Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
3.
Cardiovasc Diagn Ther ; 12(3): 314-324, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35800353

RESUMO

Background: Quantitative flow ratio (QFR) may be used to assess the functional significance of coronary lesions. Only limited validation exists for this technology in the setting of severe aortic stenosis. Methods: A prospective study was performed on patients who were being considered for transcatheter aortic valve implantation. QFR analysis was performed (Medis Medical Imaging System, Leiden, The Netherlands) and compared to invasive measurements of haemodynamic assessment [fractional flow reserve (FFR), instantaneous wave-free ratio (iFR), diastolic pressure ratio during the wave-free period (dPR) and distal arterial pressure/arterial pressure (Pd/Pa)]. Results: A total of 35 patients were included in the study. Mean age was 75.5±6.5 and mean aortic valve gradient was 44.3±11.8 mmHg. There were 57 vessels analysed. The mean FFR was 0.83±0.10 and 22 vessels (39%) had a functionally significant FFR ≤0.80. QFR demonstrated a discriminatory power to predict functionally significant FFR [area under the receiver operating characteristic curve (AUC), 0.92; 95% confidence interval (CI): 0.84 to 1.00], representing a sensitivity of 73%, specificity of 91%, positive predictive value of 84%, negative predictive value of 84% and an accuracy of 84%. QFR also demonstrated a discriminatory power to predict functionally significant iFR ≤0.89 (AUC =0.92; 95% CI: 0.85 to 0.99), dPR ≤0.89 (AUC =0.90; 95% CI: 0.83 to 0.98) and Pd/Pa ≤0.92 (AUC =0.89; 95% CI: 0.80 to 0.97). Conclusions: QFR demonstrates acceptable diagnostic performance in patients with severe aortic stenosis when both FFR and non-hyperaemic pressure indices are used as reference standards.

4.
Cardiovasc Revasc Med ; 41: 47-52, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35131173

RESUMO

BACKGROUND: Instantaneous wave-free ratio (iFR) can reliably assess the physiological significance of coronary artery disease (CAD). Previous studies have demonstrated its interchangeability with other non-hyperaemic pressure ratios (NHPR), but there is no data exploring whether this association is maintained in patients with severe aortic stenosis (AS). METHODS: Forty-two patients (67 lesions) with severe AS were recruited and underwent invasive pressure-wire assessment. Data were extracted to calculate iFR, resting Pd/Pa, diastolic pressure ratios (DPR and dPR), and Diastolic Hyperaemia-Free Ratio (DFR). iFR was then compared with other NHPR to determine agreement and accuracy. RESULTS: Mean aortic gradient and dimensionless index were 44.3 ± 11.6 mmHg and 0.23 ± 0.04, respectively. Of the 67 vessels, 57% were LAD, 15% LCx, 13% RCA and 12% other. There was strong positive correlation between iFR and all other NHPR, including Pd/Pa (r = 0.91, p < 0.001), DPR (r = 0.99, p < 0.001), dPR (r = 0.97, p < 0.001) and DFR (r = 0.98, p < 0.001). While Bald-Altman analysis demonstrated that Pd/Pa and DFR were numerically different from iFR, ROC analyses demonstrated iFR ≤0.89 was accurately identified by all NHPRs; Pd/Pa (AUC = 0.965, 95% CI [0.928-0.994]), DPR (AUC = 1.000, 95% CI [1.000-1.000]), dPR (AUC = 0.974, 95% CI [0.937-1.000]), DFR (AUC = 0.989, 95% CI [0.968-1.000]). CONCLUSION: In patients with severe AS, all the included NHPR in this analysis accurately predicted iFR < 0.89. These data should reassure clinicians that use of alternative NHPR to iFR is reasonable when assessing the physiological significance of CAD in patients with severe AS.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença
5.
Eur Heart J Digit Health ; 3(4): 505-515, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36710902

RESUMO

Aims: Hyperaemic and non-hyperaemic pressure ratios (NHPR) are routinely used to identify significant coronary lesions. Machine learning (ML) techniques may help better understand these indices and guide future practice. This study assessed the ability of a purpose-built ML algorithm to classify coronary ischaemia during non-hyperaemia compared with the existing gold-standard technique (fractional flow reserve, FFR). Further, it investigated whether ML could identify components of coronary and aortic pressure cycles indicative of ischaemia. Methods and results: Seventy-seven coronary vessel lesions (39 FFR defined ischaemia, 53 patients) with proximal and distal non-hyperaemic pressure waveforms and FFR values were assessed using supervised and unsupervised learning techniques in combination with principal component analysis (PCA). Fractional flow reserve measurements were obtained from the right coronary artery (13), left anterior descending (46), left circumflex (11), left main (1), obtuse marginal (2), and diagonal (4). The most accurate supervised learning classification utilized whole-cycle aortic with diastolic distal blood pressure waveforms, yielding a classification accuracy of 86.9% (sensitivity 86.8%, specificity 87.2%, positive predictive value 86.8%, negative predictive value 87.2%). Principal component analysis showed subtle variations in coronary pressures at the start of diastole have significant relation to ischaemia, and whole-cycle aortic pressure data are important for determining ischaemia. Conclusions: Our ML algorithm classifies significant coronary lesions with accuracy similar to previous studies comparing time-domain NHPRs with FFR. Further, it has identified characteristics of pressure waveforms that relate to function. These results provide an application of ML to ischaemia requiring only standard data from non-hyperaemic pressure measurements.

6.
Indian J Thorac Cardiovasc Surg ; 37(3): 299-302, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33958838

RESUMO

There is a deficit of literature regarding the association between nickel allergy-induced symptoms and implanted devices. This report describes a case of nickel allergy causing debilitating migraine-like symptoms, failing to resolve with medical therapy, requiring surgical removal of the device and repair of the defect.

7.
Int J Cardiol ; 332: 143-147, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33775789

RESUMO

BACKGROUND: Patients with severe aortic stenosis (AS) exhibit systemic endothelial dysfunction, which can be associated with myocardial ischaemia in absence of obstructive coronary disease. Transcatheter aortic valve replacement (TAVR) is used to treat severe AS in patients with high or prohibitive surgical risk. However, it remains unknown whether endothelial function recovers post-TAVR. We therefore sought to assess the early and late changes in flow-mediated dilation (FMD), a measure of endothelial function, following TAVR. METHODS: Patients undergoing TAVR for severe AS had ultrasound assessment of brachial endothelial-independent and -dependent FMD. Measurements were performed pre-TAVR, at early follow-up (<48 h post-TAVR) and late follow-up (4-6 weeks post-TAVR). RESULTS: 27 patients (mean age 82.0 ± 7.0; 33.3% female) were recruited; 37.0% had diabetes mellitus and 59.3% had hypertension. Brachial artery FMD increased from 4.2 ± 1.6% (pre-TAVR) to 9.7 ± 3.5% at early follow-up (p < 0.0001). At late follow-up, improvement compared with early follow-up was sustained (8.7 ± 1.9%, p = 0.27). Resting brachial arterial flow velocities decreased significantly at late follow-up (11.24 ± 5.16 vs. 7.73 ± 2.79 cm/s, p = 0.003). Concordantly, at late follow-up, there was decrease in resting wall shear stress (WSS; 14.8 ± 7.8 vs. 10.6 ± 4.8dyne/cm2, p = 0.01), peak WSS (73.1 ± 34.1 vs. 58.8 ± 27.8dyne/cm2, p = 0.03) and cumulative WSS (3543 ± 1852 vs. 2504 ± 1089dyne·s/cm2, p = 0.002). Additionally, a favourable inverse correlation between cumulative WSS and FMD was restored at late follow-up (r = -0.21 vs. r = 0.49). CONCLUSION: Endothelial function in patients with AS improves early post-TAVR and this improvement is sustained. This likely occurs as a result of improved arterial haemodynamics, leading to lower localised WSS and release of vasoactive mediators that may also alleviate myocardial ischaemia.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Coração , Hemodinâmica , Humanos , Masculino , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
Circ Cardiovasc Interv ; 14(1): e009586, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33322917

RESUMO

BACKGROUND: Coronary artery disease is common in patients with severe aortic stenosis. Computed tomography-derived fractional flow reserve (CT-FFR) is a clinically used modality for assessing coronary artery disease, however, its use has not been validated in patients with severe aortic stenosis. This study assesses the safety, feasibility, and validity of CT-FFR in patients with severe aortic stenosis. METHODS: Prospectively recruited patients underwent standard-protocol invasive FFR and coronary CT angiography (CTA). CTA images were analyzed by central core laboratory (HeartFlow, Inc) for independent evaluation of CT-FFR. CT-FFR data were compared with FFR (ischemia defined as FFR ≤0.80). RESULTS: Forty-two patients (68 vessels) underwent FFR and CTA; 39 patients (92.3%) and 60 vessels (88.2%) had interpretable CTA enabling CT-FFR computation. Mean age was 76.2±6.7 years (71.8% male). No patients incurred complications relating to premedication, CTA, or FFR protocol. Mean FFR and CT-FFR were 0.83±0.10 and 0.77±0.14, respectively. CT calcium score was 1373.3±1392.9 Agatston units. On per vessel analysis, there was positive correlation between FFR and CT-FFR (Pearson correlation coefficient, R=0.64, P<0.0001). Sensitivity, specificity, positive predictive value, and negative predictive values were 73.9%, 78.4%, 68.0%, and 82.9%, respectively, with 76.7% diagnostic accuracy. The area under the receiver-operating characteristic curve for CT-FFR was 0.83 (0.72-0.93, P<0.0001), which was higher than that of CTA and quantitative coronary angiography (P=0.01 and P<0.001, respectively). Bland-Altman plot showed mean bias between FFR and CT-FFR as 0.059±0.110. On per patient analysis, the sensitivity, specificity, positive predictive, and negative predictive values were 76.5%, 77.3%, 72.2%, and 81.0% with 76.9% diagnostic accuracy. The per patient area under the receiver-operating characteristic curve analysis was 0.81 (0.67-0.95, P<0.0001). CONCLUSIONS: CT-FFR is safe and feasible in patients with severe aortic stenosis. Our data suggests that the diagnostic accuracy of CT-FFR in this cohort potentially enables its use in clinical practice and provides the foundation for future research into the use of CT-FFR for coronary evaluation pre-aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Volume Sistólico , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda
10.
Open Heart ; 7(2)2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33004619

RESUMO

The use of fractional flow reserve (FFR) in guiding revascularisation improves patient outcomes and has been well-established in clinical guidelines. Despite this, the uptake of FFR has been limited, likely attributable to the perceived increase in procedural time and use of hyperaemic agents that can cause patient discomfort. This has led to the development of instantaneous wave-free ratio (iFR), an alternative non-hyperaemic pressure ratio (NHPR). Since its inception, the use of iFR has been supported by an increasing body of evidence and is now guideline recommended. More recently, other commercially available NHPRs including diastolic hyperaemia-free ratio and resting full-cycle ratio have emerged. Studies have demonstrated that these indices, in addition to mean distal coronary artery pressure to mean aortic pressure ratio, are mathematically analogous (with specific nuances) to iFR. Additionally, there is increasing data demonstrating the equivalent diagnostic performance of alternative NHPRs in comparison with iFR and FFR. These NHPRs are now integral within most current pressure wire systems and are commonly available in the catheter laboratory. It is therefore key to understand the fundamental differences and evidence for NHPRs to guide appropriate clinical decision-making.


Assuntos
Pressão Arterial , Cateterismo Cardíaco , Doença da Artéria Coronariana/terapia , Circulação Coronária , Intervenção Coronária Percutânea , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Tomada de Decisão Clínica , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Transdutores de Pressão , Resultado do Tratamento
11.
J Interv Cardiol ; 2020: 7467943, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32565755

RESUMO

Fractional flow reserve (FFR) is routinely used to determine lesion severity prior to percutaneous coronary intervention (PCI). However, there is an increasing recognition that FFR may also be useful following PCI to identify mechanisms leading to restenosis and the need for repeat revascularization. Post-PCI FFR is associated with the presence and severity of stent under-expansion and may help identify peri-stent-related complications. FFR pullback may also unmask other functionally significant lesions within the target vessel that were not appreciable on angiography. Recent studies have confirmed the prognostic utility of performing routine post-PCI FFR and suggest possible interventional targets that would improve stent durability. In this review, we detail the theoretical basis underlying post-PCI FFR, provide practical tips to facilitate measurement, and discuss the growing evidence supporting its use.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/cirurgia , Hemodinâmica , Humanos , Complicações Pós-Operatórias/fisiopatologia , Stents , Resultado do Tratamento
12.
Cardiovasc Revasc Med ; 21(11): 1336-1342, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32359889

RESUMO

BACKGROUND/PURPOSE: Coronary artery disease (CAD) is common in patients undergoing transcatheter aortic valve replacement (TAVR), although its prognostic significance is questionable. Significant CAD stratified using SYNTAX score (SS) has been associated with greater mortality, yet it is unknown whether the functional impact of CAD also impacts outcomes in this cohort. DILEMMA score (DS) is a validated angiographic functional scoring tool that correlates with fractional flow reserve and instantaneous wave-free ratio. This study sought to assess the functional impact of CAD on outcomes in patients undergoing TAVR for severe aortic stenosis (AS). METHODS/MATERIALS: 229 patients were included in this analysis. Patients underwent angiographic DS and SS and were classified using predefined values. The primary endpoint was one-year all-cause mortality, with secondary endpoints of 30-day major adverse cardiac and cerebrovascular events (MACCE). RESULTS: The mean age was 83.9 ± 0.5 years (55.0% female), with 11.8% all-cause mortality. CAD defined by ≥30% stenosis in any vessel was not associated with adverse outcomes (HR = 1.08, p = 0.84). However, the risk of one-year mortality was greater in patients with either SS > 9 (20.8% vs. 9.4%, HR 2.34, p = 0.03) or DS > 2 (18.4% vs. 8.5%, HR = 2.28, p = 0.03). Both scoring systems were also associated with 30-day MACCE (both p < 0.05). After multivariate adjustment, independent predictors of one-year mortality were DS > 2 (HR = 2.29, p = 0.04), left ventricular ejection fraction <50% (HR 2.66, p = 0.04) and COPD (HR 2.43, p = 0.04). CONCLUSION: Our results demonstrate that angiographic functional scoring is independently predictive of both 12-month mortality and 30-day MACCE following TAVR.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
13.
Hypertension ; 75(6): 1557-1564, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32306768

RESUMO

Severe aortic stenosis induces abnormalities in central aortic pressure, with consequent impaired organ and tissue perfusion. Relief of aortic stenosis by transcatheter aortic valve replacement (TAVR) is associated with both a short- and long-term hypertensive response. Counterintuitively, patients who are long-term normotensive post-TAVR have a worsened prognosis compared with patients with hypertension, yet the underlying mechanisms are not understood. We investigated immediate changes in invasively measured left ventricular and central aortic pressure post-TAVR in patients with severe aortic stenosis using aortic reservoir pressure, wave intensity analysis, and indices of aortic function. Fifty-four patients (mean age 83.6±6.2 years, 50.0% female) undergoing TAVR were included. We performed reservoir pressure and wave intensity analysis on invasively acquired pressure waveforms from the ascending aorta and left ventricle immediately pre- and post-TAVR. Following TAVR, there were increases in systolic, diastolic, mean, and pulse aortic pressures (all P<0.05). Post-TAVR reservoir pressure was unchanged (54.5±12.4 versus 56.6±14.0 mm Hg, P=0.30) whereas excess pressure increased 47% (29.0±10.9 versus 42.6±15.5 mm Hg, P<0.001). Wave intensity analysis (arbitrary units, au) demonstrated increased forward compression wave (64.9±35.5 versus 124.4±58.9, ×103 au, P<0.001), backward compression wave (11.6±5.5 versus 14.4±6.9, ×103 au, P=0.01) and forward expansion wave energies (43.2±27.3 versus 82.8±53.1, ×103 au, P<0.001). Subendocardial viability ratio improved with aortic function effectively unchanged post-TAVR. Increased central aortic pressure following TAVR relates to increased transmitted power and energy to the proximal aorta with increased excess pressure but unchanged reservoir pressure. These changes provide a potential mechanism for the improved prognosis associated with relative hypertension post-TAVR.


Assuntos
Aorta , Estenose da Valva Aórtica , Pressão Arterial , Determinação da Pressão Arterial/métodos , Hemodinâmica , Análise de Onda de Pulso/métodos , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Período Perioperatório/métodos , Prognóstico , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
14.
Heart Lung Circ ; 29(1): 149-155, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30686645

RESUMO

BACKGROUND: Off-pump coronary artery bypass grafting (CABG) negates the requirement for extracorporeal circulation used with the traditional on-pump approach. However, off-pump CABG is technically more challenging and may theoretically lead to less complete revascularisation. Recent data suggests a prognostic benefit for traditional on-pump CABG, but the mechanism for this remains unclear. We hypothesised that the inferior outcomes with off-pump CABG could be driven by the need for repeat revascularisation, with this benefit only becoming clear at long-term follow-up. We therefore evaluated short, medium and long-term outcomes of patients undergoing revascularisation with on vs. off-pump CABG. METHODS: Electronic databases were searched to identify suitable randomised controlled trials enrolling ≥100 patients in each arm. Clinical outcomes were extracted at 30-days, 12-months or >4years. The primary outcome was long-term all-cause death, while secondary outcomes included 30-day, 12-month and >4-year cardiac death, stroke, myocardial infarction or revascularisation. RESULTS: Thirteen (13) studies comprising 13,234 patients were included. Off-pump CABG was associated with an increased risk of all-cause death (Odds Ratio [OR] 1.18, 95% confidence interval [CI] 1.02-1.32, p=0.01) and repeat bypass surgery (OR 2.57, 95%CI 1.23-5.39, p=0.01) at long-term follow-up. A significant, increased requirement for revascularisation in off-pump was seen at 12-month follow-up (OR 1.59, 95%CI 1.09-2.33, p=0.02). No differences were noted between groups at 30-days, 12-months and >4years for myocardial infarction or stroke. CONCLUSIONS: Off-pump CABG is associated with significantly higher rates of all-cause mortality rate at long-term follow-up. These outcomes demonstrate a temporal relationship that may be driven by a greater requirement for repeat revascularisation at 1- and 5-year follow-up. STUDY REGISTRATION: CRD42018102019 (PROSPERO).


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Circulação Extracorpórea/efeitos adversos , Infarto do Miocárdio , Acidente Vascular Cerebral , Feminino , Humanos , Masculino , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade
15.
Cardiovasc Revasc Med ; 20(10): 865-870, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30578169

RESUMO

BACKGROUND/PURPOSE: Biodegradable-polymer (BP) and polymer-free (PF) drug eluting stents (DES) were developed to reduce the risk of delayed arterial healing observed with durable-polymer (DP) platforms. Although trials demonstrate BP-DES and PF-DES are non-inferior to DP-DES, there is limited data directly comparing these technologies. We performed a meta-analysis to assess the efficacy and safety of BP-DES versus PF-DES for the treatment of coronary artery disease. METHODS/MATERIALS: Electronic searches were performed identifying randomized trials comparing BP-DES with PF-DES. Co-primary efficacy endpoints were target vessel revascularization (TVR), target lesion revascularization (TLR) and angiographic in-stent late lumen loss (LLL). Co-secondary safety endpoints were all-cause death, myocardial infarction (MI) and stent thrombosis (ST). RESULTS: Of 208 studies, 5 met inclusion criteria including 1975 patients. At mean follow-up (14 ±â€¯5 months), BP-DES were associated with significantly reduced rates of TVR (OR 0.58, 95%CI 0.37-0.92, p = 0.02), TLR (4.7% vs 9.5%) (OR 0.48, 95%CI 0.31-0.75, p = 0.001) and in-stent LLL (pooled mean difference -0.20 mm, 95%CI -0.24 to -0.16, p < 0.001). There was no difference in safety, including all-cause death (OR 1.24, 95%CI 0.68-2.28, p = 0.48), MI (OR 0.92, 95%CI 0.54-1.56, p = 0.75) or ST (OR 1.58, 95%CI 0.67-3.73, p = 0.30). CONCLUSIONS: These data suggests that BP-DES are more efficacious when compared with PF-DES for the treatment of CAD.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Causas de Morte , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Trombose Coronária/mortalidade , Humanos , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Resultado do Tratamento
16.
Am J Physiol Cell Physiol ; 310(7): C520-41, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26718628

RESUMO

Although numerous protocols have been developed for differentiation of neurons from a variety of pluripotent stem cells, most have concentrated on being able to specify effectively appropriate neuronal subtypes and few have been designed to enhance or accelerate functional maturity. Of those that have, most employ time courses of functional maturation that are rather protracted, and none have fully characterized all aspects of neuronal function, from spontaneous action potential generation through to postsynaptic receptor maturation. Here, we describe a simple protocol that employs the sequential addition of just two supplemented media that have been formulated to separate the two key phases of neural differentiation, the neurogenesis and synaptogenesis, each characterized by different signaling requirements. Employing these media, this new protocol synchronized neurogenesis and enhanced the rate of maturation of pluripotent stem cell-derived neural precursors. Neurons differentiated using this protocol exhibited large cell capacitance with relatively hyperpolarized resting membrane potentials; moreover, they exhibited augmented: 1) spontaneous electrical activity; 2) regenerative induced action potential train activity; 3) Na(+) current availability, and 4) synaptic currents. This was accomplished by rapid and uniform development of a mature, inhibitory GABAAreceptor phenotype that was demonstrated by Ca(2+) imaging and the ability of GABAAreceptor blockers to evoke seizurogenic network activity in multielectrode array recordings. Furthermore, since this protocol can exploit expanded and frozen prepatterned neural progenitors to deliver mature neurons within 21 days, it is both scalable and transferable to high-throughput platforms for the use in functional screens.


Assuntos
Técnicas de Cultura de Células/métodos , Diferenciação Celular/fisiologia , Meios de Cultura/química , Células-Tronco Pluripotentes Induzidas/citologia , Células-Tronco Neurais/citologia , Western Blotting , Ciclo Celular/fisiologia , Linhagem Celular , Técnicas de Cocultura , Proteína de Ligação ao Elemento de Resposta ao AMP Cíclico/metabolismo , Quinase 3 da Glicogênio Sintase/metabolismo , Glicogênio Sintase Quinase 3 beta , Humanos , Processamento de Imagem Assistida por Computador , Imuno-Histoquímica , Células-Tronco Pluripotentes Induzidas/metabolismo , Microscopia Eletrônica de Varredura , Células-Tronco Neurais/metabolismo , Neurogênese/fisiologia , Técnicas de Patch-Clamp , Receptores de GABA-A/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...