Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
3.
Gut ; 25(12): 1424-31, 1984 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-6510772

RESUMO

Several inexpensive endoscopic methods of electrocoagulation have been advocated for treatment of gastrointestinal haemorrhage. We compared four types of electrode: dry monopolar - Cameron Miller (M), liquid monopolar - Storz (L), bipolar - Bicap ACMI (B), and heater probe - Seattle (H). The electrical and thermal properties of these probes were studied using computerised monitoring of energy deposition and their efficacy and safety was tested in a randomised study in 140 experimental canine gastric ulcers. At optimal pulse settings 20J (M), 70J (L), 17J (B), 15J (H), effective haemostasis was achieved in all ulcers, the mean number of pulses being M5, L6, H6 and B11, the first three requiring significantly (p less than 0.01) less pulse than B. Relative safety of the electrodes was assessed by comparing the incidence of full thickness damage at histology: B24%, H20%, L58% and M69%; B and H proving significantly (p less than 0.01) safer than L and M. Sticking was assessed as H greater than B greater than M much greater than L. Insensitivity to extreme angulation and force of application was assessed as L greater than B greater than M (H is preset). Of the two safer electrodes the heater probe was more effective than the bipolar probe. Despite its greater tendency to stick than the other devices, the heater probe appeared the most promising of the endoscopic electrodes tested.


Assuntos
Eletrocoagulação/métodos , Úlcera Péptica Hemorrágica/cirurgia , Úlcera Gástrica/complicações , Animais , Cães , Eletrocoagulação/instrumentação , Eletrodos , Estudos de Avaliação como Assunto , Feminino , Gastroscopia , Fígado , Distribuição Aleatória , Suínos
6.
Arch Dis Child ; 53(2): 169-72, 1978 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-646422

RESUMO

A computer system has been used for the recording and display of data from 277 infants with respiratory illnesses consecutively admitted to a neonatal intensive care unit during a period of 25 months. Improved efficiency of data handling was demonstrated, and the system proved valuable for teaching and research.


Assuntos
Computadores , Doenças do Recém-Nascido , Transtornos Respiratórios , Apresentação de Dados , Humanos , Recém-Nascido , Unidades de Terapia Intensiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA