Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 177
Filtrar
1.
Proc Inst Mech Eng H ; 223(2): 133-42, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19278191

RESUMO

While researchers have suggested that joint mobility would probably be affected by age and gender, research findings often present discrepancies. Little research has been performed on the factors which effect mobility of the trapeziometacarpal (TMC) joint. The purpose of this study was to address the effects of age and gender on the ranges of motion of the normal TMC joint. Eighty normal subjects divided into four age groups participated in this study. The TMC joint motions were recorded using an electromagnetic tracking system. In order to achieve a maximal range of TMC joint motion which was defined as the maximal workspace, each subject was asked to perform actively maximal circumduction, flexion-extension, and abduction-adduction of the TMC joint. Numerical and statistical methods were used to compute the TMC workspace and to detect significant differences. A workspace-to-length ratio was determined as an index to examine the effects of the age and gender on the joint mobility. The results demonstrated that age and gender had significant influences on the TMC workspace among the groups studied. The understanding of TMC joint mobility under different age and gender conditions is achieved through this study. The findings can be used to report clinical measures in the determination of the extent of impairment of osteoarthritis as well as the outcomes between pre- and post-surgical (or non-surgical) interventions.


Assuntos
Envelhecimento/fisiologia , Articulações dos Dedos/fisiologia , Ossos Metacarpais/fisiologia , Movimento/fisiologia , Amplitude de Movimento Articular/fisiologia , Polegar/fisiologia , Trapézio/fisiologia , Adolescente , Adulto , Fatores Etários , Idoso , Criança , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Fatores Sexuais , Análise e Desempenho de Tarefas , Adulto Jovem
2.
Z Orthop Unfall ; 145(2): 199-206, 2007.
Artigo em Alemão | MEDLINE | ID: mdl-17492561

RESUMO

AIM: Prosthetic replacement in the hand must address such unique challenges as preservation of the collateral ligaments, tendon balancing,and Stability. Surface replacement arthroplasty can be an alternative to other current implants. The purpose of this study was to evaluate the metacarpophalangeal joint kinematics after surface replacement arthroplasty. METHOD: The kinematics of pyrolytic carbon as a surface replacement implant for the metacarpophalangeal joint (MCP) was compared with the intact MCP joint in eight fresh cadaver long fingers by means of an electromagnetic tracking system (Polhemus, Colchester, VT). The eight human cadaver MCP joints were tested before implantation, after implantation, after collateral ligaments resection, and after collateral ligaments reconstruction. RESULTS: The kinematics of the MCP joint is reproduced by the joint surface replacement arthroplasty when normal ligament tension was present. The maximum angular displacement of the pyrocarbon implant was 378 for lateral deviation and 338 for rotation during the passive flexion and extension motion. The instantaneus center of rotation (ICR) after implant insertion was nearly identical to the center of rotation of the normal joint. The results also indicated that the collateral ligaments provide the primary stability of the MCP joint. No significant differences in lateral and rotational stability after surface replacement arthroplasty were noted. While collateral ligaments resection significantly affected the stability of the MCP joint. CONCLUSION: The ICR of the pyrocarbon implant most closely matched that of the intact MCP joint. The pyrocarbon implant provides suitable stability to radio-ulnar deviation and rotational stresses as a resurfacing implant and it simulates the kinematics of the intact MCP joint. By using new materials and taking the anatomical and biomechanical requirements into consideration, the endoprosthesis of the finger joints has created an option to achieve good long-term results. The inadequate results of earlier and current prostheses are a consequence of their mechanical construction and their materials. The success of the new implants could be proven by preferably long-term, controlled studies.


Assuntos
Artroplastia de Substituição de Dedo/instrumentação , Artroplastia de Substituição de Dedo/métodos , Distinções e Prêmios , Instabilidade Articular/fisiopatologia , Articulação Metacarpofalângica/fisiopatologia , Articulação Metacarpofalângica/cirurgia , Fenômenos Biomecânicos/história , Cadáver , Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Alemanha , História do Século XXI , Humanos , Técnicas In Vitro , Instabilidade Articular/etiologia , Minnesota , Ortopedia/história , Amplitude de Movimento Articular , Estresse Mecânico , Resultado do Tratamento
3.
J Hand Surg Am ; 31(10): 1697; author reply 1697, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17145395
4.
Proc Inst Mech Eng H ; 218(2): 143-9, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15116901

RESUMO

The specific aim of this study was to develop a quantitative method and a kinematic method to evaluate the maximal workspace of the trapeziometacarpal (TM) joint. Six fresh-frozen human cadaver hands were disarticulated 4 cm proximal to the wrist joint and used in this experiment. The three-dimensional motion data of the TM joint was collected by an electromagnetic tracking device at 30 Hz. The workspace was reconstructed according to a complete set of motion data included circumduction, flexion-extension and abduction-adduction. A spherical fitting technique was used to obtain a sphere encompassing all the motion trajectories and estimating the centre of the sphere. The surface area of the maximal TM workspace, located on the one part of the sphere surface, was calculated by surface integration. The interclass correlation coefficient values for the reliability estimation of the repeated measurements of the radius and surface area of all specimens were 0.91 and 0.98 respectively. The mean coefficients of variance of the measured radius and the surface area were 2.04 per cent and 3.65 per cent respectively. The results also showed that using a spherical model to calculate the maximal workspace as an index for assessing TM joint impairment is practical.


Assuntos
Algoritmos , Articulações dos Dedos/fisiologia , Modelos Biológicos , Movimento/fisiologia , Amplitude de Movimento Articular/fisiologia , Polegar/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/métodos , Cadáver , Simulação por Computador , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Handchir Mikrochir Plast Chir ; 36(2-3): 126-36, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15162310

RESUMO

Duplication or polydactyly of the thumb is among the most common congenital deformities that involve the hand. The purpose of this presentation is to review the Mayo Clinic experience with thumb duplication and to present preferred operative procedures to achieve the best clinical outcome and esthetic appearance for the hand. We propose that a combination or "best of parts", utilizing the components of both duplicates with retention of the ulnar duplicate as the base for reconstruction will provide the most functional clinical result. A clinical grading system and analysis of results from our personal experience during two different time frames provides the scientific support for our conclusions that combination procedures are preferred to simple excisions or to central joining of parts as in the Bilhaut-Cloquet procedure.


Assuntos
Polidactilia/diagnóstico , Polegar/anormalidades , Criança , Pré-Escolar , Seguimentos , Humanos , Lactente , Avaliação de Processos e Resultados em Cuidados de Saúde , Polidactilia/classificação , Polidactilia/cirurgia , Procedimentos de Cirurgia Plástica , Polegar/cirurgia
6.
Clin Biomech (Bristol, Avon) ; 18(2): 119-25, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12550810

RESUMO

OBJECTIVE: To compare the intrinsic stability of an unconstrained resurfacing metacarpophalangeal arthroplasty to that of a normal human cadaveric joint. DESIGN: Cadaveric joints and metacarpophalangeal prostheses were studied in a mechanical testing machine at different angles and axial loads to determine the stability ratio in eight directions of movement. BACKGROUND: An unconstrained resurfacing arthroplasty was designed to replicate the normal anatomy with the exception of the proximal component having a greater arc of curvature on its dorsal aspect. METHODS: Eight fresh-frozen cadaveric joints and five different sizes of the AVANTA metacarpophalangeal prosthesis were studied at 0 degrees, 45 degrees and 90 degrees angles of flexion and at eight different directions of motion with three different axial loads (0, 20, 40 N). A 6-component load cell measured the force needed to sublux the joint. The stability ratio was the measured outcome and is defined as ratio of the force of subluxation to the axial force. RESULTS AND CONCLUSIONS: The unconstrained resurfacing arthroplasty has more intrinsic stability than the cadaveric metacarpophalangeal joint in all eight directions tested. RELEVANCE: A major complication of metacarpophalangeal implants is ulnopalmar subluxation. The AVANTA implant is designed to decrease the risk of ulnopalmar subluxation by having a greater arc of curvature on the dorsal aspect of the proximal component. This study shows that the designed implant has greater stability due to the geometry of the implant compared to that of the anatomical joint.


Assuntos
Artroplastia/instrumentação , Análise de Falha de Equipamento/métodos , Instabilidade Articular/fisiopatologia , Prótese Articular/classificação , Articulação Metacarpofalângica/fisiopatologia , Articulação Metacarpofalângica/cirurgia , Artroplastia/métodos , Cadáver , Humanos , Luxações Articulares/fisiopatologia , Falha de Prótese , Amplitude de Movimento Articular , Valores de Referência , Rotação , Estresse Mecânico , Suporte de Carga
7.
J Hand Surg Am ; 26(4): 692-7, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11466646

RESUMO

Trapeziometacarpal (TMC) joint arthritis is a common and debilitating condition of the hand. We defined a radiographic measure of trapezial inclination (trapezial tilt) and found a positive correlation between an increased trapezial tilt and severity of TMC joint arthritis. Radiographs (Robert's views) were obtained from 50 pairs of normal hands to evaluate the trapezial tilt to assess radial inclination of the trapezium with respect to the second metacarpal. The trapezial tilt was also measured in 65 hands from 43 patients with various stages of TMC joint arthritis and compared with the normal value. The trapezial tilt for hands without arthritis was 42 degrees +/- 4 degrees, Eaton stages I and II was 42 degrees +/- 4 degrees, and Eaton stages III and IV was 50 degrees +/- 4 degrees. Trapezial tilt angles from the Eaton III and IV group were significantly greater than those of the normal and Eaton I and II groups. Advanced TMC joint arthritis (Eaton III and IV) is associated with an increased trapezial tilt. Mild TMC joint arthritis with an increased trapezial tilt may be treated surgically. We speculate that a trapezio-trapezoid and trapezio-II metacarpal arthrodesis, or an opening wedge osteotomy of the trapezium might arrest the progression of TMC joint arthritis by resetting the slope of the trapezium and decreasing the shear stress within the TMC joint.


Assuntos
Osteoartrite/diagnóstico por imagem , Osteoartrite/patologia , Polegar/diagnóstico por imagem , Polegar/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/fisiopatologia , Radiografia , Polegar/fisiopatologia
10.
J Hand Surg Am ; 26(2): 271-6, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11279573

RESUMO

Fourteen consecutive patients with acute displaced scaphoid waist fractures were treated with open reduction and internal fixation. The operative technique consisted of anatomic reduction of the displaced scaphoid waist fracture, correction of carpal instability, radial bone grafting for comminution, and internal fixation with K-wires or Herbert screw. The patients were evaluated an average of 26 months (range, 4-48 months) after surgery. Thirteen of the 14 (93%) fractures united. The average time to union was 11.5 weeks (range, 8-20 weeks). Fracture union was confirmed with trispiral tomography. Final radiographic assessment consistently revealed a healed scaphoid fracture, restored intrascaphoid alignment, and no evidence of carpal instability. All patients regained functional wrist range of motion (wrist extension, 57 degrees; wrist flexion, 52 degrees ) and grip strength. Open reduction and internal fixation of acute displaced scaphoid waist fractures restores scaphoid alignment and leads to predictable union. Early operative intervention avoids malunion and carpal instability that often occurs with closed management of these complex fractures.


Assuntos
Ossos do Carpo/lesões , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Traumatismos do Punho/cirurgia , Adolescente , Adulto , Idoso , Parafusos Ósseos , Fios Ortopédicos , Ossos do Carpo/diagnóstico por imagem , Ossos do Carpo/cirurgia , Feminino , Consolidação da Fratura/fisiologia , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular , Resultado do Tratamento , Traumatismos do Punho/diagnóstico por imagem
11.
J Cardiothorac Vasc Anesth ; 15(1): 49-54, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11254840

RESUMO

OBJECTIVE: To determine if the platelet glass bead retention assay can predict bleeding after cardiac surgery. DESIGN: Prospective, observational study. SETTING: Large, tertiary care, academic medical center. PARTICIPANTS: Forty-three adult patients scheduled to undergo elective cardiac surgery employing cardiopulmonary bypass (CPB). MEASUREMENTS AND MAIN RESULTS: Whole blood samples were observed for platelet count, prothrombin time, and platelet (glass bead) retention assay. The platelet retention and prothrombin times were independent univariant and multivariant predictors of bleeding after CPB (r = 0.554, p = 0.0002 and r = 0.655, p = 0.00001). CONCLUSION: The platelet glass bead retention assay measures dynamic platelet function and is sensitive to the CPB-induced adhesion and aggregation defect and correlates with postoperative blood loss. Modification of this platelet function assay used with the prothrombin time may provide a simple and effective diagnostic approach to bleeding after CPB.


Assuntos
Plaquetas/fisiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Testes de Função Plaquetária/métodos , Complicações Pós-Operatórias/sangue , Hemorragia Pós-Operatória/sangue , Idoso , Análise de Variância , Anticoagulantes/uso terapêutico , Ponte Cardiopulmonar , Feminino , Heparina/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Tromboplastina Parcial , Contagem de Plaquetas , Valor Preditivo dos Testes , Tempo de Protrombina
13.
J Hand Surg Am ; 26(1): 85-93, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11172373

RESUMO

We investigated the influence of radial styloidectomy on carpal alignment and examined translation of the wrist after sequentially increased styloidectomy of 8 cadaver wrists. The radial aspect of the scaphoid fossa of the distal radius was cut obliquely at 3, 6, and 10 mm from the radial styloid guided by real-time fluoroscopy. Radiographic analysis of the changes of carpal alignment was performed with the wrist in neutral position. Force-displacement curves from the neutral to the radioulnar and palmar-dorsal directions were obtained using a multi-axis testing machine. Results demonstrated no significant malalignment of the carpal bones after radial styloidectomy. Significantly increased radial translation (>40% reduction in stiffness), however, was observed due to the loss of radial articular contact after 6- and 10-mm radial styloidectomies. Significant ulnar and palmar carpal displacement also was noted after 6- and 10-mm radial styloidectomies, with 6 specimens demonstrating moderate ulnar and palmar translation and 2 demonstrating notable increased palmar and ulnar translations. We conclude that there is a definite risk of increased carpal instability with radial styloidectomy procedures. A styloidectomy of no more than 3 to 4 mm is recommended.


Assuntos
Ossos do Carpo/fisiopatologia , Instabilidade Articular/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Rádio (Anatomia)/cirurgia , Articulação do Punho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Ossos do Carpo/diagnóstico por imagem , Feminino , Humanos , Instabilidade Articular/diagnóstico por imagem , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Radiografia , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/fisiopatologia
15.
J Hand Surg Am ; 25(6): 1085-95, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11119667

RESUMO

Destabilization of the trapezium from its normal orientation with respect to the trapezoid, second metacarpal, and thumb metacarpal leads to incongruity at the trapeziometacarpal (TMC) joint. Abnormal shear forces may eventually result in TMC joint arthritis. By determining the relative stiffness and strength of the ligaments that stabilize this joint, one may infer their role in providing stability to the TMC joint. This study addresses the material properties of the ligaments stabilizing the trapezium and TMC joint to better understand the mechanics and kinematics of this joint. Fresh-frozen cadaveric hands (10 males and 10 females) were used to obtain bone-ligament-bone complexes from the dorsal and volar trapeziotrapezoid ligaments, dorsal and volar trapezio-second metacarpal ligaments, anterior oblique ligament, dorsoradial ligament, and trapezio-third metacarpal (T-III MC) ligament. The following material properties were derived from our data: ultimate load, ultimate stress (normalized failure load), ultimate strain (percent elongation), stiffness, toughness (energy to failure), and hysteresis. The dorsoradial ligament demonstrated the greatest ultimate load and toughness (energy to failure). The T-III MC ligament demonstrated the greatest ultimate stress (normalized failure load) and stiffness. The anterior oblique ligament demonstrated the least stiffness and the greatest hysteresis. The material properties of capsuloligamentous structures may be a good indicator of their importance to joint stability. Using these criteria we conclude that the T-III MC and dorsoradial ligaments are important stabilizers of the trapezium and TMC joint, respectively. These two ligaments were found to be the strongest, stiffest, and toughest ligaments, while the anterior oblique ligament was relatively weak and compliant. The dorsal trapezio-second metacarpal, volar trapezio-second metacarpal, and T-III MC ligaments were all relatively strong and are anatomically aligned to function as tension bands to restrain the trapezium against cantilever bending forces applied to it by the thumb during key or tip pinch.


Assuntos
Ligamentos Articulares/fisiologia , Metacarpo/fisiologia , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Articulação do Punho/fisiologia
16.
Sports Med ; 30(6): 423-37, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11132124

RESUMO

BACKGROUND: The 'yips' is a psychoneuromuscular impediment affecting execution of the putting stroke in golf. Yips symptoms of jerks, tremors and freezing often occur during tournament golf and may cause performance problems. Yips-affected golfers add approximately 4.7 strokes to their scores for 18 holes of golf, and have more forearm electromyogram activity and higher competitive anxiety than nonaffected golfers in both high and low anxiety putting conditions. The aetiology of the yips is not clear. OBJECTIVE: To determine whether the yips is a neurological problem exacerbated by anxiety, or whether the behaviour is initiated by anxiety and results in a permanent neuromuscular impediment. METHODS: In phase I, golf professionals assisted investigators in developing a yips questionnaire that was sent to tournament players (<12 handicap) to establish the prevalence and characteristics of the yips. Phase II measured putting behaviour in scenarios that contribute to the yips response. Four self-reported yips and 3 nonaffected golfers putted 3 scenarios using an uncorrected grip and a standard length putter. Heart rate was superimposed on the videotape and the putter grip was instrumented with strain gauges to measure grip force. Electromyograms and relative putting performance were also measured. RESULTS: The questionnaire was sent to 2,630 tournament players, of whom 1,031 (39%) responded (986 men and 45 women). Of these, 541 (52%) perceived they experienced the yips compared with 490 (48%) who did not. Yips-affected golfers reported that the most troublesome putts were 3, 4 and 2 feet (0.9, 1.2 and 0.6 metres) from the hole. Fast, downhill, left-to-right breaking putts and tournament play also elicited the yips response. Golfers affected by the yips had a faster mean heart rate, increased electromyogram activity patterns and exerted more grip force than nonrffected golfers and had a poorer putting performance. CONCLUSIONS: For <10 handicap male golfers and <12 handicap female golfers, the prevalence of the yips is between 32.5% and 47.7%, a high proportion of serious golfers. This high prevalence suggests that medical practitioners need to understand the aetiology of the yips phenomenon so that interventions can be identified and tested for effectiveness in alleviating symptoms. Although previous investigators concluded that the yips is a neuromuscular impediment aggravated but not caused by anxiety, we believe the yips represents a continuum on which 'choking' (anxiety-related) and dystonia symptoms anchor the extremes. The aetiology may well be an interaction of psychoneuromuscular influences. Future research to test the effect of medications such as beta-blockers should assist in better identifying the contributions these factors make to the yips phenomenon.


Assuntos
Ansiedade/complicações , Golfe/fisiologia , Golfe/psicologia , Músculo Esquelético/inervação , Adaptação Fisiológica , Adaptação Psicológica , Eletromiografia , Feminino , Humanos , Masculino , Prognóstico , Medição de Risco , Inquéritos e Questionários
17.
J Cardiothorac Vasc Anesth ; 14(2): 177-81, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10794338

RESUMO

OBJECTIVE: To determine the blood loss associated with coronary angiography and its impact on hemoglobin and transfusion requirements for subsequent coronary artery bypass graft (CABG) surgery. DESIGN: Retrospective chart review. SETTING: Tertiary-care, academic medical center. PARTICIPANTS: A total of 506 adult patients undergoing coronary angiography and CABG surgery. INTERVENTIONS: None (observational study). MEASUREMENTS AND MAIN RESULTS: Coronary angiography was associated with a reduction in hemoglobin of 1.8 g/dL. This reduction in hemoglobin was a significant predictor of allogeneic red blood cell transfusion. CONCLUSION: Coronary angiography contributes to a 1.8 g/dL reduction in hemoglobin concentration before CABG surgery and was associated with increased transfusion of allogeneic blood products. Measures aimed at maintaining red cell volume during coronary angiography, increasing erythropoiesis, or delaying surgery beyond 2 weeks may result in a decrease in transfusion requirements for patients undergoing CABG surgery.


Assuntos
Perda Sanguínea Cirúrgica/fisiopatologia , Transfusão de Sangue , Angiografia Coronária/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Volume Sanguíneo/fisiologia , Transfusão de Eritrócitos , Eritropoese , Feminino , Hemoglobinas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
18.
J Hand Surg Am ; 25(2): 305-12, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10722823

RESUMO

Nine fresh-frozen normal human cadaveric long fingers were used to compare the kinematics of the proximal interphalangeal joint (PIP) before and after a resurfacing metal-polyethylene prosthetic replacement (Avanta prosthesis, San Diego, CA) using the magnetic Isotrak system (Polhemus Navigational Systems, Colchester, VT). The kinematics of the PIP joint after replacement were similar to that of the normal joint. The maximum angular displacement was 5 degrees for lateral deviation and 9 degrees for rotation during the passive flexion and extension motion. The center of rotation after implant insertion was nearly identical to the center of rotation of the normal joint. This anatomically designed PIP prosthesis has potential to restore normal motion to the finger PIP joint while resisting physiologic out-of-plane forces such as pinch and grasp.


Assuntos
Artroplastia de Substituição/métodos , Articulações dos Dedos/cirurgia , Prótese Articular , Fenômenos Biomecânicos , Cadáver , Articulações dos Dedos/diagnóstico por imagem , Articulações dos Dedos/fisiologia , Humanos , Probabilidade , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Valores de Referência , Rotação , Estresse Mecânico
19.
Handchir Mikrochir Plast Chir ; 32(6): 411-8, 2000 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-11189895

RESUMO

Pain, weakness, malalignment and limited range of motion (ROM) at the PIP joint following arthrosis (degenerative or post-traumatic) or rheumatoid arthritis frequently require surgical treatment. PIP joint fusion or implantation of a prosthetic device are options. The purpose of this study was to report our long-term results with a surface replacement PIP arthroplasty (SR PIP arthroplasty) and the description of our operative technique. 82 prostheses were done in 60 patients between 1980 and 1999. All patients were reexamined, the average follow up was 64 months (12 to 260 months); average age was 57 years. 48 patients were operated on the right hand, 12 on the left hand. 44 patients were female, 16 were male. All patients complained of pain preoperatively. Patients were divided into three groups: A degenerative arthrosis, B posttraumatic arthrosis and C inflammatory arthritis. Active range of motion of all fingers of the operated hand, grip-strength, pain relief, joint stability or deformity and comprehensive radiographic assessment were studied. The subjective impressions of the patients were measured in four grades: very satisfied--satisfied--dissatisfied--very dissatisfied. Finally the investigators divided the overall results in: good--fair--poor. The average flexion arc was 31 degrees (maximum 15 degrees hyperextension to 95 degrees flexion) preoperatively and 47 degrees (maximum 14 degrees hyperextension to 90 degrees flexion) postoperatively. Over 70% of the patients had complete pain relief. In 12 fingers secondary procedures were necessary, usually related to soft tissue deformity and extensor tendon function. No arthrodesis was performed as a following operation. In 40 fingers a good result was achieved (49%), 25 had a fair (30%) and 17 (21%) a poor result. Our results of resurfacing PIP arthroplasty are encouraging and provide equal and usually improved motion in comparison with other joints. With experience and refinements of the operative technique our confidence in surface replacement arthroplasty has increased. For this reason we prefer this procedure for posttraumatic or degenerative arthrosis as against PIP joint fusion or silastic implants.


Assuntos
Articulações dos Dedos/cirurgia , Prótese Articular , Osteoartrite/cirurgia , Idoso , Feminino , Articulações dos Dedos/diagnóstico por imagem , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Desenho de Prótese , Radiografia , Reoperação
20.
J Hand Surg Am ; 24(4): 786-98, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10447171

RESUMO

We provide a detailed and comprehensive anatomic description of the ligaments stabilizing the trapezium and trapeziometacarpal joint. Sixteen ligaments were identified. Fourteen ligaments inserted onto the trapezium and 2 others attached independently to the thumb metacarpal. The ligaments inserting onto the trapezium were the superficial anterior oblique, deep anterior oblique (beak ligament), dorsoradial, posterior oblique, ulnar collateral, dorsal trapezio-trapezoid, volar trapezio-trapezoid, dorsal trapezio-second metacarpal, volar trapezio-second metacarpal, trapezio-third metacarpal, volar scaphotrapezial, radial scaphotrapezial, transverse carpal, and trapezio-capitate ligaments. The remaining 2 ligaments attach onto the thumb metacarpal and are the proper intermetacarpal and the dorsal intermetacarpal. The dorsoradial and deep anterior oblique ligaments play a substantial role in stabilizing the trapeziometacarpal joint, and the deep anterior oblique ligament may function as a pivot for the first metacarpal during palmar abduction to allow rotation (pronation). The dorsal trapezio-second metacarpal, volar trapezio-second metacarpal, and trapezio-third metacarpal ligaments function as tension bands and are required to prevent instability from cantilever bending forces on the trapezium.


Assuntos
Articulações dos Dedos/anatomia & histologia , Mãos/anatomia & histologia , Ligamentos Articulares/anatomia & histologia , Polegar/anatomia & histologia , Idoso , Cadáver , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...