Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Prehosp Emerg Care ; 16(3): 407-11, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22235798

RESUMO

When responders are dealing with an agitated patient in the field, safety for all involved may sometimes only be accomplished with physical or chemical restraints. While experiences using chemical restraint in the prehospital setting are found in the medical literature, the use of this by law enforcement as a first-response restraint has not previously been described. We report a case of successful law enforcement-administered sedation of a noncommunicative, autistic, and violent minor using intramuscular droperidol and diphenhydramine. Although this case has some unique characteristics that allowed chemical restraint to be given by the law enforcement agency, it calls attention to some specific prehospital issues that need to be addressed when dealing with autistic patients with extreme agitation.


Assuntos
Sedação Consciente , Antagonistas de Dopamina/uso terapêutico , Serviços Médicos de Emergência , Hipnóticos e Sedativos/uso terapêutico , Aplicação da Lei , Adolescente , Transtorno Autístico , Difenidramina/administração & dosagem , Difenidramina/uso terapêutico , Antagonistas de Dopamina/administração & dosagem , Droperidol/administração & dosagem , Droperidol/uso terapêutico , Humanos , Hipnóticos e Sedativos/administração & dosagem , Masculino , Minnesota
2.
J Emerg Med ; 41(3): 317-23, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20117901

RESUMO

BACKGROUND: The TASER(®) X26 Conducted Electrical Weapon (CEW) provides painful stimuli and neuromuscular incapacitation to potentially violent persons. Use by law enforcement in society is common. Presenting a CEW is known to de-escalate some situations. Health care personnel sometimes encounter violent persons within the confines of the hospital. CEW use by health care security personnel has not been described. OBJECTIVE: The objective is to describe results from the introduction of the CEW into a hospital environment. METHODS: Upon introducing the CEW into an urban hospital campus, standardized reports were made describing all CEW use by hospital security. Reports were retrospectively reviewed for the first 12 months of CEW use. Collected data included force options used, potential injuries avoided, witness comments, outcomes, and whether the CEW required full activation or if inactive presentation was sufficient to control the situation. Rates of security personnel injuries were also gathered. Descriptive analysis was applied. RESULTS: Twenty-seven CEW deployments occurred: four were inactive presentation, 20 were presentation with LASER sight activation, and three were probe deployments with a 5-s delivery of electrical current. Two persons required evaluation for minor injuries not related to CEW use. Witnesses reported that in all incidents, injuries were likely avoided due to CEW presentation or use. CEW use aborted one suicide attempt. Personnel injury rates decreased during the study period. CONCLUSION: CEW introduction into a health care setting demonstrated the ability to avert and control situations that could result in further injury to subjects, patients, and personnel. This correlates with a decrease in injury for hospital personnel. Further study is recommended for validation.


Assuntos
Lesões por Armas de Eletrochoque/epidemiologia , Serviço Hospitalar de Emergência/estatística & dados numéricos , Aplicação da Lei/métodos , Violência/prevenção & controle , Armas , Hospitais Urbanos/estatística & dados numéricos , Humanos , Recursos Humanos em Hospital/estatística & dados numéricos , Estudos Retrospectivos , Armas/estatística & dados numéricos
3.
Disaster Med Public Health Prep ; 2 Suppl 1: S11-6, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18769260

RESUMO

BACKGROUND: We describe the hospital system response to the Interstate 35W bridge collapse in Minneapolis into the Mississippi River on August 1, 2007, which resulted in 13 deaths and 127 injuries. Comparative analysis of response activities at the 3 hospitals that received critical or serious casualties is provided. METHODS: First-hand experiences of hospital physicians, issues identified in after-action reports, injury severity scores, and other relevant patient data were collected from the 3 hospitals that received seriously injured patients, including the closest hospitals to the collapse on each side of the river. RESULTS/DISCUSSION: Injuries were consistent with major acceleration/deceleration force injuries. The most critical patients arrived first at each hospital, suggesting appropriate prehospital triage. Capacity of the health care system was not overwhelmed and the involved hospitals generally reported an overresponse by staff. Communication and patient tracking problems occurred at all of the hospitals. Situational awareness was limited due to the scope of structural collapse and incomplete information from the scene. CONCLUSIONS: Hospitals were generally satisfied with their surge capacity and incident management plan activation. Issues such as communications, patient tracking, and staff overreporting that have been identified in past incidents also were problematic in this event. Hospitals will need to address deficiencies and build on successful actions to cope with future, potentially larger incidents.


Assuntos
Acidentes de Trânsito , Automóveis , Planejamento em Desastres , Desastres , Serviço Hospitalar de Emergência , Triagem , Humanos , Escala de Gravidade do Ferimento , Ferimentos e Lesões
4.
Disaster Med Public Health Prep ; 2 Suppl 1: S17-24, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18769261

RESUMO

BACKGROUND: The Interstate 35W Bridge in Minneapolis collapsed into the Mississippi River on August 1, 2007, killing 13 people and injuring 127. METHODS: This article describes the emergency medical services response to this incident. RESULTS/DISCUSSION: Complexities of the event included difficult patient access, multiple sectors of operation, and multiple mutual-aid agencies. Patient evacuation and transportation was rapid, with the collapse zone cleared of victims 95 minutes after the initial 9-1-1 call. A common regional emergency medical service incident management plan that was exercised was critical to the success of the response. CONCLUSIONS: Communication and patient tracking difficulties could be improved in future responses.


Assuntos
Acidentes de Trânsito , Automóveis , Desastres , Serviço Hospitalar de Emergência/organização & administração , Incidentes com Feridos em Massa , Triagem , Comunicação , Humanos , Minnesota , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...