMS: People who inject drugs (PWID) are at risk for adverse outcomes across multiple dimensions. While evidence-based interventions are available, services are often fragmented and difficult to access. We measured the effectiveness of an integrated care van (ICV) that offered services for PWID. DESIGN, SETTING AND PARTICIPANTS: This was a cluster-randomized trial, which took place in Baltimore, MD, USA. Prior to randomization, we used a research van to recruit PWID cohorts from 12 Baltimore neighborhoods (sites), currently served by the city's mobile needle exchange program. INTERVENTION AND COMPARATOR: We randomized sites to receive weekly visits from the ICV (n = 6) or to usual services (n = 6) for 14 months. The ICV offered case management; buprenorphine/naloxone; screening for HIV, hepatitis C virus and sexually transmitted infections; HIV pre-exposure prophylaxis; and wound care. MEASUREMENTS: The primary outcome was a composite harm mitigation score that captured access to evidence-based services, risk behaviors and adverse health events (range = 0-15, with higher numbers indicating worse status). We evaluated effectiveness by comparing changes in the composite score at 7 months versus baseline in the two study arms. FINDINGS: We enrolled 720 cohort participants across the study sites (60 per site) between June 2018 and August 2019: 38.3% women, 72.6% black and 85.1% urine drug test positive for fentanyl. Over a median of 10.4 months, the ICV provided services to 734 unique clients (who may or may not have been cohort participants) across the six intervention sites, including HIV/hepatitis C virus testing in 577 (78.6%) and buprenorphine/naloxone initiation in 540 (74%). However, only 52 (7.2%) of cohort participants received services on the ICV. The average composite score decreased at 7 months relative to baseline, with no significant difference in the change between ICV and usual services (difference in differences: -0.31; 95% confidence interval: -0.70, 0.08; P = 0.13). CONCLUSIONS: This cluster-randomized trial in Baltimore, MD, USA, found no evidence that weekly neighborhood visits from a mobile health van providing injection-drug-focused services improved access to services and outcomes among people who injected drugs in the neighborhood, relative to usual services. The van successfully served large numbers of clients but unexpectedly low use of the van by cohort participants limited the ability to detect meaningful differences.

4.
J Biophotonics ; 17(1): e202300279, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37703421

RESUMO

We demonstrate a portable, compact system to perform absorption-based enzymatic assays at a visible wavelength of 639 nm on a photonic waveguide-based sensor chip, suitable for lab-on-a-chip applications. The photonic design and fabrication of the sensor are described, and a detailed overview of the portable measurement system is presented. In this publication, we use an integrated photonic waveguide-based absorbance sensor to run a full enzymatic assay. An assay to detect creatinine in plasma is simultaneously performed on both the photonic sensor on the portable setup and on a commercial microplate reader for a clinically relevant creatinine concentration range. We observed a high correlation between the measured waveguide propagation loss and the optical density measurement from the plate reader and measured a limit-of-detection of 4.5 µM creatinine in the sensor well, covering the relevant clinical range for creatinine detection.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Corrida , Creatinina , Desenho de Equipamento , Óptica e Fotônica
6.
Am J Transplant ; 23(6): 744-758, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36966905

RESUMO

Kidney transplant recipients (KTRs) show poorer response to SARS-CoV-2 mRNA vaccination, yet response patterns and mechanistic drivers following third doses are ill-defined. We administered third monovalent mRNA vaccines to n = 81 KTRs with negative or low-titer anti-receptor binding domain (RBD) antibody (n = 39 anti-RBDNEG; n = 42 anti-RBDLO), compared with healthy controls (HCs, n = 19), measuring anti-RBD, Omicron neutralization, spike-specific CD8+%, and SARS-CoV-2-reactive T cell receptor (TCR) repertoires. By day 30, 44% anti-RBDNEG remained seronegative; 5% KTRs developed BA.5 neutralization (vs 68% HCs, P < .001). Day 30 spike-specific CD8+% was negative in 91% KTRs (vs 20% HCs; P = .07), without correlation to anti-RBD (rs = 0.17). Day 30 SARS-CoV-2-reactive TCR repertoires were detected in 52% KTRs vs 74% HCs (P = .11). Spike-specific CD4+ TCR expansion was similar between KTRs and HCs, yet KTR CD8+ TCR depth was 7.6-fold lower (P = .001). Global negative response was seen in 7% KTRs, associated with high-dose MMF (P = .037); 44% showed global positive response. Of the KTRs, 16% experienced breakthrough infections, with 2 hospitalizations; prebreakthrough variant neutralization was poor. Absent neutralizing and CD8+ responses in KTRs indicate vulnerability to COVID-19 despite 3-dose mRNA vaccination. Lack of neutralization despite CD4+ expansion suggests B cell dysfunction and/or ineffective T cell help. Development of more effective KTR vaccine strategies is critical. (NCT04969263).


Assuntos
COVID-19 , Transplante de Rim , Humanos , SARS-CoV-2/genética , COVID-19/epidemiologia , COVID-19/prevenção & controle , Transplante de Rim/efeitos adversos , RNA Mensageiro/genética , Transplantados , Vacinas de mRNA , Receptores de Antígenos de Linfócitos T , Anticorpos Antivirais
7.
Am J Transplant ; 23(3): 423-428, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36906295

RESUMO

Neutralizing antibody (nAb) responses are attenuated in solid organ transplant recipients (SOTRs) despite severe acute respiratory syndrome-coronavirus-2 vaccination. Preexposure prophylaxis (PrEP) with the antibody combination tixagevimab and cilgavimab (T+C) might augment immunoprotection, yet in vitro activity and durability against Omicron sublineages BA.4/5 in fully vaccinated SOTRs have not been delineated. Vaccinated SOTRs, who received 300 + 300 mg T+C (ie, full dose), within a prospective observational cohort submitted pre and postinjection samples between January 31, 2022, and July 6, 2022. The peak live virus nAb was measured against Omicron sublineages (BA.1, BA.2, BA.2.12.1, and BA.4), and surrogate neutralization (percent inhibition of angiotensin-converting enzyme 2 receptor binding to full length spike, validated vs live virus) was measured out to 3 months against sublineages, including BA.4/5. With live virus testing, the proportion of SOTRs with any nAb increased against BA.2 (47%-100%; P < .01), BA.2.12.1 (27%-80%; P < .01), and BA.4 (27%-93%; P < .01), but not against BA.1 (40%-33%; P = .6). The proportion of SOTRs with surrogate neutralizing inhibition against BA.5, however, fell to 15% by 3 months. Two participants developed mild severe acute respiratory syndrome-coronavirus-2 infection during follow-up. The majority of fully vaccinated SOTRs receiving T+C PrEP achieved BA.4/5 neutralization, yet nAb activity commonly waned by 3 months postinjection. It is critical to assess the optimal dose and interval of T+C PrEP to maximize protection in a changing variant climate.


Assuntos
COVID-19 , Transplantados , Humanos , Anticorpos Monoclonais , Anticorpos Neutralizantes , Anticorpos Antivirais
8.
mSphere ; 8(1): e0052222, 2023 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36656002

RESUMO

Industrial livestock operations (ILOs), particularly processing facilities, emerged as centers of coronavirus disease 2019 (COVID-19) outbreaks in spring 2020. Confirmed cases of COVID-19 underestimate true prevalence. To investigate the prevalence of antibodies against SARS-CoV-2, we enrolled 279 participants in North Carolina from February 2021 to July 2022: 90 from households with at least one ILO worker (ILO), 97 from high-ILO intensity areas (ILO neighbors [ILON]), and 92 from metropolitan areas (metro). More metro (55.4%) compared to ILO (51.6%) and ILON participants (48.4%) completed the COVID-19 primary vaccination series; the median completion date was more than 4 months later for ILO compared to ILON and metro participants, although neither difference was statistically significant. Participants provided a saliva swab we analyzed for SARS-CoV-2 IgG using a multiplex immunoassay. The prevalence of infection-induced IgG (positive for nucleocapsid and receptor binding domain) was higher among ILO (63%) than ILON (42.9%) and metro (48.7%) participants (prevalence ratio [PR], 1.38; 95% confidence interval [CI], 1.06 to 1.80; reference category ILON and metro combined). The prevalence of infection-induced IgG was also higher among ILO participants than among an Atlanta health care worker cohort (PR, 2.45; 95% CI, 1.80 to 3.33) and a general population cohort in North Carolina (PRs, 6.37 to 10.67). The infection-induced IgG prevalence increased over the study period. Participants reporting not masking in public in the past 2 weeks had higher infection-induced IgG prevalence (78.6%) than participants reporting masking (49.3%) (PR, 1.59; 95% CI, 1.19 to 2.13). Lower education, more people per bedroom, Hispanic/Latino ethnicity, and more contact with people outside the home were also associated with higher infection-induced IgG prevalence. IMPORTANCE Few studies have measured COVID-19 seroprevalence in North Carolina, especially among rural, Black, and Hispanic/Latino communities that have been heavily affected. Antibody results show high rates of COVID-19 among industrial livestock operation workers and their household members. Antibody results add to evidence of health disparities related to COVID-19 by socioeconomic status and ethnicity. Associations between masking and physical distancing with antibody results also add to evidence of the effectiveness of these prevention strategies. Delays in the timing of receipt of COVID-19 vaccination reinforce the importance of dismantling vaccination barriers, especially for industrial livestock operation workers and their household members.


Assuntos
COVID-19 , Animais , Humanos , COVID-19/epidemiologia , SARS-CoV-2 , Gado , Prevalência , North Carolina/epidemiologia , Estudos Soroepidemiológicos , Vacinas contra COVID-19 , Anticorpos Antivirais , Imunoglobulina G
10.
Nat Rev Methods Primers ; 2(1): 96, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36532107

RESUMO

Mass spectrometry is a powerful analytical tool used for the analysis of a wide range of substances and matrices; it is increasingly utilized for clinical applications in laboratory medicine. This Primer includes an overview of basic mass spectrometry concepts, focusing primarily on tandem mass spectrometry. We discuss experimental considerations and quality management, and provide an overview of some key applications in the clinic. Lastly, the Primer discusses significant challenges for implementation of mass spectrometry in clinical laboratories and provides an outlook of where there are emerging clinical applications for this technology.

11.
Open Forum Infect Dis ; 9(11): ofac576, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36447611

RESUMO

Background: Antiretroviral therapy (ART) reduces human immunodeficiency virus (HIV) transmission risk. The primary aim of this study was to evaluate ART uptake in a trial in Zambia and South Africa that implemented a community-wide universal testing and treatment package to reduce HIV incidence. Methods: Study communities were randomized to 3 arms: A, combination-prevention intervention with universal ART; B, combination-prevention intervention with ART according to local guidelines; and C, standard of care. Samples were collected from people with HIV (PWH) during a survey visit conducted 2 years after study implementation: these samples were tested for 22 antiretroviral (ARV) drugs. Antiretroviral therapy uptake was defined as detection of ≥1 ARV drug. Resistance was evaluated in 612 randomly selected viremic participants. A 2-stage, cluster-based approach was used to assess the impact of the study intervention on ART uptake. Results: Antiretroviral drugs were detected in 4419 of 6207 (71%) samples (Arm A, 73%; Arm B, 70%; Arm C, 60%); 4140 (94%) of samples with ARV drugs had viral loads <400 copies/mL. Drug resistance was observed in 237 of 612 (39%) viremic participants (95 of 102 [93%] with ARV drugs; 142 of 510 [28%] without drugs). Antiretroviral therapy uptake was associated with older age, female sex, enrollment year, seroconverter status, and self-reported ART (all P < .001). The adjusted risk ratio for ART uptake was similar for Arm A versus C (1.21; 95% confidence interval [CI], .94-1.54; P = .12) and Arm B versus C (1.14; 95% CI, .89-1.46; P = .26). Conclusions: At the 2-year survey, 71% of PWH were on ART and 94% of those participants were virally suppressed. Universal testing and treatment was not significantly associated with increased ART uptake in this cohort.

12.
Drug Alcohol Depend ; 240: 109610, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36115223

RESUMO

BACKGROUND: Drug overdose deaths remain the primary cause of unintentional injuries in the United States. We examined the validity of a fentanyl test strip (FTS) in detecting fentanyl and its related analogs in water-based illicit drug solutions. METHODS: Illicit drugs obtained from law enforcement (N = 343) were tested using a lateral flow chromatographic immunoassay FTS (BTNX Rapid Response) and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) at a clinical chemistry laboratory in Baltimore, Maryland. RESULTS: The FTS assay detected fentanyl at 200 ng/ml in water, and 13 additional fentanyl analogs, but failed to detect carfentanil and furanyl fentanyl at or below 1000 ng/ml. Overall sensitivity and specificity for detecting fentanyls was 98.5 % and 89.2 %; and the false negative and positive rate was 1.5 % and 10.9 %. False negatives (n = 2) occurred in fentanyl and a fentanyl precursor. False positives (n = 23) occurred in the presence of other illicit drugs and compounds (56.5 %) or when fentanyls were present below 40 ng/ml (43.5 %). False positive/negative rates remained low when testing cocaine and prescription opioid (PO) samples. CONCLUSIONS: FTS is a valid drug checking tool, however, rapid immunoassays and other drug checking instruments that can detect a wider range of fentanyl analogs including carfentanil need to be prioritized to minimize accidental exposure to the full spectrum of fentanyls.


Assuntos
Cocaína , Overdose de Drogas , Drogas Ilícitas , Humanos , Estados Unidos , Analgésicos Opioides/análise , Cromatografia Líquida , Espectrometria de Massas em Tandem , Fentanila/análise , Overdose de Drogas/diagnóstico , Imunoensaio/métodos , Água/análise , Detecção do Abuso de Substâncias/métodos
13.
medRxiv ; 2022 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-35665017

RESUMO

Neutralizing antibody responses are attenuated in many solid organ transplant recipients (SOTRs) despite SARS-CoV-2 vaccination. Pre-exposure prophylaxis (PrEP) with the monoclonal antibody combination Tixagevimab and Cilgavimab (T+C) might augment immunoprotection, yet activity against Omicron sublineages in vaccinated SOTRs is unknown. Vaccinated SOTRs who received 300+300mg T+C (either single dose or two 150+150mg doses) within a prospective observational cohort submitted pre- and post-injection samples between 1/10/2022-4/4/2022. Binding antibody (anti-receptor binding domain [RBD], Roche) and surrogate neutralization (%ACE2 inhibition; ≥20% connoting neutralizing inhibition, Meso Scale Discovery) were measured against variants including Omicron sublineages BA.1 and BA.2. Data were analyzed using the Wilcoxon matched-pairs signed-rank test and McNemar's test. Among 61 participants, median (IQR) anti-RBD increased from 424 (IQR <0.8-2322.5) to 3394.5 (IQR 1403.9-7002.5) U/ml post T+C (p<0.001). The proportion demonstrating vaccine strain neutralizing inhibition increased from 46% to 100% post-T+C (p<0.001). BA.1 neutralization was low and did not increase (8% to 16% of participants post-T+C, p=0.06). In contrast, BA.2 neutralization increased from 7% to 72% of participants post-T+C (p<0.001). T+C increased anti-RBD levels, yet BA.1 neutralizing activity was minimal. Encouragingly, BA.2 neutralization was augmented and in the current variant climate T+C PrEP may serve as a useful complement to vaccination in high-risk SOTRs.

14.
Am J Transplant ; 22(9): 2254-2260, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35429211

RESUMO

Heterologous vaccination ("mixing platforms") for the third (D3) dose of SARS-CoV-2 vaccine is a potential strategy to improve antibody responses in solid organ transplant recipients (SOTRs), but data are mixed regarding potential differential immunogenicity. We assessed for differences in immunogenicity and tolerability of homologous (BNT162b2 or mRNA-1273; D3-mRNA) versus heterologous (Ad.26.COV2.S; D3-JJ) D3 among 377 SARS-CoV-2-infection naïve SOTRs who remained seronegative after two mRNA vaccines. We measured anti-spike titers and used weighted Poisson regression to evaluate seroconversion and development of high-titers, comparing D3-JJ to D3-mRNA, at 1-, 3-, and 6 month post-D3. 1-month post-D3, seroconversion (63% vs. 52%, p = .3) and development of high-titers (29% vs. 25%, p = .7) were comparable between D3-JJ and D3-mRNA recipients. 3 month post-D3, D3-JJ recipients were 1.4-fold more likely to seroconvert (80% vs. 57%, weighted incidence-rate-ratio: wIRR = 1.10 1.401.77 , p = .006) but not more likely to develop high-titers (27% vs. 22%, wIRR = 0.44 0.921.93 , p = .8). 6 month post-D3, D3-JJ recipients were 1.41-fold more likely to seroconvert (88% vs. 59%, wIRR = 1.04 1.411.93 , p = .029) and 2.63-fold more likely to develop high-titers (59% vs. 21%, wIRR = 1.38 2.635.00 , p = .003). There was no differential signal in alloimmune events or reactogenicity between platforms. SOTRs without antibody response after two mRNA vaccines may derive benefit from heterologous Ad.26.COV2.S D3.


Assuntos
Vacina de mRNA-1273 contra 2019-nCoV , Vacina BNT162 , COVID-19 , Vacinas contra Influenza , Transplante de Órgãos , Vacina de mRNA-1273 contra 2019-nCoV/efeitos adversos , Anticorpos Antivirais , Vacina BNT162/efeitos adversos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Humanos , Transplante de Órgãos/efeitos adversos , RNA Mensageiro/genética , SARS-CoV-2 , Transplantados , Vacinação
15.
JCI Insight ; 7(9)2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35349483

RESUMO

BackgroundSome clinical features of severe COVID-19 represent blood vessel damage induced by activation of host immune responses initiated by the coronavirus SARS-CoV-2. We hypothesized autoantibodies against angiotensin-converting enzyme 2 (ACE2), the SARS-CoV-2 receptor expressed on vascular endothelium, are generated during COVID-19 and are of mechanistic importance.MethodsIn an opportunity sample of 118 COVID-19 inpatients, autoantibodies recognizing ACE2 were detected by ELISA. Binding properties of anti-ACE2 IgM were analyzed via biolayer interferometry. Effects of anti-ACE2 IgM on complement activation and endothelial function were demonstrated in a tissue-engineered pulmonary microvessel model.ResultsAnti-ACE2 IgM (not IgG) autoantibodies were associated with severe COVID-19 and found in 18/66 (27.2%) patients with severe disease compared with 2/52 (3.8%) of patients with moderate disease (OR 9.38, 95% CI 2.38-42.0; P = 0.0009). Anti-ACE2 IgM autoantibodies were rare (2/50) in non-COVID-19 ventilated patients with acute respiratory distress syndrome. Unexpectedly, ACE2-reactive IgM autoantibodies in COVID-19 did not undergo class-switching to IgG and had apparent KD values of 5.6-21.7 nM, indicating they are T cell independent. Anti-ACE2 IgMs activated complement and initiated complement-binding and functional changes in endothelial cells in microvessels, suggesting they contribute to the angiocentric pathology of COVID-19.ConclusionWe identify anti-ACE2 IgM as a mechanism-based biomarker strongly associated with severe clinical outcomes in SARS-CoV-2 infection, which has therapeutic implications.FUNDINGBill & Melinda Gates Foundation, Gates Philanthropy Partners, Donald B. and Dorothy L. Stabler Foundation, and Jerome L. Greene Foundation; NIH R01 AR073208, R01 AR069569, Institutional Research and Academic Career Development Award (5K12GM123914-03), National Heart, Lung, and Blood Institute R21HL145216, and Division of Intramural Research, National Institute of Allergy and Infectious Diseases; National Science Foundation Graduate Research Fellowship (DGE1746891).


Assuntos
Enzima de Conversão de Angiotensina 2 , COVID-19 , Autoanticorpos , Células Endoteliais , Humanos , Imunoglobulina M , SARS-CoV-2
16.
Biosens Bioelectron ; 195: 113656, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34600203

RESUMO

Serological tests play an important role in the fight against Coronavirus Disease 2019 (COVID-19), including monitoring the dynamic immune response after vaccination, identifying past infection and determining community infection rate. Conventional methods for serological testing, such as enzyme-linked immunosorbent assays and chemiluminescence immunoassays, provide reliable and sensitive antibody detection but require sophisticated laboratory infrastructure and/or lengthy assay time. Conversely, lateral flow immunoassays are suitable for rapid point-of-care tests but have limited sensitivity. Here, we describe the development of a rapid and sensitive magnetofluidic immuno-PCR platform that can address the current gap in point-of-care serological testing for COVID-19. Our magnetofluidic immuno-PCR platform automates a magnetic bead-based, single-binding, and one-wash immuno-PCR assay in a palm-sized magnetofluidic device and delivers results in ∼30 min. In the device, a programmable magnetic arm attracts and transports magnetically-captured antibodies through assay reagents pre-loaded in a companion plastic cartridge, and a miniaturized thermocycler and a fluorescence detector perform immuno-PCR to detect the antibodies. We evaluated our magnetofluidic immuno-PCR with 108 clinical serum/plasma samples and achieved 93.8% (45/48) sensitivity and 98.3% (59/60) specificity, demonstrating its potential as a rapid and sensitive point-of-care serological test for COVID-19.


Assuntos
Técnicas Biossensoriais , COVID-19 , Anticorpos Antivirais , Teste Sorológico para COVID-19 , Teste para COVID-19 , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , SARS-CoV-2 , Sensibilidade e Especificidade
17.
Clin Infect Dis ; 74(11): 2010-2019, 2022 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-34453519

RESUMO

BACKGROUND: Organ transplantation from donors with human immunodeficiency virus (HIV) to recipients with HIV (HIV D+/R+) presents risks of donor-derived infections. Understanding clinical, immunologic, and virologic characteristics of HIV-positive donors is critical for safety. METHODS: We performed a prospective study of donors with HIV-positive and HIV false-positive (FP) test results within the HIV Organ Policy Equity (HOPE) Act in Action studies of HIV D+/R+ transplantation (ClinicalTrials.gov NCT02602262, NCT03500315, and NCT03734393). We compared clinical characteristics in HIV-positive versus FP donors. We measured CD4 T cells, HIV viral load (VL), drug resistance mutations (DRMs), coreceptor tropism, and serum antiretroviral therapy (ART) detection, using mass spectrometry in HIV-positive donors. RESULTS: Between March 2016 and March 2020, 92 donors (58 HIV positive, 34 FP), representing 98.9% of all US HOPE donors during this period, donated 177 organs (131 kidneys and 46 livers). Each year the number of donors increased. The prevalence of hepatitis B (16% vs 0%), syphilis (16% vs 0%), and cytomegalovirus (CMV; 91% vs 58%) was higher in HIV-positive versus FP donors; the prevalences of hepatitis C viremia were similar (2% vs 6%). Most HIV-positive donors (71%) had a known HIV diagnosis, of whom 90% were prescribed ART and 68% had a VL <400 copies/mL. The median CD4 T-cell count (interquartile range) was 194/µL (77-331/µL), and the median CD4 T-cell percentage was 27.0% (16.8%-36.1%). Major HIV DRMs were detected in 42%, including nonnucleoside reverse-transcriptase inhibitors (33%), integrase strand transfer inhibitors (4%), and multiclass (13%). Serum ART was detected in 46% and matched ART by history. CONCLUSION: The use of HIV-positive donor organs is increasing. HIV DRMs are common, yet resistance that would compromise integrase strand transfer inhibitor-based regimens is rare, which is reassuring regarding safety.


Assuntos
Infecções por HIV , Soropositividade para HIV , Antirretrovirais/uso terapêutico , HIV , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Soropositividade para HIV/tratamento farmacológico , Humanos , Integrases , Estudos Prospectivos , Doadores de Tecidos , Estados Unidos/epidemiologia , Carga Viral
18.
Eur J Cancer ; 157: 428-440, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34597977

RESUMO

Although therapeutic drug monitoring (TDM) is an important tool in guiding drug dosing for other areas of medicine including infectious diseases, cardiology, psychiatry and transplant medicine, it has not gained wide acceptance in oncology. For imatinib and other tyrosine kinase inhibitors, a flat dosing approach is utilised for management of oral chemotherapy. There are many published studies examining the correlation of blood concentrations with clinical effects of imatinib. The International Association of Therapeutic Drug Monitoring and Clinical Toxicology (IATDMCT) determined that there was a need to examine the published literature regarding utility of TDM in imatinib therapy and to develop consensus guidelines for TDM based on the available data. This article summarises the scientific evidence regarding TDM of imatinib, as well as the consensus guidelines developed by the IATDMCT.


Assuntos
Monitoramento de Medicamentos/normas , Mesilato de Imatinib/efeitos adversos , Neoplasias/tratamento farmacológico , Guias de Prática Clínica como Assunto , Inibidores de Proteínas Quinases/efeitos adversos , Consenso , Relação Dose-Resposta a Droga , Humanos , Mesilato de Imatinib/administração & dosagem , Oncologia/normas , Inibidores de Proteínas Quinases/administração & dosagem , Toxicologia/normas , Instituições Filantrópicas de Saúde/normas
19.
J Appl Lab Med ; 6(6): 1541-1550, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34329438

RESUMO

BACKGROUND: Atypical antipsychotic drugs are frequently used in the treatment of serious mental illness (SMI), specifically schizophrenia and bipolar disorder. Adherence to these prescribed drug regimens is a challenge to successful treatment with these drugs. For some of the more common drugs in this class, novel turbidimetric immunoassays have been developed for therapeutic drug monitoring (TDM) to aid in the management of patients prescribed these drugs. METHODS: Immunoassays for aripiprazole, clozapine, olanzapine, paliperidone, quetiapine, and risperidone were set up at 2 centers: Johns Hopkins Hospital (JHH) on the Roche Cobas® c501, and the Hospital of the University of Pennsylvania (HUP) on the Beckman AU480. Assay imprecision, limit of quantification (LOQ), functional sensitivity, linearity, and recovery were assessed. Remnant clinical samples were obtained from a reference laboratory (ARUP), and immunoassay results were compared with those obtained by LC-MS/MS. RESULTS: Imprecision at both sites for all analytes and concentrations tested was <10%. The manufacturer's LOQ was confirmed for each assay, and the functional sensitivity for each assay was found to be lower than the LOQ. All assays were found to be linear over the measuring range, with recoveries ranging from 91% to 123%. For method comparison, Deming regression slopes were found to be between 0.84 to 1.28. CONCLUSION: The immunoassays evaluated here are suitable for quantifying drug concentrations to be used in TDM for all 6 drugs. Commercialization of these assays will enable increased access for TDM in psychiatric patient management.


Assuntos
Antipsicóticos , Clozapina , Antipsicóticos/uso terapêutico , Cromatografia Líquida , Humanos , Imunoensaio , Espectrometria de Massas em Tandem
20.
J Chromatogr A ; 1649: 462240, 2021 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-34034105

RESUMO

Many drugs bind to serum transport proteins, which can affect both drug distribution and activity in the body. α1-Acid glycoprotein (AGP) is a key transport protein for basic and neutral drugs. Both elevated levels and altered glycosylation patterns of AGP have been seen in clinical conditions such as systemic lupus erythematosus (SLE). This study developed, optimized, and used the method of ultrafast affinity extraction (UAE) to examine whether these changes in AGP are associated with changes in the binding by some drugs to this transport protein. This approach used affinity microcolumns to capture and measure, in serum, the free fractions of several drugs known to bind AGP. These measurements were made with pooled normal control serum and serum samples from individuals with SLE. Immunoaffinity chromatography was used to obtain the content of AGP and HSA in these samples, and CE was used to examine the glycoform pattern for AGP in each serum sample. The free drug fractions measured for normal control serum ranged from 3.5 to 29.1%, in agreement with the results of ultrafiltration, and provided binding constants of ~105-106 M-1 for the given drugs with AGP at 37°C. Analysis of a screening set of SLE serum samples by UAE gave decreased free fractions (relative change, 12-55%) vs normal serum when spiked with the same types and amounts of drugs. These changes were related in some cases to AGP content, with some SLE samples having AGP levels 1.3- to 2.1-fold above the upper end of the normal range. In other cases, the changes in free fractions appeared to be linked to alterations in the glycoforms and binding constants of AGP, with some affinities differing by 1.2- to 1.5-fold vs normal AGP. This approach can be employed with other solute-protein systems and to investigate binding by other drugs or transport proteins directly in clinical samples.


Assuntos
Proteínas Sanguíneas/metabolismo , Orosomucoide/metabolismo , Preparações Farmacêuticas/sangue , Cromatografia de Afinidade/métodos , Glicosilação , Humanos , Lúpus Eritematoso Sistêmico/sangue , Ligação Proteica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...