Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Allergy ; 77(2): 633-642, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34241919

RESUMO

BACKGROUND: The aim of the BSP090 project is the establishment of European Pharmacopoeia Chemical Reference Substances (CRSs) in combination with corresponding standard ELISA methods for quantification of major allergens in allergen products. Here, we present data of a Phl p 5-specific sandwich ELISA that proved suitable for the quantification of Phl p 5, one of the major Timothy grass (Phleum pratense) pollen allergens. METHODS: A Phl p 5-specific ELISA system was assessed with respect to accuracy, precision, inter-assay (within laboratory) and inter-laboratory variations, in a ring trial including 14 laboratories in Europe and the USA. Model samples containing recombinant Phl p 5a CRS as well as native grass pollen extracts were analysed. Each participant was instructed to perform at least one preliminary assay to familiarise with the protocol, followed by three independent assays. RESULTS: The candidate standard ELISA proved suitable to quantify recombinant and native Phl p 5 with satisfactory precision (93% of results within ±30% acceptance range). Inter-assay variation (max. GCV 24%) and especially inter-laboratory variation (max. GCV 13%) showed conclusive results. When assessing accuracy by means of recovery of recombinant spikes from a grass pollen extract matrix, similarly satisfactory spike recovery results were observed for the two spikes with higher concentrations (all within ±30% acceptance range), whereas recovery of the lowest concentration spike was slightly poorer with mean results of six laboratories exceeding acceptance range. CONCLUSIONS: Based on the collaborative study results, the assessed Phl p 5-specific immunoassay is appropriate to be proposed as European Pharmacopoeia standard method.


Assuntos
Alérgenos , Pólen , Alérgenos/química , Ensaio de Imunoadsorção Enzimática , Humanos , Phleum/química , Proteínas de Plantas/química , Poaceae , Padrões de Referência
2.
Anal Bioanal Chem ; 411(13): 2755-2758, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30972470

RESUMO

Erythropoietin (EPO) is a glycoprotein hormone which promotes red cell replenishment and is also a global biotherapeutic medicine widely used to treat anaemia resulting, for example, from chemotherapy. Requirements of the European Pharmacopoeia stipulate that the level of dimer must be quantified in clinical EPO products (with a limit of 2%). Quantification is hampered by the lack of reference preparations containing stable measurable levels of EPO dimer, but the reproducible generation of a stable dimerised EPO preparation is challenging. We describe here the development of a lyophilised, chemically cross-linked EPO preparation, which has good stability and may be used for calibration and system suitability assurance for the size exclusion chromatographic separation of EPO preparations. Graphical abstract.


Assuntos
Reagentes de Ligações Cruzadas/química , Eritropoetina/química , Glutaral/química , Calibragem , Cromatografia em Gel/métodos , Cromatografia em Gel/normas , Eritropoetina/análise , Eritropoetina/uso terapêutico , Liofilização , Humanos , Multimerização Proteica , Estabilidade Proteica , Controle de Qualidade , Padrões de Referência
3.
Biologicals ; 42(2): 114-22, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24394373

RESUMO

Regulatory authorities require safety and potency testing prior to the release of each production lot of acellular pertussis (aP)-containing vaccines. Currently, the murine histamine sensitization test (HIST) is used to evaluate the presence of residual pertussis toxin in aP containing vaccines. However, the testing requires the use of a significant number of mice and results in unrelieved pain and distress. NICEATM, ICCVAM, their partners in the International Cooperation on Alternative Test Methods, and the International Working Group for Alternatives to HIST organized a workshop to discuss recent developments in alternative assays to the HIST, review data from an international collaborative study on non-animal alternative tests that might replace the HIST, and address the path toward global acceptance of this type of method. Currently, there are three potential alternative methods to HIST. Participants agreed that no single in vitro method was sufficiently developed for harmonized validation studies at this time. It is unlikely that any single in vitro method would be applicable to all aP vaccines without modification, due to differences between vaccines. Workshop participants recommended further optimization of cell-based assays under development. Participants agreed that the next international collaborative studies should commence in 2013 based on discussions during this workshop.


Assuntos
Histamina/imunologia , Vacina contra Coqueluche/imunologia , Vacinas Acelulares/imunologia , Animais , Internacionalidade , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...