Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Clin Transl Radiat Oncol ; 16: 60-66, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31032432

RESUMO

AIMS: In patients undergoing locoregional radiotherapy (RT) for breast cancer including the internal mammary chain (IMC), VMAT has been shown to be superior to tangential-field radiotherapy in terms of target coverage and minimising dose to heart and lungs. In this study we describe and validate organ motion-based robust optimisation for generating breast and locoregional lymph node VMAT plans that are robust to inter-fractional changes. MATERIALS AND METHODS: In this retrospective study of five patients with left-sided breast cancer requiring locoregional breast radiotherapy including the IMC, non-robust plans were generated in the nominal scenario (planning-CT) and corresponding robust plans were created by optimising over a range of simulated CTs representing worst-case scenario shape changes to the breast. Both plans were re-calculated on CBCT images (n = 67) acquired prior to RT to generate estimates of delivered fractional dose. Plan robustness to inter-fractional changes was assessed in terms of the estimated target coverage and OAR dose. RESULTS: Organ motion-based robust optimisation was able to generate clinically acceptable treatment plans in the nominal scenario on the planning CT with no significant differences to OAR dose between the robust and non-robust planning techniques. All plans (robust and non-robust) achieved the mandatory target coverage requirements. Estimates of delivered dose demonstrated a significant improvement in breast target coverage for the robust plans compared to non-robust plans. For the breast CTV, 92% of the robust plans achieved the optimal D98% > 95% clinical goal as compared to 71% of the non-robust plans (p < 0.01). 94% of robust plans achieved acceptable superficial breast coverage, as compared to 55% for the non-robust technique. CONCLUSIONS: Organ motion-based robust optimisation VMAT is able to produce clinically acceptable organ-at-risk sparing plans for locoregional breast radiotherapy (including the IMC) that are robust to inter-fractional changes, therefore reducing the likelihood of reactive adaptive re-planning.

2.
J Appl Clin Med Phys ; 18(1): 18-24, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28291912

RESUMO

OBJECTIVES: To reduce treatment planning times while maintaining plan quality through the introduction of semi-automated planning techniques for breast radiotherapy. METHODS: Automatic critical structure delineation was examined using the Smart Probabilistic Image Contouring Engine (SPICE) commercial autosegmentation software (Philips Radiation Oncology Systems, Fitchburg, WI) for a cohort of ten patients. Semiautomated planning was investigated by employing scripting in the treatment planning system to automate segment creation for breast step-and-shoot planning and create objectives for segment weight optimization; considerations were made for three different multileaf collimator (MLC) configurations. Forty patients were retrospectively planned using the script and a planning time comparison performed. RESULTS: The SPICE heart and lung outlines agreed closely with clinician-defined outlines (median Dice Similarity Coefficient > 0.9); median difference in mean heart dose was 0.0 cGy (range -10.8 to 5.4 cGy). Scripted treatment plans demonstrated equivalence with their clinical counterparts. No statistically significant differences were found for target parameters. Minimal ipsilateral lung dose increases were also observed. Statistically significant (P < 0.01) time reductions were achievable for MLCi and Agility MLC (Elekta Ltd, Crawley, UK) plans (median 4.9 and 5.9 min, respectively). CONCLUSIONS: The use of commercial autosegmentation software enables breast plan adjustment based on doses to organs at risk. Semi-automated techniques for breast radiotherapy planning offer modest reductions in planning times. However, in the context of a typical department's breast radiotherapy workload, minor savings per plan translate into greater efficiencies overall.


Assuntos
Neoplasias da Mama/radioterapia , Órgãos em Risco/efeitos da radiação , Aceleradores de Partículas/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Automação , Feminino , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Software
3.
Radiother Oncol ; 120(2): 356-62, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27222296

RESUMO

BACKGROUND AND PURPOSE: Magnetic resonance (MR) and computed tomography (CT) images are degraded in the presence of metallic implants. We investigate whether SEMAC (Slice Encoding for Metal Artifact Correction) MR is advantageous for radiotherapy (RT) planning. METHODS: Conventional and SEMAC MR protocols were compared (1.5T). A spine fixation device suspended in gelatine, two patients with spine fixation devices and six patients with bilateral hip replacements were scanned with both conventional and SEMAC protocols. In spine patients the visibility of the spinal canal and spinal cord was assessed; in prostate patients, the visibility of the prostate, pelvic structures and the pelvic girdle. RESULTS: The signal loss volume surrounding the spine fixation device was reduced by approximately 20% when the SEMAC protocol was employed, and registration errors were reduced. For spine patients, the spinal canal was completely visible only using the SEMAC protocol. In hip replacement patients, metal artifacts were local; the signal loss extended to the internal surface of the acetabulum in eight implants with conventional protocols, but only in four using SEMAC. CONCLUSIONS: SEMAC MR contributes towards correct co-registration of MR and CT images for RT planning, and is particularly relevant when the TV or OARs are close to implants.


Assuntos
Imageamento por Ressonância Magnética/métodos , Próteses e Implantes , Planejamento da Radioterapia Assistida por Computador/métodos , Artefatos , Fixação Interna de Fraturas/instrumentação , Humanos , Aumento da Imagem , Masculino , Metais , Neoplasias da Próstata/radioterapia , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
Br J Radiol ; 88(1054): 20150309, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26268141

RESUMO

OBJECTIVE: To evaluate breath-hold stability and constancy for a voluntary breath-hold (VBH) technique in a retrospective analysis. METHODS: Movie loop sequences of electronic portal image data from multiple breath holds in a cohort of 19 patients were used to assess within and between breath-hold stability. In vivo dosimetry data based on electronic portal imaging (EPI) were analysed for 31 VBH patients plus a cohort of free-breathing (FB) patients to provide a reference. A phantom experiment simulated the impact on dose of FB, breath hold and unplanned release of breath hold. RESULTS: 165/174 (93%) movie loop data sets had no detectable displacement. For the remaining 12, median displacement = 1.5 mm and maximum displacement = 3 mm (one patient on one fraction). In vivo dosimetry data analysis showed a median dose difference measured to planned of -0.2% (VBH) and -0.1% (FB). Dose distribution evaluation (γ) pass rates were 84% (VBH) and 91% (FB) including the lung region; 93% and 96% with a lung override. Unplanned release of phantom breath-hold position changed median dose by ≤1% and degraded γ pass rates to 79-62%. Failing regions were mostly in the periphery of the treated volume. CONCLUSION: The data confirmed that multiple VBHs using visual monitoring are stable; in vivo dose verification via EPI was within expected and acceptable levels. ADVANCES IN KNOWLEDGE: These data provide further reassurance that VBH is a safe technique for cardiac sparing breast radiotherapy and support its rapid, widespread implementation.


Assuntos
Neoplasias da Mama/radioterapia , Suspensão da Respiração , Dosagem Radioterapêutica , Estudos de Coortes , Feminino , Humanos , Imagens de Fantasmas , Respiração , Estudos Retrospectivos , Gravação de Videoteipe
5.
Radiother Oncol ; 114(1): 66-72, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25739317

RESUMO

PURPOSE: To compare mean heart and left anterior descending coronary artery (LAD) doses (NTDmean) and positional reproducibility in larger-breasted women receiving left breast radiotherapy using supine voluntary deep-inspiratory breath-hold (VBH) and free-breathing prone techniques. MATERIALS AND METHODS: Following surgery for early breast cancer, patients with estimated breast volumes >750 cm(3) underwent planning-CT scans in supine VBH and free-breathing prone positions. Radiotherapy treatment plans were prepared, and mean heart and LAD doses were calculated. Patients were randomised to receive one technique for fractions 1-7, before switching techniques for fractions 8-15 (40 Gy/15 fractions total). Daily electronic portal imaging and alternate-day cone-beam CT (CBCT) imaging were performed. The primary endpoint was the difference in mean LAD NTDmean between techniques. Population systematic (Σ) and random errors (σ) were estimated. Within-patient comparisons between techniques used Wilcoxon signed-rank tests. RESULTS: 34 patients were recruited, with complete dosimetric data available for 28. Mean heart and LAD NTDmean doses for VBH and prone treatments respectively were 0.4 and 0.7 (p<0.001) and 2.9 and 7.8 (p<0.001). Clip-based CBCT errors for VBH and prone respectively were ⩽3.0 mm and ⩽6.5 mm (Σ) and ⩽3.5 mm and ⩽5.4 mm (σ). CONCLUSIONS: In larger-breasted women, supine VBH provided superior cardiac sparing and reproducibility than a free-breathing prone position.


Assuntos
Neoplasias da Mama/radioterapia , Suspensão da Respiração , Adulto , Idoso , Neoplasias da Mama/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Vasos Coronários/efeitos da radiação , Feminino , Coração/efeitos da radiação , Humanos , Mastectomia Segmentar/métodos , Pessoa de Meia-Idade , Posicionamento do Paciente/métodos , Decúbito Ventral , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sarcoma/etiologia , Decúbito Dorsal , Tomografia Computadorizada por Raios X
6.
J Vis Exp ; (89)2014 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-25046661

RESUMO

Breath-holding techniques reduce the amount of radiation received by cardiac structures during tangential-field left breast radiotherapy. With these techniques, patients hold their breath while radiotherapy is delivered, pushing the heart down and away from the radiotherapy field. Despite clear dosimetric benefits, these techniques are not yet in widespread use. One reason for this is that commercially available solutions require specialist equipment, necessitating not only significant capital investment, but often also incurring ongoing costs such as a need for daily disposable mouthpieces. The voluntary breath-hold technique described here does not require any additional specialist equipment. All breath-holding techniques require a surrogate to monitor breath-hold consistency and whether breath-hold is maintained. Voluntary breath-hold uses the distance moved by the anterior and lateral reference marks (tattoos) away from the treatment room lasers in breath-hold to monitor consistency at CT-planning and treatment setup. Light fields are then used to monitor breath-hold consistency prior to and during radiotherapy delivery.


Assuntos
Neoplasias da Mama/radioterapia , Suspensão da Respiração , Cardiopatias/prevenção & controle , Lesões por Radiação/prevenção & controle , Planejamento da Radioterapia Assistida por Computador/métodos , Feminino , Coração/anatomia & histologia , Coração/efeitos da radiação , Cardiopatias/etiologia , Humanos , Radioterapia/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Radiother Oncol ; 108(2): 242-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23726115

RESUMO

PURPOSE: To determine whether voluntary deep-inspiratory breath-hold (v_DIBH) and deep-inspiratory breath-hold with the active breathing coordinator™ (ABC_DIBH) in patients undergoing left breast radiotherapy are comparable in terms of normal-tissue sparing, positional reproducibility and feasibility of delivery. METHODS: Following surgery for early breast cancer, patients underwent planning-CT scans in v_DIBH and ABC_DIBH. Patients were randomised to receive one technique for fractions 1-7 and the second technique for fractions 8-15 (40 Gy/15 fractions total). Daily electronic portal imaging (EPI) was performed and matched to digitally-reconstructed radiographs. Cone-beam CT (CBCT) images were acquired for 6/15 fractions and matched to planning-CT data. Population systematic (Σ) and random errors (σ) were estimated. Heart, left-anterior-descending coronary artery, and lung doses were calculated. Patient comfort, radiographer satisfaction and scanning/treatment times were recorded. Within-patient comparisons between the two techniques used the paired t-test or Wilcoxon signed-rank test. RESULTS: Twenty-three patients were recruited. All completed treatment with both techniques. EPI-derived Σ were ≤ 1.8mm (v_DIBH) and ≤ 2.0mm (ABC_DIBH) and σ ≤ 2.5mm (v_DIBH) and ≤ 2.2mm (ABC_DIBH) (all p non-significant). CBCT-derived Σ were ≤ 3.9 mm (v_DIBH) and ≤ 4.9 mm (ABC_DIBH) and σ ≤ 4.1mm (v_DIBH) and ≤ 3.8mm (ABC_DIBH). There was no significant difference between techniques in terms of normal-tissue doses (all p non-significant). Patients and radiographers preferred v_DIBH (p=0.007, p=0.03, respectively). Scanning/treatment setup times were shorter for v_DIBH (p=0.02, p=0.04, respectively). CONCLUSIONS: v_DIBH and ABC_DIBH are comparable in terms of positional reproducibility and normal tissue sparing. v_DIBH is preferred by patients and radiographers, takes less time to deliver, and is cheaper than ABC_DIBH.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Suspensão da Respiração/efeitos da radiação , Tomografia Computadorizada de Feixe Cônico , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Estudos de Avaliação como Assunto , Feminino , Seguimentos , Coração/efeitos da radiação , Humanos , Mastectomia Segmentar/métodos , Pessoa de Meia-Idade , Invasividade Neoplásica/patologia , Estadiamento de Neoplasias , Órgãos em Risco/efeitos da radiação , Posicionamento do Paciente , Dosagem Radioterapêutica , Radioterapia Adjuvante , Radioterapia Conformacional/métodos , Valores de Referência , Reprodutibilidade dos Testes , Medição de Risco , Estatísticas não Paramétricas , Resultado do Tratamento , Reino Unido
8.
Phys Med Biol ; 55(8): N201-10, 2010 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-20348610

RESUMO

The characteristics of an Elekta Precise treatment machine with a gating interface were investigated. Three detectors were used: a Farmer ionization chamber, a MatriXX ionization chamber array and an in-house, single pulse-measurement ionization chamber (IVC). Measurements were made of dosimetric accuracy, flatness and symmetry characteristics and duty cycle for a range of beam-on times and gating periods. Results were compared with a standard ungated delivery as a reference. For all beam-on times, down to 0.5 s, dosimetric differences were below +/-1% and flatness and symmetry parameter variations were below +/-1.5%. For the shorter beam-on times the in-house detector deviated from the other two detectors, suggesting that this device should be used in conjunction with other detectors for absolute dosimetry purposes. However, it was found to be useful for studying gated beam characteristics pulse by pulse.


Assuntos
Radioterapia/instrumentação , Radioterapia/métodos , Respiração , Tomografia Computadorizada Quadridimensional , Humanos , Movimento , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA