1.
J Vasc Interv Radiol ; 33(10): 1143-1150, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35659573

RESUMO

PURPOSE: To report the 5-year results from the Pivotal Multicenter Trial of Ultrasound-Guided Percutaneous Arteriovenous Fistula (pAVF) Creation for Hemodialysis Access. MATERIALS AND METHODS: The retrospective review of 107 intent-to-treat (ITT) patients from the pivotal trial provided a long-term follow-up population (LTP) of 85 patients with a median follow-up duration of 50 months (range, 12-60 months). Data evaluated in the LTP group were fistula maturation and usage, secondary procedures, and complications. The Kaplan-Meier analysis of primary patency, assisted primary patency, cumulative patency, and functional patency (time from 2-needle cannulation to abandonment) were performed for the ITT population. RESULTS: In the LTP, 99% (84 of 85) of fistulae were mature, with 99% (78 of 79) of patients requiring hemodialysis using their pAVF. Sustained fistula use (2-needle cannulation at the prescribed rate, 2 of 3 sessions) was achieved in 92% (78 of 85) of patients, with 7 patients not using their pAVF because they were not on dialysis (n = 4), were on peritoneal dialysis (n = 2), and refused to use fistula (n = 1). Fistula maintenance was required in 31.8% (27 of 85) of patients and included fistula dysfunction (21.2%), thrombosis (5.9%), cannulation injury (12.9%), and arm swelling (4.7%). The number of procedures performed per patient per year to maintain function and patency was 0.32 (91 of 288) for years 2-5. The cumulative patency rates were 89.5%, 88.4%, 88.4%, 85.6%, and 82.0% for years 1, 2, 3, 4, and 5, respectively. The functional patency was 91.8% at the end of the study. There were no major complications related to pAVF during the long-term follow-up. CONCLUSIONS: Percutaneous fistulae have provided clinically effective and durable access for hemodialysis with low complications. The continued use and evaluation of pAVF are warranted.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/métodos , Humanos , Diálise Renal , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular
2.
J Vasc Access ; 21(6): 810-817, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31782685

RESUMO

End-stage kidney disease patients who are candidates for surgical arteriovenous fistula creation commonly experience obstacles to a functional surgical arteriovenous fistula, including protracted wait time for creation, poor maturation, and surgical arteriovenous fistula dysfunction that can result in significant patient morbidity. The recent approval of two endovascular devices designed to create a percutaneous arteriovenous fistula enables arteriovenous fistula creation to be placed in the hands of interventionalists, thereby increasing the number of arteriovenous fistula providers, reducing wait times, and allowing the patient to avoid surgery. Moreover, current studies demonstrate that patients with percutaneous arteriovenous fistula experience improved time to arteriovenous fistula maturation. Yet, in order to realize the potential advantages of percutaneous arteriovenous fistula creation within our hemodialysis patient population, it is critical to select appropriate patients, ensure adequate patient and dialysis unit education, and provide sufficient instruction in percutaneous arteriovenous fistula cannulation and monitoring. In this White Paper by the American Society of Diagnostic and Interventional Nephrology, experts in interventional nephrology, surgery, and interventional radiology convened and provide recommendations on the aforementioned elements that are fundamental to a functional percutaneous arteriovenous fistula.


Assuntos
Derivação Arteriovenosa Cirúrgica , Cateterismo , Tomada de Decisão Clínica , Procedimentos Endovasculares , Falência Renal Crônica/terapia , Diálise Renal , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/educação , Cateterismo/efeitos adversos , Competência Clínica , Consenso , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/educação , Conhecimentos, Atitudes e Prática em Saúde , Pessoal de Saúde/educação , Humanos , Falência Renal Crônica/diagnóstico , Equipe de Assistência ao Paciente , Educação de Pacientes como Assunto , Seleção de Pacientes , Fatores de Risco , Resultado do Tratamento
3.
J Vasc Interv Radiol ; 29(2): 149-158.e5, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29275056

RESUMO

PURPOSE: To evaluate safety and efficacy of arteriovenous fistulas (AVFs) created with a thermal resistance anastomosis device. MATERIALS AND METHODS: A prospective single-arm trial at 5 sites enrolled 107 patients. Patients underwent ultrasound (US)-guided anastomosis creation between the proximal radial artery and perforating vein with the Ellipsys Vascular Access System (Avenu Medical, Inc, San Juan Capistrano, California) followed by separate maturation procedures. Primary endpoints were brachial artery flow volume ≥ 500 mL/min and target vein diameter ≥ 4 mm in > 49% of patients and absence of device-related complications at 90 days. RESULTS: AVFs with fused anastomoses were created in 95% (102/107) of patients. Maturation procedures included anastomotic balloon dilation in 72% (77/107), brachial vein embolization in 32% (34/107), cubital vein ligation in 31% (33/107), and surgical transposition in 26% (28/107) of patients. Primary flow and diameter endpoints were achieved in 86.0% (92/107) of patients, exceeding performance goal of 49% (P < .0001). No major adverse events were attributed to the device. Cumulative patency was 91.6%, 89.3%, and 86.7% at 90 days, 180 days, and 360 days. Target dialysis veins were cephalic, basilic, and brachial veins in 74% (73/99), 24% (24/99), and 2% (2/99) of patients. Two-needle dialysis was achieved in 88% (71/81) of patients on hemodialysis at a mean 114.3 days ± 66.2. Functional patency was 98.4%, 98.4%, and 92.3% at 90 days, 180 days, and 360 days. CONCLUSIONS: The Ellipsys® Vascular Access System met primary safety and efficacy endpoint goals in the US pivotal trial.


Assuntos
Derivação Arteriovenosa Cirúrgica , Diálise Renal , Ultrassonografia de Intervenção , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Artéria Braquial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/administração & dosagem , Estudos Prospectivos , Artéria Radial
4.
J Vasc Interv Radiol ; 27(8): 1105-1114.e3, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27388566

RESUMO

PURPOSE: To present final, 2-year data from randomized comparison of an expanded polytetrafluoroethylene stent graft (SG) and percutaneous transluminal angioplasty (PTA) for treatment of arteriovenous graft (AVG) anastomotic stenoses. MATERIALS AND METHODS: A 28-site, prospective, controlled US study enrolled 270 patients with malfunctioning AVG anastomotic stenoses of ≥ 50%; 138 patients underwent SG placement, and 132 underwent PTA alone. Follow-up imaging and intervention were event-driven. RESULTS: The study was completed by 191 patients (97 SG, 94 PTA). Five patients were lost to follow-up or withdrew; 74 patients died during the study (38 SG, 36 PTA). At 12 months, treatment area primary patency (TAPP) was SG 47.6% versus PTA 24.8% (P < .001), access circuit primary patency (ACPP) was SG 24% versus PTA 11% (P = .007), and index of patency function (IPF) was SG 5.2 months/intervention ± 4.1 versus PTA 4.4 months/intervention ± 3.5 (P = .009). At 24 months, TAPP was SG 26.9% versus PTA 13.5% (P < .001), ACPP was SG 9.5% versus PTA 5.5% (P = .01), and IPF was SG 7.1 months/intervention ± 7.0 versus PTA 5.3 months/intervention ± 5.2; estimated number of reinterventions before graft abandonment was 3.4 for SG patients versus 4.3 for PTA patients. There were no significant differences in adverse events (P > .05) except for restenosis requiring reintervention rates of 82.6% in PTA patients versus 63.0% in SG patients (P < .001). CONCLUSIONS: At 2 years, SG use provided a sustained, greater than 2-fold advantage over PTA in treatment area and overall access patency. Time to subsequent intervention was longer in the SG group.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Diálise Renal , Idoso , Angioplastia com Balão/efeitos adversos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Retratamento , Stents , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS