Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
J Am Med Inform Assoc ; 30(1): 178-194, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36125018

RESUMO

How to deliver best care in various clinical settings remains a vexing problem. All pertinent healthcare-related questions have not, cannot, and will not be addressable with costly time- and resource-consuming controlled clinical trials. At present, evidence-based guidelines can address only a small fraction of the types of care that clinicians deliver. Furthermore, underserved areas rarely can access state-of-the-art evidence-based guidelines in real-time, and often lack the wherewithal to implement advanced guidelines. Care providers in such settings frequently do not have sufficient training to undertake advanced guideline implementation. Nevertheless, in advanced modern healthcare delivery environments, use of eActions (validated clinical decision support systems) could help overcome the cognitive limitations of overburdened clinicians. Widespread use of eActions will require surmounting current healthcare technical and cultural barriers and installing clinical evidence/data curation systems. The authors expect that increased numbers of evidence-based guidelines will result from future comparative effectiveness clinical research carried out during routine healthcare delivery within learning healthcare systems.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Atenção à Saúde , Computadores
2.
Artigo em Inglês | MEDLINE | ID: mdl-34299682

RESUMO

The Mayan population of Guatemala is understudied within eye and vision research. Studying an observational homogenous, geographically isolated population of individuals seeking eye care may identify unique clinical, demographic, environmental and genetic risk factors for blinding eye disease that can inform targeted and effective screening strategies to achieve better and improved health care distribution. This study served to: (a) identify the ocular health needs within this population; and (b) identify any possible modifiable risk factors contributing to disease pathophysiology within this population. We conducted a cross-sectional study with 126 participants. Each participant completed a comprehensive eye examination, provided a blood sample for genetic analysis, and received a structured core baseline interview for a standardized epidemiological questionnaire at the Salama Lions Club Eye Hospital in Salama, Guatemala. Interpreters were available for translation to the patients' native dialect, to assist participants during their visit. We performed a genome-wide association study for ocular disease association on the blood samples using Illumina's HumanOmni2.5-8 chip to examine single nucleotide polymorphism SNPs in this population. After implementing quality control measures, we performed adjusted logistic regression analysis to determine which genetic and epidemiological factors were associated with eye disease. We found that the most prevalent eye conditions were cataracts (54.8%) followed by pseudoexfoliation syndrome (PXF) (24.6%). The population with both conditions was 22.2%. In our epidemiological analysis, we found that eye disease was significantly associated with advanced age. Cataracts were significantly more common among those living in the 10 districts with the least resources. Furthermore, having cataracts was associated with a greater likelihood of PXF after adjusting for both age and sex. In our genetic analysis, the SNP most nominally significantly associated with PXF lay within the gene KSR2 (p < 1 × 10-5). Several SNPs were associated with cataracts at genome-wide significance after adjusting for covariates (p < 5 × 10-8). About seventy five percent of the 33 cataract-associated SNPs lie within 13 genes, with the majority of genes having only one significant SNP (5 × 10-8). Using bioinformatic tools including PhenGenI, the Ensembl genome browser and literature review, these SNPs and genes have not previously been associated with PXF or cataracts, separately or in combination. This study can aid in understanding the prevalence of eye conditions in this population to better help inform public health planning and the delivery of quality, accessible, and relevant health and preventative care within Salama, Guatemala.


Assuntos
Catarata , Síndrome de Exfoliação , Catarata/etnologia , Catarata/genética , Estudos Transversais , Síndrome de Exfoliação/etnologia , Síndrome de Exfoliação/genética , Estudo de Associação Genômica Ampla , Guatemala/epidemiologia , Humanos , Indígenas Centro-Americanos
3.
J Am Med Inform Assoc ; 28(6): 1330-1344, 2021 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-33594410

RESUMO

Clinical decision-making is based on knowledge, expertise, and authority, with clinicians approving almost every intervention-the starting point for delivery of "All the right care, but only the right care," an unachieved healthcare quality improvement goal. Unaided clinicians suffer from human cognitive limitations and biases when decisions are based only on their training, expertise, and experience. Electronic health records (EHRs) could improve healthcare with robust decision-support tools that reduce unwarranted variation of clinician decisions and actions. Current EHRs, focused on results review, documentation, and accounting, are awkward, time-consuming, and contribute to clinician stress and burnout. Decision-support tools could reduce clinician burden and enable replicable clinician decisions and actions that personalize patient care. Most current clinical decision-support tools or aids lack detail and neither reduce burden nor enable replicable actions. Clinicians must provide subjective interpretation and missing logic, thus introducing personal biases and mindless, unwarranted, variation from evidence-based practice. Replicability occurs when different clinicians, with the same patient information and context, come to the same decision and action. We propose a feasible subset of therapeutic decision-support tools based on credible clinical outcome evidence: computer protocols leading to replicable clinician actions (eActions). eActions enable different clinicians to make consistent decisions and actions when faced with the same patient input data. eActions embrace good everyday decision-making informed by evidence, experience, EHR data, and individual patient status. eActions can reduce unwarranted variation, increase quality of clinical care and research, reduce EHR noise, and could enable a learning healthcare system.


Assuntos
Sistema de Aprendizagem em Saúde , Tomada de Decisão Clínica , Computadores , Documentação , Registros Eletrônicos de Saúde , Humanos
4.
Ophthalmol Glaucoma ; 4(1): 5-9, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32810611

RESUMO

Advances in the field of predictive modeling using artificial intelligence and machine learning have the potential to improve clinical care and outcomes, but only if the results of these models are presented appropriately to clinicians at the time they make decisions for individual patients. Clinical decision support (CDS) systems could be used to accomplish this. Modern CDS systems are computer-based tools designed to improve clinician decision making for individual patients. However, not all CDS systems are effective. Four principles that have been shown in other medical fields to be important for successful CDS system implementation are (1) integration into clinician workflow, (2) user-centered interface design, (3) evaluation of CDS systems and rules, and (4) standards-based development so the tools can be deployed across health systems.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Glaucoma , Inteligência Artificial , Glaucoma/diagnóstico , Humanos , Aprendizado de Máquina
5.
J Clin Med ; 9(11)2020 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-33171720

RESUMO

BACKGROUND: The American Indian Navajo and Goshute peoples are underserved patient populations residing in the Four Corners area of the United States and Ibupah, Utah, respectively. METHODS: We conducted a cross-sectional study of epidemiological factors and lipid biomarkers that may be associated with type II diabetes, hypertension and retinal manifestations in tribal and non-tribal members in the study areas (n = 146 participants). We performed multivariate analyses to determine which, if any, risk factors were unique at the tribal level. Fundus photos and epidemiological data through standardized questionnaires were collected. Blood samples were collected to analyze lipid biomarkers. Univariate analyses were conducted and statistically significant factors at p < 0.10 were entered into a multivariate regression. RESULTS: Of 51 participants for whom phenotyping was available, from the Four Corners region, 31 had type II diabetes (DM), 26 had hypertension and 6 had diabetic retinopathy (DR). Of the 64 participants from Ibupah with phenotyping available, 20 had diabetes, 19 had hypertension and 6 had DR. Navajo participants were less likely to have any type of retinopathy as compared to Goshute participants (odds ratio (OR) = 0.059; 95% confidence interval (CI) = 0.016-0.223; p < 0.001). Associations were found between diabetes and hypertension in both populations. Older age was associated with hypertension in the Four Corners, and the Navajo that reside there on the reservation, but not within the Goshute and Ibupah populations. Combining both the Ibupah, Utah and Four Corners study populations, being American Indian (p = 0.022), residing in the Four Corners (p = 0.027) and having hypertension (p < 0.001) increased the risk of DM. DM (p < 0.001) and age (p = 0.002) were significantly associated with hypertension in both populations examined. When retinopathy was evaluated for both populations combined, hypertension (p = 0.037) and living in Ibupah (p < 0.001) were associated with greater risk of retinopathy. When combining both American Indian populations from the Four Corners and Ibupah, those with hypertension were more likely to have DM (p < 0.001). No lipid biomarkers were found to be significantly associated with any disease state. CONCLUSIONS: We found different comorbid factors with retinal disease outcome between the two tribes that reside within the Intermountain West. This is indicated by the association of tribe and with the type of retinopathy outcome when we combined the populations of American Indians. Overall, the Navajo peoples and the Four Corners had a higher prevalence of chronic disease that included diabetes and hypertension than the Goshutes and Ibupah. To the best of our knowledge, this is the first study to conduct an analysis for disease outcomes exclusively including the Navajo and Goshute tribe of the Intermountain West.

7.
Ophthalmology ; 126(1): 29-37, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29945799

RESUMO

OBJECTIVE: To compare cataract surgery with implantation of a Schlemm canal microstent with cataract surgery alone for the reduction of intraocular pressure (IOP) and medication use after 24 months. DESIGN: Prospective, multicenter, single-masked, randomized controlled trial. PARTICIPANTS: Subjects with concomitant primary open-angle glaucoma (POAG), visually significant cataract, and washed-out modified diurnal IOP (MDIOP) between 22 and 34 mmHg. METHODS: Subjects were randomized 2:1 to receive a single Hydrus Microstent (Ivantis, Inc, Irvine, CA) in the Schlemm canal or no stent after uncomplicated phacoemulsification. Comprehensive eye examinations were conducted 1 day, 1 week, and 1, 3, 6, 12, 18, and 24 months postoperatively. Medication washout and MDIOP measurement were repeated at 12 and 24 months. MAIN OUTCOME MEASURES: The primary and secondary effectiveness end points were the proportion of subjects demonstrating a 20% or greater reduction in unmedicated MDIOP and change in mean MDIOP from baseline at 24 months, respectively. Hypotensive medication use was tracked throughout the course of follow-up. Safety measures included the frequency of surgical complications and adverse events. RESULTS: A total of 369 eyes were randomized after phacoemulsification to Hydrus Microstent (HMS) and 187 to no microstent (NMS). At 24 months, unmedicated MDIOP was reduced by ≥20% in 77.3% of HMS group eyes and in 57.8% of NMS group eyes (difference = 19.5%, 95% confidence interval [CI] 11.2%-27.8%, P < 0.001). The mean reduction in 24-month unmedicated MDIOP was -7.6±4.1 mmHg (mean ± standard deviation) in the HMS group and -5.3±3.9 mmHg in the NMS group (difference = -2.3 mmHg; 95% CI, -3.0 to -1.6; P < 0.001). The mean number of medications was reduced from 1.7±0.9 at baseline to 0.3±0.8 at 24 months in the HMS group and from 1.7±0.9 to 0.7±0.9 in the NMS group (difference = -0.4 medications; P < 0.001). There were no serious ocular adverse events related to the microstent, and no significant differences in safety parameters between the 2 groups. CONCLUSIONS: This 24-month multicenter randomized controlled trial demonstrated superior reduction in MDIOP and medication use among subjects with mild-to-moderate POAG who received a Schlemm canal microstent combined with phacoemulsification compared with phacoemulsification alone.


Assuntos
Catarata/etiologia , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular/fisiologia , Limbo da Córnea/cirurgia , Facoemulsificação/métodos , Stents , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/administração & dosagem , Humor Aquoso/fisiologia , Catarata/fisiopatologia , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Gonioscopia , Humanos , Implante de Lente Intraocular , Masculino , Estudos Prospectivos , Implantação de Prótese , Método Simples-Cego , Tonometria Ocular , Acuidade Visual
8.
Clin Ophthalmol ; 12: 2553-2561, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30573945

RESUMO

Historically, visual acuity has been the benchmark for visual function. It is used to measure therapeutic outcomes for vision-related services, products and interventions. Quantitative measurement of suboptimal visual acuity can potentially be corrected optically with proper refraction in some cases, but in many cases of reduced vision there is something else more serious that can potentially impact other aspects of visual function such as contrast sensitivity, color discrimination, peripheral field of view and higher-order visual processing. The measurement of visual acuity typically requires stimuli subject to some degree of standardization or calibration and has thus often been limited to clinical settings. However, we are spending increasing amounts of time interacting with devices that present high-resolution, full color images and video (hereafter, digital media) and can record our responses. Most of these devices can be used to measure visual acuity and other aspects of visual function, not just with targeted testing experiences but from typical device interactions. There is growing evidence that prolonged exposure to digital media can lead to various vision-related issues (eg, computer vision syndrome, dry eye, etc.). Our regular, daily interactions (digital behavior) can also be used to assess our visual function, passively and continuously. This allows us to expand vision health assessment beyond the clinic, to collect vision-related data in the whole range of settings for typical digital behavior from practically any population(s) of interest and to further explore just how our increasingly virtual interactions are affecting our vision. We present a tool that can be easily integrated into digital media to provide insights into our digital behavior.

9.
J Gen Physiol ; 150(12): 1660-1675, 2018 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-30446509

RESUMO

Mechanotransduction by the trabecular meshwork (TM) is an essential component of intraocular pressure regulation in the vertebrate eye. This process is compromised in glaucoma but is poorly understood. In this study, we identify transient receptor potential vanilloid isoform 4 (TRPV4) and TWIK-related potassium channel-1 (TREK-1) as key molecular determinants of TM membrane potential, pressure sensitivity, calcium homeostasis, and transcellular permeability. We show that resting membrane potential in human TM cells is unaffected by "classical" inhibitors of voltage-activated, calcium-activated, and inwardly rectifying potassium channels but is depolarized by blockers of tandem-pore K+ channels. Using gene profiling, we reveal the presence of TREK-1, TASK-1, TWIK-2, and THIK transcripts in TM cells. Pressure stimuli, arachidonic acid, and TREK-1 activators hyperpolarize these cells, effects that are antagonized by quinine, amlodipine, spadin, and short-hairpin RNA-mediated knockdown of TREK-1 but not TASK-1. Activation and inhibition of TREK-1 modulates [Ca2+]TM and lowers the impedance of cell monolayers. Together, these results suggest that tensile homeostasis in the TM may be regulated by balanced, pressure-dependent activation of TRPV4 and TREK-1 mechanotransducers.


Assuntos
Sinalização do Cálcio , Mecanotransdução Celular , Canais de Potássio de Domínios Poros em Tandem/fisiologia , Malha Trabecular/metabolismo , Adulto , Ácido Araquidônico , Humanos , Potenciais da Membrana , Pessoa de Meia-Idade , Pressão , Cultura Primária de Células , Canais de Cátion TRPV/fisiologia , Malha Trabecular/citologia
10.
J Glaucoma ; 27 Suppl 1: S102-S104, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29965904

RESUMO

Cataract extraction in exfoliation syndrome requires careful preoperative assessment and planning. Knowledge of the degree of pupil dilation and zonular integrity are essential for safely perform cataract surgery in these eyes. Capsule rhexis should be 5.5 mm and all intraoperative maneuvers should be designed to minimize zonular stress. The surgeon should be versatile in various nuclear disassembly techniques and consider use of capsular support devices when warranted. Cortical cleanup should proceed via a tangential approach and attempts should be made to removal residual lens epithelial cells so as to minimize postoperative capsular contraction syndrome.


Assuntos
Extração de Catarata/métodos , Síndrome de Exfoliação/complicações , Humanos , Pressão Intraocular , Complicações Intraoperatórias/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle
11.
J Cataract Refract Surg ; 44(5): 603-609, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29752046

RESUMO

PURPOSE: To report the long-term outcomes of transscleral fixation of capsular tension rings (CTR) with intraocular lens (IOL) placement in pediatric patients with ectopia lentis. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN: Retrospective case series. METHODS: Pediatric patients requiring lens extraction with transscleral capsular bag fixation with a CTR and IOL for ectopia lentis between January 2006 and January 2016 were analyzed. RESULTS: Thirty-seven patients (67 eyes) who had transscleral fixation of the capsular bag using a CTR fixated with 9-0 or 10-0 polypropylene (Prolene), 8-0 polytetrafluoroethylene (Gore-Tex), or 9-0 nylon were identified. The mean age at time of surgery was 7.25 years (2 to 18 years) and the mean follow-up was 35.3 months (0.25 to 120 months). The proportion of eyes showing improvement in corrected distance visual acuity (CDVA) postoperatively was 78.5%, which demonstrated significance with a 95% confidence interval. In the immediate postoperative period, 1 eye developed a hyphema and 1 eye required IOL repositioning. Long-term complications included posterior capsule opacification in 35 eyes (52%) and uveitis-glaucoma-hyphema syndrome in 1 eye (1.5%). Three eyes (4.4 %) required IOL repositioning for spontaneous delayed IOL dislocation, 2 sutured with 8-0 polytetrafluoroethylene at postoperative month 8 and postoperative year 3 and 1 sutured with 9-0 polypropylene at postoperative year 7. CONCLUSION: Transscleral fixation of the capsular bag using a CTR improved CDVA and provided IOL stability in pediatric patients with ectopia lentis.


Assuntos
Ectopia do Cristalino/cirurgia , Cápsula do Cristalino/cirurgia , Implante de Lente Intraocular/métodos , Esclera/cirurgia , Técnicas de Sutura , Acuidade Visual , Adolescente , Criança , Pré-Escolar , Ectopia do Cristalino/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
12.
J Cataract Refract Surg ; 43(5): 590-592, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28602317

RESUMO

We describe clinical applications and surgical techniques for a new type of capsular tension segment (CTS) for use during cataract surgery. The Ambati CTS is distinguished from other CTS devices by having 2 eyelets close to each other, which allows it to distribute tension to 2 points, avoiding too much stress at a single point on the anterior capsulotomy, which prevents peaking of the capsulorhexis, and potentially reducing the risk for anterior capsule tear. Two of these CTS devices could possibly be used to provide 4-point fixation of a capsular bag in eyes with near-complete zonular instability. We describe 4 cases and 2 surgical techniques for implanting the new CTS, 1 technique in an adult patient with zonular weakness secondary to trauma and the other in 3 children with subluxated lenses due to Marfan syndrome.


Assuntos
Capsulorrexe , Extração de Catarata , Subluxação do Cristalino , Adulto , Capsulorrexe/métodos , Extração de Catarata/métodos , Criança , Humanos , Subluxação do Cristalino/cirurgia , Síndrome de Marfan/complicações
13.
J Clin Med ; 5(9)2016 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-27618115

RESUMO

UNLABELLED: This study determined the degree of adherence to medications for glaucoma among patients refilling prescriptions in community pharmacies. METHODS: Data abstracted from the dispensing records for 3615 adult patients (18 years or older, predominantly over 45) receiving glaucoma medications from two retail pharmacy chains (64 stores in total) were analyzed. From a 24-month historic data capture period, the 12-month levels of adherence were determined using standard metrics, the proportion of days covered (PDC) and the medication possession ratio (MPR). The overall 12-month mean PDC was only 57%, and the mean MPR was 71%. Using a criterion by which 80% coverage was considered satisfactory adherence, only 30% had satisfactory overall 12-month PDC coverage, and only 37% had satisfactory overall 12-month MPR coverage. Refill adherence increased with age and was highest in the 65-and-older age group (p < 0.001). Differential adherence was found across medication classes, with the highest satisfactory coverage seen for those taking alpha2-adrenergic agonists (PDC = 36.0%; MPR = 47.6%) down to those taking direct cholinergic agonists (PDC = 25.0%; MPR = 31.2%) and combination products (PDC = 22.7%; MPR = 31.0%). Adherence to glaucoma medications in the community setting, as measured by pharmacy refill data, is very poor and represents a critical target for intervention. Community pharmacists are well positioned to monitor and reinforce adherence in this population.

14.
J Cataract Refract Surg ; 42(7): 1100-1101, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27669085
16.
J Glaucoma ; 24(8): 591-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25393037

RESUMO

PURPOSE: To report and compare the results of trabeculectomy with mitomycin C (MMC) and Ahmed valve implantation in the management of uveitic glaucoma. PATIENTS AND METHODS: The records of 41 eyes of 29 patients who underwent trabeculectomy with MMC or Ahmed valve implantation for uveitic glaucoma were retrospectively reviewed. Seventeen eyes underwent trabeculectomy with MMC, and 24 eyes underwent Ahmed valve implantation. Outcomes included postoperative intraocular pressure (IOP), percent reduction from preoperative IOP, postoperative number of medications, time to failure, and complications. RESULTS: Mean follow-up was 21.2 months in the trabeculectomy group and 23.8 months in the valve group (P=0.06). Mean IOP was reduced from 29.2 to 18.4 mm Hg in the trabeculectomy group (31.3%), compared with a reduction from 33.4 to 15.5 mm Hg in the Ahmed valve group (42.7%, P=0.53). Postoperatively, 1.76 medications were used in the trabeculectomy group, compared with 1.83 medications in the Ahmed valve group (P=0.89). Cumulative success at 1 year was 66.7% in the trabeculectomy group, compared with 100% in the Ahmed valve group (P=0.02). Mean time to failure was 8.36 months with trabeculectomy, and 21.8 months with Ahmed valve (P=0.02). Complications in both groups were typically rare and self-limited, with recurrent inflammation being most common. CONCLUSIONS: Although both trabeculectomy with MMC and Ahmed valve implantation are reasonable surgical options in the management of uncontrolled uveitic glaucoma, Ahmed valve implantation was associated with higher cumulative success rate at 1 year and a longer mean time to failure.


Assuntos
Alquilantes/administração & dosagem , Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Mitomicina/administração & dosagem , Trabeculectomia/métodos , Uveíte/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Terapia Combinada , Túnica Conjuntiva/efeitos dos fármacos , Feminino , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Implantação de Prótese , Estudos Retrospectivos , Tonometria Ocular , Resultado do Tratamento , Uveíte/fisiopatologia
17.
J Cataract Refract Surg ; 40(11): 1913-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25241325

RESUMO

UNLABELLED: We describe the case of a 70-year-old woman who had phacoemulsification and implantation of a single-piece hydrophobic acrylic multifocal intraocular lens (IOL). Following surgery, the patient experienced blurring, positive dysphotopsia, impaired night vision, and glare. After 2 years, optic damage likely related to the IOL injection procedure was noted. The IOL was successfully exchanged. The uncorrected distance visual acuity was 20/20, and the patient reported no further visual aberrations. Gross and microscopic examination revealed large linear scratches on the central part of the optic. Scheimpflug photography with densitometry analysis of the area of the anterior scratches revealed extremely high levels of surface backlight scattering (227 computer-compatible tape units). Modulation transfer function and Badal images of the explanted IOL and of a control IOL did not differ significantly. This report suggests that severe defects/damage such as those described would likely be clinically significant in IOLs with specialized optics and warrant immediate removal/exchange of a damaged multifocal IOL. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Complicações Intraoperatórias , Lentes Intraoculares , Falha de Prótese , Transtornos da Visão/etiologia , Idoso , Remoção de Dispositivo , Feminino , Humanos , Implante de Lente Intraocular , Facoemulsificação , Reoperação
18.
J Cataract Refract Surg ; 40(9): 1561-4, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25135550

RESUMO

UNLABELLED: We present the case of an 81-year-old man with pseudoexfoliation syndrome (PXF) in whom spontaneous bilateral anterior partial in-the-bag intraocular lens (IOL) dislocation was diagnosed following a routine dilated examination that demonstrated only mild pseudophacodonesis with no evidence of subluxation. Uneventful cataract surgery with placement of single-piece hydrophobic acrylic posterior chamber IOLs had been performed in both eyes 7 years previously. Bilateral IOL repositioning with scleral fixation was performed to correct the dislocation. Postoperative examinations showed remarkable improvement in visual acuity and IOL stability. We hypothesize that zonular weakness secondary to PXF predisposed the patient to bilateral IOL partial dislocation. Pupil dilation in the setting of mild pseudophacodonesis at the time of routine examination may have been a precipitating factor. To our knowledge, bilateral IOL subluxation/dislocation has been described in a limited number of case reports. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Exame Físico , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/cirurgia , Síndrome de Exfoliação/complicações , Humanos , Implante de Lente Intraocular , Masculino , Facoemulsificação , Reoperação , Esclera/cirurgia , Técnicas de Sutura
20.
J Glaucoma ; 23(4): 254-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-22922664

RESUMO

The current method for implantation of the Ex-PRESS Glaucoma Filtration Device requires a conjunctival peritomy and shunt insertion under the guarded protection of a scleral flap. This technique requires suture closure of the flap and conjunctiva. A new minimally invasive technique for Ex-PRESS shunt implantation allows for insertion through a scleral tunnel originating from a grooved clear corneal incision. This new method avoids the need for conjunctival dissection and closure and offers the advantages of eliminating conjunctival wound leaks while maintaining the protection of a partial thickness scleral covering. This new technique may offer a faster safer means for shunt implantation with the potential for less conjunctival scarring.


Assuntos
Túnica Conjuntiva/cirurgia , Síndrome de Exfoliação/cirurgia , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Implantação de Prótese/métodos , Síndrome de Exfoliação/fisiopatologia , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Retalhos Cirúrgicos , Técnicas de Sutura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...