Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 37(4): 795-801, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34979253

RESUMO

BACKGROUND: Improving resection accuracy and eliminating outliers in total knee arthroplasty (TKA) is important to improving patient outcomes regardless of alignment philosophy. Robotic-assisted surgical systems improve resection accuracy and reproducibility compared to conventional instrumentation. Some systems require preoperative imaging while others rely on intraoperative anatomic landmarks. We hypothesized that the alignment accuracy of a novel image-free robotic-assisted surgical system would be equivalent or better than conventional instrumentation with fewer outliers. METHODS: Forty cadaveric specimens were used in this study. Five orthopedic surgeons performed 8 bilateral TKAs each, using the VELYS Robotic-Assisted System (DePuy Synthes) and conventional instrumentation on contralateral knees. Pre-resection and postresection computed tomography scans, along with optical scans of the implant positions were performed to quantify resection accuracies relative to the alignment targets recorded intraoperatively. RESULTS: The robotic-assisted cohort demonstrated smaller resection errors compared to conventional instrumentation in femoral coronal alignment (0.63° ± 0.50° vs 1.39° ± 0.95°, P < .001), femoral sagittal alignment (1.21° ± 0.90° vs 3.27° ± 2.51°, P < .001), and tibial coronal alignment (0.93° ± 0.72° vs 1.65° ± 1.29°, P = .001). All other resection angle accuracies were equivalent. Similar improvements were found in the femoral implant coronal alignment (0.89° ± 0.82° vs 1.42° ± 1.15°, P = .011), femoral implant sagittal alignment (1.51° ± 1.08° vs 2.49° ± 2.10°, P = .006), and tibial implant coronal alignment (1.31° ± 0.84° vs 2.03° ± 1.44°, P = .004). The robotic-assisted cohort had fewer outliers (errors >3°) for all angular resection alignments. CONCLUSION: This in vitro study demonstrated that image-free robotic-assisted TKA can improve alignment accuracy compared to conventional instrumentation and reduce the incidence of outliers.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Artroplastia do Joelho/métodos , Cadáver , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Robóticos/métodos , Cirurgia Assistida por Computador/métodos , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA