Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Fetal Diagn Ther ; 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39159614

RESUMO

Introduction Speckle tracking echocardiography (STE) is a non-Doppler modality allowing the semiautomated evaluation of the fetal cardiac function by tracking the speckles of the endocardial borders. Little evidence is available on the evaluation and comparison of different software for the functional assessment of the fetal heart by means of STE. The aim of this study is to evaluate the reproducibility and agreement of two different proprietary speckle tracking software for the prenatal semi-automated assessment of the fetal cardiac function. Methods Prospective study including non-anomalous fetuses referred for different indications at two tertiary academic units in Italy (University of Parma) and Spain (University of Barcelona). 2D clips of the four-chamber view of the fetal heart were acquired by two operators using high-end ultrasound machines with a frame rate higher than 60 Hz. The stored clips were pseudo-anonymized and shared between the collaborating Units. Functional echocardiographic analyses were independently performed using the two proprietary software (TomTec GmbH and FetalHQ®) by the same operators. Inter-software reproducibility of the endocardial global longitudinal strain (EndoGLS) and fractional area change (FAC) of the left (LV) and the right ventricles (RV) and ejection fraction (EF) of the LV were evaluated by the intraclass correlation coefficient (ICC). Results 48 fetuses were included at a median of 31+2 (21+6 - 40+3) gestational weeks. Moderate reproducibility was found for the functional parameters of the LV: EndoGLS (Pearson's correlation 0.456, p<0.01; ICC 0.446, 95%CI (0.189-0.647), p<0.01); EF (Pearson's correlation 0.435, p<0.01; ICC 0.419, 95%CI (0.156-0.627), p<0.01); FAC (Person's correlation 0.484, p<0.01; ICC 0.475, 95%CI (0.223-0.667), p<0.01). On the contrary, RV functional parameters showed poor reproducibility between the two software: EndoGLS (Pearson's correlation 0.383, p=0.01; ICC 0.377, 95%CI (0.107-0.596), p<0.01) and FAC (ICC 0.284, 95%CI (0.003-0.524), p=0.02). Conclusion Our results demonstrate a moderate reproducibility of the speckle tracking analysis of the LV using TomTec GmbH and FetalHQ®, with poor reproducibility for RV analysis.

2.
Am J Obstet Gynecol MFM ; 6(9): 101445, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39074608

RESUMO

BACKGROUND: Beyond 18 weeks of gestation, an increased size of the fetal lateral ventricles is reported in most fetuses with open spina bifida. In the first trimester of pregnancy, the definition of ventriculomegaly is based on the ratio of the size of the choroid plexus to the size of the ventricular space or the entire fetal head. However, contrary to what is observed from the midtrimester of pregnancy, in most fetuses with open spina bifida at 11 to 13 weeks of gestation, the amount of fluid in the ventricular system seems to be reduced rather than increased. OBJECTIVE: This study aimed to compare the biometry of the lateral ventricles at 11 0/7 to 13 6/7 weeks of gestation between normal fetuses and those with confirmed open spina bifida. STUDY DESIGN: This was a retrospective cohort study that included all cases of isolated open spina bifida detected at 11 0/7 to 13 6/7 weeks of gestation over a period of 5 years and a group of structurally normal fetuses attending at our center over a period of 1 year for the aneuploidy screening as controls. Transventricular axial views of the fetal brain obtained from cases and controls were extracted from the archive for post hoc measurement of cerebral ventricles. The choroid plexus-to-lateral ventricle length ratio, sum of the choroid plexus-to-lateral ventricle area ratio, choroid plexus area-to-fetal head area ratio, and mean choroid plexus length-to-occipitofrontal diameter ratio were calculated for both groups. The measurements obtained from the 2 groups were compared, and the association between each parameter and open spina bifida was investigated. RESULTS: A total of 10 fetuses with open spina bifida were compared with 358 controls. Compared with controls, fetuses with open spina bifida showed a significantly smaller size of the cerebral ventricle measurements, as expressed by larger values of choroid plexus-to-lateral ventricle area ratio (0.49 vs 0.72, respectively; P<.001), choroid plexus-to-lateral ventricle length ratio (0.70 vs 0.79, respectively; P<.001), choroid plexus area-to-fetal head area ratio (0.28 vs 0.33, respectively; P=.006), and choroid plexus length-to-occipitofrontal diameter ratio (0.52 vs 0.60, respectively; P<.001). The choroid plexus-to-lateral ventricle area ratio was found to be the most accurate predictor of open spina bifida, with an area under the curve of 0.88, a sensitivity of 90%, and a specificity of 82%. CONCLUSION: At 11 0/7 to 13 6/7 weeks of gestation, open spina bifida is consistently associated with a reduced amount of fluid in the lateral cerebral ventricles of the fetus, as expressed by a significantly increased choroid plexus-to-lateral ventricle length ratio, choroid plexus-to-lateral ventricle area ratio, choroid plexus area-to-fetal head area ratio, and choroid plexus length-to-occipitofrontal diameter ratio.


Assuntos
Plexo Corióideo , Ventrículos Laterais , Primeiro Trimestre da Gravidez , Espinha Bífida Cística , Ultrassonografia Pré-Natal , Humanos , Feminino , Estudos Retrospectivos , Gravidez , Ultrassonografia Pré-Natal/métodos , Espinha Bífida Cística/embriologia , Espinha Bífida Cística/diagnóstico , Espinha Bífida Cística/diagnóstico por imagem , Ventrículos Laterais/embriologia , Ventrículos Laterais/diagnóstico por imagem , Plexo Corióideo/embriologia , Plexo Corióideo/diagnóstico por imagem , Adulto , Idade Gestacional , Estudos de Coortes , Estudos de Casos e Controles
3.
Prenat Diagn ; 42(2): 180-191, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35032031

RESUMO

OBJECTIVE: To assess the safety of Partial-Amniotic-Insufflation-of-heated-humidified-CO2 (hPACI) during fetoscopic spina bifida repair (fSB-repair). METHOD: A simulated fSB-repair through an exteriorized uterus under hPACI was performed in 100-day fetal lambs (term = 145 days) under a laboratory anesthesia protocol (n = 5; group 1) which is known to induce maternal-fetal acidosis and hypercapnia. Since these may not occur clinically, we applied a clinical anesthesia protocol (n = 5; group 2), keeping maternal parameters within physiological conditions, that is, controlled maternal arterial carbon dioxide (CO2) pressure (pCO2  = 30 mmHg), blood pressure (≥67 mmHg), and temperature (37.1-39.8°C). Our superiority study used fetal pH as the primary outcome. RESULTS: Compared to group 1, controlled anesthesia normalized fetal pH (7.23 ± 0.02 vs. 7.36 ± 0.02, p < 0.001), pCO2 (70.0 ± 9.1 vs. 43.0 ± 1.0 mmHg, p = 0.011) and bicarbonate (27.8 ± 1.1 vs. 24.0 ± 0.9 mmol/L, p = 0.071) at baseline. It kept them within clinically acceptable limits (pH ≥ 7.23, pCO2  ≤ 70 mmHg, bicarbonate ≤ 30 mm/L) for ≥120 min of hPACI as opposed to ≤30 min in group one. Fetal pO2 and lactate were comparable between groups and generally within normal range. Fetal brain histology demonstrated fewer apoptotic cells and higher neuronal density in the prefrontal cortex in group two. There was no difference in fetal membrane inflammation, which was mild. CONCLUSION: Fetoscopic insufflation of heated-humidified CO2 during simulated fSB-repair through an exteriorized uterus can be done safely under controlled anesthesia.


Assuntos
Anestesia/métodos , Dióxido de Carbono/administração & dosagem , Fetoscopia/métodos , Insuflação/métodos , Disrafismo Espinal/cirurgia , Animais , Feminino , Temperatura Alta , Umidade , Gravidez , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA