Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Struct Heart ; 7(4): 100179, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520135

RESUMO

Background: The long-term outcomes of patients undergoing functional assessment of coronary lesions with fractional flow reserve (FFR) while awaiting transcatheter aortic valve implantation (TAVI) are unknown. Data on the safety of intracoronary adenosine use in this setting are scarce. The objectives of this study were to describe (1) the long-term outcomes based on the coronary artery disease (CAD) assessment strategy used and (2) the safety of intracoronary adenosine in patients with severe aortic stenosis (AS). Methods: 1023 patients with severe AS awaiting TAVI were included. Patients were classified according to their CAD assessment strategy: angiography guided or FFR guided. Patients were further subdivided according to the decision to proceed with percutaneous coronary intervention (PCI): angiography-guided PCI (375/1023), angiography-guided no-PCI (549/1023), FFR-guided PCI (50/1023), and FFR-guided no-PCI (49/1023). Patients were followed up for the occurrence of major adverse cardiac and cerebrovascular events (MACCEs). Results: At a mean follow-up of 33.7 months, we observed no significant differences in terms of major adverse cardiovascular and cerebrovascular events (MACCE) in the angiography-guided group (42.4%) compared with the FFR-guided group (37.4%) (p = 0.333). When comparing outcomes of the FFR-guided no-PCI group (32.7%) with the angiography-guided PCI group (46.4%), no significant difference was noted (p = 0.999). Following intracoronary adenosine, a single adverse event occurred. Conclusions: In this population, intracoronary adenosine is safe and well tolerated. We found no significant benefit to an FFR-guided strategy compared with an angiography-guided strategy with respect to MACCEs. Although clinically compelling, avoiding the procedural risks of PCI by deferring the intervention in functionally insignificant lesions failed to show a statistically significant benefit.

2.
Innovations (Phila) ; 18(2): 144-151, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37029653

RESUMO

Animal studies are often required to evaluate new cardiovascular medical devices before they reach the market. Moreover, first-generation novel devices including aortic endovascular prostheses and circulatory support devices are often larger than later iterations or tested in a limited range of sizes. One of the challenges in evaluating these devices is finding a model that is both accessible and anatomically similar to humans, as there is a paucity of data on vascular dimensions in large animals. We set out to complete a comprehensive review of available reports on vascular dimensions in swine, ovine, and bovine models, with a particular focus on the descending aorta and ilio-femoral arteries. We searched Embase and MEDLINE databases for reports of descending aorta and peripheral vascular dimension in large animal models. Data from swine, ovine, and bovine models were separated by weight into 3 categories: 40 to 60 kg, 61 to 80 kg, and >80 kg. We also incorporate our computed tomography angiography data from 4 large sheep and 9 calves into this review. Swine, sheep, and calf >80 kg may serve as the best models to maximize aortic diameter resemblance to humans. If device implantation can be achieved in aortas of smaller dimensions, care should be taken to ensure access site suitability such as the common femoral artery in these smaller animals.


Assuntos
Angiografia , Aorta , Humanos , Animais , Bovinos , Ovinos , Suínos , Angiografia por Tomografia Computadorizada , Modelos Animais
3.
J Invasive Cardiol ; 33(8): E604-E613, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34338651

RESUMO

BACKGROUND: Vascular and bleeding complications related to secondary femoral access site are frequent in patients undergoing transcatheter aortic valve replacement (TAVR), and their occurrence is associated to poorer outcomes. We aimed to evaluate the clinical impact of vascular closure devices (VCDs) for secondary femoral access hemostasis in TAVR procedures. METHODS: This was a multicenter study including 4031 patients who underwent TAVR (mean age, 81 ± 8 years; mean Society of Thoracic Surgeons [STS] score, 4.9 [interquartile range, 3.3-7.6]), and had a secondary femoral access. The 30-day clinical outcomes were analyzed according to femoral access-site hemostasis (manual compression vs VCD), and according to the type of VCD (Perclose [Abbott Cardiovascular] vs Angio-Seal [Terumo Interventional Systems]) using a propensity-matched, multivariable, logistic regression model. RESULTS: Manual compression was used in 941 patients (23.3%) and VCDs were used in 3090 patients (76.7%; Perclose in 1549 patients [38.4%] and Angio-Seal in 1541 patients [38.2%]) for secondary femoral access hemostasis. Vascular complications related to secondary access site occurred in 162 patients (4%), and were more frequent in patients who underwent manual compression (7.2%) compared with VCD hemostasis (3%; adjusted P<.001). In the VCD group, the use of Angio-Seal (vs Perclose) was associated with a higher rate of vascular complications (3.7% vs 2.4%, respectively; adjusted P=.02), femoral artery pseudoaneurysm (1.3% vs 0.4%, respectively; adjusted P<.01), invasive treatment requirement for treating vascular complications (surgery: 0.8% vs 0.3%, respectively [adjusted P=.03]; and thrombin injection: 0.9% vs 0%, respectively [adjusted P<.001]). CONCLUSION: VCDs represented a safer and more effective alternative compared with manual compression for secondary femoral access-site hemostasis in patients undergoing TAVR procedures, and the Perclose VCD was associated with the lowest risk of vascular complications. Future randomized studies are warranted.


Assuntos
Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Hemostasia , Técnicas Hemostáticas , Humanos , Resultado do Tratamento
4.
J Invasive Cardiol ; 33(4): E302-E311, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33600353

RESUMO

OBJECTIVES: To determine the occurrence of vascular complications (VCs) following transfemoral transcatheter aortic valve replacement (TAVR) with new-generation devices according to the use of a crossover technique (COT). BACKGROUND: The use of a COT (with/without balloon) has been associated with a reduction of VCs in TAVR patients. However, scarce data support its use with second-generation devices. Also, its potential benefit in obese patients (at high-risk of VCs) has not been elucidated. METHODS: A multicenter study including 2214 patients who underwent full percutaneous transfemoral TAVR (COT, 1522 patients; no COT, 692 patients). Thirty-day events were evaluated according to the use of a COT using a multivariate logistic regression model. A subanalysis was performed in obese patients. RESULTS: Primary access major VCs (3.5% COT vs 3.9% no COT; P=.19), major/life-threatening bleeding (3.4% COT vs 2.0% no COT; P=.33), and mortality rates (2.4% COT vs 2.6% no COT; P=.23) were similar between groups. However, minor VCs (11.7% COT vs 5.9% no COT; P<.001) and postprocedural acute renal failure (8.9% COT vs 3.9% no COT; P<.001) were higher in patients undergoing the COT. In the overall cohort, percutaneous closure device failure was more frequent in obese patients (4.0% in the obese group vs 1.9% in the non-obese group; P<.01), but these differences were no longer significant in those undergoing a COT (3.4% in the obese group vs 2.0% in the non-obese group; P=.12). Indeed, in the subset of obese patients, the COT tended to be associated with fewer VCs (3.4% COT vs 5.9% no COT; P=.09). CONCLUSIONS: The use of a COT was not associated with a reduction of major VCs or improved outcomes. However, some patient subsets, such as those with higher body mass index, may benefit from the use of a COT. These findings would suggest the application of a tailored strategy, following a risk-benefit assessment in each TAVR candidate.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Hemostasia , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
JACC Cardiovasc Interv ; 13(22): 2601-2613, 2020 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-33069647

RESUMO

OBJECTIVES: This study sought to determine, in patients undergoing percutaneous coronary intervention (PCI) during the work-up pre-transcatheter aortic valve replacement (TAVR): 1) the clinical and peri-procedural PCI characteristics; 2) the long-term outcomes; and 3) the clinical events in those patients with complex coronary features. BACKGROUND: A PCI is performed in about 25% of TAVR candidates, but procedural features and late outcomes of pre-TAVR PCI remain largely unknown. METHODS: Multicenter study including 1197 consecutive patients who had PCI in the work-up pre-TAVR. A total of 1,705 lesions (1.5 ± 0.7 lesions per patient) were included. Death, stroke, myocardial infarction, and major adverse cardiovascular and cerebrovascular events (MACCE) were recorded, as well as target lesion failure (TLF) and target vessel failure (TVF). RESULTS: One-half of patients exhibited a multivessel disease and the mean SYNTAX (SYNergy between PCI with TAXUS and Cardiac Surgery) score was 12.1 ± 9.1. The lesions were of B2/C type, calcified, bifurcation, and ostial in 49.9%, 45.8%, 21.4%, and 19.3% of cases, respectively. After a median follow-up of 2 (interquartile range: 1 to 3) years, a total of 444 (37.1%) patients presented an MACCE. Forty patients exhibited TVF (3.3%), with TLF identified in 32 (2.7%) patients. By multivariable analysis, previous peripheral artery disease (p < 0.001), chronic obstructive pulmonary disease (p = 0.002), atrial fibrillation (p = 0.003), diabetes mellitus (p = 0.012), and incomplete revascularization (p = 0.014) determined an increased risk of MACCE. In patients with unprotected left main or SYNTAX score >32 (n = 128), TLF, TVF, and MACCE rates were 3.9%, 6.3%, and 35.9%, respectively (p = 0.378; p = 0.065, and p = 0.847, respectively, vs. the rest of the population). CONCLUSIONS: Patients undergoing PCI in the work-up pre-TAVR frequently exhibited complex coronary lesions and multivessel disease. PCI was successful in most cases, and TLF and TVF rates at 2-year follow-up were low, also among patients with high-risk coronary features. However, overall MACCE occurred in about one-third of patients, with incomplete revascularization determining an increased risk. These results should inform future studies to better determine the optimal revascularization strategy pre-TAVR.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Humanos , Fatores de Risco , Resultado do Tratamento
6.
Circ Cardiovasc Interv ; 13(8): e009047, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32757657

RESUMO

BACKGROUND: Currently, 2 third-generation transcatheter valves, 29-mm Sapien-3 and 34-mm Evolut-R (ER), are indicated for large sized aortic annuli. We analyzed short and 1-year performance of these valves in patients with large (area ≥575 mm2 or perimeter ≥85 mm) and extra-large (≥683 mm2 or ≥94.2 mm) aortic annuli undergoing transcatheter aortic valve replacement. METHODS: A total of 833 patients across 12 centers with symptomatic aortic stenosis and large aortic annuli underwent transcatheter aortic valve replacement with 29-mm Sapien-3 (n=640) or 34-mm ER (n=193). Clinical, anatomic, and procedural characteristics were collected, and Valve Academic Research Consortium-2 outcomes were reported. RESULTS: Median aortic annulus area and perimeter were 617 mm2 (591-657) and 89.1 mm (87.0-92.1), respectively (704 mm2 [689-743] and 96.0 mm [94.5-97.9] in the subgroup of 124 patients with extra-large annuli). Overall device success was 94.3% (Sapien-3, 95.8% and ER, 89.3%; P=0.001), with a higher rate of significant paravalvular leak (P=0.004), second valve implantation (P=0.013), and valve embolization (P=0.009) in the ER group. Thirty-day and 1-year mortality was 2.4% and 9.2%, respectively, without differences between groups. Valve hemodynamics were excellent (mean gradient, 8.8±3.6 mm Hg; 3.3% rate of moderate-severe paravalvular leak) in the extra-large annulus, without differences compared with the large annulus group. CONCLUSIONS: In patients with large and extra-large aortic annuli, transcatheter aortic valve replacement using 29-mm Sapien-3 and 34-mm ER is safe and feasible. Observed differences in clinical outcomes and hemodynamic performance may guide valve choice in this cohort of patients undergoing transcatheter aortic valve replacement.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Tomada de Decisão Clínica , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , América do Norte , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
7.
J Invasive Cardiol ; 32(6): 235-242, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32428866

RESUMO

OBJECTIVES: We sought to evaluate the position of balloon-expandable valves in relation to the coronary ostia using an angiographic- and computed tomography (CT)-based analysis, and to determine the impact of valve position on coronary angiography (CA)/percutaneous coronary intervention (PCI) feasibility and results. METHODS: A total of 533 patients who received a Sapien XT or Sapien 3 valve were included in the angiographic analysis. Of these, 49 benefited from an opportunistic electrocardiography-gated CT after transcatheter aortic valve replacement (TAVR) and were included in the CT analysis. RESULTS: Regarding the left coronary artery (LCA) ostium, the top of the transcatheter heart valve (THV) frame was infraostial in 49% of cases, and the valve totally covered the LCA ostium in 27% of patients. The stent frame of the Sapien 3 valve completely covered the LCA ostium more frequently than the Sapien XT valve (43% vs 12%, respectively; P<.001) and the relative implantation depth was significantly less ventricular in the Sapien 3 group than in the Sapien XT group (28.0 ± 12.3% vs 36.8 ± 12.6%, respectively; P<.001). The CT evaluation found similar results to angiographic evaluation. A total of 53 patients (10%) underwent CA (± PCI) following TAVR, and valve position did not influence CA performance/quality and PCI results. CONCLUSIONS: The stent frame of balloon-expandable Sapien valves exceeded the coronary ostia in about one-fourth of patients, and this percentage was >40% with the new-generation Sapien 3 valve. However, THV position did not affect the feasibility, quality, and results of CA/PCI post TAVR.


Assuntos
Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
J Invasive Cardiol ; 32(4): 123-128, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32160151

RESUMO

OBJECTIVES: We sought to assess the position of the CoreValve Evolut R/Pro (Medtronic) with respect to the left coronary artery (LCA) ostium and evaluate the impact of implantation depth on this relationship. METHODS: One hundred consecutive patients who received an Evolut R/Pro valve and had an adequate angiography following valve implantation were included. Angiographic measurements included valve implantation depth, the position of the Evolut R/Pro with respect to the LCA, and the distance between the neo-valve cusp and the LCA ostium. Coronary access issues following TAVR were also recorded. RESULTS: Regarding the LCA ostium, the neo-valve of the Evolut R/Pro was supraostial, at the ostial level, and infraostial in 3%, 12%, and 85% of cases, respectively. When beneath the LCA ostium, the mean distance between the neo-valve and the floor of the LCA ostium was 4.1 ± 5.2 mm. An implantation depth ≤6 mm was associated with a higher rate of neo-valve at the ostial level or above (25% vs 4% for implantation depth >6 mm; P=.01). Accessing the coronary arteries was required in 10% of the patients at 12 ± 8 months post TAVR, and selective coronary angiography of the left and right coronary arteries was achieved in 60% and 40% of the cases, respectively. CONCLUSIONS: The Evolut R/Pro neo-valve was positioned below the LCA ostium in the vast majority of cases (85%), but an implantation depth ≤6mm was associated with a higher rate of neo-valve positioning at or above the coronary ostia level. Considering the current tendency of very high (aortic) valve implants to avoid conduction disturbances, future studies should determine the impact of high Evolut R/Pro positioning on coronary access issues post TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Complicações Pós-Operatórias , Desenho de Prótese , Resultado do Tratamento
9.
JACC Cardiovasc Interv ; 13(7): 872-881, 2020 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-32171718

RESUMO

OBJECTIVES: This study sought to determine the incidence, clinical characteristics, associated factors, and outcomes of late cerebrovascular events (LCVEs) (>30 days post-procedure) following transcatheter aortic valve replacement (TAVR). BACKGROUND: Scarce data exist on LCVEs following TAVR. METHODS: This was a multicenter study including 3,750 consecutive patients (mean age, 80 ± 8 years; 50.5% of women) who underwent TAVR and survived beyond 30 days. LCVEs were defined according to the Valve Academic Research Consortium 2 (VARC 2) criteria. RESULTS: LCVEs occurred in 192 (5.1%) patients (stroke, 80.2%; transient ischemic attack, 19.8%) after a median follow-up of 2 (1 to 4) years. Late stroke was of ischemic, hemorrhagic, and undetermined origin in 80.5%, 18.8%, and 0.7% of patients, respectively. Older age, previous cerebrovascular disease, higher mean aortic gradient at baseline, the occurrence of stroke during the periprocedural TAVR period, and the lack of anticoagulation (novel oral anticoagulants or vitamin K antagonists) post-TAVR were independent factors associated with late ischemic stroke/transient ischemic attack (p < 0.05 for all). Echocardiographic data at the time of the LCVE showed no signs of valve thrombosis or degeneration in the vast majority (97%) patients. Late stroke was disabling in 107 (69.5%) patients (ischemic, 68%; hemorrhagic, 79%), and associated with an in-hospital mortality rate of 29.2%. CONCLUSIONS: LCVEs occurred in 5.1% of TAVR recipients after a median follow-up of 2 years. LCVEs were ischemic in most cases, with older age, previous cerebrovascular events, higher mean aortic gradient at baseline, the occurrence during the periprocedural TAVR period, and lack of anticoagulation (but not valve thrombosis/degeneration) determining an increased risk. Late stroke was disabling in most cases and associated with dreadful early and midterm outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Transtornos Cerebrovasculares/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Canadá/epidemiologia , Transtornos Cerebrovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/mortalidade , Feminino , França/epidemiologia , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Estudos Retrospectivos , Fatores de Risco , Espanha/epidemiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
10.
Circ Cardiovasc Interv ; 13(3): e008609, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32089002

RESUMO

BACKGROUND: Transfemoral approach has been commonly used as secondary access in transcatheter aortic valve replacement (TAVR). Scarce data exist on the use and potential clinical benefits of the transradial approach as secondary access during TAVR procedures. The objective of the study is to determine the occurrence of vascular complications (VC) and clinical outcomes according to secondary access (transfemoral versus transradial) in patients undergoing TAVR. METHODS: This was a multicenter study including 4949 patients who underwent TAVR (mean age, 81±8 years, mean Society of Thoracic Surgeons score, 4.9 [3.3-7.5]). Transfemoral and transradial approaches were used as secondary access in 4016 (81.1%) and 933 (18.9%) patients, respectively. The 30-day clinical events (vascular and bleeding complications, stroke, acute kidney injury, and mortality) were evaluated and defined according to Valve Academic Research Consortium-2 criteria. Clinical outcomes were analyzed according to the secondary access (transfemoral versus transradial) in the overall population and in a propensity score-matched population involving 2978 transfemoral and 928 transradial patients. RESULTS: Related-access VC occurred in 834 (16.9%) patients (major VC, 5.7%) and were related to the secondary access in 172 (3.5%) patients (major VC, 1.3%). The rate of VC related to the secondary access was higher in the transfemoral group (VC, 4.1% versus 0.9%, P<0.001; major VC, 1.6% versus 0%, P<0.001). In the propensity score-matched population, VC related to the secondary access remained higher in the transfemoral group (4.7% versus 0.9%, P<0.001; major VC, 1.8% versus 0%, P<0.001), which also exhibited a higher rate of major/life-threatening bleeding events (1.0% versus 0%, P<0.001). Significant differences between secondary access groups were observed regarding the rates of 30-day stroke (transfemoral: 3.1%, transradial: 1.6%; P=0.043), acute kidney injury (transfemoral: 9.9%, transradial: 5.7%; P<0.001), and mortality (transfemoral: 4.0%, transradial: 2.4%, P=0.047). CONCLUSIONS: The use of transradial approach as secondary access in TAVR procedures was associated with a significant reduction in vascular and bleeding complications and improved 30-day outcomes. Future randomized studies are warranted.


Assuntos
Cateterismo Periférico/métodos , Artéria Femoral , Artéria Radial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Canadá , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Bases de Dados Factuais , Europa (Continente) , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Punções , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
11.
Circ Cardiovasc Interv ; 13(2): e008620, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31992059

RESUMO

BACKGROUND: Scarce data exist on coronary events following transcatheter aortic valve replacement (TAVR), and no study has determined the factors associated with poorer outcomes in this setting. This study sought to determine the clinical characteristics, outcomes, and prognostic factors of acute coronary syndrome (ACS) events following TAVR. METHODS: Multicenter cohort study including a total of 270 patients presenting an ACS after a median time of 12 (interquartile range, 5-17) months post-TAVR. Post-ACS death, myocardial infarction, stroke, and overall major adverse cardiovascular or cerebrovascular events were recorded. RESULTS: The ACS clinical presentation consisted of non-ST-segment-elevation myocardial infarction (STEMI) type 2 (31.9%), non-STEMI type 1 (31.5%), unstable angina (28.5%), and STEMI (8.1%). An invasive strategy was used in 163 patients (60.4%), and a percutaneous coronary intervention was performed in 97 patients (35.9%). Coronary access issues were observed in 2.5% and 2.1% of coronary angiography and percutaneous coronary intervention procedures, respectively. The in-hospital mortality rate was 10.0%, and at a median follow-up of 17 (interquartile range, 5-32) months, the rates of death, stroke, myocardial infarction, and major adverse cardiovascular or cerebrovascular events were 43.0%, 4.1%, 15.2%, and 52.6%, respectively. By multivariable analysis, revascularization at ACS time was associated with a reduction of the risk of all-cause death (hazard ratio, 0.54 [95% CI, 0.36-0.81] P=0.003), whereas STEMI increased the risk of all-cause death (hazard ratio, 2.06 [95% CI, 1.05-4.03] P=0.036) and major adverse cardiovascular or cerebrovascular events (hazard ratio, 1.97 [95% CI, 1.08-3.57] P=0.026). CONCLUSIONS: ACS events in TAVR recipients exhibited specific characteristics (ACS presentation, low use of invasive procedures, coronary access issues) and were associated with a poor prognosis, with a very high in-hospital and late death rate. STEMI and the lack of coronary revascularization determined an increased risk. These results should inform future studies to improve both the prevention and management of ACS post-TAVR.


Assuntos
Síndrome Coronariana Aguda/epidemiologia , Angina Instável/epidemiologia , Infarto do Miocárdio sem Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Angina Instável/diagnóstico , Angina Instável/mortalidade , Angina Instável/terapia , Feminino , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea , Medição de Risco , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Espanha/epidemiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
12.
Acad Med ; 95(2): 214, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31990726
13.
Am J Cardiol ; 125(5): 795-802, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31889524

RESUMO

This study sought to determine, in patients with new-onset persistent left bundle branch block (NOP-LBBB) after transcatheter aortic valve implantation (TAVI), the incidence and factors associated with (i) LBBB recovery and (ii) permanent pacemaker implantation (PPI) at 1-year follow-up. This was a multicenter study including 153 patients (mean age: 81 ± 5 years, 56% of women) with NOP-LBBB post-TAVI (balloon-expandable valve in 112 patients). Delta PR (ΔPR) and delta QRS (ΔQRS) were defined as the difference in PR and QRS length between baseline and hospital discharge ECG, and the relative ΔPR and ΔQRS as absolute ΔPR and ΔQRS divided by baseline PR and QRS length, respectively. The patients had a clinical visit and 12-lead ECG at 1-year follow-up. LBBB recovery was observed in 50 patients (33%), and 14 patients (9%) had advanced conduction disturbances requiring PPI during the follow-up period. No clinical or ECG variables were associated with LBBB recovery, including prosthesis type (self- or balloon-expandable valve, p = 0.563), QRS width at baseline/discharge or absolute/relative ΔQRS (p >0.10 for all). The presence of atrial fibrillation at baseline (0.026), a longer PR interval at discharge (0.009), and a longer absolute and relative ΔPR (p = 0.002 and p = 0.004, respectively) were associated with an increased risk of PPI at 1-year follow-up. In conclusion, NOP-LBBB post-TAVI resolved in one-third of patients at 1-year follow-up, but no clinical or ECG variables were associated with LBBB recovery. Conversely, a nonsinus rhythm at baseline and a longer ΔPR were associated with an increased risk of PPI within the year after TAVI.


Assuntos
Valva Aórtica/cirurgia , Bloqueio de Ramo/fisiopatologia , Estimulação Cardíaca Artificial , Eletrocardiografia , Complicações Pós-Operatórias/fisiopatologia , Recuperação de Função Fisiológica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/epidemiologia , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/terapia , Comorbidade , Feminino , Humanos , Incidência , Masculino , Marca-Passo Artificial , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/terapia
14.
JACC Cardiovasc Interv ; 11(24): 2523-2533, 2018 12 24.
Artigo em Inglês | MEDLINE | ID: mdl-30573061

RESUMO

OBJECTIVES: The authors sought to assess the incidence, predictors, management, and prognosis of acute coronary syndrome (ACS) following TAVR. BACKGROUND: About one-half of the patients undergoing transcatheter aortic valve replacement (TAVR) have concurrent coronary artery disease (CAD). However, the occurrence and clinical impact of coronary events following TAVR remain largely unknown. METHODS: Consecutive patients undergoing TAVR in our institution between May 2007 and November 2017 were included. Patients were followed at 1, 6, and 12 months, and yearly thereafter. ACS was diagnosed and classified according to the Third Universal Definition of Myocardial Infarction. RESULTS: A total of 779 patients (mean age 79 ± 9 years, 52% male, mean STS: 6.8 ± 5.1%) were included, 68% of which had a history of CAD. At a median follow-up of 25 (interquartile range: 10 to 44) months, 78 patients (10%) presented at least 1 episode of ACS, with one-half of the events occurring within the year following TAVR. Clinical presentation was type 2 non-ST-segment elevation myocardial infarction (35.9%), unstable angina (34.6%), type 1 non-ST-segment elevation myocardial infarction (28.2%), and ST-segment elevation myocardial infarction (1.3%). Male sex (hazard ratio [HR]: 2.19; 95% confidence interval [CI]: 1.36 to 3.54; p = 0.001), prior CAD (HR: 2.78; 95% CI: 1.50 to 5.18; p = 0.001), and nontransfemoral approach (HR: 1.71; 95% CI: 1.04 to 2.75; p = 0.035) were independently associated with ACS. Coronary angiography was performed in 53 (67.9%) patients with ACS, and 30 of them (56.6%) underwent percutaneous coronary intervention. In-hospital death rate at the time of the ACS episode was 3.8%. At a median follow-up of 21 (interquartile range: 8 to 34) months post-ACS, all-cause and cardiovascular death rates were 37.3% and 25.3%, respectively. CONCLUSIONS: Approximately one-tenth of patients undergoing TAVR were readmitted for an ACS after a median follow-up of 25 months. Male sex, prior CAD, and nontransfemoral approach were independent predictors of ACS. ACS was associated with high midterm mortality.


Assuntos
Síndrome Coronariana Aguda/epidemiologia , Angina Instável/epidemiologia , Infarto do Miocárdio sem Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Angina Instável/diagnóstico por imagem , Angina Instável/mortalidade , Angina Instável/terapia , Feminino , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Readmissão do Paciente , Intervenção Coronária Percutânea , Quebeque/epidemiologia , Medição de Risco , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Fatores de Tempo , Resultado do Tratamento
15.
Circulation ; 136(7): 632-643, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28588077

RESUMO

BACKGROUND: At present, there are no objective data specifically examining the clinical impact of variations in exercise capacity post-transcatheter aortic valve replacement (TAVR). We describe the changes in exercise capacity between baseline and 6 months post-TAVR, and ascertain factors associated with and clinical implications of a lack of improvement in exercise capacity post-TAVR. METHODS: A total of 305 patients (mean age, 79±9 years; 44% men; Society of Thoracic Surgeons predicted risk mortality score, 6.7±4.2%) undergoing TAVR completed both baseline and follow-up exercise capacity assessments at 6 months post-TAVR. Exercise capacity was evaluated by the 6-minute walk test (6MWT). Clinical outcomes were compared between patients displaying greater than (n=152; improving group) versus less than (n=153; nonimproving group) the median percentage change in distance walked between baseline and 6-month follow-up examinations. The primary outcome measure was clinical event rates, measured from the 6-month post-TAVR period onward. Further dichotomization according to baseline 6MWT distance (less than versus more than median walking distance, or slow walker versus fast walker) was also assessed. RESULTS: The mean overall distances walked pre- and post-TAVR (6 months post-TAVR) were 204±119 and 263±116 m, respectively (Δ6MWT=60±106 m), with 219 (72%) patients demonstrating an increase in their walking distance (median percentage increase of the entire population was 20% [interquartile range, 0%-80%]). Factors independently correlated with reduced exercise capacity improvement included a range of baseline clinical characteristics (older age, female sex, chronic obstructive pulmonary disease; P<0.05 for all), periprocedural major or life-threatening bleeding (P=0.009) and new-onset anemia at 6 months post-TAVR (P=0.009). Failure to improve the 6MWT distance by at least 20% was independently associated with all-cause mortality (P=0.002) and cardiovascular death or rehospitalization for cardiovascular causes (P=0.001). Baseline slow walkers who were able to improve the 6MWT distance presented with significantly better outcomes than nonimprovers (P=0.01 for all-cause mortality; P=0.001 for cardiovascular end point). CONCLUSIONS: Approximately one-third of patients undergoing TAVR did not improve their exercise capacity postprocedure. The lack of functional improvement post-TAVR was predicted by a mix of baseline and periprocedural factors translating into poorer clinical outcomes. These results suggest that systematically implementing exercise capacity assessment pre- and post-TAVR may help to improve patient risk stratification.


Assuntos
Estenose da Valva Aórtica/cirurgia , Terapia por Exercício , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/terapia , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Análise Multivariada , Prognóstico , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...