Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Bone Joint J ; 101-B(4): 426-434, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30929480

RESUMO

AIMS: The hip's capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function. MATERIALS AND METHODS: Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips). RESULTS: Hip resurfacing provided a near-native ROM with between 5° to 17° increase in IR/ER ROM compared with the native hip for the different positions tested, which was a 9% to 33% increase. DM-THA generated a 9° to 61° (18% to 121%) increase in ROM. Conventional THA generated a 52° to 100° (94% to 199%) increase in ROM. Thus, for conventional THA, the capsule function that exerts a limit on ROM is lost. It is restored to some extent by DM-THA, and almost fully restored by hip resurfacing. In positions of low flexion/extension, the posterior capsulotomy provided more normal function than the anterior, possibly because the capsule was shortened during posterior repair. However, in deep flexion positions, the anterior capsulotomy functioned better. CONCLUSION: Native head-size and capsular repair preserves capsular function after arthroplasty. The anterior and posterior approach differentially affect postoperative biomechanical function of the capsular ligaments. Cite this article: Bone Joint J 2019;101-B:426-434.


Assuntos
Artroplastia de Quadril , Cabeça do Fêmur/cirurgia , Articulação do Quadril/fisiopatologia , Cápsula Articular/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Adulto , Idoso , Fenômenos Biomecânicos , Cadáver , Feminino , Articulação do Quadril/cirurgia , Prótese de Quadril , Humanos , Cápsula Articular/cirurgia , Ligamentos Articulares/fisiopatologia , Masculino , Pessoa de Meia-Idade
2.
Bone Joint Res ; 7(8): 524-538, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30258572

RESUMO

OBJECTIVES: The ability to determine human bone stiffness is of clinical relevance in many fields, including bone quality assessment and orthopaedic prosthesis design. Stiffness can be measured using compression testing, an experimental technique commonly used to test bone specimens in vitro. This systematic review aims to determine how best to perform compression testing of human bone. METHODS: A keyword search of all English language articles up until December 2017 of compression testing of bone was undertaken in Medline, Embase, PubMed, and Scopus databases. Studies using bulk tissue, animal tissue, whole bone, or testing techniques other than compression testing were excluded. RESULTS: A total of 4712 abstracts were retrieved, with 177 papers included in the analysis; 20 studies directly analyzed the compression testing technique to improve the accuracy of testing. Several influencing factors should be considered when testing bone samples in compression. These include the method of data analysis, specimen storage, specimen preparation, testing configuration, and loading protocol. CONCLUSION: Compression testing is a widely used technique for measuring the stiffness of bone but there is a great deal of inter-study variation in experimental techniques across the literature. Based on best evidence from the literature, suggestions for bone compression testing are made in this review, although further studies are needed to establish standardized bone testing techniques in order to increase the comparability and reliability of bone stiffness studies.Cite this article: S. Zhao, M. Arnold, S. Ma, R. L. Abel, J. P. Cobb, U. Hansen, O. Boughton. Standardizing compression testing for measuring the stiffness of human bone. Bone Joint Res 2018;7:524-538. DOI: 10.1302/2046-3758.78.BJR-2018-0025.R1.

3.
Arch Orthop Trauma Surg ; 138(11): 1601-1608, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30178169

RESUMO

INTRODUCTION: High-volume unicompartmental knee arthroplasty (UKA) surgeons have lower revision rates, in part due to improved intra-operative component alignment. This study set out to determine whether PSI might allow non-expert surgeons to achieve the same level of accuracy as expert surgeons. MATERIALS AND METHODS: Thirty-four surgical trainees with no prior experience of UKA, and four high-volume UKA surgeons were asked to perform the tibial saw cuts for a medial UKA in a sawbone model using both conventional and patient-specific instrumentation (PSI) with the aim of achieving a specified pre-operative plan. Half the participants in each group started with conventional instrumentation, and half with PSI. CT scans of the 76 cut sawbones were then segmented and reliably orientated in space, before saw cut position in the sagittal, coronal and axial planes was measured, and compared to the pre-operative plan. RESULTS: The compound error (absolute error in the coronal, sagittal and axial planes combined) for experts using conventional instruments was significantly less than that of the trainees (11.6°±4.0° v 7.7° ±2.3º, p = 0.029). PSI improved trainee accuracy to the same level as experts using conventional instruments (compound error 5.5° ±3.4º v 7.7° ±2.3º, p = 0.396) and patient-specific instruments (compound error 5.5° ±3.4º v 7.3° ±4.1º, p = 0.3). PSI did not improve the accuracy of high-volume surgeons (p = 0.3). CONCLUSIONS: In a sawbone model, PSI allowed inexperienced surgeons to achieve more accurate saw cuts, equivalent to expert surgeons, and thus has the potential to reduce revision rates. The next test will be to determine whether these results can be replicated in a clinical trial.


Assuntos
Artroplastia do Joelho/instrumentação , Competência Clínica/estatística & dados numéricos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Artroplastia do Joelho/métodos , Simulação por Computador , Humanos , Prótese do Joelho/efeitos adversos , Reprodutibilidade dos Testes , Cirurgiões , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X
4.
Bone Joint Res ; 6(8): 522-529, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28855192

RESUMO

OBJECTIVES: Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain. METHODS: A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system. RESULTS: A 5° increase in tibial component posterior slope resulted in a 53% increase in mean major principal strain in the posterior tibial zone adjacent to the implant (p = 0.003). The highest strains for all implant positions were recorded in the anterior cortex 2 cm to 3 cm distal to the implant. Posteriorly, strain tended to decrease with increasing distance from the implant. Lateral cortical strain showed no significant relationship with implant position. CONCLUSION: Relatively small changes in implant position and orientation may significantly affect tibial cortical strain. Avoidance of excessive posterior tibial slope may be advisable during lateral UKA.Cite this article: A. M. Ali, S. D. S. Newman, P. A. Hooper, C. M. Davies, J. P. Cobb. The effect of implant position on bone strain following lateral unicompartmental knee arthroplasty: A Biomechanical Model Using Digital Image Correlation. Bone Joint Res 2017;6:522-529. DOI: 10.1302/2046-3758.68.BJR-2017-0067.R1.

5.
Bone Joint Res ; 6(9): 542-549, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28924020

RESUMO

OBJECTIVES: Microindentation has the potential to measure the stiffness of an individual patient's bone. Bone stiffness plays a crucial role in the press-fit stability of orthopaedic implants. Arming surgeons with accurate bone stiffness information may reduce surgical complications including periprosthetic fractures. The question addressed with this systematic review is whether microindentation can accurately measure cortical bone stiffness. METHODS: A systematic review of all English language articles using a keyword search was undertaken using Medline, Embase, PubMed, Scopus and Cochrane databases. Studies that only used nanoindentation, cancellous bone or animal tissue were excluded. RESULTS: A total of 1094 abstracts were retrieved and 32 papers were included in the analysis, 20 of which used reference point indentation, and 12 of which used traditional depth-sensing indentation. There are several factors that must be considered when using microindentation, such as tip size, depth and method of analysis. Only two studies validated microindentation against traditional mechanical testing techniques. Both studies used reference point indentation (RPI), with one showing that RPI parameters correlate well with mechanical testing, but the other suggested that they do not. CONCLUSION: Microindentation has been used in various studies to assess bone stiffness, but only two studies with conflicting results compared microindentation with traditional mechanical testing techniques. Further research, including more studies comparing microindentation with other mechanical testing methods, is needed before microindentation can be used reliably to calculate cortical bone stiffness.Cite this article: M. Arnold, S. Zhao, S. Ma, F. Giuliani, U. Hansen, J. P. Cobb, R. L. Abel, O. Boughton. Microindentation - a tool for measuring cortical bone stiffness? A systematic review. Bone Joint Res 2017;6:542-549. DOI: 10.1302/2046-3758.69.BJR-2016-0317.R2.

7.
Gait Posture ; 51: 162-168, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27776270

RESUMO

Gait asymmetry information is a key point in disease screening and follow-up. Constant Relative Phase (CRP) has been used to quantify within-stride asymmetry index, which requires noise-free and accurate motion capture, which is difficult to obtain in clinical settings. This study explores a new index, the Longitudinal Asymmetry Index (ILong) which is derived using data from a low-cost depth camera (Kinect). ILong is based on depth images averaged over several gait cycles, rather than derived joint positions or angles. This study aims to evaluate (1) the validity of CRP computed with Kinect, (2) the validity and sensitivity of ILong for measuring gait asymmetry based solely on data provided by a depth camera, (3) the clinical applicability of a posteriorly mounted camera system to avoid occlusion caused by the standard front-fitted treadmill consoles and (4) the number of strides needed to reliably calculate ILong. The gait of 15 subjects was recorded concurrently with a marker-based system (MBS) and Kinect, and asymmetry was artificially reproduced by introducing a 5cm sole attached to one foot. CRP computed with Kinect was not reliable. ILong detected this disturbed gait reliably and could be computed from a posteriorly placed Kinect without loss of validity. A minimum of five strides was needed to achieve a correlation coefficient of 0.9 between standard MBS and low-cost depth camera based ILong. ILong provides a clinically pragmatic method for measuring gait asymmetry, with application for improved patient care through enhanced disease, screening, diagnosis and monitoring.


Assuntos
Fenômenos Biomecânicos , Marcha , Caminhada , Adulto , Teste de Esforço , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software
8.
Bone Joint J ; 98-B(10 Supple B): 16-21, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27694511

RESUMO

AIMS: To compare the gait of unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) patients with healthy controls, using a machine-learning approach. PATIENTS AND METHODS: 145 participants (121 healthy controls, 12 patients with cruciate-retaining TKA, and 12 with mobile-bearing medial UKA) were recruited. The TKA and UKA patients were a minimum of 12 months post-operative, and matched for pattern and severity of arthrosis, age, and body mass index. Participants walked on an instrumented treadmill until their maximum walking speed was reached. Temporospatial gait parameters, and vertical ground reaction force data, were captured at each speed. Oxford knee scores (OKS) were also collected. An ensemble of trees algorithm was used to analyse the data: 27 gait variables were used to train classification trees for each speed, with a binary output prediction of whether these variables were derived from a UKA or TKA patient. Healthy control gait data was then tested by the decision trees at each speed and a final classification (UKA or TKA) reached for each subject in a majority voting manner over all gait cycles and speeds. Top walking speed was also recorded. RESULTS: 92% of the healthy controls were classified by the decision tree as a UKA, 5% as a TKA, and 3% were unclassified. There was no significant difference in OKS between the UKA and TKA patients (p = 0.077). Top walking speed in TKA patients (1.6 m/s; 1.3 to 2.1) was significantly lower than that of both the UKA group (2.2 m/s; 1.8 to 2.7) and healthy controls (2.2 m/s; 1.5 to 2.7; p < 0.001). CONCLUSION: UKA results in a more physiological gait compared with TKA, and a higher top walking speed. This difference in function was not detected by the OKS. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):16-21.


Assuntos
Artroplastia do Joelho/métodos , Marcha/fisiologia , Osteoartrite do Joelho/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Teste de Esforço/métodos , Humanos , Articulação do Joelho/fisiopatologia , Aprendizado de Máquina , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Resultado do Tratamento , Caminhada/fisiologia , Adulto Jovem
9.
Knee ; 22(4): 286-91, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26006772

RESUMO

BACKGROUND: There has been a significant rise in the number and value of claims against the National Health Service (NHS), with limited studies on litigation in orthopaedic surgery and none in knee surgery alone. We aimed to examine claims against the NHS involving all aspects of knee surgery with respect to costs and trends. CLINICAL RELEVANCE: To raise awareness of the reasons for litigation in knee surgery, thus potentially improve patient care and reduce future claims. METHODS: We analysed the NHS litigation authority (NHSLA) database for all orthopaedic surgery claims reported to the NHSLA between 2005 and 2010, with calculation of litigation success rates and odds ratios for those relating to knee surgery. RESULTS: There were 515 cases identified from the 4609 orthopaedic cases in the NHSLA database (11.2%): 298 (58%) involving total knee replacements (TKRs), 11 (2%) involving unicondylar knee replacements, and 90 cases (30%) remaining open. The total pay out for closed cases was £10.45 million and amputation following TKR resulted in the highest single pay out. Litigation success rates for claimants were highest for retained drains (100%), incorrect prosthesis/prosthesis size (78%), renal failure (75%), poor outcome requiring further surgery (74%) and malalignment (71%). There were also 60 cases of delayed diagnosis which resulted in pay outs totalling £2.90 million. Based on these data, projected future pay out costs for the open TKR cases were estimated to be £2.71 million. CONCLUSION: Litigation success rates for TKR were highest following technical errors such as malalignment compared to events less under the surgeon's control, such as infection. The number of claims involving incorrect prosthesis/size continues to be of concern. Despite the increased availability of imaging modalities, missed diagnosis also resulted in substantial pay outs.


Assuntos
Artroplastia do Joelho/legislação & jurisprudência , Responsabilidade Legal/economia , Imperícia/legislação & jurisprudência , Ortopedia/legislação & jurisprudência , Artroplastia do Joelho/economia , Custos e Análise de Custo , Humanos , Imperícia/economia , Ortopedia/economia , Medicina Estatal , Reino Unido
10.
Bone Joint J ; 97-B(4): 484-91, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25820886

RESUMO

In this in vitro study of the hip joint we examined which soft tissues act as primary and secondary passive rotational restraints when the hip joint is functionally loaded. A total of nine cadaveric left hips were mounted in a testing rig that allowed the application of forces, torques and rotations in all six degrees of freedom. The hip was rotated throughout a complete range of movement (ROM) and the contributions of the iliofemoral (medial and lateral arms), pubofemoral and ischiofemoral ligaments and the ligamentum teres to rotational restraint was determined by resecting a ligament and measuring the reduced torque required to achieve the same angular position as before resection. The contribution from the acetabular labrum was also measured. Each of the capsular ligaments acted as the primary hip rotation restraint somewhere within the complete ROM, and the ligamentum teres acted as a secondary restraint in high flexion, adduction and external rotation. The iliofemoral lateral arm and the ischiofemoral ligaments were primary restraints in two-thirds of the positions tested. Appreciation of the importance of these structures in preventing excessive hip rotation and subsequent impingement/instability may be relevant for surgeons undertaking both hip joint preserving surgery and hip arthroplasty.


Assuntos
Acetábulo/fisiologia , Articulação do Quadril/fisiologia , Quadril/fisiologia , Ligamentos Articulares/fisiologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Cartilagem Articular/fisiologia , Feminino , Fibrocartilagem/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Rotação , Torque
11.
Physiol Meas ; 35(5): N29-40, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24711048

RESUMO

Measuring gait asymmetry is an important feature when characterizing functional imbalance between limbs. This could be due to pathologies, such as osteoarthritis, stroke, or associated with the effects of surgeries such as hip arthroplasty. Generally, the study of asymmetry or imbalance has required the use of a gait lab or force plates, which could be expensive and difficult to use in home settings. This work validates the use of a light weight ear sensor (7.4 g) with an instrumented treadmill for 64 subjects (age (60.04 (15.36)) including healthy subjects (14) as well as subjects who had been treated for hip (17), knee-replacement surgery (21) and knee osteoarthritis (12). Subjects performed treadmill walking at several speeds on flat surfaces, inclines and declines. Accelerometer data from the ear sensor were segmented into consecutive steps and temporal features were extracted. The measures of gait cycle time and step-period asymmetry obtained from the ear sensor matched well those of the treadmill for flat surfaces, inclines and declines. The key implication of the study is that the proposed method could replace expensive equipment for monitoring temporal gait features in clinics as well as free-living environments, which is important for monitoring rehabilitation after surgery and the progress of diseases affecting limb imbalance.


Assuntos
Orelha , Marcha/fisiologia , Monitorização Fisiológica/instrumentação , Adulto , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/fisiopatologia , Fatores de Tempo
12.
Bone Joint J ; 95-B(10): 1326-31, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24078527

RESUMO

Orientation of the acetabular component influences wear, range of movement and the incidence of dislocation after total hip replacement (THR). During surgery, such orientation is often referenced to the anterior pelvic plane (APP), but APP inclination relative to the coronal plane (pelvic tilt) varies substantially between individuals. In contrast, the change in pelvic tilt from supine to standing (dPT) is small for nearly all individuals. Therefore, in THR performed with the patient supine and the patient's coronal plane parallel to the operating table, we propose that freehand placement of the acetabular component placement is reliable and reflects standing (functional) cup position. We examined this hypothesis in 56 hips in 56 patients (19 men) with a mean age of 61 years (29 to 80) using three-dimensional CT pelvic reconstructions and standing lateral pelvic radiographs. We found a low variability of acetabular component placement, with 46 implants (82%) placed within a combined range of 30° to 50° inclination and 5° to 25° anteversion. Changing from the supine to the standing position (analysed in 47 patients) was associated with an anteversion change < 10° in 45 patients (96%). dPT was < 10° in 41 patients (87%). In conclusion, supine THR appears to provide reliable freehand acetabular component placement. In most patients a small reclination of the pelvis going from supine to standing causes a small increase in anteversion of the acetabular component.


Assuntos
Acetábulo/patologia , Artroplastia de Quadril/métodos , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/fisiopatologia , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Orientação , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia , Decúbito Dorsal/fisiologia , Tomografia Computadorizada por Raios X
13.
Bone Joint J ; 95-B(6): 861, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23723286

RESUMO

We welcome letters to the Editor concerning articles that have recently been published. Such letters will be subject to the usual stages of selection and editing; where appropriate the authors of the original article will be offered the opportunity to reply.


Assuntos
Artroplastia de Quadril/métodos , Cimentação , Fraturas do Colo Femoral/cirurgia , Feminino , Humanos , Masculino
14.
Bone Joint J ; 95-B(3): 314-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23450013

RESUMO

We examined the relationship between the size of the femoral cam in femoroacetabular impingement (FAI) and acetabular pathomorphology to establish if pincer impingement exists in patients with a femoral cam. CT scans of 37 symptomatic impinging hips with a femoral cam were analysed in a three-dimensional study and were compared with 34 normal hips. The inclination and version of the acetabulum as well as the acetabular rim angle and the bony acetabular coverage were calculated. These measurements were correlated with the size and shape of the femoral cams. While the size of the femoral cam varied characteristically, the acetabular morphology of the two groups was similar in terms of version (normal mean 23° (sd 7°); cam mean 22° (sd 9°)), inclination (normal mean 57° (sd 5°); cam mean 56° (sd 5°)), acetabular coverage (normal mean 41% (sd 5%); cam mean 42% (sd 4%)) and the mean acetabular rim angle (normal mean 82° (sd 5°); cam mean 83° (sd 4°)). We found no correlation between acetabular morphology and the severity of cam lesion and no evidence of either global or focal over-coverage to support the diagnosis of 'mixed' FAI. The femoral cam may provoke edge loading but removal of any acetabular bearing surface when treating cam FAI might induce accelerated wear.


Assuntos
Acetábulo/patologia , Impacto Femoroacetabular/patologia , Cabeça do Fêmur/patologia , Acetábulo/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Impacto Femoroacetabular/diagnóstico por imagem , Cabeça do Fêmur/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Modelos Lineares , Masculino , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
15.
J Biomech ; 45(9): 1698-704, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22513086

RESUMO

The impact of anatomical variation and surgical error on excessive wear and loosening of the acetabular component of large diameter metal-on-metal hip arthroplasties was measured using a multi-factorial analysis through 112 different simulations. Each surgical scenario was subject to eight different daily loading activities using finite element analysis. Excessive wear appears to be predominantly dependent on cup orientation, with inclination error having a higher influence than version error, according to the study findings. Acetabular cup loosening, as inferred from initial implant stability, appears to depend predominantly on factors concerning the area of cup-bone contact, specifically the level of cup seating achieved and the individual patient's anatomy. The extent of press fit obtained at time of surgery did not appear to influence either mechanism of failure in this study.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Falha de Prótese , Adulto , Idoso , Simulação por Computador , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Teste de Materiais , Erros Médicos , Metais , Pessoa de Meia-Idade
16.
J Bone Joint Surg Br ; 93(7): 881-5, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21705557

RESUMO

Large-head metal-on-metal total hip replacement has a failure rate of almost 8% at five years, three times the revision rate of conventional hip replacement. Unexplained pain remains a feature of this type of arthroplasty. All designs of the femoral component of large-head metal-on-metal total hip replacements share a unique characteristic: a subtended angle of 120° defining the proportion of a sphere that the head represents. Using MRI, we measured the contact area of the iliopsoas tendon on the femoral head in sagittal reconstruction of 20 hips of patients with symptomatic femoroacetabular impingement. We also measured the articular extent of the femoral head on 40 normal hips and ten with cam-type deformities. Finally, we performed virtual hip resurfacing on normal and cam-type hips, avoiding overhang of the metal rim inferomedially. The articular surface of the femoral head has a subtended angle of 120° anteriorly and posteriorly, but only 100° medially. Virtual surgery in a normally shaped femoral head showed a 20° skirt of metal protruding medially where iliopsoas articulates. The excessive extent of the large-diameter femoral components may cause iliopsoas impingement independently of the acetabular component. This may be the cause of postoperative pain with these implants.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/patologia , Prótese de Quadril/efeitos adversos , Dor Pós-Operatória/etiologia , Músculos Psoas/patologia , Colo do Fêmur/patologia , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Anatômicos , Dor Pós-Operatória/patologia , Desenho de Prótese , Tomografia Computadorizada por Raios X/métodos
17.
J Bone Joint Surg Br ; 93(5): 629-33, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21511928

RESUMO

We studied the intra- and interobserver reliability of measurements of the position of the components after total knee replacement (TKR) using a combination of radiographs and axial two-dimensional (2D) and three-dimensional (3D) reconstructed CT images to identify which method is best for this purpose. A total of 30 knees after primary TKR were assessed by two independent observers (an orthopaedic surgeon and a radiologist) using radiographs and CT scans. Plain radiographs were highly reliable at measuring the tibial slope, but showed wide variability for all other measurements; 2D-CT also showed wide variability. 3D-CT was highly reliable, even when measuring rotation of the femoral components, and significantly better than 2D-CT. Interobserver variability in the measurements on radiographs were good (intraclass correlation coefficient (ICC) 0.65 to 0.82), but rotational measurements on 2D-CT were poor (ICC 0.29). On 3D-CT they were near perfect (ICC 0.89 to 0.99), and significantly more reliable than 2D-CT (p < 0.001). 3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components. Rotational measurements in particular should be performed on 3D-reconstructed CT images. When faced with a poorly functioning TKR with concerns over component positioning, we recommend 3D-CT as the investigation of choice.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Articulação do Joelho/patologia , Articulação do Joelho/fisiopatologia , Pessoa de Meia-Idade , Variações Dependentes do Observador , Orientação , Cuidados Pós-Operatórios/métodos , Amplitude de Movimento Articular , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
18.
Ann R Coll Surg Engl ; 90(8): W6-8, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18990275

RESUMO

Klippel-Trenaunay syndrome patients often suffer degenerative joint disease at an early age. Performing arthroplasty in these patients is particularly difficult for a number of reasons. In this case report, we describe the second reported case of total hip replacement in Klippel-Trenaunay syndrome, using novel techniques to surmount the problems faced in this challenging condition.


Assuntos
Artralgia/cirurgia , Artroplastia de Quadril , Síndrome de Klippel-Trenaunay-Weber/complicações , Adulto , Artralgia/etiologia , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue Autóloga , Feminino , Humanos
19.
J Bone Joint Surg Br ; 90(8): 1032-8, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18669958

RESUMO

The rotational alignment of the tibia is an unresolved issue in knee replacement. A poor functional outcome may be due to malrotation of the tibial component. Our aim was to find a reliable method for positioning the tibial component in knee replacement. CT scans of 19 knees were reconstructed in three dimensions and orientated vertically. An axial plane was identified 20 mm below the tibial spines. The centre of each tibial condyle was calculated from ten points taken round the condylar cortex. The tibial tubercle centre was also generated as the centre of the circle which best fitted eight points on the outside of the tubercle in an axial plane at the level of its most prominent point. The derived points were identified by three observers with errors of 0.6 mm to 1 mm. The medial and lateral tibial centres were constant features (radius 24 mm (SD 3), and 22 mm (SD 3), respectively). An anatomical axis was created perpendicular to the line joining these two points. The tubercle centre was found to be 20 mm (SD 7) lateral to the centre of the medial tibial condyle. Compared with this axis, an axis perpendicular to the posterior condylar axis was internally rotated by 6 degrees (SD 3). An axis based on the tibial tubercle and the tibial spines was also internally rotated by 5 degrees (sd 10). Alignment of the knee when based on this anatomical axis was more reliable than either the posterior surfaces or any axis involving the tubercle which was the least reliable landmark in the region.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Tíbia/fisiologia , Adulto , Idoso , Artroplastia do Joelho/normas , Mau Alinhamento Ósseo/prevenção & controle , Feminino , Humanos , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Rotação , Tíbia/anatomia & histologia , Tíbia/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Suporte de Carga/fisiologia
20.
Nucleic Acids Res ; 36(Web Server issue): W352-7, 2008 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-18544607

RESUMO

The Gene Ontology (GO) vocabulary has been extensively explored to analyze the functions of coexpressed genes. However, despite its extended use in Biology and Medical Sciences, there are still high levels of uncertainty about which ontology (i.e. Molecular Process, Cellular Component or Molecular Function) should be used, and at which level of specificity. Moreover, the GO database can contain incomplete information resulting from human annotations, or highly influenced by the available knowledge about a specific branch in an ontology. In spite of these drawbacks, there is a trend to ignore these problems and even use GO terms to conduct searches of gene expression profiles (i.e. expression + GO) instead of more cautious approaches that just consider them as an independent source of validation (i.e. expression versus GO). Consequently, propagating the uncertainty and producing biased analysis of the required gene grouping hypotheses. We proposed a web tool, Onto-CC, as an automatic method specially suited for independent explanation/validation of gene grouping hypotheses (e.g. coexpressed genes) based on GO clusters (i.e. expression versus GO). Onto-CC approach reduces the uncertainty of the queries by identifying optimal conceptual clusters that combine terms from different ontologies simultaneously, as well as terms defined at different levels of specificity in the GO hierarchy. To do so, we implemented the EMO-CC methodology to find clusters in structural databases [GO Directed acyclic Graph (DAG) tree], inspired on Conceptual Clustering algorithms. This approach allows the management of optimal cluster sets as potential parallel hypotheses, guided by multiobjective/multimodal optimization techniques. Therefore, we can generate alternative and, still, optimal explanations of queries that can provide new insights for a given problem. Onto-CC has been successfully used to test different medical and biological hypotheses including the explanation and prediction of gene expression profiles resulting from the host response to injuries in the inflammatory problem. Onto-CC provides two versions: Ready2GO, a precalculated EMO-CC for several genomes and an Advanced Onto-CC for custom annotation files (http://gps-tools2.wustl.edu/onto-cc/index.html).


Assuntos
Perfilação da Expressão Gênica , Software , Vocabulário Controlado , Análise por Conglomerados , Genes/fisiologia , Internet , Análise de Sequência com Séries de Oligonucleotídeos , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...