Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
AJNR Am J Neuroradiol ; 34(8): 1506-12, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23557960

RESUMO

BACKGROUND AND PURPOSE: There is a desire within many institutions to reduce the radiation dose in CTP examinations. The purpose of this study was to simulate dose reduction through the addition of noise in brain CT perfusion examinations and to determine the subsequent effects on quality and quantitative interpretation. MATERIALS AND METHODS: A total of 22 consecutive reference CTP scans were identified from an institutional review board-approved prospective clinical trial, all performed at 80 keV and 190 mAs. Lower-dose scans at 188, 177, 167, 127, and 44 mAs were generated through the addition of spatially correlated noise to the reference scans. A standard software package was used to generate CBF, CBV, and MTT maps. Six blinded radiologists determined quality scores of simulated scans on a Likert scale. Quantitative differences were calculated. RESULTS: For qualitative analysis, the correlation coefficients for CBF (-0.34; P < .0001), CBV (-0.35; P < .0001), and MTT (-0.44; P < .0001) were statistically significant. Interobserver agreements in quality for the simulated 188-, 177-, 167-, 127-, and 44-mAs scans for CBF were 0.95, 0.98, 0.98, 0.95, and 0.52, respectively. Interobserver agreements in quality for the simulated CBV were 1, 1, 1, 1, and 0.83, respectively. For MTT, the interobserver agreements were 0.83, 0.86, 0.88, 0.74, and 0.05, respectively. For quantitative analysis, only the lowest simulated dose of 44 mAs showed statistically significant differences from the reference scan values for CBF (-1.8; P = .04), CBV (0.07; P < .0001), and MTT (0.46; P < .0001). CONCLUSIONS: From a reference CTP study performed at 80 keV and 190 mAs, this simulation study demonstrates the potential of a 33% reduction in tube current and dose while maintaining image quality and quantitative interpretations. This work can be used to inform future studies by using true, nonsimulated scans.


Assuntos
Artefatos , Encéfalo/diagnóstico por imagem , Angiografia Cerebral/métodos , Interpretação de Imagem Assistida por Computador/métodos , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
2.
AJNR Am J Neuroradiol ; 34(2): 292-8, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22859289

RESUMO

BACKGROUND AND PURPOSE: DCI is a serious complication following aneurysmal SAH and remains a leading cause of morbidity and mortality. Our aim was to evaluate CTP in aneurysmal SAH by using outcome measures of DCI. MATERIALS AND METHODS: This was a retrospective study of consecutive patients with SAH enrolled in a prospective institutional review board-approved clinical accuracy trial. Qualitative CTP deficits were determined by 2 neuroradiologists blinded to clinical and imaging data. Quantitative CTP was performed by using a standardized protocol with region-of-interest placement sampling of the cortex. Primary outcome measures were permanent neurologic deficits and infarction. The secondary outcome measure was DCI, defined as clinical deterioration. CTP test characteristics (95% CI) were determined for each outcome measure. Statistical significance was calculated by using the Fisher exact and Student t tests. ROC curves were generated to determine accuracy and threshold analysis. RESULTS: Ninety-six patients were included. Permanent neurologic deficits developed in 33% (32/96). CTP deficits were seen in 78% (25/32) of those who developed permanent neurologic deficits and 34% (22/64) of those without (P < .0001). CTP deficits had 78% (61%-89%) sensitivity, 66% (53%-76%) specificity, and 53% (39%-67%) positive and 86% (73%-93%) negative predictive values. Infarction occurred in 18% (17/96). CTP deficits were seen in 88% (15/17) of those who developed infarction and 41% (32/79) of those without (P = .0004). CTP deficits had an 88% (66%-97%) sensitivity, 59% (48%-70%) specificity, and 32% (20%-46%) positive and 96% (86%-99%) negative predictive values. DCI was diagnosed in 50% (48/96). CTP deficits were seen in 81% (39/48) of patients with DCI and in 17% (8/48) of those without (P < .0001). CTP deficits had 81% (68%-90%) sensitivity, 83% (70%-91%) specificity, and 83% (70%-91%) positive and 82% (69%-90%) negative predictive values. Quantitative CTP revealed significantly reduced CBF and prolonged MTT for DCI, permanent neurologic deficits, and infarction. ROC analysis showed that CBF and MTT had the highest accuracy. CONCLUSIONS: CTP may add prognostic information regarding DCI and poor outcomes in aneurysmal SAH.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/mortalidade , Imagem de Perfusão/métodos , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/mortalidade , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Infarto Cerebral/diagnóstico por imagem , Infarto Cerebral/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Imagem de Perfusão/normas , Valor Preditivo dos Testes , Prognóstico , Curva ROC , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/normas
3.
AJNR Am J Neuroradiol ; 32(11): 2047-53, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21960495

RESUMO

BACKGROUND AND PURPOSE: DCI is a serious complication following aneurysmal SAH leading to permanent neurologic deficits, infarction, and death. Our aim was to prospectively evaluate the diagnostic accuracy of CTP and to determine a quantitative threshold for DCI in aneurysmal SAH. MATERIALS AND METHODS: Patients with SAH were prospectively enrolled in a protocol approved by the institutional review board. CTP was performed during the typical time period for DCI, between days 6 and 8 following SAH. Quantitative CBF, CBV, and MTT values were obtained by using standard region-of-interest placement sampling of gray matter. The reference standard for DCI is controversial and consisted of clinical and imaging criteria in this study. In a subanalysis of vasospasm, DSA was used as the reference standard. ROC curves determined the diagnostic accuracy by using AUC. Optimal threshold values were calculated by using the patient population utility method. RESULTS: Ninety-seven patients were included; 41% (40/97) had DCI. Overall diagnostic accuracy was 93% for CBF, 88% for MTT, and 72% for CBV. Optimal threshold values were 35 mL/100 g/min (90% sensitivity, 68% specificity) for CBF and 5.5 seconds (73% sensitivity, 79% specificity) for MTT. In the subanalysis (n = 57), 63% (36/57) had vasospasm. Overall diagnostic accuracy was 94% for CBF, 85% for MTT, and 72% for CBV. Optimal threshold values were 36.5 mL/100 g/min (95% sensitivity, 70% specificity) for CBF and 5.4 seconds (78% sensitivity, 70% specificity) for MTT. CONCLUSIONS: CBF and MTT have the highest overall diagnostic accuracy. Threshold values of 35 mL/100 g/min for CBF and 5.5-second MTT are suggested for DCI on the basis of the patient population utility method. Absolute threshold values may not be generalizable due to differences in scanner equipment and postprocessing methods.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/etiologia , Angiografia Cerebral/métodos , Imagem de Perfusão/métodos , Hemorragia Subaracnóidea/complicações , Hemorragia Subaracnóidea/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Diagnóstico Tardio , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
AJNR Am J Neuroradiol ; 31(10): 1853-60, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20884748

RESUMO

BACKGROUND AND PURPOSE: In recent years, the role of CTA and CTP for vasospasm diagnosis in the setting of ASAH has been the subject of many research studies. The purpose of this study was to perform a meta-analysis of the diagnostic performance of CTA and CTP for vasospasm in patients with ASAH by using DSA as the criterion standard. MATERIALS AND METHODS: The search strategy for research studies was based on the Cochrane Handbook for Systematic Reviews, including literature data bases (PubMed, Embase, Cochrane Database of Systematic Reviews, and the Web of Science) and reference lists of manuscripts published from January 1996 to February 2009. The inclusion criteria were the following: 1) published manuscripts, 2) original research studies with prospective or retrospective data, 3) patients with ASAH, 4) CTA or CTP as the index test, and 5) DSA as the reference standard. Three reviewers independently assessed the quality of these research studies by using the QUADAS tool. Pooled estimates of sensitivity, specificity, LR+, LR-, DOR, and the SROC curve were determined. RESULTS: CTA and CTP searches yielded 505 and 214 manuscripts, respectively. Ten research studies met inclusion criteria for each CTA and CTP search. Six CTA and 3 CTP studies had sufficient data for statistical analysis. CTA pooled estimates had 79.6% sensitivity (95%CI, 74.9%-83.8%), 93.1%specificity (95%CI, 91.7%-94.3%), 18.1 LR+ (95%CI, 7.3-45.0), and 0.2 LR- (95%CI, 0.1-0.4); and CTP pooled estimates had 74.1% sensitivity (95%CI, 58.7%- 86.2%), 93.0% specificity (95% CI, 79.6%-98.7%), 9.3 LR+ (95%CI, 3.4-25.9), and 0.2 LR- (95%CI, 0.04-1.2). Overall DORs were 124.5 (95%CI, 28.4-546.4) for CTA and 43.0 (95%CI, 6.5-287.1) for CTP. Area under the SROC curve was 98 ± 2.0%for CTA and 97 ± 3.0% for CTP. CONCLUSIONS: The high diagnostic accuracy determined for both CTA and CTP in this meta-analysis suggests that they are potentially valuable techniques for vasospasm diagnosis in ASAH. Awareness of these results may impact patient care by providing supportive evidence for more effective use of CTA and CTP imaging in ASAH.


Assuntos
Angiografia Cerebral/normas , Circulação Cerebrovascular , Tomografia Computadorizada por Raios X/normas , Vasoespasmo Intracraniano/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vasoespasmo Intracraniano/fisiopatologia
5.
Clin Imaging ; 21(3): 213-23, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9156313

RESUMO

While an acoustic neuroma is the most common cause of a cerebellopontine angle (CPA) mass, it accounts for only 1-10% of cases of sensorineural hearing loss (SNHL). There are many other etiologies of SNHL, with characteristic imaging features, which may or may not be confined to the CPA.


Assuntos
Ângulo Cerebelopontino , Perda Auditiva Neurossensorial/diagnóstico , Neuroma Acústico/diagnóstico , Cistos Aracnóideos , Encefalopatias/complicações , Encefalopatias/diagnóstico , Ângulo Cerebelopontino/diagnóstico por imagem , Ângulo Cerebelopontino/patologia , Diagnóstico Diferencial , Perda Auditiva Neurossensorial/etiologia , Humanos , Lipoma , Imageamento por Ressonância Magnética , Neuroma Acústico/complicações , Tomografia Computadorizada por Raios X
7.
Spine (Phila Pa 1976) ; 19(9): 1063-5, 1994 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-8029742

RESUMO

STUDY DESIGN: The adverse effects of lumbar myelography in 400 patients were analyzed. OBJECTIVES: To determine whether adverse effects of lumbar myelography occur less frequently when using the fine needle technique. SUMMARY OF BACKGROUND DATA: Lumbar myelography can be performed safely on an outpatient basis. The side effects may be reduced by using the fine needle technique. METHODS: Four hundred patients were studied; 200 with a 25 gauge needle and 200 with a 22 gauge needle. Each was given a questionnaire and instructed to report details of post-myelogram adverse effects. RESULTS: Transient worsening of back or leg symptoms, headache, and nausea and vomiting, the most frequent complaints, were reduced in the 200 patients studied with a 25 gauge needle rather than a 22 gauge needle. Regardless of the needle, patients with normal myelograms reported more adverse effects. CONCLUSIONS: A lower frequency of adverse effects can be achieved when fine needle is used for lumbar myelography. More adverse effects are reported by patients with normal myelograms.


Assuntos
Mielografia/efeitos adversos , Agulhas , Assistência Ambulatorial , Feminino , Cefaleia/epidemiologia , Cefaleia/etiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Mielografia/instrumentação , Náusea/epidemiologia , Náusea/etiologia , Pré-Medicação , Vômito/epidemiologia , Vômito/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...