Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-36833979

RESUMO

Uroflowmetry (UF) is a crucial guideline-recommended tool for men with benign prostatic obstruction (BPO). Moreover, UF is a helpful decision-making tool for the management of patients with lower urinary tract symptoms (LUTS) and benign prostatic hyperplasia (BPH). In the last few years, telemedicine and telehealth have increased exponentially as cost-effective treatment options for both patients and physicians. Telemedicine and telehealth have been well positioned during the COVID-19 pandemic to prevent healthcare system overload and to ensure adequate management of patients through screening, diagnosis, and follow-up at home. In the present manuscript, the main characteristics and performance of a novel and low-cost device for home-based UF have been analyzed. The simple weight-transducer method has been applied to perform UF. An inexpensive load cell connected to a 24 bit analogic digital converter (ADC) sends data to a cloud server via SIM card or home Wi-Fi. Data are processed and shown in graphics with both volume and flow rate as a function of time, allowing for measurement of average flow rate, maximum flow rate, voided volume, and voiding time. A numerical algorithm allows for filtering of the dynamic effect due to the urine gravity acceleration and for removing the funnel to simplify the home measurement procedure. Through an online platform, the physician can see and compare each UF data. The device's reliability has been validated in a first laboratory setting and showed excellent performance. This approach based on domiciliary tests and an online platform can revolutionize the urologic clinic landscape by offering a constant patient cost-effective follow-up, eliminating the time wasted waiting in the office setting.


Assuntos
COVID-19 , Hiperplasia Prostática , Masculino , Humanos , Reprodutibilidade dos Testes , Pandemias , Micção , Urodinâmica
2.
Sensors (Basel) ; 22(2)2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-35062496

RESUMO

This work addresses the design, development and implementation of a 4.0-based wearable soft transducer for patient-centered vitals telemonitoring. In particular, first, the soft transducer measures hypertension-related vitals (heart rate, oxygen saturation and systolic/diastolic pressure) and sends the data to a remote database (which can be easily consulted both by the patient and the physician). In addition to this, a dedicated deep learning algorithm, based on a Long-Short-Term-Memory Autoencoder, was designed, implemented and tested for providing an alert when the patient's vitals exceed certain thresholds, which are automatically personalized for the specific patient. Furthermore, a mobile application (EcO2u) was developed to manage the entire data flow and facilitate the data fruition; this application also implements an innovative face-detection algorithm that ensures the identity of the patient. The robustness of the proposed soft transducer was validated experimentally on five individuals, who used the system for 30 days. The experimental results demonstrated an accuracy in anomaly detection greater than 93%, with a true positive rate of more than 94%.


Assuntos
Aprendizado Profundo , Aplicativos Móveis , Algoritmos , Humanos , Saturação de Oxigênio , Transdutores
3.
Sci Rep ; 12(1): 673, 2022 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-35027630

RESUMO

A personalized model of the human knee for enhancing the inter-individual reproducibility of a measurement method for monitoring Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) after transdermal delivery is proposed. The model is based on the solution of Maxwell Equations in the electric-quasi-stationary limit via Finite Element Analysis. The dimensions of the custom geometry are estimated on the basis of knee circumference at the patella, body mass index, and sex of each individual. An optimization algorithm allows to find out the electrical parameters of each subject by experimental impedance spectroscopy data. Muscular tissues were characterized anisotropically, by extracting Cole-Cole equation parameters from experimental data acquired with twofold excitation, both transversal and parallel to tissue fibers. A sensitivity and optimization analysis aiming at reducing computational burden in model customization achieved a worst-case reconstruction error lower than 5%. The personalized knee model and the optimization algorithm were validated in vivo by an experimental campaign on thirty volunteers, 67% healthy and 33% affected by knee osteoarthritis (Kellgren-Lawrence grade ranging in [1,4]), with an average error of 3%.


Assuntos
Anti-Inflamatórios não Esteroides/administração & dosagem , Anti-Inflamatórios não Esteroides/farmacocinética , Articulação do Joelho/metabolismo , Osteoartrite do Joelho/tratamento farmacológico , Osteoartrite do Joelho/metabolismo , Administração Cutânea , Algoritmos , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Modelos Anatômicos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...