Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pediatr Gastroenterol Nutr ; 70(2): 258-260, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31978029

RESUMO

INTRODUCTION: Intraabdominal fluid collections that previously required surgical intervention can now be drained with less invasive techniques. The use of lumen-apposing metal stents (LAMS) to treat pancreatic pseudocysts and perirectal abscesses has been shown to be a safe and effective technique in adults. We aim to evaluate the indications, outcomes, and complications of the use of LAMS in pediatric patients at our institution. METHODS: A retrospective chart review was performed to study patients up to 18 years of age at the Children's Hospital at Montefiore who underwent drainage of intraabdominal fluid collections with the use of LAMS. The main outcome measures were technical and clinical success and associated adverse events with LAMS placement. RESULTS: Seven patients (2 girls) ranging from 9 to 18 years were identified. Four patients had perirectal abscess postperforated appendicitis and 3 patients had pancreatic pseudocysts. All of the patients had complete resolution of the collections, with no recurrence, and our technical and clinical success rate was 100%. Only 1 patient had mild bleeding after placement that spontaneously resolved. DISCUSSION: Our study demonstrates the efficacy and safety of the use of LAMS for the drainage of intraabdominal fluid collections in pediatric patients, although the number of patients included is limited.


Assuntos
Recidiva Local de Neoplasia , Pseudocisto Pancreático , Adulto , Criança , Drenagem , Endossonografia , Feminino , Humanos , Pseudocisto Pancreático/cirurgia , Estudos Retrospectivos , Stents
2.
J Arthroplasty ; 27(2): 238-245.e1, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21723696

RESUMO

Axial torsional loads representative of gait and stair climbing conditions were applied to transverse sections of 8 uncemented postmortem retrievals and a high-resolution imaging system with digital image correlation was used to measure local micromotion along the bone-implant interface. For 7 components that were radiographically stable, there was limited micromotion for gait loading (1.42 ± 1.33 µm) that increased significantly (P = .0032) for stair climb loading (7.32 ± 9.96 µm). A radiographically loose component had motions on the order of 2.3 mm with gait loading. There was a strong inverse relationship between the amount of bone-implant contact (contact fraction) (P = .001) and micromotion. The uncemented components had greater contact fraction (41.8% ± 14.4% vs 11.5% ± 10.2%, P = .0033) and less median micromotion (0.81 ± 0.79 µm vs 28.8 ± 51.1 µm) compared to a previously reported study of cemented retrievals.


Assuntos
Artroplastia de Quadril/instrumentação , Fêmur/cirurgia , Prótese de Quadril , Movimento (Física) , Desenho de Prótese , Autopsia , Fenômenos Biomecânicos , Remoção de Dispositivo , Fêmur/patologia , Marcha , Humanos , Modelos Biológicos , Análise de Regressão , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...