Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Eur Radiol ; 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38041717

RESUMO

OBJECTIVES: To compare the results of CT- vs MR-guided radiofrequency ablation (RFA) of liver metastases (LM) from colorectal cancer after 10 years of follow-up in an observational, retrospective, and multicentric study. METHODS: A total of 238 patients with 496 LM were treated with RFA either with CT (CT group) or magnetic resonance (MR group) guidance. Every ablated LM was assessed and followed up with diagnostic MRI. Technical success, technique efficacy, predictive factors, recurrence rates, and overall survival were assessed. RESULTS: The CT group comprised 143 patients and the MR group 77 patients. Eighteen patients underwent ablation with both modalities. Technical success per patient and per lesion was 88% and 93% for CT and 87% and 89.6% for MR, and technique efficacy was 97.1% and 98.6% for CT and 98.7% and 99.3% for MR respectively. Local recurrence following the first ablation (primary patency) occurred in 20.1% (CT) vs 4.6% (MR) (p < 0.001). Residual liver tumor, size of LM, and advanced N and M stage at initial diagnosis were independent predictors for overall survival in both groups. The median overall survival measured from first RFA treatment was 2.6 years. The 1-year, 5-year, and 10-year survival were 85.9%, 25.5%, and 19.1% respectively. CONCLUSIONS: The MR group had significantly better local control compared to the CT group. There was no significant difference in patient survival between the two groups. CLINICAL RELEVANCE STATEMENT: MR-guided radiofrequency ablation of colorectal liver metastases is safe and effective, and offers better local control than CT-guided ablation. KEY POINTS: • Imaging modality for radiofrequency ablation guidance is an independent predictor of local recurrence in colorectal liver metastases. • MR-guided radiofrequency ablation achieved better local control of liver metastases from colorectal cancer than CT-guided. • The number and size of liver metastases are, among others, independent predictors of survival. Radiofrequency ablation with MR guidance improved clinical outcome but does not affect survival.

2.
Pneumologie ; 76(9): 629-632, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35504298

RESUMO

In this paper, we present a case of SARS-CoV2-Virus a non-vaccinated 54-year-old male admitted with COVID-19 pneumonia and respiratory insufficiency requiring high-flow oxygen supplementation. CT-scan of the lung revealed multifocal bilateral ground-glass opacities and - as a rare complication - a large pneumatocele in the middle of the posterior part of the left lower lobe. In order to treat the pneumatocele, a 10 F was placed into the cavity. The resulting pneumothorax was successfully treated with a 20 F chest tube over a 9-day period. The pneumatocele shrank only slightly. This case demonstrates a unique radiologic finding in COVID-19, which is likely the result of severe inflammation secondary to SARS-CoV-2 including an unfruitful attempt at depressurisation.


Assuntos
COVID-19 , COVID-19/complicações , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , RNA Viral , SARS-CoV-2 , Tomografia Computadorizada por Raios X/métodos
3.
Insights Imaging ; 13(1): 48, 2022 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-35312842

RESUMO

BACKGROUND: Radiofrequency ablation (RFA) is a minimal-invasive, local therapy in patients with circumscribed metastatic disease. Although widely used, long time survival analysis of treated liver metastases is still pending while also analysing the patients' experience of MR-based radiofrequency. METHODS: Monocentric, retrospective analysis of long-time overall and progression free survival (OS; PFS) of 109 patients, treated with MRI-guided hepatic RFA between 1997 and 2010, focusing on colorectal cancer patients (CRC). Complimentary therapies were evaluated and Kaplan Meier-curves were calculated. Patients' experience of RFA was retrospectively assessed in 28 patients. RESULTS: 1-, 3-, 5-, 10-year OS rates of 109 patients with different tumour entities were 83.4%, 53.4%, 31.0% and 22.9%, median 39.2 months, with decreasing survival rates for larger metastases size. For 72 CRC patients 1-, 3-, 5-, 10-year OS rates of 90.2%, 57.1%, 36.1% and 26.5% were documented (median 39.5 months). Thereof, beneficial outcome was detected for patients with prior surgery of the CRC including chemotherapy (median 53.0 months), and for liver metastases up to 19 mm (28.5% after 145 months). Hepatic PFS was significantly higher in patients with liver lesions up to 29 mm compared to larger ones (p = 0.035). 15/28 patients remembered RFA less incriminatory than other applied therapies. CONCLUSIONS: This is the first single-centre, long-time OS and PFS analysis of MRI-guided hepatic RFA of liver metastases from different tumour entities, serving as basis for further comparison studies. Patients' experience of MR based RFA should be analysed simultaneously to the performed RFA in the future.

4.
Per Med ; 19(2): 103-112, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34984920

RESUMO

Purpose: Willingness-to-pay (WTP) analyses can support allocation processes considering the patients preferences in personalized medicine. However, genetic testing especially might imply ethical concerns that have to be considered. Methods: A WTP questionnaire was designed to compare preferences for imaging and genetic testing in cancer patients and to evaluate potential ethical concerns. Results: Comparing the options of imaging and genetics showed comparable WTP values. Ethical concerns about genetic testing seemed to be minor. Treatment success was the top priority irrespective of the diagnostic modality. In general, the majority of patients considered personalized medicine to be beneficial. Conclusion: Most patients valued personalized approaches and rated the benefits of precision medicine of overriding importance irrespective of modality or ethical concerns.


A study of the patients preferences in diagnostic approaches where patients were asked if they would hypothetically pay out-of-pocket money for particular procedures. However, in regard to personalized medicine (specifically selected for a single person) genetic testing especially might imply ethical concerns. A questionnaire was designed to compare preferences for imaging and genetic testing in cancer patients and to evaluate potential ethical concerns. Comparing the options of imaging and genetics showed comparable values of out-of-pocket money the patients were willing to pay. Ethical concerns about genetic testing were minor. Treatment success was the top priority irrespective of the diagnostic modality. Most patients valued personalized approaches and rated the benefits of overriding importance irrespective of modality or ethical concerns.


Assuntos
Neoplasias , Medicina de Precisão , Testes Genéticos/métodos , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/genética , Inquéritos e Questionários
5.
Rofo ; 193(5): 513-520, 2021 May.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-33327030

RESUMO

Due to its excellent intrinsic soft tissue contrast, magnetic resonance imaging allows excellent visualization and anatomical separation of therapy-relevant risk structures such as the mesorectal fascia, local lymph nodes, and vascular structures in patients with rectal carcinoma. This makes magnetic resonance imaging (MRI) a valuable evaluation method for further therapeutic stratification. In particular, MRI is indispensable for the decision to refrain from neoadjuvant therapy and to choose a primary surgical approach. In addition to the oncologically generally relevant T-, N-, and M-criteria, two further parameters are included: the extramural vascular infiltration and the circumferential resection margin. Due to the significant impact of MRI on further therapeutic decision-making, standardized MR image quality is considered essential. KEY POINTS:: · Magnetic resonance imaging is a valuable evaluation method for further therapeutic stratification.. · Critical anatomic landmarks for evaluation are circumferential resection margins.. CITATION FORMAT: · Attenberger UI, Clasen S, Ghadimi M et al. Importance and Qualitative Requirements of Magnetic Resonance Imaging for Therapy Planning in Rectal Cancer - Interdisciplinary Recommendations of AIO, ARO, ACO and the German Radiological Society. Fortschr Röntgenstr 2021; 193: 513 - 520.


Assuntos
Imageamento por Ressonância Magnética , Radiologia , Neoplasias Retais , Consenso , Humanos , Terapia Neoadjuvante , Radiologia/métodos , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia , Neoplasias Retais/terapia
6.
Cardiovasc Intervent Radiol ; 43(11): 1631-1638, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32699978

RESUMO

PURPOSE: Evaluation of technique effectiveness, patient safety and ablation parameters of MR-guided microwave ablation in hepatic malignancies using an MR-conditional high-power microwave ablation system. MATERIALS AND METHODS: Institutional review board approval and informed patient consent were obtained. Patients who underwent MR-guided microwave ablation of hepatic malignancies in a 1.5T wide-bore scanner using a perfusion-cooled high-power microwave ablation system with a maximum generator power of 150 W were included. Ablation parameters comprising procedure durations, net ablation duration, applicator positions and ablation zone dimensions were recorded. Adverse events were classified according to the CIRSE classification system. Technique effectiveness was assessed after 1 month. Follow-up was conducted with contrast-enhanced MRI and ranged from 1 to 20 months (mean: 6.1 ± 5.4 months). RESULTS: Twenty-one consecutive patients (age: 63.4 ± 10.5 years; 5 female) underwent 22 procedures for 28 tumours (9 hepatocellular carcinomas, 19 metastases) with a mean tumour diameter of 14.6 ± 5.4 mm (range: 6-24 mm). Technique effectiveness was achieved in all lesions. Tumours were treated using 1.7 ± 0.7 applicator positions (range: 1-3). Mean energy and ablation duration per tumour were 75.3 ± 35.4 kJ and 13.3 ± 6.2 min, respectively. Coagulation zone short- and long-axis diameters were 29.1 ± 6.4 mm and 39.9 ± 7.4 mm, respectively. Average procedure duration was 146.4 ± 26.2 min (range: 98-187 min). One minor complication was reported. Five patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed during initial follow-up. CONCLUSION: MR-guided high-power microwave ablation provides safe and effective treatment of hepatic malignancies with short ablation times and within acceptable procedure durations.


Assuntos
Técnicas de Ablação/métodos , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética/métodos , Micro-Ondas/uso terapêutico , Terapia Assistida por Computador/métodos , Adulto , Idoso , Carcinoma Hepatocelular/diagnóstico , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Segurança do Paciente , Resultado do Tratamento
7.
Cancer Imaging ; 20(1): 37, 2020 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-32460898

RESUMO

BACKGROUND: Combination therapy using hepatic resection (HR) and intra-operative thermal ablation is a treatment approach for patients with technically unresectable liver malignancies. The aim of this study was to investigate safety, survival and local recurrence rates for patients with technically unresectable liver tumors undergoing HR and separate percutaneous MR-guided thermoablation procedure as an alternative approach. METHODS: Data from all patients with primary or secondary hepatic malignancies treated at a single institution between 2004 and 2018 with combined HR and MR-guided percutaneous thermoablation was collected and retrospectively analyzed. Complications, procedure related information and patient characteristics were collected from institutional records. Overall survival and disease-free survival were estimated using the Kaplan-Meier method. RESULTS: A total of 31 patients (age: 62.8 ± 9.1 years; 10 female) with hepatocellular carcinoma (HCC; n = 7) or hepatic metastases (n = 24) were treated for 98 hepatic tumors. Fifty-six tumors (mean diameter 28.7 ± 23.0 mm) were resected. Forty-two tumors (15.1 ± 7.6 mm) were treated with MR-guided percutaneous ablation with a technical success rate of 100%. Local recurrence at the ablation site occurred in 7 cases (22.6%); none of these was an isolated local recurrence. Six of 17 patients (35.3%) treated for colorectal liver metastases developed local recurrence. Five patients developed recurrence at the resection site (16.1%). Non-local hepatic recurrence was observed in 18 cases (58.1%) and extrahepatic recurrence in 11 cases (35.5%) during follow-up (43.1 ± 26.4 months). Ten patients (32.3%) developed complications after HR requiring pharmacological or interventional treatment. No complication requiring therapy was observed after ablation. Median survival time was 44.0 ± 7.5 months with 1-,3-, 5-year overall survival rates of 93.5, 68.7 and 31.9%, respectively. The 1-, 3- and 5-year disease-free survival rates were 38.7, 19.4 and 9.7%, respectively. CONCLUSION: The combination of HR and MR-guided thermoablation is a safe and effective approach in the treatment of technically unresectable hepatic tumors and can achieve long-term survival.


Assuntos
Carcinoma Hepatocelular/terapia , Ablação por Cateter/métodos , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade
8.
Int J Hyperthermia ; 37(1): 349-355, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32286087

RESUMO

Purpose: To investigate technical success, technique efficacy, safety and outcome of MR-guided microwave ablation (MWA) in hepatic malignancies.Material and methods: In this prospective IRB-approved study, patients scheduled for percutaneous treatment of hepatic malignancies underwent MR-guided MWA in a closed-bore 1.5 T MR system. Technical success was assessed on post-procedural MR control imaging. Technique efficacy was evaluated 4 weeks after the procedure on multi-parametric MRI. Assessment of safety followed the Society of Interventional Radiology grading system. Kaplan-Meier survival estimates were calculated to evaluate overall survival (OS), time to local tumor progression (TLTP), and time to non-target progression (TNTP).Results: Between 2015 and 2019, 47 patients (60.5 ± 12.2 years; 39 male) underwent 50 procedures for 58 hepatic tumors (21 hepatocellular carcinomas; 37 metastases). Mean target tumor size was 16 ± 7mm (range: 6-39 mm). Technical success and technique efficacy were 100% and 98%, respectively. Lesions were treated using 2.6 applicator positions (range: 1-6). Mean energy, ablation duration per tumor, and procedure duration were 43.2 ± 23.5 kJ, 26.7 ± 13.1 min and 211.2 ± 68.7 min, respectively. 10 minor (20%) and 3 major (6%) complications were observed. Median post-interventional hospital admission was 1 day (range: 1-19 days). Median OS was 41.6 (IQR: 26.4-) months. Local recurrence occurred after 4 procedures (8%) with TLTP ranging between 3.1 and 41.9 months. Non-target recurrence was observed in 64% of patients after a median TNTP of 13.8 (IQR 2.3-) months.Conclusion: MR-guided MWA allows for safe and successful treatment of hepatic malignancies with a high technique efficacy however with relatively long procedure durations.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/métodos , Humanos , Neoplasias Hepáticas/mortalidade , Pessoa de Meia-Idade , Estudos Prospectivos , Análise de Sobrevida
9.
Front Immunol ; 10: 2526, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31803175

RESUMO

Background: Radiofrequency ablation (RFA) is an established treatment option for malignancies located in the liver. RFA-induced irreversible coagulation necrosis leads to the release of danger signals and cellular content. Hence, RFA may constitute an endogenous in situ tumor vaccination, stimulating innate and adaptive immune responses, including tumor-antigen specific T cells. This may explain a phenomenon termed abscopal effect, namely tumor regression in untreated lesions evidenced after distant thermal ablation or irradiation. In this study, we therefore assessed systemic and local immune responses in individual patients treated with RFA. Methods: For this prospective clinical trial, patients with liver metastasis from colorectal carcinoma (mCRC) receiving RFA and undergoing metachronous liver surgery for another lesion were recruited (n = 9) during a 5-year period. Tumor and non-malignant liver tissue samples from six patients were investigated by whole transcriptome sequencing and tandem-mass spectrometry, characterizing naturally presented HLA ligands. Tumor antigen-derived HLA-restricted peptides were selected by different predefined approaches. Further, candidate HLA ligands were manually curated. Peripheral blood mononuclear cells were stimulated in vitro with epitope candidate peptides, and functional T cell responses were assessed by intracellular cytokine staining. Immunohistochemical markers were additionally investigated in surgically resected mCRC from patients treated with (n = 9) or without RFA (n = 7). Results: In all six investigated patients, either induced immune responses and/or pre-existing T cell immunity against the selected targets were observed. Multi-cytokine responses were inter alia directed against known tumor antigens such as cyclin D1 but also against a (predicted) mutation contained in ERBB3. Immunohistochemistry did not show a relevant influx of immune cells into distant malignant lesions after RFA treatment (n = 9) as compared to the surgery only mCRC group (n = 7). Conclusions: Using an individualized approach for target selection, RFA induced and/or boosted T cell responses specific for individual tumor antigens were more frequently detectable as compared to previously published observations with well-characterized tumor antigens. However, the witnessed modest RFA-induced immunological effects alone may not be sufficient for the rejection of established tumors. Therefore, these findings warrant further clinical investigation including the assessment of RFA combination therapies e.g., with immune stimulatory agents, cancer vaccination, and/or immune checkpoint inhibitors.


Assuntos
Neoplasias Colorretais/imunologia , Neoplasias Colorretais/patologia , Imunidade , Neoplasias Hepáticas/imunologia , Neoplasias Hepáticas/secundário , Idoso , Ablação por Cateter/métodos , Cromatografia Líquida , Biologia Computacional , Feminino , Perfilação da Expressão Gênica , Antígenos HLA/imunologia , Antígenos HLA/metabolismo , Humanos , Imunidade/genética , Imunofenotipagem , Ligantes , Neoplasias Hepáticas/cirurgia , Masculino , Instabilidade de Microssatélites , Pessoa de Meia-Idade , Proteômica/métodos , Linfócitos T/imunologia , Linfócitos T/metabolismo , Espectrometria de Massas em Tandem , Resultado do Tratamento , Sequenciamento do Exoma
10.
Eur Radiol Exp ; 3(1): 39, 2019 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-31549338

RESUMO

BACKGROUND: We evaluated a magnetic resonance (MR)-conditional high-power microwave ablation system. METHODS: An ex vivo 1.5-T evaluation was conducted by varying the sequence (T1-weighted volume interpolated breath-hold examination, T1w-VIBE; T1-weighted fast low-angle shot, T1w-FLASH; T2-weighted turbo spin-echo, T2w-TSE), applicator angulation to B0 (A-to-B0), slice orientation, and encoding direction. Tip location error (TLE) and artefact diameters were measured, and influence of imaging parameters was assessed with analysis of variance and post hoc testing. Twenty-four ex vivo ablations were conducted in three bovine livers at 80 W and 120 W. Ablation durations were 5, 10, and 15 min. Ablation zones were compared for short-axis diameter (SAD), volume, and sphericity index (SI) with unpaired t test. RESULTS: The artefact pattern was similar for all sequences. The shaft artefact (4.4 ± 2.9 mm, mean ± standard deviation) was dependent on the sequence (p = 0.012) and the A-to-B0 (p < 0.001); the largest shaft diameter was measured with T1w-FLASH (6.3 ± 3.4 mm) and with perpendicular A-to-B0 (6.7 ± 2.4 mm). The tip artefact (1.6 ± 0.7 mm) was dependent on A-to-B0 (p = 0.001); TLE was -2.6 ± 1.0 mm. Ablation results at the maximum setting (15 min, 120 W) were SAD = 42.0 ± 1.41 mm; volume = 56.78 ± 3.08 cm3, SI = 0.68 ± 0.05. In all ablations, SI ranged 0.68-0.75 with the smallest SI at 15 min and 120 W (p = 0.048). CONCLUSION: The system produced sufficiently large ablation zones and the artefact was appropriate for MR-guided interventions.


Assuntos
Técnicas de Ablação/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Imageamento por Ressonância Magnética , Micro-Ondas , Cirurgia Assistida por Computador , Animais , Artefatos , Bovinos , Técnicas In Vitro
11.
Br J Radiol ; 92(1100): 20180835, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31124700

RESUMO

The presence of distant metastases has long been a predictor of poor outcome in solid cancer. However, in an oncologic situation called oligometastatic disease (OMD), multiple studies have revealed a survival benefit with aggressive treatment of these metastases. Besides surgery and radiation therapy, local thermal therapies have developed into a treatment option for OMD. Most studies concerning local therapy of OMD are available for colorectal cancer, which is therefore the focus of this article. Furthermore, this review gives a basic overview of the most popular ablation techniques for treatment of OMD.


Assuntos
Técnicas de Ablação , Neoplasias Colorretais/patologia , Neoplasias Hepáticas/cirurgia , Neoplasias Pulmonares/cirurgia , Melanoma/cirurgia , Humanos , Fígado/cirurgia , Neoplasias Hepáticas/secundário , Pulmão/cirurgia , Neoplasias Pulmonares/secundário , Melanoma/secundário
12.
J Magn Reson Imaging ; 49(2): 374-381, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30221797

RESUMO

BACKGROUND: Percutaneous tumor ablation is commonly performed using computed tomography (CT) or ultrasound (US) guidance, although reliable visualization of the target tumor may be challenging. MRI guidance provides more reliable visualization of target tumors and allows for real-time imaging and multiplanar capabilities, making it the modality of choice, in particular if lesions are small. PURPOSE: To investigate the feasibility, technical success, and safety of percutaneous MR-guided ablation (RFA n = 27 / MWA n = 16) of small (≤12 mm) hepatic malignancies. STUDY TYPE: Retrospective case study. POPULATION: In all, 45 patients (age: 61.1 ± 11.8) with hepatic malignancies and a lesion diameter of ≤12 mm scheduled for percutaneous MR-guided tumor ablation based on a tumor board decision were included. FIELD STRENGTH: A 1.5T MR system was used for planning, targeting, and monitoring. ASSESSMENT: Feasibility assessment included the detection of the target tumor, tumor delineation during MR-fluoroscopy guided targeting, and the number of attempts needed for precise applicator placement. Technical success was defined as successful performance of the procedure including a safety margin of 5 mm. Safety evaluation was based on procedure-related complications. STATISTICAL TEST: Frequency. RESULTS: Tumor ablation (mean diameter 9.0 ± 2.1 mm) was successfully completed in 43/45 patients. Planning imaging was conducted without a contrast agent in 79% (n = 37). In 64% (n = 30), the target tumors were visible with MR-fluoroscopy. In six patients (13%), planning imaging revealed new, unexpected small lesions, which were either treated in the same session (n = 4) or changed therapy management (n = 2) due to diffuse tumor progress. Postprocedural imaging revealed a technical success of 100% (43/43), with no major complications. During follow-up, no local tumor progression was observed (mean follow-up 24.7 ± 14.0 months) although 28% (12) patients developed new hepatic lesions distant to the ablation zone. No major complications were observed. DATA CONCLUSION: MR-guided ablation is a feasible approach for an effective and safe treatment of small hepatic malignancies. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2019;49:374-381.


Assuntos
Ablação por Cateter/métodos , Fluoroscopia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/metabolismo , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Idoso , Meios de Contraste , Progressão da Doença , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos
13.
Strahlenther Onkol ; 194(11): 985-990, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29987338

RESUMO

BACKGROUND: Nonoperative management (NOM) of rectal cancer after radiochemotherapy (RtChx) in patients with a clinical complete response is an emerging strategy with the goal to improve quality of life without compromising cure rates. However close monitoring with both magnetic resonance imaging (MRI) and rectoscopy is required for the early detection of possible local regrowths. We therefore performed a cost analysis comparing the costs of immediate surgery with the costs for MRI and rectoscopy during surveillance as in the upcoming CAO/ARO/AIO-16 trial. METHODS: MRIs and rectoscopies of patients with a clinical complete response after RtChx over the course of 5 years were simulated and compared with immediate surgery after RtChx. Transition probabilities between health stages (no evidence of disease, local regrowth and salvage surgery, distant failure) were derived from the literature. Costs for ambulatory imaging and endoscopic studies were calculated according to the "Gebührenordnung für Ärzte" (GOÄ), costs for surgery based on the diagnosis-related groups system. Three different scenarios with higher costs for salvage surgery or higher regrowth rates were simulated. RESULTS: A patient without disease recurrence will generate costs for MRI and rectoscopy of 6344 € over 5 years compared with costs of 14,511 € for immediate radical surgery. When 25% local regrowths with subsequent salvage surgery were included in the model, the average costs per patient are 8299 €. In our simulations a NOM strategy was cost-saving compared with immediate surgery in all three scenarios. CONCLUSION: A NOM strategy with an intensive surveillance using MRI and rectoscopy will produce costs that are expected to remain below those of immediate surgery.


Assuntos
Quimiorradioterapia , Neoplasias Retais , Humanos , Imageamento por Ressonância Magnética , Terapia Neoadjuvante , Neoplasias Retais/terapia , Terapia de Salvação , Conduta Expectante
15.
Minim Invasive Ther Allied Technol ; 27(1): 60-68, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29231067

RESUMO

OBJECTIVE: To evaluate artifact configuration and diameters of a magnetic resonance (MR) compatible microwave (MW) applicator using near-realtime MR-fluoroscopic sequences for percutaneous tumor ablation procedures. MATERIAL AND METHODS: Two MW applicators (14 G and 16 G) were tested in an ex-vivo phantom at 1.5 T with two 3 D fluoroscopic sequences: T1-weighted spoiled Gradient Echo (GRE) and T1/T2-weighted Steady State Free Precession (SSFP) sequence. Applicator orientation to main magnetic field (B0), slice orientation and phase encoding direction (PED) were systematically varied. The influence of these variables was assessed with ANOVA and post-hoc testing. RESULTS: The artifact was homogenous along the whole length of both antennas with all tested parameters. The tip artifact diameter of the 16 G antenna measured 6.9 ± 1.0 mm, the shaft artifact diameter 8.6 ± 1.2 mm and the Tip Location Error (TLE) was 1.5 ± 1.2 mm.The tip artifact diameter of the 14 G antenna measured 7.7 ± 1.2 mm, the shaft artifact diameter 9.6 ± 1.5 mm and TLE was 1.6 ± 1.2 mm. Orientation to B0 had no statistically significant influence on tip artifact diameters (16 G: p = .55; 14 G: p = .07) or TLE (16 G: p = .93; 14 G: p = .26). GRE sequences slightly overestimated the antenna length with TLE(16 G) = 2.6 ± 0.5 mm and TLE(14 G) = 2.7 ± 0.7 mm. CONCLUSIONS: The MR-compatible MW applicator's artifact seems adequate with an acceptable TLE for safe applicator positioning during near-realtime fluoroscopic MR-guidance.


Assuntos
Artefatos , Neoplasias Hepáticas/terapia , Micro-Ondas/uso terapêutico , Técnicas de Ablação , Ablação por Cateter , Fluoroscopia , Imageamento Tridimensional , Técnicas In Vitro , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagens de Fantasmas
16.
Eur J Radiol ; 94: 85-92, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28655432

RESUMO

OBJECTIVE: To evaluate the diagnostic accuracy of the individual sequences of a clinical routine liver MRI protocol for the detection of local tumour progression after radiofrequency (RF) ablation of hepatic malignancies. MATERIAL AND METHODS: A cohort of 93 patients treated for 140 primary and secondary hepatic malignancies with RF ablation was assembled for this retrospective study. The cohort contained 31 cases of local tumour progression, which occurred 8.3±6.2months (range: 4.0-28.2 months) after treatment. All patients underwent clinical routine follow-up MRI at 1.5T including following sequences: unenhanced T1-weighted fast low angle shot (FLASH-2D), T2-weighted turbo-spin-echo sequence, contrast-enhanced (CE) T1-weighted volume-interpolated breath-hold examination (VIBE), diffusion-weighted imaging (DWI). Follow-up was 32.7±22.5months (range: 4.0-138.3 months). Two readers independently evaluated the individual sequences separately for signs of local tumour progression. Diagnostic confidence was rated on a 4-point scale. Inter-reader agreement was assessed with Cohens kappa. Long-term follow-up and histological specimen served as standard of reference. RESULTS: Both readers reached the highest sensitivity for detection of local tumour progression with unenhanced T1-FLASH 2D (88.2% and 94.1%, respectively) and the highest specificity with CE T1-VIBE (96.2% and 97.2%, respectively). Highest inter-reader agreement was reached with T1-FLASH-2D (kappa=0.83). Typical pitfalls for false-positive diagnoses were focal cholestasis and vasculature adjacent to the ablation zone. Diagnostic confidence was highest with CE T1-VIBE for reader 1 and DWI for reader 2. CONCLUSION: Unenhanced T1-FLASH-2D is an essential sequence for follow-up imaging after tumour ablation with a high sensitivity for detection of local progression and a high inter-reader agreement.


Assuntos
Ablação por Cateter , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Suspensão da Respiração , Progressão da Doença , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
17.
Int J Hyperthermia ; 33(6): 617-623, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28110576

RESUMO

OBJECTIVE: Evaluation of a newly developed MR-compatible microwave ablation system with focus on ablation performance and comparison with a corresponding standard microwave ablation system. MATERIALS AND METHODS: A total of 52 ablations were performed with a non-cooled microwave ablation system in an ex vivo bovine liver model using the following settings: [A] 16G-standard antenna, 2 cm active tip, 2.4 m cable; [B] MR-compatible 16G-antenna, 2 cm active tip, 2.4 m cable; [C] MR-compatible 16G-antenna, 2 cm active tip, extended 6 m cable; and [D] MR-compatible 16G-antenna, 4 cm active tip, extended 6 m cable. Ablation durations were 3, 5 and 10 min, and additionally 15 min for [D]. Ablations zones were measured for short-axis diameter (SA) and long-axis diameter (LA). Settings [A]-[C] were compared regarding SA, volume (V) and generator energy output (E) with analysis of variance and Tukey-Kramer post hoc test. Ablation performance of the MR-compatible settings [C] and [D] were compared regarding SA, V, E and sphericity index (SA/LA) with unpaired t-test. p < 0.05 was considered as statistically significant. RESULTS: No significant differences were found between [A], [B] and [C] regarding SA and V (10 min; SA[A] = 25.8 ± 2.4 mm, SA[B] = 25.3 ± 1.9 mm, SA[C] = 25.0 ± 2.0 mm, p = 0.88; V[A] = 17.8 ± 4.4 cm³, V[B] = 16.6 ± 3.0 cm³, V[C] = 17.8 ± 2.7 cm³, p = 0.85); however, the highest energy output was measured for setting [C] (10 min; [A]: 9.9 ± 0.5 kJ, [B]: 10.1 ± 0.5 kJ, [C]: 13.1 ± 0.3 kJ, p < 0.001). SA, V and E were significantly larger with setting [D] than [C] with 10 min ablations (SA[C] = 25.0 ± 2.0 mm, SA[D] = 34.0 ± 2.9 mm, p = 0.003; V[C] = 17.8 ± 2.7 cm³, V[D] = 39.4 ± 7.5 cm³, p = 0.007; E[C] = 13.1 ± 0.3 kJ, E[D] = 16.7 ± 0.8 kJ, p = 0.002) without significant difference in sphericity index (SA/LA[C] = 0.46 ± 0.02, SA/LA[D] = 0.52 ± 0.04, p = 0.08). CONCLUSION: The tested MR-compatible system can be used without loss of ablation performance compared to the standard system.


Assuntos
Técnicas de Ablação , Fígado/cirurgia , Micro-Ondas , Animais , Coagulação Sanguínea , Bovinos , Imageamento por Ressonância Magnética , Modelos Animais
18.
Acta Radiol ; 58(3): 279-285, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27166346

RESUMO

Background Metal artifacts often impair diagnostic accuracy in computed tomography (CT) imaging. Therefore, effective and workflow implemented metal artifact reduction algorithms are crucial to gain higher diagnostic image quality in patients with metallic hardware. Purpose To assess the clinical performance of a novel iterative metal artifact reduction (iMAR) algorithm for CT in patients with dental fillings. Material and Methods Thirty consecutive patients scheduled for CT imaging and dental fillings were included in the analysis. All patients underwent CT imaging using a second generation dual-source CT scanner (120 kV single-energy; 100/Sn140 kV in dual-energy, 219 mAs, gantry rotation time 0.28-1/s, collimation 0.6 mm) as part of their clinical work-up. Post-processing included standard kernel (B49) and an iterative MAR algorithm. Image quality and diagnostic value were assessed qualitatively (Likert scale) and quantitatively (HU ± SD) by two reviewers independently. Results All 30 patients were included in the analysis, with equal reconstruction times for iMAR and standard reconstruction (17 s ± 0.5 vs. 19 s ± 0.5; P > 0.05). Visual image quality was significantly higher for iMAR as compared with standard reconstruction (3.8 ± 0.5 vs. 2.6 ± 0.5; P < 0.0001, respectively) and showed improved evaluation of adjacent anatomical structures. Similarly, HU-based measurements of degree of artifacts were significantly lower in the iMAR reconstructions as compared with the standard reconstruction (0.9 ± 1.6 vs. -20 ± 47; P < 0.05, respectively). Conclusion The tested iterative, raw-data based reconstruction MAR algorithm allows for a significant reduction of metal artifacts and improved evaluation of adjacent anatomical structures in the head and neck area in patients with dental hardware.


Assuntos
Artefatos , Prótese Dentária , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Metais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste , Feminino , Cabeça/diagnóstico por imagem , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem
19.
Eur Radiol ; 27(4): 1467-1476, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27553935

RESUMO

OBJECTIVES: Evaluation of the technical success, patient safety and technical effectiveness of magnetic resonance (MR)-guided microwave ablation of hepatic malignancies. METHODS: Institutional review board approval and informed patient consent were obtained. Fifteen patients (59.8 years ± 9.5) with 18 hepatic malignancies (7 hepatocellular carcinomas, 11 metastases) underwent MR-guided microwave ablation using a 1.5-T MR system. Mean tumour size was 15.4 mm ± 7.7 (7-37 mm). Technical success and ablation zone diameters were assessed by post-ablative MR imaging. Technique effectiveness was assessed after 1 month. Complications were classified according to the Common Terminology Criteria for Adverse Events (CTCAE). Mean follow-up was 5.8 months ± 2.6 (1-10 months). RESULTS: Technical success and technique effectiveness were achieved in all lesions. Lesions were treated using 2.5 ± 1.2 applicator positions. Mean energy and ablation duration per tumour were 37.6 kJ ± 21.7 (9-87 kJ) and 24.7 min ± 11.1 (7-49 min), respectively. Coagulation zone short- and long-axis diameters were 31.5 mm ± 10.5 (16-65 mm) and 52.7 mm ± 15.4 (27-94 mm), respectively. Two CTCAE-2-complications occurred (pneumothorax, pleural effusion). Seven patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed. CONCLUSIONS: Microwave ablation is feasible under near real-time MR guidance and provides effective treatment of hepatic malignancies in one session. KEY POINTS: • Planning, applicator placement and therapy monitoring are possible without using contrast enhancement • Energy transmission from the generator to the scanner room is safely possible • MR-guided microwave ablation provides effective treatment of hepatic malignancies in one session • Therapy monitoring is possible without applicator retraction from the ablation site.


Assuntos
Técnicas de Ablação/métodos , Neoplasias Hepáticas/cirurgia , Imagem por Ressonância Magnética Intervencionista/métodos , Adulto , Idoso , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...