Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
JACC Cardiovasc Interv ; 14(15): 1704-1713, 2021 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-34274294

RESUMO

OBJECTIVES: Using French transcatheter aortic valve replacement (TAVR) registries linked with the nationwide administrative databases, the study compared the rates of long-term mortality, bleeding, and ischemic events after TAVR in patients requiring oral anticoagulation with direct oral anticoagulants (DOACs) or vitamin K antagonists (VKAs). BACKGROUND: The choice of optimal drug for anticoagulation after TAVR remains debated. METHODS: Data from the France-TAVI and FRANCE-2 registries were linked to the French national health single-payer claims database, from 2010 to 2017. Propensity score matching was used to reduce treatment-selection bias. Two primary endpoints were death from any cause (efficacy) and major bleeding (safety). RESULTS: A total of 24,581 patients who underwent TAVR were included and 8,962 (36.4%) were treated with OAC. Among anticoagulated patients, 2,180 (24.3%) were on DOACs. After propensity matching, at 3 years, mortality (hazard ratio [HR]: 1.37; 95% confidence interval [CI]: 1.12-1.67; P < 0.005) and major bleeding including hemorrhagic stroke (HR: 1.64; 95% CI: 1.17-2.29; P < 0.005) were lower in patients on DOACs compared with those on VKAs. The rates of ischemic stroke (HR: 1.32; 95% CI: 0.81-2.15; P = 0.27) and acute coronary syndrome (HR: 1.17; 95% CI: 0.68-1.99; P = 0.57) did not differ among groups. CONCLUSIONS: In these large multicenter French TAVR registries with an exhaustive clinical follow-up, the long-term mortality and major bleeding were lower with DOACs than VKAs at discharge. The present study supports preferential use of DOACs rather than VKAs in patients requiring oral anticoagulation therapy after TAVR.


Assuntos
Fibrilação Atrial , Substituição da Valva Aórtica Transcateter , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Vitamina K
2.
JACC Cardiovasc Interv ; 12(5): 413-419, 2019 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-30772290

RESUMO

OBJECTIVES: This study sought to describe the procedural and clinical outcomes of patients undergoing transcarotid (TC) transcatheter aortic valve replacement (TAVR) with the Edwards Sapien 3 device. BACKGROUND: The TC approach for TAVR holds the potential to become the optimal alternative to the transfemoral gold standard. Limited data exist regarding safety and efficacy of TC-TAVR using the Edwards Sapien 3 device. METHODS: The French Transcarotid TAVR prospective multicenter registry included patients between 2014 and 2018. Consecutive patients treated in 1 of the 13 participating centers ineligible for transfemoral TAVR were screened for TC-TAVR. Clinical and echocardiographic data were prospectively collected. Perioperative and 30-day outcomes were reported according to the updated Valve Academic Research Consortium (VARC-2). RESULTS: A total of 314 patients were included with a median (interquartile range) age of 83 (78 to 88) years, 63% were males, Society of Thoracic Surgeons mortality risk score 5.8% (4% to 8.3%). Most patients presented with peripheral artery disease (64%). TC-TAVR was performed under general anesthesia in 91% of cases, mostly using the left carotid artery (73.6%) with a procedural success of 97%. Three annulus ruptures were reported, all resulting in patient death. At 30 days, rates of major bleeding, new permanent pacemaker, and stroke or transient ischemic attack were 4.1%, 16%, and 1.6%, respectively. The 30-day mortality was 3.2%. CONCLUSIONS: TC-TAVR using the Edwards Sapien 3 device was safe and effective in this prospective multicenter registry. The TC approach might be considered, in selected patients, as the first-line alternative approach for TAVR whenever the transfemoral access is prohibited. Sapien 3 device was safe and effective in our multicenter cohort.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Artérias Carótidas , Cateterismo Periférico , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , França , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Desenho de Prótese , Punções , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
3.
Circulation ; 138(23): 2597-2607, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30571260

RESUMO

BACKGROUND: The FRANCE-2 registry (French Aortic National Corevalve and Edwards) previously reported good early- and medium-term clinical and echocardiographic efficacy for transcatheter aortic valve replacement. We here report 5-year follow-up results from the registry. METHODS: The registry includes all consecutive patients undergoing transcatheter aortic valve replacement for severe aortic stenosis in France. Follow-up is scheduled at 30 days, 6 months, then annually from 1 to 5 years. Clinical events were defined according to the Valve Academic Research Consortium criteria, and hemodynamic structural valve deterioration (SVD) was defined according to the consensus statement by the European Association of Percutaneous Cardiovascular Interventions. RESULTS: Between January 2010 and January 2012, 4201 patients were enrolled in 34 centers. Five-year vital status was available for 95.5% of patients; 88.1% had clinical evaluation or died. Overall, at 5 years, all-cause mortality was 60.8% (n=2478; 95% CI, 59.3% to 62.3%). The majority of cardiovascular events occurred in the first month after valve implantation, and incidence remained low thereafter, at <2% per year up to 5 years, except for heart failure. The rate of heart failure was 14.3% at 1 year, then decreased over time to <5% per year. In cumulative incidence function, the rates of severe SVD and moderate/severe SVD at 5 years were 2.5% and 13.3%, respectively. Mortality did not differ between patients with or without severe SVD (hazard ratio, 0.71; 95% CI, 0.47-1.07; P=0.1). Finally, in the population of patients with severe SVD, 1 patient (1.7%) experienced a stroke, and 8 patients presented ≥1 heart failure event (13.3%). CONCLUSIONS: The 5-year follow-up results of the FRANCE-2 registry represent the largest long-term data set available in a high-risk population. In surviving patients, the low rate of clinical events and the low level of SVD after 1 year support the long-term efficacy of transcatheter aortic valve replacement in both types of transcatheter prosthesis featuring in the registry.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Falha de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Hemodinâmica , Humanos , Masculino , Modelos de Riscos Proporcionais , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
4.
J Am Coll Cardiol ; 70(1): 42-55, 2017 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-28662806

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is standard therapy for patients with severe aortic stenosis who are at high surgical risk. However, national data regarding procedural characteristics and clinical outcomes over time are limited. OBJECTIVES: The aim of this study was to assess nationwide performance trends and clinical outcomes of TAVR during a 6-year period. METHODS: TAVRs performed in 48 centers across France between January 2013 and December 2015 were prospectively included in the FRANCE TAVI (French Transcatheter Aortic Valve Implantation) registry. Findings were further compared with those reported from the FRANCE 2 (French Aortic National CoreValve and Edwards 2) registry, which captured all TAVRs performed from January 2010 to January 2012 across 34 centers. RESULTS: A total of 12,804 patients from FRANCE TAVI and 4,165 patients from FRANCE 2 were included in this analysis. The median age of patients was 84.6 years, and 49.7% were men. FRANCE TAVI participants were older but at lower surgical risk (median logistic European System for Cardiac Operative Risk Evaluation [EuroSCORE]: 15.0% vs. 18.4%; p < 0.001). More than 80% of patients in FRANCE TAVI underwent transfemoral TAVR. Transesophageal echocardiography guidance decreased from 60.7% to 32.3% of cases, whereas more recent procedures were increasingly performed in hybrid operating rooms (15.8% vs. 35.7%). Rates of Valve Academic Research Consortium-defined device success increased from 95.3% in FRANCE 2 to 96.8% in FRANCE TAVI (p < 0.001). In-hospital and 30-day mortality rates were 4.4% and 5.4%, respectively, in FRANCE TAVI compared with 8.2% and 10.1%, respectively, in FRANCE 2 (p < 0.001 for both). Stroke and potentially life-threatening complications, such as annulus rupture or aortic dissection, remained stable over time, whereas rates of cardiac tamponade and pacemaker implantation significantly increased. CONCLUSIONS: The FRANCE TAVI registry provided reassuring data regarding trends in TAVR performance in an all-comers population on a national scale. Nonetheless, given that TAVR indications are likely to expand to patients at lower surgical risk, concerns remain regarding potentially life-threatening complications and pacemaker implantation. (Registry of Aortic Valve Bioprostheses Established by Catheter [FRANCE TAVI]; NCT01777828).


Assuntos
Estenose da Valva Aórtica/cirurgia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/tendências , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/epidemiologia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , França/epidemiologia , Humanos , Incidência , Masculino , Prognóstico , Estudos Prospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo
5.
J Am Coll Cardiol ; 68(15): 1637-1647, 2016 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-27712776

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has revolutionized management of high-risk patients with severe aortic stenosis. However, survival and the incidence of severe complications have been assessed in relatively small populations and/or with limited follow-up. OBJECTIVES: This report details late clinical outcome and its determinants in the FRANCE-2 (FRench Aortic National CoreValve and Edwards) registry. METHODS: The FRANCE-2 registry prospectively included all TAVRs performed in France. Follow-up was scheduled at 30 days, at 6 months, and annually from 1 to 5 years. Standardized VARC (Valve Academic Research Consortium) outcome definitions were used. RESULTS: A total of 4,201 patients were enrolled between January 2010 and January 2012 in 34 centers. Approaches were transarterial (transfemoral 73%, transapical 18%, subclavian 6%, and transaortic or transcarotid 3%) or, in 18% of patients, transapical. Median follow-up was 3.8 years. Vital status was available for 97.2% of patients at 3 years. The 3-year all-cause mortality was 42.0% and cardiovascular mortality was 17.5%. In a multivariate model, predictors of 3-year all-cause mortality were male sex (p < 0.001), low body mass index, (p < 0.001), atrial fibrillation (p < 0.001), dialysis (p < 0.001), New York Heart Association functional class III or IV (p < 0.001), higher logistic EuroSCORE (p < 0.001), transapical or subclavian approach (p < 0.001 for both vs. transfemoral approach), need for permanent pacemaker implantation (p = 0.02), and post-implant periprosthetic aortic regurgitation grade ≥2 of 4 (p < 0.001). Severe events according to VARC criteria occurred mainly during the first month and subsequently in <2% of patients/year. Mean gradient, valve area, and residual aortic regurgitation were stable during follow-up. CONCLUSIONS: The FRANCE-2 registry represents the largest database available on late results of TAVR. Late mortality is largely related to noncardiac causes. Incidence rates of severe events are low after the first month. Valve performance remains stable over time.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Feminino , França , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Arch Cardiovasc Dis ; 107(4): 225-35, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24794216

RESUMO

BACKGROUND: Dual antiplatelet therapy, comprising aspirin and clopidogrel, is recommended in patients undergoing coronary stenting to avoid the occurrence of stent thrombosis and others ischaemic events. Interindividual response to clopidogrel varies, however, with poor response associated with an increased risk of ischaemic events. New assays are available for testing aspirin and clopidogrel response routinely at the bedside. AIM: To evaluate the prognostic value of testing antiplatelet response in an intermediate-risk population undergoing stent implantation. METHODS: We prospectively assessed clopidogrel and aspirin response using the VerifyNow assay at the time of coronary stenting in 1001 patients who presented with stable coronary disease or non-ST-segment elevation acute coronary syndrome. The main ischaemic endpoint was the composite of definite and probable stent thrombosis, cardiovascular death or spontaneous myocardial infarction at one year. The safety endpoint was major bleeding. RESULTS: Overall, 36.0% of patients had high on-clopidogrel platelet reactivity (OCR) and 8.6% had high on-aspirin platelet reactivity (OAR). The main ischaemic composite endpoint occurred in 3.9% of patients with high vs. 2.3% of patients with normal OCR (hazard ratio 1.66, 95% confidence interval 0.78-3.54; P=0.18). Definite or probable stent thrombosis occurred in 1.1% of patients with high vs. 0.3% of patients with normal OCR (P=0.86). There was no significant difference in ischaemic endpoints according to OAR and there was no difference in rates of major bleeding between patients with high versus normal on-treatment platelet reactivity. CONCLUSIONS: On-treatment platelet reactivity was not associated with 1-year ischaemic or bleeding events in an intermediate-risk population undergoing stent implantation.


Assuntos
Aspirina/uso terapêutico , Trombose Coronária/prevenção & controle , Hemorragia/induzido quimicamente , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/uso terapêutico , Testes de Função Plaquetária , Stents , Ticlopidina/análogos & derivados , Idoso , Aspirina/efeitos adversos , Clopidogrel , Trombose Coronária/diagnóstico , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Quimioterapia Combinada , Feminino , França , Hemorragia/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Ticlopidina/efeitos adversos , Ticlopidina/uso terapêutico , Resultado do Tratamento
7.
N Engl J Med ; 366(18): 1705-15, 2012 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-22551129

RESUMO

BACKGROUND: Transcatheter aortic-valve implantation (TAVI) is an emerging intervention for the treatment of high-risk patients with severe aortic stenosis and coexisting illnesses. We report the results of a prospective multicenter study of the French national transcatheter aortic-valve implantation registry, FRANCE 2. METHODS: All TAVIs performed in France, as listed in the FRANCE 2 registry, were prospectively included in the study. The primary end point was death from any cause. RESULTS: A total of 3195 patients were enrolled between January 2010 and October 2011 at 34 centers. The mean (±SD) age was 82.7±7.2 years; 49% of the patients were women. All patients were highly symptomatic and were at high surgical risk for aortic-valve replacement. Edwards SAPIEN and Medtronic CoreValve devices were implanted in 66.9% and 33.1% of patients, respectively. Approaches were either transarterial (transfemoral, 74.6%; subclavian, 5.8%; and other, 1.8%) or transapical (17.8%). The procedural success rate was 96.9%. Rates of death at 30 days and 1 year were 9.7% and 24.0%, respectively. At 1 year, the incidence of stroke was 4.1%, and the incidence of periprosthetic aortic regurgitation was 64.5%. In a multivariate model, a higher logistic risk score on the European System for Cardiac Operative Risk Evaluation (EuroSCORE), New York Heart Association functional class III or IV symptoms, the use of a transapical TAVI approach, and a higher amount of periprosthetic regurgitation were significantly associated with reduced survival. CONCLUSIONS: This prospective registry study reflected real-life TAVI experience in high-risk elderly patients with aortic stenosis, in whom TAVI appeared to be a reasonable option. (Funded by Edwards Lifesciences and Medtronic.).


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Cateterismo Cardíaco/métodos , Feminino , França/epidemiologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemorragia/epidemiologia , Hemorragia/etiologia , Humanos , Incidência , Masculino , Análise Multivariada , Estudos Prospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...