Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int Endod J ; 51(5): 522-528, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28329416

RESUMO

AIM: To evaluate the resistance to cyclic fatigue of ProTaper Next (PTN; Dentsply Sirona, Ballaigues, Switzerland), Revo-S (Micro-Mega, Besançon, France), Mtwo (Sweden & Martina, Padova, Italy), Twisted Files (TF, SybronEndo, Orange, CA, USA) and EndoWave (J Morita Corporation, Osaka, Japan) used in continuous rotation or in reciprocation of Optimum Torque Reverse motion (OTR). METHODOLOGY: A total of 120 nickel-titanium files were tested. Twenty-four instruments for each brand were divided into two groups (n = 12) on the basis of the motion tested: continuous rotation (Group 1) or reciprocation of OTR motion (Group 2). Resistance to cyclic fatigue was determined by recording time to fracture (TtF) in a stainless steel artificial canal with a 60° angle of curvature and 5 mm radius of curvature. The TtF data were analysed by using two-way analysis of variance (anova) and Bonferroni's post hoc tests at 0.05. RESULTS: Mtwo and TF had significantly higher TtF when compared with all other instruments, both in continuous rotation and in reciprocation of OTR motion (P < 0.0001 and P < 0.05, respectively). No difference was observed between Mtwo and TF (P > 0.05), in both motions. PTN was associated with higher cyclic fatigue resistance than Revo-S and EndoWave, both in continuous rotation and in reciprocation of OTR motions (P < 0.0001). No difference was observed between Revo-S and EndoWave, in both motions (P > 0.05). Reciprocating OTR motion improved TtF of all instruments (P < 0.0001). CONCLUSIONS: Reciprocation of OTR motion improved significantly cyclic fatigue resistance of all instruments tested compared with continuous rotation. Mtwo and TF had significantly higher cyclic fatigue than the other instruments, in both continuous rotation and reciprocation of OTR motion.


Assuntos
Ligas , Tratamento do Canal Radicular/instrumentação , Falha de Equipamento , Análise de Falha de Equipamento , Humanos , Microscopia Eletrônica de Varredura , Movimento (Física)
2.
Minerva Chir ; 55(7-8): 541-4, 2000.
Artigo em Italiano | MEDLINE | ID: mdl-11140110

RESUMO

A case of giant hydatid cyst of the left lung submitted to conservative surgery is reported. The postoperative period was complicated by the appearance of a bronchopleural fistula and a residual cavity. The complication was treated with targeted double lumen drainage which enabled pleuroclysis with saline solution and betadine. The closure of the fistula, the elision of the cavity and recovery were accomplished after 95 days. These results demonstrate that conservative surgery is possible even in the presence of giant lung hydatid cyst. Major resections constitute an extreme measure.


Assuntos
Equinococose Pulmonar/cirurgia , Adulto , Anafilaxia/etiologia , Criação de Animais Domésticos , Fístula Brônquica/etiologia , Fístula Brônquica/cirurgia , Drenagem , Equinococose Pulmonar/diagnóstico por imagem , Humanos , Masculino , Doenças Profissionais/diagnóstico por imagem , Doenças Profissionais/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Fístula do Sistema Respiratório/etiologia , Fístula do Sistema Respiratório/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...