Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
ASAIO J ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38728744

RESUMO

The Pulmonary Assist System (PAS) is currently under development as a wearable respiratory assist system. In this study, the hemocompatibility of the PAS's axial-flow mechanical pump (AFP) was compared to other contemporary mechanical pumps in an acute ovine model. The PAS was attached to a normal sheep in a venovenous configuration using one of three pumps: 1) AFP, 2) ReliantHeart HeartAssist 5 (control), or 3) Abbott Pedimag (control) (n = 5 each). Each sheep was supported on the PAS for 12 hours with two L/minute of blood flow and four L/minute of sweep gas. Hemolysis, coagulation, inflammation, and platelet activation and loss were compared among the groups. In this study, the plasma-free hemoglobin (pfHb) was less than 10 mg/dl in all groups. The pfHb was significantly lower in the AFP group compared to other groups. There was no significant clot formation in the pumps and oxygenators in all groups. Furthermore, no significant differences in coagulation (oxygenator resistance, fibrinopeptide A), inflammation (white blood cell counts, IL-8), and platelet activation and loss (p-selectin, platelet counts) were observed among the groups (all, p > 0.05). This study demonstrates equivalent hemocompatibility of the PAS's AFP to other contemporary mechanical pumps with a reduced level of hemolysis on startup.

2.
bioRxiv ; 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38260509

RESUMO

The hollow fiber membrane bundle is the functional component of artificial lungs, transferring oxygen and carbon dioxide to and from the blood. It is also the primary location of blood clot formation and propagation in these devices. The geometric design of fiber bundles is defined by a narrow range of parameters that determine gas exchange efficiency and blood flow resistance, such as fiber packing density, path length, and frontal area. However, these parameters also affect thrombosis. This study investigated the effect of these parameters on clot formation using 3-D printed flow chambers that mimic the geometry and blood flow patterns of fiber bundles. Hollow fibers were represented by an array of vertical micro-rods (380 micron diameter) arranged with varying packing densities (40, 50, and 60%) and path lengths (2 and 4 cm). Blood was pumped through the device corresponding to three mean blood flow velocities (16, 20, and 25 cm/min). Results showed that (1) clot formation decreases dramatically with decreasing packing density and increasing blood flow velocity, (2) clot formation at the outlet of fiber bundle enhances deposition upstream, and consequently (3) greater path length provides more clot-free fiber surface area for gas exchange than a shorter path length. These results can be used to create less thrombogenic, more efficient artificial lung designs. Translational Impact Sentence: Fiber bundle parameters, such as decreased packing density, increased blood flow velocity, and a longer path length, can be used to design a less thrombogenic, more efficient artificial lung to extend functionality.

3.
ASAIO J ; 70(2): e23-e26, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37578993

RESUMO

A new, lightweight (2.3 kg), ambulatory pulmonary assist system (PAS) underwent preliminary evaluation in ambulatory sheep. The PAS was purposefully designed for long-term extracorporeal respiratory support for chronic lung disease and utilizes a novel, small (0.9 m 2 surface area) gas exchanger, the pulmonary assist device, with a modified Heart Assist 5 pump fitting in a small wearable pack. Prototype PAS were attached to two sheep in venovenous configuration for 7 and 14 days, evaluating ability to remain thrombus free; maintain gas exchange and blood flow resistance; avoid biocompatibility-related complications while allowing safe ambulation. The PAS achieved 1.56 L/min of flow at 10.8 kRPM with a 24 Fr cannula in sheep one and 2.0 L/min at 10.5 kRPM with a 28 Fr cannula in sheep 2 without significant change. Both sheep walked freely, demonstrating the first application of truly ambulatory ECMO in sheep. While in vitro testing evaluated PAS oxygen transfer rates of 104.6 ml/min at 2 L/min blood flow, oxygen transfer rates averaged 60.6 ml/min and 70.6 ml/min in studies 1 and 2, due to average hemoglobin concentrations lower than humans (8.9 and 10.5 g/dl, respectively). The presented cases support uncomplicated ambulation using the PAS.


Assuntos
Pneumopatias , Pulmão , Humanos , Ovinos , Animais , Hemodinâmica/fisiologia , Oxigênio , Cânula
4.
J Heart Lung Transplant ; 43(2): 293-302, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37907183

RESUMO

BACKGROUND: Right heart failure is the major cause of death in pulmonary hypertension. Lung transplantation is the only long-term treatment option for patients who fail medical therapy. Due to the scarcity of donor lungs, there is a critical need to develop durable mechanical support for the failing right heart. A major design goal for durable support is to reduce the size and complexity of devices to facilitate ambulation. Toward this end, we sought to deploy wearable mechanical support technology in a sheep disease model of chronic right heart failure. METHODS: In 6 sheep with chronic right heart failure, a mechanical support system consisting of an extracorporeal blood pump coupled with a gas exchange unit was attached in a right atrium-to-left atrium configuration for up to 7 days. Circuit performance, hematologic parameters, and animal hemodynamics were analyzed. RESULTS: Six subjects underwent the chronic disease model for 56 to 71 days. Three of the subjects survived to the 7-day end-point for circulatory support. The circuit provided 2.8 (0.5) liter/min of flow compared to the native pulmonary blood flow of 3.5 (1.1) liter/min. The animals maintained physiologically balanced blood gas profile with a sweep flow of 1.2 (1.0) liter/min. Two animals freely ambulated while wearing the circuit. CONCLUSIONS: Our novel mechanical support system provided physiologic support for a large animal model of pulmonary hypertension with right heart failure. The small footprint of the circuit and the low sweep requirement demonstrate the feasibility of this technology to enable mobile ambulatory applications.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Hipertensão Pulmonar , Humanos , Animais , Ovinos , Hipertensão Pulmonar/terapia , Insuficiência Cardíaca/cirurgia , Hemodinâmica/fisiologia , Átrios do Coração
5.
ASAIO J ; 69(6): 527-532, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728837

RESUMO

Heparin anticoagulation increases the bleeding risk during extracorporeal life support (ECLS). This study determined whether factor XII (FXII) silencing using short interfering RNA (siRNA) can provide ECLS circuit anticoagulation without bleeding. Adult male, Sprague-Dawley rats were randomized to four groups (n = 3 each) based on anticoagulant: (1) no anticoagulant, (2) heparin, (3) FXII siRNA, or (4) nontargeting siRNA. Heparin was administered intravenously before and during ECLS. FXII or nontargeting siRNA were administered intravenously 3 days before the initiation of ECLS via lipidoid nanoparticles. The rats were placed on pumped, arteriovenous ECLS for 8 hours or until the blood flow resistance reached three times its baseline resistance. Without anticoagulant, mock-oxygenator resistance tripled within 7 ± 2 minutes. The resistance in the FXII siRNA group did not increase for 8 hours. There were no significant differences in resistance or mock-oxygenator thrombus volume between the FXII siRNA and the heparin groups. However, the bleeding time in the FXII siRNA group (3.4 ± 0.6 minutes) was significantly shorter than that in the heparin group (5.5 ± 0.5 minutes, p < 0.05). FXII silencing using siRNA provided simpler anticoagulation of ECLS circuits with reduced bleeding time as compared to heparin. http://links.lww.com/ASAIO/A937.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Animais , Masculino , Ratos , Anticoagulantes , Fator XII/genética , Heparina , Ratos Sprague-Dawley , RNA Interferente Pequeno/genética , Trombose/etiologia , Trombose/prevenção & controle
6.
Macromol Biosci ; 23(4): e2200479, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36609882

RESUMO

The artificial lung has provided life-saving support for pulmonary disease patients and recently afforded patients with severe cases of COVID-19 better prognostic outcomes. While it addresses a critical medical need, reducing the risk of clotting inside the device remains challenging. Herein, a two-step surface coating process of the lung circuit using Zwitterionic polysulfobetaine methacrylate is evaluated for its nonspecific protein antifouling activity. It is hypothesized that similarly applied coatings on materials integrated (IT) or nonintegrated (NIT) into the circuit will yield similar antifouling activity. The effects of human plasma preconditioned with nitric oxide-loaded liposome on platelet (plt) fouling are also evaluated. Fibrinogen antifouling activities in coated fibers are similar in the IT and NIT groups. It however decreases in coated polycarbonate (PC) in the IT group. Also, plt antifouling activity in coated fibers is similar in the IT and NIT groups and is lower in coated PC and Tygon in the IT group compared to the NIT group. Coating process optimization in the IT lung circuit may help address difference in the coating appearance of outer and inner fiber bundle fibers, and the NO-liposome significantly reduces (86%) plt fouling on fibers indicating its potential use for blood anticoagulation.


Assuntos
COVID-19 , Lipossomos , Humanos , Lipossomos/metabolismo , COVID-19/metabolismo , Plaquetas/metabolismo , Pulmão , Adsorção
7.
J Heart Lung Transplant ; 42(7): 859-867, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36435685

RESUMO

INTRODUCTION: Right ventricular failure (RVF) is a major cause of mortality in pulmonary hypertension (PH). Mechanical circulatory support holds promise for patients with medically refractory PH, but there are no clinical devices for long-term right ventricular (RV) support. Investigations into optimal device parameters and circuit configurations for PH-induced RVF (PH-RVF) are needed. METHODS: Eleven sheep underwent previously published chronic PH model. We then evaluated a low-profile, ventricular assist device (VAD)-quality pump combined with a novel low-resistance membrane oxygenator (Pulmonary Assist Device, PAD) under one of four central cannulation strategies: right atrium-to-left atrium (RA-LA, N = 3), RA-to-pulmonary artery (RA-PA, N=3), pumpless pulmonary artery-to-left atrium (PA-LA, N = 2), and RA-to-ascending aorta (RA-Ao, N = 3). Acute-on-chronic RVF (AoC RVF) was induced, and mechanical support was provided for up to 6 hours at blood flow rates of 1 to 3 liter/min. Circuit parameters, physiologic, hemodynamic, and echocardiography data were collected. RESULTS: The RA-LA configuration achieved blood flow of 3 liter/min. Meanwhile, RA-PA and RA-Ao faced challenges maintaining 3 liter/min of flow due to higher circuit afterload. Pumpless PA-LA was flow-limited due to anatomical limitations inherent to this animal model. RA-LA and RA-Ao demonstrated serial RV unloading with increasing circuit flow, while RA-PA did not. RA-LA also improved left ventricular (LV) and septal geometry by echocardiographic assessment and had the lowest inotropic dependence. CONCLUSION: RA-LA and RA-Ao configurations unload the RV, while RA-LA also lowers pump speed and inotropic requirements, and improves LV mechanics. RA-PA provide inferior support for PH-RVF, while an alternate animal model is needed to evaluate PA-LA.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Hipertensão Pulmonar , Animais , Ovinos , Hipertensão Pulmonar/terapia , Ventrículos do Coração , Átrios do Coração , Hemodinâmica
8.
PLoS Comput Biol ; 18(10): e1010277, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36190991

RESUMO

Over the past decade, much of the development of computational models of device-related thrombosis has focused on platelet activity. While those models have been successful in predicting thrombus formation in medical devices operating at high shear rates (> 5000 s-1), they cannot be directly applied to low-shear devices, such as blood oxygenators and catheters, where emerging information suggest that fibrin formation is the predominant mechanism of clotting and platelet activity plays a secondary role. In the current work, we augment an existing platelet-based model of thrombosis with a partial model of the coagulation cascade that includes contact activation of factor XII and fibrin production. To calibrate the model, we simulate a backward-facing-step flow channel that has been extensively characterized in-vitro. Next, we perform blood perfusion experiments through a microfluidic chamber mimicking a hollow fiber membrane oxygenator and validate the model against these observations. The simulation results closely match the time evolution of the thrombus height and length in the backward-facing-step experiment. Application of the model to the microfluidic hollow fiber bundle chamber capture both gross features such as the increasing clotting trend towards the outlet of the chamber, as well as finer local features such as the structure of fibrin around individual hollow fibers. Our results are in line with recent findings that suggest fibrin production, through contact activation of factor XII, drives the thrombus formation in medical devices operating at low shear rates with large surface area to volume ratios.


Assuntos
Fibrina , Trombose , Coagulação Sanguínea , Plaquetas , Fator XII , Humanos
9.
Physiol Rep ; 10(10): e15136, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35582996

RESUMO

BACKGROUND: Pulmonary arterial hypertension (PAH) increases right ventricular (RV) workload and decreases myocardial oxygen reserve, eventually leading to poor cardiac output. This study created and assessed a novel model of RV work output based on RV hemodynamics and oxygen supply, allowing new insight into causal mechanisms of RV dysfunction. METHODS: The RV function model was built upon an earlier, left ventricular model and further adjusted for more accurate clinical use. The model assumes that RV total power output (1) is the sum of isovolumic and stroke power and (2) is linearly related to its right coronary artery oxygen supply. Thus, when right coronary artery flow is limited or isovolumic power is elevated, less energy is available for producing cardiac output. The original and adjusted models were validated via data from patients with idiopathic PAH (n = 14) and large animals (n = 6) that underwent acute pulmonary banding with or without hypoxia. RESULTS: Both models demonstrated strong, significant correlations between RV oxygen consumption rate and RV total power output for PAH patients (original model, R2  = 0.66; adjusted model, R2  = 0.78) and sheep (original, R2  = 0.85; adjusted, R2  = 0.86). Furthermore, the models demonstrate a significant inverse relationship between required oxygen consumption and RV efficiency (stroke power/total power) (p < 0.001). Lastly, higher NYHA class was indicative of lower RV efficiency and higher oxygen consumption (p = 0.013). CONCLUSION: Right ventricular total power output can be accurately estimated directly from pulmonary hemodynamics and right coronary perfusion during PAH. This model highlights the increased vulnerability of PAH patients with compromised right coronary flow coupled with high afterload.


Assuntos
Hipertensão Pulmonar , Hipertensão Arterial Pulmonar , Acidente Vascular Cerebral , Disfunção Ventricular Direita , Animais , Hemodinâmica , Humanos , Oxigênio , Ovinos , Acidente Vascular Cerebral/complicações , Função Ventricular Direita
10.
Int J Circumpolar Health ; 81(1): 2064597, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35426356

RESUMO

In the spring of 2020, the Alaska Native Tribal Health Consortium (ANTHC) designed and built a sanitizing treatment system to address shortages of filtering facepiece respirators (FFRs). The design criteria included sanitizing large numbers of FFRs, repeatedly achieving FFR fit test requirements, and deactivating enveloped respiratory viruses, such as SARS-CoV-2. The outcome was the Mobile Sanitizing Trailer (MST), a 20 by 8-foot modified trailer designed to process up to 1,000 FFRs during a standard heat cycle. This paper reports on the MST's ability to: (1) sustain a target temperature, (2) produce tolerable conditions for FFRs as measured by fit factor and (3) successfully deactivate an infectious model virus. We found that the MST reliably and uniformly produced 75 degrees Celsius in the treatment chamber for the prescribed periods. Quantitative analysis showed that the FFRs achieved acceptable post-treatment fit factor even after 18, 60-minute heat cycles. Finally, the treated FFR materials had at least a log 3.0 reduction in viral RNA and no viable virus after 30, 60 or 90 minutes of heat treatment. As a sanitizing treatment during supply shortages, we found the MST a viable option for deactivation of virus and extending the usable life of FFRs.


Assuntos
COVID-19 , Vírus , Calefação , Humanos , SARS-CoV-2 , Ventiladores Mecânicos
11.
ASAIO J ; 68(2): e29-e33, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33883506

RESUMO

Decompensated right ventricular failure (RVF) in patients with pulmonary hypertension (PH) is fatal, with limited treatment options. Novel mechanical circulatory support systems have therapeutic potential for RVF, but the development of these devices requires a large animal disease model that replicates the pathophysiology observed in humans. We previously reported an effective disease model of PH in sheep through ligation of the left pulmonary artery (PA) and progressive occlusion of the main PA. Herein, we report a case of acute decompensation with this model of chronic RVF. Gradual PA banding raised the RV pressure (maximum RV systolic/mean pressure = 95 mmHg/56 mmHg). Clinical findings and laboratory serum parameters suggested appropriate physiologic compensation for 7 weeks. However, mixed venous saturation declined precipitously on week 7, and creatinine increased markedly on week 9. By the 10th week, the animal developed dependent, subcutaneous edema. Subsequently, the animal expired during the induction of general anesthesia. Post-mortem evaluation revealed several liters of pleural effusion and ascites, RV dilatation, eccentric RV hypertrophy, and myocardial fibrosis. The presented case supports this model's relevance to the human pathophysiology of RVF secondary to PH and its value in the development of novel devices, therapeutics, and interventions.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Disfunção Ventricular Direita , Animais , Modelos Animais de Doenças , Insuficiência Cardíaca/etiologia , Humanos , Hipertensão Pulmonar/etiologia , Hipertrofia Ventricular Direita/etiologia , Artéria Pulmonar , Ovinos , Disfunção Ventricular Direita/etiologia
12.
J Vis Exp ; (173)2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34338672

RESUMO

Decompensated right ventricular failure (RVF) in pulmonary hypertension (PH) is fatal, with limited medical treatment options. Developing and testing novel therapeutics for PH requires a clinically relevant large animal model of increased pulmonary vascular resistance and RVF. This manuscript discusses the latest development of the previously published ovine PH-RVF model that utilizes left pulmonary artery (PA) ligation and main PA occlusion. This model of PH-RVF is a versatile platform to control not only the disease severity but also the RV's phenotypic response. Adult sheep (60-80 kg) underwent left PA (LPA) ligation, placement of main PA cuff, and insertion of RV pressure monitor. PA cuff and RV pressure monitor were connected to subcutaneous ports. Subjects underwent progressive PA banding twice per week for 9 weeks with sequential measures of RV pressure, PA cuff pressures, and mixed venous blood gas (SvO2). At the initiation and endpoint of this model, ventricular function and dimensions were assessed using echocardiography. In a representative group of 12 animal subjects, RV mean and systolic pressure increased from 28 ± 5 and 57 ± 7 mmHg at week 1, respectively, to 44 ± 7 and 93 ± 18 mmHg (mean ± standard deviation) by week 9. Echocardiography demonstrated characteristic findings of PH-RVF, notably RV dilation, increased wall thickness, and septal bowing. The longitudinal trend of SvO2 and PA cuff pressure demonstrates that the rate of PA banding can be titrated to elicit varying RV phenotypes. A faster PA banding strategy led to a precipitous decline in SvO2 < 65%, indicating RV decompensation, whereas a slower, more paced strategy led to the maintenance of physiologic SvO2 at 70%-80%. One animal that experienced the accelerated strategy developed several liters of pleural effusion and ascites by week 9. This chronic PH-RVF model provides a valuable tool for studying molecular mechanisms, developing diagnostic biomarkers, and enabling therapeutic innovation to manage RV adaptation and maladaptation from PH.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Disfunção Ventricular Direita , Animais , Modelos Animais de Doenças , Hipertensão Pulmonar/etiologia , Artéria Pulmonar/cirurgia , Ovinos , Disfunção Ventricular Direita/etiologia , Função Ventricular Direita
13.
J Transl Med ; 19(1): 179, 2021 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-33910585

RESUMO

BACKGROUND: Extracorporeal membrane oxygenation (ECMO) research using large animals requires a significant amount of resources, slowing down the development of new means of ECMO anticoagulation. Therefore, this study developed and evaluated a new rat ECMO model using a 3D-printed mock-oxygenator. METHODS: The circuit consisted of tubing, a 3D-printed mock-oxygenator, and a roller pump. The mock-oxygenator was designed to simulate the geometry and blood flow patterns of the fiber bundle in full-scale oxygenators but with a low (2.5 mL) priming volume. Rats were placed on arteriovenous ECMO at a 1.9 mL/min flow rate at two different heparin doses (n = 3 each): low (15 IU/kg/h for eight hours) versus high (50 IU/kg/h for one hour followed by 25 IU/kg/h for seven hours). The experiment continued for eight hours or until the mock-oxygenator failed. The mock-oxygenator was considered to have failed when its blood flow resistance reached three times its baseline resistance. RESULTS: During ECMO, rats maintained near-normal mean arterial pressure and arterial blood gases with minimal hemodilution. The mock-oxygenator thrombus weight was significantly different (p < 0.05) between the low (0.02 ± 0.006 g) and high (0.003 ± 0.001 g) heparin delivery groups, and blood flow resistance was also larger in the low anticoagulation group. CONCLUSIONS: This model is a simple, inexpensive system for investigating new anticoagulation agents for ECMO and provides low and high levels of anticoagulation that can serve as control groups for future studies.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Animais , Heparina/farmacologia , Oxigenadores , Impressão Tridimensional , Ratos
14.
Biomaterials ; 272: 120778, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33812214

RESUMO

Blood contact with high surface area medical devices, such as dialysis and extracorporeal life support (ECLS), induces rapid surface coagulation. Systemic anticoagulation, such as heparin, is thus necessary to slow clot formation, but some patients suffer from bleeding complications. Both problems might be reduced by 1) replacing heparin anticoagulation with artificial surface inhibition of the protein adsorption that initiates coagulation and 2) selective inhibition of the intrinsic branch of the coagulation cascade. This approach was evaluated by comparing clot formation and bleeding times during short-term ECLS using zwitterionic polycarboxybetaine (PCB) surface coatings combined with either a potent, selective, bicyclic peptide inhibitor of activated Factor XII (FXII900) or standard heparin anticoagulation. Rabbits underwent venovenous ECLS with small sham oxygenators for 60 min using three means of anticoagulation (n = 4 ea): (1) PCB coating + FXII900 infusion, (2) PCB coating + heparin infusion with an activated clotting time of 220-300s, and (3) heparin infusion alone. Sham oxygenator blood clot weights in the PCB + FXII900 and PCB + heparin groups were 4% and 25% of that in the heparin group (p < 10-6 and p < 10-5), respectively. At the same time, the bleeding time remained normal in the PCB + FXII900 group (2.4 ± 0.2 min) but increased to 4.8 ± 0.5 and 5.1 ± 0.7 min in the PCB + heparin and heparin alone groups (p < 10-4 and 0.01). Sham oxygenator blood flow resistance was significantly lower in the PCB + FXII900 and PCB + heparin groups than in the heparin only group (p < 10-6 and 10-5). These results were confirmed by gross and scanning electron microscopy (SEM) images and fibrinopeptide A (FPA) concentrations. Thus, the combined use of PCB coating and FXII900 markedly reduced sham oxygenator coagulation and tissue bleeding times versus the clinical standard of heparin anticoagulation and is a promising anticoagulation method for clinical ECLS.


Assuntos
Anticoagulantes/farmacologia , Oxigenação por Membrana Extracorpórea , Fator XII/antagonistas & inibidores , Animais , Betaína , Coagulação Sanguínea , Heparina/farmacologia , Humanos , Ácidos Polimetacrílicos , Coelhos , Diálise Renal
15.
Adv Healthc Mater ; 10(10): e2100048, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33738976

RESUMO

A patient's capacity for tissue regeneration varies based on age, nutritional status, disease state, lifestyle, and gender. Because regeneration cannot be predicted prior to biomaterial implantation, there is a need for responsive biomaterials with adaptive, personalized degradation profiles to improve regenerative outcomes. This study reports a new approach to use therapeutic ultrasound as a means of altering the degradation profile of silk fibroin biomaterials noninvasively postimplantation. By evaluating changes in weight, porosity, surface morphology, compressive modulus, and chemical structure, it is concluded that therapeutic ultrasound can trigger enhanced degradation of silk fibroin scaffolds noninvasively. By removing microbubbles on the scaffold surface, it is found that acoustic cavitation is the mechanism responsible for changing the degradation profile. This method is proved to be safe for human cells with no negative effects on cell viability or metabolism. Sonication through human skin also effectively triggers scaffold degradation, increasing the clinical relevance of these results. These findings suggest that silk is an ultrasound-responsive biomaterial, where the degradation profile can be adjusted noninvasively to improve regenerative outcomes.


Assuntos
Fibroínas , Materiais Biocompatíveis , Humanos , Porosidade , Seda , Engenharia Tecidual , Alicerces Teciduais
16.
ASAIO J ; 67(1): e44-e48, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33346995

RESUMO

Pulmonary hypertension (PH) is a progressive disease that leads to cardiopulmonary dysfunction and right heart failure from pressure and volume overloading of the right ventricle (RV). Mechanical cardiopulmonary support has theoretical promise as a bridge to organ transplant or destination therapy for these patients. Solving the challenges of mechanical cardiopulmonary support for PH and RV failure requires its testing in a physiologically relevant animal model. Previous PH models in large animals have used pulmonary bead embolization, which elicits unpredictable inflammatory responses and has a high mortality rate. We describe a step-by-step guide for inducing pulmonary hypertension and right ventricular hypertrophy (PH-RVH) in sheep by left pulmonary artery (LPA) ligation combined with progressive main pulmonary artery (MPA) banding. This approach provides a controlled method to regulate RV afterload as tolerated by the animal to achieve PH-RVH, while reducing acute mortality. This animal model can facilitate evaluation of mechanical support devices for PH and RV failure.


Assuntos
Modelos Animais de Doenças , Hipertensão Pulmonar , Hipertrofia Ventricular Direita , Disfunção Ventricular Direita , Animais , Hipertensão Pulmonar/fisiopatologia , Hipertrofia Ventricular Direita/fisiopatologia , Ligadura , Masculino , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/cirurgia , Ovinos , Disfunção Ventricular Direita/fisiopatologia
17.
Pain Res Manag ; 2020: 5982567, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32774566

RESUMO

EXPAREL® has been used successfully to prolong postoperative pain control when applied as a wound infiltrate. EXPAREL® has not yet been approved for use in regional anesthesia to prolong postoperative pain control. We conducted a clinical case series of 4 patients using EXPAREL® for sciatic blocks via the popliteal fossa approach. Our results suggested that there is a large degree of variability in response to the medication. These inconsistent results and the possibility of bimodal kinetics creating analgesic gaps as seen in two of our patients indicate that more studies with larger sample size are needed to better characterize these phenomena and determine if more consistent results can be obtained in a future clinical trial.


Assuntos
Anestésicos Locais , Bupivacaína , Bloqueio Nervoso/métodos , Redução Aberta/efeitos adversos , Dor Pós-Operatória/prevenção & controle , Traumatismos do Tornozelo/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Redução Aberta/métodos , Manejo da Dor/métodos , Estudos Prospectivos
18.
Nat Commun ; 11(1): 3890, 2020 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-32753636

RESUMO

Inhibiting thrombosis without generating bleeding risks is a major challenge in medicine. A promising solution may be the inhibition of coagulation factor XII (FXII), because its knock-out or inhibition in animals reduced thrombosis without causing abnormal bleeding. Herein, we have engineered a macrocyclic peptide inhibitor of activated FXII (FXIIa) with sub-nanomolar activity (Ki = 370 ± 40 pM) and a high stability (t1/2 > 5 days in plasma), allowing for the preclinical evaluation of a first synthetic FXIIa inhibitor. This 1899 Da molecule, termed FXII900, efficiently blocks FXIIa in mice, rabbits, and pigs. We found that it reduces ferric-chloride-induced experimental thrombosis in mice and suppresses blood coagulation in an extracorporeal membrane oxygenation (ECMO) setting in rabbits, all without increasing the bleeding risk. This shows that FXIIa activity is controllable in vivo with a synthetic inhibitor, and that the inhibitor FXII900 is a promising candidate for safe thromboprotection in acute medical conditions.


Assuntos
Anticoagulantes/farmacologia , Coagulação Sanguínea/efeitos dos fármacos , Fator XIIa/antagonistas & inibidores , Peptídeos Cíclicos/efeitos dos fármacos , Trombose/prevenção & controle , Animais , Cloretos/efeitos adversos , Clonagem Molecular , Modelos Animais de Doenças , Descoberta de Drogas , Oxigenação por Membrana Extracorpórea/métodos , Fator XII/antagonistas & inibidores , Feminino , Compostos Férricos/efeitos adversos , Humanos , Pulmão , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Coelhos , Proteínas Recombinantes/farmacologia , Suínos
19.
ASAIO J ; 66(9): 1054-1062, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32149748

RESUMO

Microchannel artificial lungs may provide highly efficient, long-term respiratory support, but a robust predictive oxygen transfer (VO2) model is needed to better design them. To meet this need, we first investigated the predictive accuracy of Mikic, Benn, and Drinker's advancing front (AF) oxygen transfer theory by applying it to previous microchannel lung studies. Here, the model that included membrane resistance showed no bias toward overprediction or underprediction of VO2 (median error: -1.13%, interquartile range: [-26.9%, 19.2%]) and matched closely with existing theory. Next, this theory was expanded into a general model for investigating a family of designs. The overall model suggests that, for VO2 = 100 ml/min, fraction of delivered oxygen (FDO2) = 40%, wall shear stress ((Equation is included in full-text article.)) = 30 dyn/cm, and blood channel height = 20-50 µm, a compact design can be achieved with priming volume ((Equation is included in full-text article.)) = 5.8-32 ml; however, manifolding may be challenging to satisfy the rigorous total width ((Equation is included in full-text article.)) requirement ((Equation is included in full-text article.)= 76-475 m). In comparison, 100-200 µm heights would yield larger dimensions ((Equation is included in full-text article.)122-478 ml) but simpler manifolding ((Equation is included in full-text article.)4.75-19.0 m). The device size can be further adjusted by varying FDO2, (Equation is included in full-text article.), or VO2. This model may thus serve as a simple yet useful tool to better design microchannel artificial lungs.


Assuntos
Órgãos Artificiais , Desenho de Equipamento , Pulmão , Modelos Biológicos
20.
Transl Res ; 211: 1-18, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31103468

RESUMO

Chronic lung disease is the 4th leading cause of death in the United States. Due to a shortage of donor lungs, alternative approaches to support failing, native lungs have been attempted, including mechanical ventilation and various forms of artificial lungs. However, each of these support methods causes significant complications when used for longer than a few days and are thus not capable of long-term support. For artificial lungs, complications arise due to interactions between the artificial materials of the device and the blood of the recipient. A potential new approach is the fabrication of lungs from biological materials, such that the gas exchange membranes provide a more biomimetic blood-contacting interface. Recent advancements with three-dimensional, soft-tissue biofabrication methods and the engineering of thin, basement membranes demonstrate the potential of fabricating a lung scaffold from extracellular matrix materials. This scaffold could then be seeded with endothelial and epithelial cells, matured within a bioreactor, and transplanted. In theory, this fully biological lung could provide improved, long-term biocompatibility relative to artificial lungs, but significant work is needed to perfect the organ design and construction methods. Like artificial lungs, biofabricated lungs do not need to follow the shape and structure of a native lung, allowing for simpler manufacture. However, various functional requirements must still be met, including stable, efficient gas exchange for a period of years. Design decisions depend on the disease state, how the organ is implanted, and the latest biofabrication methods available in a rapidly evolving field.


Assuntos
Órgãos Artificiais , Pulmão , Engenharia Tecidual , Humanos , Alicerces Teciduais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...