Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 9(11)2020 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-33143217

RESUMO

Retinoblastoma, the most common childhood eye cancer, presents in two forms: heritable or sporadic. Heritable retinoblastoma is caused by a germline mutation in the RB1 gene. Early diagnosis of children at risk of inheriting an RB1 mutation is crucial to achieve optimal clinical outcome. Currently, the majority of genetic testing is performed on newborns, which has multiple disadvantages for both families and the healthcare system. We have developed a non-invasive prenatal diagnosis (NIPD) service for retinoblastoma, available from 8 weeks' gestation, which uses a combination of massively parallel sequencing (MPS) techniques, dependent on the inheritance model. Detection of paternal or suspected de novo RB1 variants is achieved through amplicon-based MPS. NIPD of a fetus at risk of maternal inheritance is performed using capture-based targeted sequencing and relative haplotype dosage analysis. In addition, we show proof of principle of how capture-based sequencing can be used for de novo variants unsuitable for amplicon-based testing. In total, we report the NIPD of 15 pregnancies, results of which show 100% concordance with all postnatal testing performed at the time of publication (n = 12) with remaining pregnancies ongoing. NIPD of retinoblastoma therefore offers a viable alternative to newborn genetic testing.

2.
J Mol Diagn ; 22(9): 1151-1161, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32553884

RESUMO

A relative haplotype dosage (RHDO)-based method was developed and implemented into routine clinical practice for noninvasive prenatal diagnosis (NIPD) of multiple single-gene disorders: spinal muscular atrophy, Duchenne and Becker muscular dystrophies, and cystic fibrosis. This article describes the experiences of the first 152 pregnancies to have NIPD by RHDO as part of a routine clinical service. Provision of results within a clinically useful time frame (mean, 11 calendar days) was shown to be possible, with a very low failure rate (4%), none being due to a technical failure. Where follow-up confirmatory testing was performed for audit purposes, 100% concordance was seen with the NIPD result, and no discrepancies have been reported. The robust performance of the assay, together with high sensitivity and specificity, demonstrates that NIPD by RHDO is feasible for use in a clinical setting.


Assuntos
Fibrose Cística/diagnóstico , Fibrose Cística/genética , Doenças Fetais/diagnóstico , Doenças Fetais/genética , Haplótipos , Distrofia Muscular de Duchenne/diagnóstico , Distrofia Muscular de Duchenne/genética , Teste Pré-Natal não Invasivo/métodos , Diagnóstico Pré-Natal/métodos , Atrofias Musculares Espinais da Infância/diagnóstico , Atrofias Musculares Espinais da Infância/genética , Ácidos Nucleicos Livres/genética , Testes Diagnósticos de Rotina/métodos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Polimorfismo de Nucleotídeo Único , Gravidez , Estudos Retrospectivos , Sensibilidade e Especificidade
3.
Genet Res (Camb) ; 101: e11, 2019 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-31813398

RESUMO

BACKGROUND: Non-invasive prenatal testing (NIPT) for the detection of foetal aneuploidy through analysis of cell-free DNA (cfDNA) in maternal blood is offered routinely by many healthcare providers across the developed world. This testing has recently been recommended for evaluative implementation in the UK National Health Service (NHS) foetal anomaly screening pathway as a contingent screen following an increased risk of trisomy 21, 18 or 13. In preparation for delivering a national service, we have implemented cfDNA-based NIPT in our Regional Genetics Laboratory. Here, we describe our validation and verification processes and initial experiences of the technology prior to rollout of a national screening service. METHODS: Data are presented from more than 1000 patients (215 retrospective and 840 prospective) from 'high- and low-risk pregnancies' with outcome data following birth or confirmatory invasive prenatal sampling. NIPT was by the Illumina Verifi® test. RESULTS: Our data confirm a high-fidelity service with a failure rate of ~0.24% and a high sensitivity and specificity for the detection of foetal trisomy 13, 18 and 21. Secondly, the data show that a significant proportion of patients continue their pregnancies without prenatal invasive testing or intervention after receiving a high-risk cfDNA-based result. A total of 46.5% of patients referred to date were referred for reasons other than high screen risk. Ten percent (76/840 clinical service referrals) of patients were referred with ultrasonographic finding of a foetal structural anomaly, and data analysis indicates high- and low-risk scan indications for NIPT. CONCLUSIONS: NIPT can be successfully implemented into NHS regional genetics laboratories to provide high-quality services. NHS provision of NIPT in patients with high-risk screen results will allow for a reduction of invasive testing and partially improve equality of access to cfDNA-based NIPT in the pregnant population. Patients at low risk for a classic trisomy or with other clinical indications are likely to continue to access cfDNA-based NIPT as a private test.


Assuntos
Ácidos Nucleicos Livres/análise , Testes Genéticos/métodos , Teste Pré-Natal não Invasivo/métodos , Aneuploidia , Ácidos Nucleicos Livres/genética , Síndrome de Down/genética , Feminino , Feto , Humanos , Masculino , Programas Nacionais de Saúde , Gravidez , Diagnóstico Pré-Natal/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Medicina Estatal , Trissomia/genética , Síndrome da Trissomia do Cromossomo 13/genética , Reino Unido
4.
Eur J Hum Genet ; 25(4): 416-422, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28120840

RESUMO

Although technically possible, few clinical laboratories across the world have implemented non-invasive prenatal diagnosis (NIPD) for selected single-gene disorders, mostly owing to the elevated costs incurred. Having previously proven that NIPD for X-linked disorders can be feasibly implemented in clinical practice, we have now developed a test for the NIPD of an autosomal-recessive disorder, spinal muscular atrophy (SMA). Cell-free DNA was extracted from maternal blood and prepared for massively parallel sequencing on an Illumina MiSeq by targeted capture enrichment of single-nucleotide polymorphisms across a 6 Mb genomic window on chromosome 5 containing the SMN1 gene. Maternal, paternal and proband DNA samples were also tested for haplotyping purposes. Sequencing data was analysed by relative haplotype dosage (RHDO). Six pregnant SMA carriers and 10 healthy pregnant donors were recruited through the NIPSIGEN study. Inheritance of the maternally and paternally derived alleles of the affected SMN1 gene was determined in the foetus by RHDO analysis for autosomal-recessive disorders. DNA from the proband (for SMA carriers) or an invasively obtained foetal sample (for healthy pregnant donors) was used to identify the maternal and paternal reference haplotypes associated with the affected SMN1 gene. Results for all patients correlated with known outcomes and showed a testing specificity and sensitivity of 100%. On top of showing high accuracy and reliability throughout the stages of validation, our novel test for NIPD of SMA is also affordable and viable for implementation into clinical service.


Assuntos
Testes Genéticos/métodos , Haplótipos , Atrofia Muscular Espinal/diagnóstico , Diagnóstico Pré-Natal/métodos , Estudos de Casos e Controles , Feminino , Testes Genéticos/normas , Heterozigoto , Humanos , Masculino , Atrofia Muscular Espinal/genética , Linhagem , Polimorfismo de Nucleotídeo Único , Gravidez , Diagnóstico Pré-Natal/normas , Sensibilidade e Especificidade , Proteína 1 de Sobrevivência do Neurônio Motor/genética
5.
Prenat Diagn ; 36(4): 312-20, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26824862

RESUMO

OBJECTIVE: Development of an accurate and affordable test for the non-invasive prenatal diagnosis of Duchenne and Becker muscular dystrophies (DMD/BMD) to implement in clinical practice. METHOD: Cell-free DNA was extracted from maternal blood and prepared for massively parallel sequencing on an Illumina MiSeq by targeted capture enrichment of single nucleotide polymorphisms (SNPs) across the dystrophin gene on chromosome X. Sequencing data were analysed by relative haplotype dosage. RESULTS: Seven healthy pregnant donors and two pregnant DMD carriers all bearing a male fetus were recruited through the non-invasive prenatal diagnosis for single gene disorders study. Non-invasive prenatal diagnosis testing was conducted by relative haplotype dosage analysis for X-linked disorders where the genomic DNA from the chorionic villus sampling (for healthy pregnant donors) or from the proband (for pregnant DMD carriers) was used to identify the reference haplotype. Results for all patients showed a test accuracy of 100%, when the calculated fetal fraction was >4% and correlated with known outcomes. A recombination event was also detected in a DMD patient. CONCLUSION: Our new test for NIPD of DMD/BMD has been shown to be accurate and reliable during initial stages of validation. It is also feasible for implementation into clinical service.


Assuntos
Distrofina/genética , Testes Genéticos/métodos , Haplótipos , Testes para Triagem do Soro Materno/métodos , Distrofia Muscular de Duchenne/diagnóstico , Polimorfismo de Nucleotídeo Único , Estudos de Casos e Controles , Sistema Livre de Células , DNA/sangue , Feminino , Marcadores Genéticos , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Masculino , Distrofia Muscular de Duchenne/genética , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...