Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Soc Cardiovasc Angiogr Interv ; 3(4): 101232, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-39130171

RESUMO

A 58-year-old man presenting with angina was found to have a large coronary aneurysm on angiography. After coronary bypass and multiple ST-elevation myocardial infarctions over the following months, the decision was made to exclude the aneurysm with a flow-diverting stent, which reduced flow to the aneurysm and left the patient asymptomatic since the procedure. This is the first reported use of a cerebral flow-diverting stent for treatment of a coronary aneurysm.

2.
J Neurointerv Surg ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38418227

RESUMO

BACKGROUND: The delivery of neuroendovascular devices requires a robust proximal access platform. This demand has previously been met with a 6Fr long sheath (8Fr guide) that is placed in the proximal internal carotid artery (ICA) or vertebral artery segments. We share our experience with the first 0.088 inch 8Fr guide catheter designed for direct intracranial access. METHODS: We retrospectively reviewed a prospectively maintained IRB-approved institutional database of the senior authors to identify all cases where the TracStar Large Distal Platform (LDP) was positioned within the intracranial vasculature, defined as within or distal to the petrous ICA, vertebral artery (V3) segments, or transverse sinus. Technical success was defined as safe placement of the TracStar LDP within or distal to the described distal vessel segments with subsequent complication-free device implantation. RESULTS: Over the 41-month study period from January 2020 to June 2023, 125 consecutive cases were identified in whom the TracStar LDP was navigated into the intracranial vasculature for triaxial delivery of large devices, 0.027 inch microcatheter and greater, for aneurysm treatment (n=108, 86%), intracranial angioplasty/stenting (n=15, 12%), and venous sinus stenting (n=2, 1.6%). All cases used a direct select catheter technique for initial guide placement (no exchange). Posterior circulation treatments occurred in 14.4% (n=18) of cases. Technical success was achieved in 100% of cases. No vessel dissections occurred in any cases. CONCLUSION: The TracStar LDP is an 0.088 inch 8Fr guide catheter that can establish direct intracranial access with an acceptable safety profile. This can be achieved in a wide range of neurointerventional cases with a high rate of technical success.

3.
Interv Neuroradiol ; : 15910199241229198, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38418397

RESUMO

INTRODUCTION: Superbore 0.088″ catheters provide a platform for optimizing aspiration efficiency and flow control during stroke mechanical thrombectomy procedures. New superbore catheters have the distal flexibility necessary to navigate complex neurovascular anatomy while providing the proximal support of traditional 8F catheters. The safety and feasibility of Zoom 88™ superbore angled-tip catheters in the middle cerebral artery (MCA) segments smaller than the catheter diameter have not been previously described. METHODS: Twenty consecutive cases of acute MCA mechanical thrombectomy were retrospectively identified from the senior authors' prospectively maintained Institutional Review Board-approved database, in which the Zoom 88 (Imperative Care, Campbell, CA) catheter was successfully navigated to at least the M1 segment. Patient demographics, procedural details, and periprocedural information were analyzed. Rates and averages (standard errors) are generally reported. RESULTS: The average National Institutes of Health Stroke Scale at presentation and age were 15 ± 2 and 73 ± 3 years, respectively. The M1 and M2 occlusions were evenly distributed. The average M1 measurements before thrombectomy ranged from 2.36 ± 0.07 mm proximally to 2.00 ± 0.11 mm distally, and after thrombectomy, they ranged from 2.34 ± 0.07 mm proximally to 1.97 ± 0.10 mm distally. First-pass modified thrombolysis in cerebral infarction (mTICI) 2C/3 recanalization was achieved in 40% of cases, and final mTICI 2C/3 recanalization was achieved in 90% of cases. A single case of mild vasospasm was managed with verapamil. No hemorrhagic or periprocedural complications were noted. CONCLUSION: Superbore 0.088″ catheters with flexible distal segments can be safely navigated to the MCA to augment mechanical thrombectomy even when the MCA segment is smaller than the catheter.

4.
J Neurol Surg Rep ; 85(1): e17-e22, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38348015

RESUMO

Formation of a carotid free-floating thrombus (CFFT) is a rare and life-threatening condition without an optimal management plan. A 78-year-old woman with a history of prior right internal carotid artery (ICA) mechanical thrombectomy and antiplatelet noncompliance presented with transient ischemic attacks secondary to a recurrent CFFT in the right ICA. Given her symptoms and recurrent CFFT, endovascular mechanical thrombectomy was performed. A balloon guide-catheter (BGC) and a Zoom 88 distal access catheter were brought into the right distal common carotid artery and proximal ICA bulb, respectively. Three 0.021-inch microcatheters, each loaded with a unique stentriever, were navigated beyond the thrombus into the upper cervical ICA and deployed in a bouquet fashion. The BGC was inflated to achieve flow arrest, and the Zoom 88 aspiration catheter was tracked over the three bouquet stentrievers to ingest the thrombus. Follow-up angiography demonstrated recanalization of the proximal cervical ICA without evidence of residual thrombus. Twenty-four-hour postoperative computed tomography imaging did not reveal any evidence of new infarction. The patient was discharged home with an intact neurological examination, compliant on aspirin and apixaban. We demonstrate a novel technique utilizing a large-bore catheter with a triple stentriever "bouquet" to thrombectomize a CFFT.

5.
Interv Neuroradiol ; : 15910199231224003, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166510

RESUMO

BACKGROUND: Endovascular embolization of the middle meningeal artery (MMA) has emerged as an adjunctive and stand-alone modality for the management of chronic subdural hematomas (cSDH). We report our experience utilizing proximal MMA coil embolization to augment cSDH devascularization in MMA embolization. METHODS: MMA embolization cases with adjunctive proximal MMA coiling were retrospectively identified from a prospectively maintained IRB-approved database of the senior authors. RESULTS: Of the 137 cases, all patients (n = 89, 100%) were symptomatic and underwent an MMA embolization procedure for cSDH. 50 of the patients underwent bilateral embolizations, with 53% (n = 72) for left-sided and 47% (n = 65) for right-sided cSDH. The anterior MMA branch was embolized in 19 (14%), posterior in 16 (12%), and both in 102 (74.5%) cases. Penetration of the liquid embolic to the contralateral MMA or into the falx was present in 38 (28%) and 31 (23%) cases, respectively, and 46 (34%) cases had ophthalmic or petrous collateral (n = 41, 30%) branches. MMA branches coiled include the primary trunk (25.5%, n = 35), primary and anterior or posterior MMA trunks (20%, n = 28), or primary with the anterior and posterior trunks (54%, n = 74). A mild ipsilateral facial nerve palsy was reported, which remained stable at discharge and follow-up. Absence of anterograde flow in the MMA occurred in 137 (100%) cases, and no cases required periprocedural rescue surgery for cSDH evacuation. The average follow-up length was 170 ± 17.9 days, cSDH was reduced by 4.24 ± 0.5(mm) and the midline shift by 1.46 ± 0.27(mm). Complete resolution was achieved in 63 (46.0%) cases. CONCLUSION: Proximal MMA coil embolization is a safe technique for providing additional embolization/occlusion of the MMA in cSDH embolization procedures. Further studies are needed to evaluate the potential added efficacy of this technique.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA