1.
J Mech Behav Biomed Mater ; 61: 55-61, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26849027

RESUMO

The aim of this study was to evaluate the variation of hardness with fatigue in calf pericardium, a biomaterial commonly used in bioprosthetic heart valves, and its relationship with the energy dissipated during the first fatigue cycle that has been shown to be a predictor of fatigue-life (García Páez et al., 2006, 2007; Rojo et al., 2010). Fatigue tests were performed in vitro on 24 pericardium specimens cut in a root-to-apex direction. The specimens were subjected to a maximum stress of 1MPa in blocks of 10, 25, 50, 100, 250, 500, 1000 and 1500 cycles. By means of a modified Shore A hardness test procedure, the hardness of the specimen was measured before and after fatigue tests. Results showed a significant correlation of such hardness with fatigue performance and with the energy dissipated in the first cycle of fatigue, a predictor of pericardium durability. The study showed indentation hardness as a simple and reliable indicator of mechanical performance, one which could be easily implemented in improving tissue selection.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Animais , Bovinos , Análise de Falha de Equipamento , Dureza , Valvas Cardíacas , Pericárdio
2.
Artif Organs ; 34(3): E65-71, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20447036

RESUMO

The tearing of the collagen fibers of biological materials utilized in implants or bioprostheses is an important, and sometimes early cause of the failure of these devices. We studied the force necessary to propagate a tear in a biomaterial, pericardium from young bulls, and the influence of the suture. An Elmendorf pendulum capable of measuring the force necessary to tear a given length of tissue was employed. We analyzed 112 trials (70%) that proved valid after achieving the homogeneity of the samples according to their thickness, thus making the results comparable. Mean forces ranging between 19.87 and 150 N were required to propagate tears measuring from 0.25 to 2.0 cm. In the samples with a 1-cm-long suture, sewn using an edge-to-edge technique, the propagation of the tear required a mean force of 15.75 N when the suture was made of nylon and 28.73 N when Prolene was utilized. When these results were compared with the mean recorded in an unsutured control series (56.76 N), the loss of resistance was significant in both sutured series (P = 0.000 and P = 0.011, respectively). Finally, the equation that relates the force (y) with the length of the tear made in unsutured tissue (x) was also obtained: y = 58.14 + 9.62x(2) (R(2) = 0.924). The force necessary to produce a microtear, thus estimated, can be utilized as a parameter for comparison.


Assuntos
Bioprótese , Procedimentos Cirúrgicos Cardíacos/instrumentação , Pericárdio/transplante , Falha de Prótese , Implantação de Prótese/instrumentação , Técnicas de Sutura/instrumentação , Suturas , Fatores Etários , Animais , Bovinos , Análise de Falha de Equipamento , Masculino , Teste de Materiais , Modelos Biológicos , Nylons , Polipropilenos , Desenho de Prótese , Ruptura , Estresse Mecânico
3.
J Biomed Mater Res B Appl Biomater ; 79(2): 229-35, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16637030

RESUMO

The durability of prosthetic heart valve leaflets made of biological materials is limited. A tear in the biomaterial accelerates their early failure, but microtearing of the collagen fibers may be responsible for their medium-term failure. We studied the force necessary to propagate tearing in two biomaterials: ostrich and calf pericardium. One hundred twenty samples of each tissue were tested in an Elmendorf pendulum capable of measuring the force required to tear a tissue in which a predefined slit had been made. The forces required to produce tears, ranging between 2.5 and 0.25 cm in length, were determined. For ostrich pericardium, this force ranged between 67.67 and 4.80 newton, while that required to tear the same lengths of calf pericardium ranged between 70.67 and 4.70 newton. The function that relates the tearing force to the length of the tear was expressed as follows: y = 20.62x + 1.77x(2) (R(2) = 0.923) for ostrich pericardium and y = 45.57x - 7.21x(2) (R(2) = 0.936) for calf pericardium, where y is the force in newton and x is the length in centimeter. Calf pericardium was found to have a greater resistance to tearing. However, these results should be interpreted with caution owing to the fact that the thickness of the majority of the samples of ostrich pericardium was significantly less than that of calf pericardium. A more careful selection and utilization of adult ostrich pericardium would probably improve these results.


Assuntos
Materiais Biocompatíveis , Pericárdio/lesões , Animais , Bioprótese , Bovinos , Próteses Valvulares Cardíacas , Struthioniformes , Resistência à Tração
4.
J Biomed Mater Res B Appl Biomater ; 72(1): 9-16, 2005 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-15490469

RESUMO

We studied the mechanical behavior in response to tensile stress of samples of ostrich pericardium bonded with a cyanoacrylate glue or sewn with a rectangular, overlapping suture that was subsequently sealed with the same bioadhesive. Seventy-two trials were performed in three series of 24 samples each: series AG, glued with an overlap of 1 cm2; series ASG, sewn with a rectangular, overlapping suture and sealed; and series AC, control samples that were left intact. The mean stress at rupture in series AG (glued) was 0.1 MPa, much lower than the working stress of a human valve leaflet, which is approximately 0.25 MPa. In the control series, this stress was 26.28 MPa. At rupture in series ASG (sutured/glued), the suture material was being subjected to a stress of 64.91 MPa, thus confirming the existence of an interaction between the suture and the shear stress exerted by the suture on the samples of pericardium. In series ASG, the mean value for the resistance to rupture when measured in machine kg was 8.83 kg, lower than but similar to that recorded in the control series AC (10.26 kg). The percentages of reversible deformation, or elongation, once the samples were torn were similar in series AC (19.15%) and ASG (21.93%). This phenomenon can only be explained by the damage to the collagen fibers in the area around the rupture, while other more distant regions work at a lower load within the elastic limit. We conclude that cyanocrylate adhesives alone are not suitable as bonding materials in cardiac bioprostheses. The results with the rectangular, overlapping suture, when subsequently sealed with an adhesive, can be considered good because, although this approach does not impede shear stress, it does maintain an excellent degree of resistance to rupture of the samples thus joined. We stress the need to take into account the concentration of the load in the design of bioprostheses.


Assuntos
Adesivos , Materiais Biocompatíveis/química , Pericárdio/química , Struthioniformes , Técnicas de Sutura , Animais , Matemática , Estresse Mecânico , Suturas
5.
J Biomed Mater Res B Appl Biomater ; 69(2): 125-34, 2004 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-15116401

RESUMO

The tearing of the valve leaflet of a cardiac bioprosthesis can cause early failure of this device, which is employed to replace a diseased native valve. This report involves the study of the behavior of 312 tissue samples (152 of calf pericardium and 160 of ostrich pericardium) treated with glutaraldehyde and subsequently subjected to tear testing. The samples were cut in the two principal directions: longitudinally, or root to apex, and transversely. They included a series of control samples that were left unsutured, and the remaining samples were repaired with the use of two different suture techniques: a running suture in the direction of the load and a telescoping suture perpendicular to the load. Four commercially available suture materials were employed: Pronova, nylon, Gore-Tex, or silk. The unsutured control samples of both types of pericardium exhibited a similar anisotropic behavior in the tear test. The mean resistance to tearing of the calf pericardium was 24.29 kN m in samples cut longitudinally and 34.78 kN m in those cut transversely (p =.03); the values were 28.08 kN m and 37.12 kN m (p =.002), respectively, in ostrich pericardium. The series repaired with the telescoping suture always exhibited greater resistance to tearing, with values that ranged between 44.34 and 64.27 kN for the samples of calf pericardium and from 41.65 to 47.65 kN for those obtained from ostrich. These assays confirm the anisotropic behavior of calf and ostrich pericardium treated with glutaraldehyde when subjected to tear testing, as well as the loss of this behavior in ostrich pericardium after suturing. Suturing techniques, such as the telescoping model, that provide a greater resistance to tearing should be studied for use in the design of the valve leaflets of cardiac bioprostheses made of biological materials.


Assuntos
Bovinos , Próteses Valvulares Cardíacas , Pericárdio , Struthioniformes , Técnicas de Sutura , Suturas , Animais , Anisotropia , Materiais Biocompatíveis , Bovinos/anatomia & histologia , Teste de Materiais , Pericárdio/anatomia & histologia , Pericárdio/patologia , Pericárdio/cirurgia , Falha de Prótese , Estresse Mecânico , Struthioniformes/anatomia & histologia , Resistência à Tração