Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Nervenarzt ; 94(12): 1123-1128, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37594495

RESUMO

Magnetic resonance imaging (MRI) is of exceptional importance in the diagnostics and monitoring of multiple sclerosis (MS); however, a close interdisciplinary cooperation between neurologists in private practice, (neuro)radiological practices, hospitals or specialized MS centers is only rarely established. In particular, there is a lack of standardized MRI protocols for image acquisition as well as established quality parameters, which guarantee the comparability of MRI records; however, this is a fundamental prerequisite for an effective application of MRI in the treatment of MS patients, e.g., for making the diagnosis or treatment monitoring. To address these challenges a group of neurologists and (neuro)radiologists developed a consensus proposal for standardization of image acquisition, interpretation and transmission of results and for improvement in interdisciplinary cooperation. This pilot project in the metropolitan area of Essen used a modified Delphi process and was based on the most up to date scientific knowledge. The recommendation takes the medical, economic, temporal and practical aspects of MRI in MS into consideration. The model of interdisciplinary cooperation between radiologists and neurologists with the aim of a regional standardization of MRI could serve as an example for other regions of Germany in order to optimize MRI for MS.


Assuntos
Esclerose Múltipla , Humanos , Esclerose Múltipla/diagnóstico , Consenso , Projetos Piloto , Imageamento por Ressonância Magnética/métodos , Neurologistas
2.
Surg Endosc ; 32(1): 166-174, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28643076

RESUMO

BACKGROUND: Although recent data are contradictory, it is still claimed that Pressurized Intra-Peritoneal Aerosol Chemotherapy (PIPAC) would deliver an aerosol which distributes homogeneously throughout the entire abdominal cavity. METHODS: 99mTc-Pertechnetat was administered in four postmortem swine using either PIPAC or liquid intra-peritoneal chemotherapy (IPC). The animals were examined by planar scintigraphy and SPECT/CT. Planar distribution images were divided into four regions of interest (ROIs: right/left upper and lower abdominal quadrant). SPECT/CT slices were scanned for areas of intense nuclide accumulation ("hot spots"). The percentage of relative distribution for planar scintigraphy was calculated by dividing the summed individual counts of each ROI by total counts measured in the entire abdominal cavity. The relative distribution of the "hot spots" was analyzed by dividing the counts of the local volume of interest (VOI) by the summed volume counts measured in the entire abdominal cavity. RESULTS: In all four animals, planar scintigraphy showed inhomogeneous nuclide distribution. After PIPAC only 8-10% of the delivered nuclide was detected in one ROI with a mean deviation of 40% and 74% from a uniform nuclide distribution pattern. In all animals, SPECT/CT revealed "hot spots" beneath the PIPAC Micropump, catheter tip, and in the cul-de-sac region which comprise about 25% of the total amount of delivered nuclide in 2.5% of the volume of the entire abdominal cavity. CONCLUSIONS: Our present data indicate that the intra-abdominal aerosol distribution pattern of PIPAC therapy is non-homogeneous and that the currently applied technology has still not overcome the problem of inhomogeneous drug distribution of IPC.


Assuntos
Antineoplásicos/administração & dosagem , Peritônio/diagnóstico por imagem , Pertecnetato Tc 99m de Sódio/farmacocinética , Aerossóis/farmacocinética , Animais , Antineoplásicos/farmacocinética , Infusões Parenterais/métodos , Peritônio/metabolismo , Cintilografia/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Suínos , Distribuição Tecidual
3.
Nuklearmedizin ; 56(3): 73-81, 2017 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-28401244

RESUMO

AIM: Evaluate the diagnostic accuracy of 68Ga-labeled HBED-CC-PSMA-PET/MRI for detection of recurrent PCa in comparison to PET/CT. METHODS: 48 patients with suspected recurrent PCa underwent PET/CT after injection of the 68Ga-HBED-CC-PSMA ligand followed by integrated PET/MRI. Image analysis was performed by nuclear medicine physicians and radiologists with respect to the detection of lymph node metastases, bone metastases and local recurrence of the tumour. Image quality was evaluated visually based on a three-point ordinal scale. RESULTS: From 48 patients initially examined, 25 were finally eligible for qualitative and quantitative image evaluation. In 14 patients, neither PET/CT nor PET/MRI found tumour lesions, and 9 patients were excluded from image analysis due to a pronounced extinction artifact around the urinary bladder (halo). In comparison to 68Ga-HBED-CC-PSMA-PET/CT, 68Ga-HBED-CC-PSMA-PET/MRI identified 14 vs. 9 local recurrences in the prostate bed and 23 vs. 20 PET-positive lymph nodes, and 4 vs. 4 PET-positive bone lesions, respectively. While the improved detection of suspicious lymph nodes was primarily attributable to the PET component, the advantageous detection of tumour recurrences in the prostate bed was chiefly referable to the superior soft-tissue contrast of the MR component of integrated PET/MRI. Analysis of SUVmax revealed that 68Ga-HBED-CC-PSMA-PET/MRI provided significantly higher SUVmax compared to 68Ga-HBED-CC-PSMA-PET/CT (17.6, range 2.0-49.6, and 15.1, range 3.5-36.8, respectively, p = 0.0019). CONCLUSION: 68Ga-HBED-CC-PSMA-PET/MRI was found to be superior as compared to 68Ga-HBED-CC-PSMA-PET/CT in the detection of PSMA-expressing prostate bed recurrences.


Assuntos
Ácido Edético/análogos & derivados , Glutamato Carboxipeptidase II/farmacocinética , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Antígenos de Superfície , Meios de Contraste , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/metabolismo , Neoplasias da Próstata/metabolismo , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Clin Nucl Med ; 42(1): 20-25, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27846003

RESUMO

PURPOSE: The prostate-specific membrane antigen (PSMA) was shown to be overexpressed on the neovasculature of several malignancies. Here, the role of Ga-HBED-CC-PSMA PET/CT for the detection of PSMA expression in patients with metastasized differentiated thyroid cancer (DTC) was evaluated. METHODS: Six patients with iodine-negative and F-FDG-positive metastasized DTC (mean TG, 1616 ng/mL) received 71-93 MBq of the Ga-labeled PSMA ligand and underwent PET/CT at 62 ± 7 minutes p.i.. Tumor accumulation capacity of the tracer and the detection rate of local recurrences and metastases were compared with F-FDG. Tracer uptake was quantified in terms of the SUVmax. RESULTS: In 5 of 6 patients, sites of putative metastatic disease could be identified using Ga-HBED-CC-PSMA PET/CT. All lesions detected with Ga-HBED-CC-PSMA PET/CT (n = 42) were confirmed by F-FDG PET/CT or conventional CT imaging. Using Ga-HBED-CC-PSMA PET/CT, all tumor lesions identified with F-FDG PET/CT imaging could be visualized in 3 of 5 patients. In 2 patients, only the most prominent lesions detected with F-FDG PET/CT imaging were visualized by Ga-HBED-CC-PSMA PET/CT. Ga-HBED-CC-PSMA uptake ranged from low in 1 patient (mean SUVmax 3.3) to intermediate (1 patient; mean SUVmax, 6.1) to intense (3 patients; mean SUVmax, 12.8, 16.2, and 18.3). The highest SUVmax values were observed for a bone lesion, reaching 39.7. CONCLUSIONS: These preliminary results indicate that Ga-HBED-CC-PSMA PET/CT might be suitable for staging of patients with metastasized DTC. Ga-HBED-CC-PSMA PET/CT could be useful for the identification of patients who might qualify for PSMA-targeted radionuclide therapy because of high PSMA uptake.


Assuntos
Compostos Organometálicos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Ácido Edético/análogos & derivados , Feminino , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Oligopeptídeos , Neoplasias da Glândula Tireoide/patologia
5.
Neurol Neurochir Pol ; 47(1): 32-42, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23487292

RESUMO

BACKGROUND AND PURPOSE: New angiographic devices with flat panel detectors allow cross-sectional imaging within the angiographic suite. In patients receiving external ventricular drainage (EVD) to manage hydrocephalus following subarachnoid haemorrhage (SAH), these may help evaluating the position of an EVD without moving the patient to a conventional computed tomography (CT) scanner. It could facilitate patients' management in a life-threatening status. This study therefore compares conventional CT with post-interventional flat panel detector angiographic CT (FDCT) referring to the determinability of an accurate EVD position. MATERIAL AND METHODS: Twenty patients with SAH received FDCT and conventional CT for primary assessment after EVD insertion. Three single-blinded raters compared both modalities and evaluated the image sufficiency for determining the EVD position, EVD tip, intracranial course and whether a contorted drainage tube could be detected. RESULTS: FDCT was sufficient to detect a correct EVD position in 82.5% of the cases vs. 100% in conventional CT. Regarding the EVD tip, FDCT delivered at least 'good' results in 82.5% vs. 95% in conventional CT data. Determining the EVD intracranial course, FDCT provided at least 'good' data in 92.5% vs. 100% in conventional CT. For detecting tube contortion, FDCT provided at least 'good' results in 70% vs. 98% in conventional CT. CONCLUSIONS: FDCT is a promising method to determine the correct position of an EVD in patients with SAH. Following a neuroradiological intervention, it facilitates the patients' management and renders additional transfers to conventional CT unnecessary in the majority of cases.


Assuntos
Angiografia Cerebral/métodos , Drenagem/métodos , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/cirurgia , Tomografia Computadorizada por Raios X/enfermagem , Ventriculostomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos de Viabilidade , Feminino , Humanos , Hidrocefalia/etiologia , Masculino , Pessoa de Meia-Idade , Hemorragia Subaracnóidea/complicações , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/cirurgia , Tomografia Computadorizada por Raios X/métodos
6.
Acta Neurochir (Wien) ; 153(3): 533-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21210161

RESUMO

BACKGROUND: Implantation of 1,3-bis (2-chloroethyl)-1-nitrosourea (BCNU) wafer for malignant glioma is not recommended in the case of surgical opening of the ventricular system during microsurgical tumor resection because the wafer material may dislocate from the resection cavity into the ventricular system and cause obstructive hydrocephalus. TachoSil is an adhesive collagen fleece used in different surgical disciplines that provides an air- and liquid-tight seal closing communications between the ventricular system and the resection cavity after tumor removal. METHODS: Occlusion of ventricular defects with TachoSil after microsurgical glioma resection was performed in two patients with newly diagnosed and seven patients with recurrent malignant glioma prior to BCNU wafer implantation into the resection cavity. Early postoperative cranial computed tomography (CCT)/MRI and follow-up MRI at 3 months' intervals were performed with a median follow-up of 10.4 months. RESULTS: The collagen fleece was identified as a linear structure hypodense/hypointense to white matter on postoperative CT/MRI separating the resection cavity from the ventricular lumen in all cases. In no case did early CCT/MRI or follow-up MRI reveal wafer material within the ventricular system. In no case did signs of obstructive hydrocephalus occur. CONCLUSION: Sealing of the ventricular system using a fibrinogen-coated collagen fleece effectively separates the resection cavity from the ventricular system and allows implantation of BCNU wafers into the resection cavity. No morphological evidence for wafer material dislocation into the ventricular system or obstruction of CSF pathways was found in nine patients who received 41 follow-up MRI over 10.4 months of follow-up.


Assuntos
Antineoplásicos Alquilantes/administração & dosagem , Astrocitoma/tratamento farmacológico , Astrocitoma/cirurgia , Neoplasias Encefálicas/cirurgia , Carmustina/administração & dosagem , Neoplasias do Ventrículo Cerebral/tratamento farmacológico , Neoplasias do Ventrículo Cerebral/cirurgia , Implantes de Medicamento , Fibrinogênio , Glioblastoma/cirurgia , Microcirurgia/métodos , Recidiva Local de Neoplasia/cirurgia , Tampões de Gaze Cirúrgicos , Trombina , Ventriculostomia/métodos , Adulto , Idoso , Neoplasias Encefálicas/tratamento farmacológico , Quimioterapia Adjuvante , Terapia Combinada , Combinação de Medicamentos , Feminino , Seguimentos , Glioblastoma/tratamento farmacológico , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/tratamento farmacológico , Complicações Pós-Operatórias/diagnóstico , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...