Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Transl Gastroenterol ; 13(10): e00526, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36007177

RESUMO

INTRODUCTION: Continuous left ventricular assist devices (LVADs) offer hemodynamic support in advanced and decompensated heart failure but are often complicated by gastrointestinal bleeding (GIB) in medically fragile patients. METHODS: We performed a retrospective analysis of 475 consecutive patients who underwent LVAD implantation at the Massachusetts General Hospital and Tufts Medical Center from 2008 to 2019 and identified 128 patients with clinically significant GIB. Clinical characteristics of each bleeding event, including procedures and interventions, were recorded. We examined LVAD patients with overt and occult presentations to determine diagnostic endoscopic yield and analyzed predictors of recurrent GIB. RESULTS: We identified 128 unique patients with LVAD implantation complicated by GIB. No significant difference was observed based on study center, underlying cardiomyopathy, race/ethnicity, serum indices, and medications used. Overt bleeders presented more commonly during LVAD implantation admission ( P = 0.001) than occult bleeders. Occult bleed presentations had only 1 lower and no middle GI bleed source identified, despite similar workups to overt bleeds. Destination therapy (e.g., among nontransplant candidates) LVAD implantation (odds ratio 2.38, 95% confidence interval 1.05-5.58) and a history of GIB (odds ratio 3.85, 95% confidence interval 1.29-12.7) were independently associated with an increased risk of recurrent GIB-related hospitalization. DISCUSSION: Our findings confirm a high rate of GIB, especially in destination LVAD patients, and show a low diagnostic yield for colonoscopy and middle GI bleed assessments in LVAD patients with occult bleeds. Overt bleeding was more common and associated with vascular malformations. Although endoscopic interventions stopped active hemorrhage, GIB often recurred.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Hemodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...