Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Diabetol ; 59(1): 21-30, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34427780

RESUMO

AIMS: The impact of Ramadan exposure to Gestational Diabetes Mellitus (GDM) pregnancies is not known. We therefore aimed to assess the association of Ramadan with maternal and neonatal outcomes among pregnant women with GDM. METHODS: Retrospective cohort study of 345 Muslim women with singleton pregnancies who attended a major Sydney teaching hospital during the period 1989-2010, was undertaken. Exposure to Ramadan was stratified by the: (1) total pregnancy days exposed to Ramadan, (2) duration (hours) of daily fasting and (3) trimester of exposure. Maternal and neonatal outcomes were examined by exposure status, and never exposed pregnancies were comparator in all three analyses. Fasting status was not recorded. RESULTS: We found no significant effect of Ramadan exposure on mean birthweight, macrosomia and maternal outcomes. However, we found a significant trend for increased neonatal hyperbilirubinemia with increasing Ramadan days exposure and later trimester exposure (ptrend ≤ 0.02 for both), with adjusted OR 3.9 (p=0.03) for those with ≥ 21 days exposure to Ramadan and adjusted OR 4.3 (p=0.04) for third trimester exposure. Conversely longer Ramadan exposure and late trimester exposure were independently associated with a lower prevalence of neonatal hypoglycaemia (adjusted OR 0.4 and 0.3 for ≥ 21 days and third trimester exposure, respectively). Furthermore, neonatal hypoglycaemia decreased for the fasting period of > 15 h group (adjusted OR 0.2, p = 0.01). CONCLUSIONS: Ramadan exposure is associated with reduced neonatal hypoglycaemia, with no effect on birthweight, implying more favourable glycaemic control. However, the fourfold excess of neonatal hyperbilirubinemia indicates a need for further study of Ramadan and GDM.


Assuntos
Diabetes Gestacional , Hipoglicemia , Peso ao Nascer , Diabetes Gestacional/epidemiologia , Feminino , Macrossomia Fetal/epidemiologia , Macrossomia Fetal/etiologia , Humanos , Hipoglicemia/epidemiologia , Hipoglicemia/etiologia , Recém-Nascido , Gravidez , Estudos Retrospectivos
2.
Diabetes Care ; 34(2): 335-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21216849

RESUMO

OBJECTIVE: The objective of this study was to evaluate the performance of blood glucose meters in diabetes associated with pregnancy (DP). RESEARCH DESIGN AND METHODS: Finger-prick blood glucose levels measured using six different glucose meters on 102 patients with DP attending an antenatal clinic were compared with laboratory plasma glucose results. HbA(1c) and hematocrit were also measured. RESULTS: The plasma glucose range was 2.2-9.4 mmol/L with hematocrit 33-37% and mean HbA(1c) 5.5% ± 0.56 (SD). All meters provided plasma equivalent results except one, which reported whole blood glucose that was adjusted to plasma equivalent values. The absolute glucose difference [meter--plasma glucose] was 0.232 ± 0.69 to 0.725 ± 0.62 mmol/L mean ± SD and bias ranged from 6.1 to 15.8%. Two meters were affected by hematocrit <36% (P < 0.05). CONCLUSIONS: Blood glucose meters in current use are not optimally accurate when compared with plasma glucose measurement in DP. Recognition of this deviation is essential to prevent inappropriate treatment of DP.


Assuntos
Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/normas , Glicemia/metabolismo , Diabetes Gestacional/diagnóstico , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 2/diagnóstico , Feminino , Hemoglobinas Glicadas/metabolismo , Hematócrito , Humanos , Hiperglicemia/diagnóstico , Gravidez , Cuidado Pré-Natal/normas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...