1.
Acad Radiol ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38702213

RESUMO

PURPOSE: The purpose of this study was to evaluate the technical and clinical success of middle meningeal artery (MMA) embolization performed for symptomatic subacute subdural hematoma (SDH) in patients with cancer. METHODS: This study retrospectively included 23 consecutive patients (12 men, 11 women; median age 61 years, interquartile range: 55.5-75.5) who underwent 34 MMA angiograms for symptomatic SDH in 2022 and 2023. Median SDH thickness was 10.5 mm (7-12). Median platelet count was 117 K/mcL (54.5-218). 10 patients (43.5%, 10/23) had hematologic malignancies, seven patients (30.4%, 7/23) had surgery. Fluoroscopy time (FT), reference dose (RD), and kerma area product (Kap) were analyzed. Adverse events and outcomes were recorded. RESULTS: The median imaging and clinical follow-up were 65 days (36.5-190.5) and 163 days (86-274), respectively. The technical success rate was 91.2% (31/34) as three MMA were not identified in two patients. Median procedure duration was 61 min (55.5-75.5). Median FT was 21.6 min (15.5-31.8); median RD was 158 mGy (96-256); and median Kap was 32.9 Gy.cm2 (20.4-45.1). No further intervention was needed. For 16 patients, SDH resolved after in median 59.5 days (50-90). For seven patients, SDH remained visible on the last imaging follow-up performed at 24 days in median (6.5-36.5). No predictive factor of failure was identified. The adverse event rate was 1/23 (4.3%). Eight patients (34.8%, 8/23) died during follow-up from progression of cancer. CONCLUSION: MMA embolization of symptomatic SDH in patients with cancer appears safe and is associated with improvement in clinical symptoms.

3.
Br J Radiol ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38588564

RESUMO

OBJECTIVES: To assess the safety and efficacy of percutaneous cryoablation (CA) of soft-tissue tumors (desmoid tumors (DT), vascular malformations (VM), and abdominal wall endometriosis (AWE)). METHODS: This systematic review of studies published before January 2024 encompassed a detailed analysis of CA techniques and technical aspects for the treatment of soft-tissue tumors. Data concerning CA efficacy, complication rates, and other relevant metrics was extracted and included for analysis. RESULTS: The analysis included 27 studies totaling 554 CA procedures. For DT (13 studies, 393 sessions), CA showed an average pain reduction of 79 ± 17% (range: 57-100) and a lesion volume decrease of 71.5 ± 9.8% (range: 44-97). VM (4 studies, 58 sessions) had a 100% technical success rate and an average pain reduction of 72 ± 25% (range: 63-85). The average pain reduction for AWE (6 studies, 103 sessions) was 82 ± 13% (range: 62-100). Overall, the complication rate for CA was low, with minor adverse events (AE) in about 20% of patients and major events in less than 5% of patients. CONCLUSION: Showing substantial efficacy in pain reduction and lesion volume decrease, as well as low incidence of severe AE, CA presents as a highly effective and safe alternative for the treatment of soft-tissue tumors. ADVANCES IN KNOWLEDGE: CA is effective and safe in treating soft-tissue tumors, particularly DT, VM, and AWE.

4.
Can Assoc Radiol J ; : 8465371241242758, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581355

RESUMO

Objectives: This systematic review aims to assess existing research concerning the use of robotic systems to execute percutaneous lung biopsy. Methods: A systematic review was performed and identified 4 studies involving robotic systems used for lung biopsy. Outcomes assessed were operation time, radiation dose to patients and operators, technical success rate, diagnostic yield, and complication rate. Results: One hundred and thirteen robot-guided percutaneous lung biopsies were included. Technical success and diagnostic yield were close to 100%, comparable to manual procedures. Technical accuracy, illustrated by needle positioning, showed less frequent needle adjustments in robotic guidance than in manual guidance (P < .001): 2.7 ± 2.6 (range 1-4) versus 6 ± 4 (range 2-12). Procedure time ranged from comparable to reduced by 35% on average (20.1 ± 11.3 minutes vs 31.4 ± 10.2 minutes, P = .001) compared to manual procedures. Patient irradiation ranged from comparable to reduced by an average of 40% (324 ± 114.5 mGy vs 541.2 ± 446.8 mGy, P = .001). There was no significant difference in reported complications between manual biopsy and biopsies that utilized robotic guidance. Conclusion: Robotic systems demonstrate promising results for percutaneous lung biopsy. These devices provide adequate accuracy in probe placement and could both reduce procedural duration and mitigate radiation exposure to patients and practitioners. However, this review underscores the need for larger, controlled trials to validate and extend these findings.

5.
Can Assoc Radiol J ; : 8465371241236152, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38444144

RESUMO

Interventional Oncology (IO) stands at the forefront of transformative cancer care, leveraging advanced imaging technologies and innovative interventions. This narrative review explores recent developments within IO, highlighting its potential impact facilitated by artificial intelligence (AI), personalized medicine and imaging innovations. The integration of AI in IO holds promise for accelerating tumour detection and characterization, guiding treatment strategies and refining predictive models. Imaging modalities, including functional MRI, PET and cone beam CT are reshaping imaging and precision. Navigation, fusion imaging, augmented reality and robotics have the potential to revolutionize procedural guidance and offer unparalleled accuracy. New developments are observed in embolization and ablative therapies. The pivotal role of genomics in treatment planning, targeted therapies and biomarkers for treatment response prediction underscore the personalization of IO. Quality of life assessment, minimizing side effects and long-term survivorship care emphasize patient-centred outcomes after IO treatment. The evolving landscape of IO training programs, simulation technologies and workforce competence ensures the field's adaptability. Despite barriers to adoption, synergy between interventional radiologists' proficiency and technological advancements hold promise in cancer care.

6.
Eur Radiol ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512491

RESUMO

OBJECTIVE: To retrospectively evaluate the long-term outcomes after percutaneous cryoablation of abdominal wall endometriosis (AWE). METHOD: The Institutional Review Board approved this retrospective observational review of 40 consecutive patients, of a median age of 37 years (interquartile range [IQR] 32-40 years), presenting with a total of 52 symptomatic AWE nodules. All patients underwent cryoablation between January 2013 and May 2022 with a minimum follow-up period of 12 months. Outcomes were assessed using a visual analog scale (VAS) that measured pain, as well as by magnetic resonance imaging (MRI). The pain-free survival rates were derived using the Kaplan-Meier estimator. Adverse events were analyzed and graded using the classification system of the Cardiovascular and Interventional Radiological Society of Europe. RESULTS: The median follow-up time was 40.5 months (IQR 26.5-47.2 months). The median VAS score before cryoablation was 8 (IQR 7-9). Complete relief of symptoms was documented in 80% (32/40) of patients at 3 months after initial cryoablation and correlated with the absence of residual endometriosis nodules on MRI. The median pain-free survival rates were 89.2% [95% CI, 70.1-96.4%] at 36 months and 76.8% [95% CI, 55.3-83.8%] after 60 months. No patient or lesion characteristics were found to be prognostic of failure. No major adverse events or side effects were reported in long term. CONCLUSION: Cryoablation safely and effectively afforded long-term pain relief for patients with AWE nodules. CLINICAL RELEVANCE STATEMENT: AWE cryoablation was found to be safe and effective in the long-term. KEY POINTS: • Cryoablation is highly effective with 80% of patients experiencing complete relief of AWE symptoms after a single procedure. • Cryoablation is safe without long-term adverse events or side effects. • The median pain-free survival rates are 89.2% at 36 months and 76.8% at 60 months.

7.
J Vasc Interv Radiol ; 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38447771

RESUMO

PURPOSE: To compare the effectiveness of percutaneous lung biopsy using a patient-mounted needle-driving robotic system with that using a manual insertion of needles under computed tomography (CT) fluoroscopy guidance. MATERIALS AND METHODS: In this institutional review board approved study, the cohort consisted of a series of patients who underwent lung biopsies following the intention-to-treat protocol from September 2022 to September 2023 using robot (n = 15) or manual insertion under single-rotation CT fluoroscopy (n = 66). Patient and procedure characteristics were recorded as well as outcomes. RESULTS: Although age, body mass index, and skin-to-target distance were not statistically different, target size varied (median, 8 mm [interquartile range, 6.5-9.5 mm] for robot vs 12 mm [8-18 mm] for single-rotation CT fluoroscopy; P = .001). No statistical differences were observed in technical success (86.7% [13/15] vs 89.4% [59/66], P = .673), Grade 3 adverse event (AE) (6.7% [1/15] vs 12.1% [8/66], P = .298), procedural time (28 minutes [22-32 minutes] vs 19 minutes [14.3-30.5 minutes], P = .086), and patient radiation dose (3.9 mSv [3.2-5.6 mSv] vs 4.6 mSv [3.3-7.5 mSv], P = .398). In robot-assisted cases, the median angle out of gantry plane was 10° (6.5°-16°), although it was null (0°-5°) for single-rotation CT fluoroscopy (P = .001). CONCLUSIONS: Robot-assisted and single-rotation CT fluoroscopy-guided percutaneous lung biopsies were similar in terms of technical success, diagnostic yield, procedural time, AEs, and radiation dose, although robot allowed for out-of-gantry plane navigation along the needle axis.

10.
Int J Hyperthermia ; 41(1): 2313492, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38369302

RESUMO

BACKGROUND: Despite the theoretical advantages of treating metastatic bone disease with microwave ablation (MWA), there are few reports characterizing microwave absorption and bioheat transfer in bone. This report describes a computational modeling-based approach to simulate directional microwave ablation (dMWA) in spine, supported by ex vivo and pilot in vivo experiments in porcine vertebral bodies. MATERIALS AND METHODS: A 3D computational model of microwave ablation within porcine vertebral bodies was developed. Ex vivo porcine vertebra experiments using a dMWA applicator measured temperatures approximately 10.1 mm radially from the applicator in the direction of MW radiation (T1) and approximately 2.4 mm in the contra-lateral direction (T2). Histologic assessment of ablated ex vivo tissue was conducted and experimental results compared to simulations. Pilot in vivo experiments in porcine vertebral bodies assessed ablation zones histologically and with CT and MRI. RESULTS: Experimental T1 and T2 temperatures were within 3-7% and 11-33% of simulated temperature values. Visible ablation zones, as indicated by grayed tissue, were smaller than those typical in other soft tissues. Posthumous MRI images of in vivo ablations showed hyperintensity. In vivo experiments illustrated the technical feasibility of creating directional microwave ablation zones in porcine vertebral body. CONCLUSION: Computational models and experimental studies illustrate the feasibility of controlled dMWA in bone tissue.


Assuntos
Técnicas de Ablação , Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Técnicas de Ablação/métodos , Micro-Ondas/uso terapêutico , Simulação por Computador , Coluna Vertebral/cirurgia , Fígado/cirurgia , Ablação por Cateter/métodos
11.
Med Eng Phys ; 124: 104100, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38418016

RESUMO

The optimal positioning of an implant into a living organ such as femurs and vertebra is still an open problem. In particular, vertebral implant position has a significant impact on the results on spine behaviour after treatment in terms of stiffness, range of motion (ROM), wear, loosening and failure. In the current work, a 3D finite element analysis was conducted to investigate the positioning parameters of a novel transpedicular implant (V-STRUT©, Hyprevention, France) in terms of placement of the implant in the treated vertebra. The implant was designed in order to strength osteoporotic vertebral body and the related spine segment under compressive load. The effects of the axial and sagittal positions of the implant in the treated vertebra was investigated in terms of stress and stiffness variations. A 3D finite element model of an osteoporotic spine segment was built based on a Computed Tomography (CT) scan of an osteoporotic female (69 yo). The model is composed of T12, L1 and L2 vertebrae and corresponding intervertebral discs and ligaments. The bone tissue was modeled as a heterogeneous material with properties assigned based on the grey scale levels. The intervertebral discs were modeled using two regions describing the annulus and the nucleus and linear beam elements with specific stiffness each were used representing each ligament. The simulations indicated that the sagittal position (distance d) plays a role on the stress distribution. The closer the implant to the interior wall the lower the stress applied to the spine segment. Nevertheless, the axial plane position (distance h) have limited effects on the stress applied to the bone with a higher stress applied to the device (subjected to a higher bending load). These results can have direct clinical implications when dealing with the optimal placement of the implant. It is also possible to select a particular position in order to assign a given (target) stiffness for a patient.


Assuntos
Disco Intervertebral , Fraturas da Coluna Vertebral , Feminino , Humanos , Análise de Elementos Finitos , Fenômenos Biomecânicos , Vértebras Lombares
12.
Front Oncol ; 14: 1324095, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38406802

RESUMO

Background & aims: The treatment options for systemically progressed hepatocellular carcinoma (HCC) have significantly expanded in recent years. In this study, we aimed to evaluate the potential of Google searches as a reflection of prescription rates for HCC drugs in the United States (US). Methods: We conducted an in-depth analysis of US prescription data obtained from the IQVIA National Prescription Audit (NPA) and corresponding Google Trends data from January 2017 to December 2022. We focused on drugs used in the first line and second or later treatment lines for HCC, collecting data on their prescriptions and search rates. Search volumes were collected as aggregated search queries for both generic drugs and their respective brand names. Results: During the study period from Q1 2017 to Q4 2022, monthly prescriptions for drugs used in HCC treatment showed an 173% increase (from 1253 to 3422). Conversely online searches increased by 3.5% (from 173 to 179 per 10 million searches). Notably, strong correlations were observed between search interest and prescriptions for newer drugs, which indicates increasing usage, while older drugs with declining usage displayed limited correlation. Our findings suggest a growing role of non-physician professions in managing systemically progressed HCC within the US healthcare system, although oncologists remained primarily responsible for drug prescriptions. Conclusions: In conclusion, online search monitoring can offer the potential to reflect prescription trends specifically related to the treatment of HCC. This approach provides a swift and accessible means of evaluating the evolving landscape of HCC treatment.

13.
Can Assoc Radiol J ; : 8465371241228256, 2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38311875

RESUMO

OBJECTIVES: To prospectively evaluate the feasibility and safety of a polyetheretherketone (PEEK) polymer transpedicular vertebral system to treat vertebral compression fracture (VCF). METHODS: Nine consecutive patients (4 men and 5 women; median age 59 [interquartile range: 58-64 years]) were included. The procedure duration, length of hospital stay, and complications were reported. Visual analog scale (VAS) and the Oswestry disability index (ODI) for pain and disability were assessed before and at 2, 6, and 12-month after the procedure. RESULTS: The procedure was technically feasible in all patients. The median procedural time was 64 minutes [45-94]. Only minor adverse events were reported (5 clinically asymptomatic cement leakages) but no severe complications. No post procedural adjacent fracture was reported during follow-up (median: 193 days [147-279]). The median VAS score decreased from 55 mm [50-70] before the procedure to 25 mm [5-30] at 2-month (P = .0003) and 30 mm [15-40] at 6-month follow-up (P = .14). The median ODI decreased from 23% [19-26] before the procedure to 12% [10-14] at 2-month (P = .03) and 12% [9-20] at 6-month follow-up (P = .47). CONCLUSIONS: Percutaneous transpedicular fixation of VCF by PEEK implants appears feasible and safe.

14.
Diagn Interv Imaging ; 105(3): 87-96, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38065817

RESUMO

Interventional radiology shows promises in the field of women's health, particularly in pelvic interventions. This review article discusses the latest advancements in interventional radiology techniques for pelvic conditions affecting women including adenomyosis, abdominal wall endometriosis and uterine leiomyoma. Extraperitoneal endometriosis involving the abdominal wall may be treated by percutaneous thermal ablation, such as cryoablation, whereas uterine leiomyoma and adenomyosis can be managed either using percutaneous thermal ablation or using uterine artery embolization. Continued research and development in interventional radiology will further enhance the minimally-invasive interventions available for women's health, improving outcomes and quality of life for this large patient population of women.


Assuntos
Parede Abdominal , Adenomiose , Endometriose , Leiomioma , Embolização da Artéria Uterina , Neoplasias Uterinas , Feminino , Humanos , Endometriose/terapia , Endometriose/cirurgia , Adenomiose/terapia , Adenomiose/cirurgia , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/terapia , Radiologia Intervencionista , Qualidade de Vida , Parede Abdominal/diagnóstico por imagem , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Embolização da Artéria Uterina/métodos
16.
Cardiovasc Intervent Radiol ; 47(1): 80-86, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37910259

RESUMO

PURPOSE: To evaluate factors affecting the diagnostic yield (percent of biopsy samples leading to a pathologic diagnosis) of lesional bone biopsies in patients with hematologic malignancies. MATERIALS AND METHODS: This retrospective study included 206 lesional bone biopsies in 182 patients with a hematologic malignancy between January 2017 and December 2022. The parameters that were reviewed to evaluate diagnostic yield included biopsy device type (manual vs. electric-powered drill), number of biopsy cores acquired, core biopsy needle gauge, preliminary intra-procedural sample adequacy (touch preparation cytology determining if samples are adequate for final pathologic examination), lesion morphology on Computed Tomography (CT), and presence of crush artifact. RESULTS: Review of 206 lesional biopsies showed overall diagnostic yield to be 89.8% (185/206). The two statistically significant factors affecting diagnostic yield were biopsy device type and in-room adequacy. 41/42 samples obtained with the electric-powered drill and 144/164 samples obtained using a variety of manual needles were diagnostic (97.6% vs 87.8%, p = 0.03). Of the 192 samples that were assessed for sample adequacy intra-procedurally, 97/102 of the samples that were deemed adequate were diagnostic, and 77/90 of the samples where intra-procedural adequacy was not confirmed were diagnostic (95.1% vs 85.6%, p = 0.018). The remaining factors did not affect diagnostic yield. CONCLUSION: The use of an electric-powered drill bone biopsy device and intra-procedural confirmation of sample adequacy are associated with a higher diagnostic yield of lesional bone biopsies in patients with hematologic malignancies. The presence or absence of crush artifact did not significantly affect the diagnostic yield in these patients.


Assuntos
Doenças Ósseas , Neoplasias Hematológicas , Humanos , Estudos Retrospectivos , Osso e Ossos/patologia , Biópsia por Agulha Fina , Biópsia Guiada por Imagem/métodos
17.
J Vasc Interv Radiol ; 35(3): 409-415, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38008376

RESUMO

PURPOSE: To evaluate the impact of virtual injection software (VIS) use during cone-beam computed tomography (CT)-guided prostatic artery embolization (PAE) on both patient radiation exposure and procedural time. MATERIALS AND METHODS: This institutional review board (IRB)-approved comparative retrospective study analyzed the treatment at a single institution of 131 consecutive patients from January 2020 to May 2022. Cone-beam CT was used with (Group 1, 77/131; 58.8%) or without VIS (Group 2, 54/131, 41.2%). Radiation exposure (number of digital subtraction angiography [DSA] procedures), dose area product (DAP), total air kerma (AK), peak skin dose (PSD), fluoroscopy time (FT), and procedure time (PT) were recorded. The influences of age, body mass index, radial access, and use of VIS were assessed. RESULTS: In bivariate analysis, VIS use (Group 1) showed reduction in the number of DSA procedures (8.6 ± 3.7 vs 16.8 ± 4.3; P < .001), DAP (110.4 Gy·cm2 ± 46.8 vs 140.5 Gy·cm2 ± 61; P < .01), AK (642 mGy ± 451 vs 1,150 mGy ± 637; P = .01), PSD (358 mGy ± 251 vs 860 mGy ± 510; P = .001), FT (35.6 minutes ± 15.4 vs 46.6 minutes ± 20; P = .001), and PT (94.6 minutes ± 41.3 vs 115.2 minutes ± 39.6, P = .005) compared to those in Group 2. In multivariate analysis, AK, PSD, FT, and PT reductions were associated with VIS use (P < .001, P < .001, P = .001, and P = .006, respectively). CONCLUSIONS: The use of VIS during PAE performed under cone-beam CT guidance led to significant reduction in patient radiation exposure and procedural time.


Assuntos
Embolização Terapêutica , Hiperplasia Prostática , Exposição à Radiação , Masculino , Humanos , Embolização Terapêutica/efeitos adversos , Próstata/diagnóstico por imagem , Próstata/irrigação sanguínea , Estudos Retrospectivos , Hiperplasia Prostática/terapia , Artérias/diagnóstico por imagem , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Software , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/métodos , Doses de Radiação , Fluoroscopia
19.
Tech Vasc Interv Radiol ; 26(3): 100912, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38071025

RESUMO

Cone-beam computed tomography (CBCT) has emerged as a prominent imaging modality in interventional radiology that offers real-time visualization and precise guidance in various procedures. This article aims to provide an overview of the techniques used to guide and monitor interventions that use CBCT. It discusses the advantages of CBCT, its current applications, and potential future CBCT-related developments in the field of interventional radiology.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiologia Intervencionista , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Radiologia Intervencionista/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...