Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mech Time Depend Mater ; 22(2): 145-165, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29962897

RESUMO

An established statistical mechanical theory of amorphous polymer deformation has been incorporated as a plastic mechanism into a constitutive model and applied to a range of polymer mechanical deformations. The temperature and rate dependence of the tensile yield of PVC, as reported in early studies, has been modeled to high levels of accuracy. Tensile experiments on PET reported here are analyzed similarly and good accuracy is also achieved. The frequently observed increase in the gradient of the plot of yield stress against logarithm of strain rate is an inherent feature of the constitutive model. The form of temperature dependence of the yield that is predicted by the model is found to give an accurate representation. The constitutive model is developed in two-dimensional form and implemented as a user-defined subroutine in the finite element package ABAQUS. This analysis is applied to the tensile experiments on PET, in some of which strain is localized in the form of shear bands and necks. These deformations are modeled with partial success, though adiabatic heating of the instability causes inaccuracies for this isothermal implementation of the model. The plastic mechanism has advantages over the Eyring process, is equally tractable, and presents no particular difficulties in implementation with finite elements.

2.
Spectrochim Acta A Mol Biomol Spectrosc ; 61(13-14): 2946-52, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16165036

RESUMO

The cure of polydicyclopentadiene conducted by ring-opening metathesis polymerisation in the presence of a Grubbs catalyst was studied using non-invasive Raman spectroscopy. The spectra of the monomer precursor and polymerised product were fully characterised and all stages of polymerisation monitored. Because of the monomer's high reactivity, the cure process is adaptable to reaction injection moulding and reactive rotational moulding. The viscosity of the dicyclopentadiene undergoes a rapid change at the beginning of the polymerisation process and it is critical that the induction time of the viscosity increase is determined and controlled for successful manufacturing. The results from this work show non-invasive Raman spectroscopic monitoring to be an effective method for monitoring the degree of cure, paving the way for possible implementation of the technique as a method of real-time analysis for control and optimisation during reactive processing. Agreement is shown between Raman measurements and ultrasonic time of flight data acquired during the initial induction period of the curing process.


Assuntos
Indenos/química , Catálise , Estrutura Molecular , Rutênio/química , Análise Espectral Raman
3.
Appl Spectrosc ; 59(5): 611-9, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15969806

RESUMO

Spectroscopic techniques such as Raman, mid-infrared (MIR), and near-infrared (NIR) have become indispensable analytical tools for rapid chemical quality control and process monitoring. This paper presents the application of in-line Fourier transform near-infrared (FT-NIR) spectroscopy, Raman spectroscopy, and ultrasound transit time measurements for in-line monitoring of the composition of a series of high-density polyethylene (HDPE)/polypropylene (PP) blends during single-screw extrusion. Melt composition was determined by employing univariate analysis of the ultrasound transit time data and partial least squares (PLS) multivariate analysis of the data from both spectroscopic techniques. Each analytical technique was determined to be highly sensitive to changes in melt composition, allowing accurate prediction of blend content to within +/- 1% w/w (1sigma) during monitoring under fixed extrusion conditions. FT-NIR was determined to be the most sensitive of the three techniques to changes in melt composition. A four-factor PLS model of the NIR blend spectra allowed determination of melt content with a standard prediction error of +/- 0.30% w/w (1sigma). However, the NIR transmission probes employed for analysis were invasive into the melt stream, whereas the single probes adopted for Raman and ultrasound analysis were noninvasive, making these two techniques more versatile. All three measurement techniques were robust to the high temperatures and pressures experienced during melt extrusion, demonstrating each system's suitability for process monitoring and control.


Assuntos
Algoritmos , Manufaturas/análise , Teste de Materiais/métodos , Polietileno/química , Polipropilenos/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Análise Espectral Raman/métodos , Ultrassonografia/métodos , Técnicas de Química Combinatória/métodos , Sistemas On-Line , Polietileno/análise , Polipropilenos/análise , Integração de Sistemas , Temperatura de Transição , Vibração
4.
Science ; 301(5640): 1691-5, 2003 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-14500974

RESUMO

Flows of complex fluids need to be understood at both macroscopic and molecular scales, because it is the macroscopic response that controls the fluid behavior, but the molecular scale that ultimately gives rise to rheological and solid-state properties. Here the flow field of an entangled polymer melt through an extended contraction, typical of many polymer processes, is imaged optically and by small-angle neutron scattering. The dual-probe technique samples both the macroscopic stress field in the flow and the microscopic configuration of the polymer molecules at selected points. The results are compared with a recent "tube model" molecular theory of entangled melt flow that is able to calculate both the stress and the single-chain structure factor from first principles. The combined action of the three fundamental entangled processes of reptation, contour length fluctuation, and convective constraint release is essential to account quantitatively for the rich rheological behavior. The multiscale approach unearths a new feature: Orientation at the length scale of the entire chain decays considerably more slowly than at the smaller entanglement length.

5.
Biomaterials ; 23(21): 4295-302, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12194532

RESUMO

The commercial success of hydroxyapatite (HA) filled polyethylene composite has generated growing interest in improving the processability of the composite. A number of synthetic procedures and post synthesis heat treatment of HA has lead to the availability of powders with widely varying morphological features. This paper addresses the effect of morphological features of HA on the rheology and processability of an injection-moulding grade HA-HDPE composite. The results showed that low surface area HA filled composite exhibited better injection processing characteristics through improved rheological responses. The effect of reducing the surface area of the filler is to require less polyethylene to wet the filler and allows more polyethylene to be involved in the flow processes. These changes reduced the temperatures and pressures required for successful processing.


Assuntos
Materiais Biocompatíveis/química , Durapatita/química , Polietilenos/química , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Reologia , Propriedades de Superfície , Temperatura
6.
Lancet ; 2(8665): 704-9, 1989 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-2570958

RESUMO

101 critically ill patients admitted to five intensive-care units were allocated randomly to receive a continuous intravenous infusion of either propofol or midazolam for sedation for up to 24 h. In addition, morphine was given to provide analgesia. The mean duration of infusion was 20.2 h (range 3.0-24.5) in the propofol group and 21.3 h (4.0-47.0) in the midazolam group and infusion rates were 1.77 mg/kg/h (range 0.40-5.00) and 0.10 mg/kg/h (0.01-0.26), respectively. The infusion rates were adjusted as necessary, and the desired level of sedation was achieved easily in most patients in both groups. There were slight falls in arterial pressure, but there were no significant differences between the groups. Heart rate was lower in patients who received propofol. Some small changes occurred in biochemical and haematological variables in both groups, but they were not clinically significant. There was no indication that either drug substantially impaired adrenal steroidogenesis. When the infusion was discontinued, there was less variability in recovery of consciousness in patients who had received propofol. In a subgroup of patients, weaning from mechanical ventilation was achieved significantly faster after discontinuation of propofol than of midazolam. Propofol proved to be a satisfactory agent for sedation of these critically ill patients and compared favourably with midazolam.


Assuntos
Cuidados Críticos , Hipnóticos e Sedativos/uso terapêutico , Midazolam/uso terapêutico , Fenóis/uso terapêutico , Adolescente , Adulto , Idoso , Pressão Sanguínea/efeitos dos fármacos , Avaliação de Medicamentos , Feminino , Humanos , Hidrocortisona/sangue , Hipnóticos e Sedativos/administração & dosagem , Infusões Intravenosas , Injeções , Masculino , Midazolam/administração & dosagem , Pessoa de Meia-Idade , Morfina/administração & dosagem , Morfina/uso terapêutico , Estudos Multicêntricos como Assunto , Fenóis/administração & dosagem , Propofol , Distribuição Aleatória , Índice de Gravidade de Doença , Fatores de Tempo , Desmame do Respirador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA