Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
J Anal Toxicol ; 48(2): 99-103, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37952088

RESUMO

Current guidelines recommend universal screening for substance use disorders in obstetric patients, and neonatal drug testing is also frequently performed. Meconium is often the preferred specimen type to detect neonatal drug exposure due to a longer window of detection compared to urine, but most laboratories send out meconium testing to specialized reference laboratories, which can delay results for several days or more. Here, we evaluate a rapid and definitive liquid chromatography-tandem mass spectrometry method for neonatal urine drug testing and compare results obtained using this method to paired meconium drug testing in 1,424 neonates for amphetamines, cocaine, cannabinoids, opiates, oxycodone and phencyclidine. Urine testing showed equivalent sensitivity to current meconium methods for detecting in utero exposure to amphetamines and cocaine.


Assuntos
Líquidos Corporais , Cocaína , Metanfetamina , Recém-Nascido , Feminino , Gravidez , Humanos , Mecônio , Detecção do Abuso de Substâncias
2.
J Med Toxicol ; 19(4): 362-367, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37695470

RESUMO

INTRODUCTION: Ethylene glycol (EG) is a frequently considered toxicant in poisoned patients. Definitive diagnosis relies on gas chromatography (GC), but this is unavailable at most hospitals. A glycerol dehydrogenase (GDH)-based assay rapidly detects EG. A rapid turnaround time and wide availability of necessary instrumentation suggest this method could facilitate the rapid detection of EG. METHODS: This is a prospective, observational analysis of banked, remnant serum samples submitted to the laboratory of a large, multi-hospital healthcare system. Samples were submitted over a 12-month period for the explicit purpose of testing for suspected EG ingestion. All samples underwent GC and the GDH-based assay. RESULTS: Of the 118 analyzed samples, 88 had no EG detected by GC, and 30 were "positive." At the manufacturer's threshold of 6 mg/dL EG, there was 100% (95%CI; 88.7-100) positive percent agreement (PPA) and 98% (92.1-99.6) negative percent agreement (NPA). Adjusted to a threshold of 9 mg/dL, both the PPA and NPA were 100%. Deming regression of the observed concentrations revealed a slope of 1.16 (1.01 to 1.32) and intercept of -5.3 (-8.9 to -1.7). CONCLUSIONS: The GDH assay provides a sensitive and specific method for the detection and quantification of EG that is comparable to a GC-based method. More widespread use of this rapid, inexpensive assay could improve the care of patients with suspected toxic alcohol exposure. Further study is needed to evaluate the test performance in real-time patient treatment decisions.


Assuntos
Substâncias Perigosas , Desidrogenase do Álcool de Açúcar , Humanos , Nonoxinol
3.
PLoS One ; 18(2): e0281365, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36763574

RESUMO

BACKGROUND: As diagnostic tests for COVID-19 were broadly deployed under Emergency Use Authorization, there emerged a need to understand the real-world utilization and performance of serological testing across the United States. METHODS: Six health systems contributed electronic health records and/or claims data, jointly developed a master protocol, and used it to execute the analysis in parallel. We used descriptive statistics to examine demographic, clinical, and geographic characteristics of serology testing among patients with RNA positive for SARS-CoV-2. RESULTS: Across datasets, we observed 930,669 individuals with positive RNA for SARS-CoV-2. Of these, 35,806 (4%) were serotested within 90 days; 15% of which occurred <14 days from the RNA positive test. The proportion of people with a history of cardiovascular disease, obesity, chronic lung, or kidney disease; or presenting with shortness of breath or pneumonia appeared higher among those serotested compared to those who were not. Even in a population of people with active infection, race/ethnicity data were largely missing (>30%) in some datasets-limiting our ability to examine differences in serological testing by race. In datasets where race/ethnicity information was available, we observed a greater distribution of White individuals among those serotested; however, the time between RNA and serology tests appeared shorter in Black compared to White individuals. Test manufacturer data was available in half of the datasets contributing to the analysis. CONCLUSION: Our results inform the underlying context of serotesting during the first year of the COVID-19 pandemic and differences observed between claims and EHR data sources-a critical first step to understanding the real-world accuracy of serological tests. Incomplete reporting of race/ethnicity data and a limited ability to link test manufacturer data, lab results, and clinical data challenge the ability to assess the real-world performance of SARS-CoV-2 tests in different contexts and the overall U.S. response to current and future disease pandemics.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Estados Unidos/epidemiologia , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiologia , RNA , Pandemias , Teste para COVID-19
4.
PLoS One ; 18(2): e0279956, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36735683

RESUMO

BACKGROUND: Real-world performance of COVID-19 diagnostic tests under Emergency Use Authorization (EUA) must be assessed. We describe overall trends in the performance of serology tests in the context of real-world implementation. METHODS: Six health systems estimated the odds of seropositivity and positive percent agreement (PPA) of serology test among people with confirmed SARS-CoV-2 infection by molecular test. In each dataset, we present the odds ratio and PPA, overall and by key clinical, demographic, and practice parameters. RESULTS: A total of 15,615 people were observed to have at least one serology test 14-90 days after a positive molecular test for SARS-CoV-2. We observed higher PPA in Hispanic (PPA range: 79-96%) compared to non-Hispanic (60-89%) patients; in those presenting with at least one COVID-19 related symptom (69-93%) as compared to no such symptoms (63-91%); and in inpatient (70-97%) and emergency department (93-99%) compared to outpatient (63-92%) settings across datasets. PPA was highest in those with diabetes (75-94%) and kidney disease (83-95%); and lowest in those with auto-immune conditions or who are immunocompromised (56-93%). The odds ratios (OR) for seropositivity were higher in Hispanics compared to non-Hispanics (OR range: 2.59-3.86), patients with diabetes (1.49-1.56), and obesity (1.63-2.23); and lower in those with immunocompromised or autoimmune conditions (0.25-0.70), as compared to those without those comorbidities. In a subset of three datasets with robust information on serology test name, seven tests were used, two of which were used in multiple settings and met the EUA requirement of PPA ≥87%. Tests performed similarly across datasets. CONCLUSION: Although the EUA requirement was not consistently met, more investigation is needed to understand how serology and molecular tests are used, including indication and protocol fidelity. Improved data interoperability of test and clinical/demographic data are needed to enable rapid assessment of the real-world performance of in vitro diagnostic tests.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Estados Unidos/epidemiologia , COVID-19/diagnóstico , COVID-19/epidemiologia , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Testes Sorológicos
5.
Emerg Infect Dis ; 28(3): 672-683, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35202525

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serosurveys can estimate cumulative incidence for monitoring epidemics, requiring assessment of serologic assays to inform testing algorithm development and interpretation of results. We conducted a multilaboratory evaluation of 21 commercial high-throughput SARS-CoV-2 serologic assays using blinded panels of 1,000 highly characterized specimens. Assays demonstrated a range of sensitivities (96%-63%), specificities (99%-96%), and precision (intraclass correlation coefficient 0.55-0.99). Durability of antibody detection was dependent on antigen and immunoglobulin targets; antispike and total Ig assays demonstrated more stable longitudinal reactivity than antinucleocapsid and IgG assays. Assays with high sensitivity, specificity, and durable antibody detection are ideal for serosurveillance, but assays demonstrating waning reactivity are appropriate for other applications, including correlation with neutralizing activity and detection of anamnestic boosting by reinfections. Assay performance must be evaluated in context of intended use, particularly in the context of widespread vaccination and circulation of SARS-CoV-2 variants.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , COVID-19/diagnóstico , COVID-19/epidemiologia , Humanos , Sensibilidade e Especificidade , Testes Sorológicos/métodos
6.
Endocr Connect ; 11(2)2022 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-35015702

RESUMO

Objectives: Recently, an estradiol immunoassay manufacturer (Beckman Coulter, USA) issued an 'important product notice' alerting clinical laboratories that their assay (Access Sensitive Estradiol) was not indicated for patients undergoing exogenous estradiol treatment. The objective of this analysis was to evaluate immunoassay bias relative to liquid chromatography tandem mass spectrometry (LC-MS/MS) in transgender women and to examine the influence of unconjugated estrone on measurements. Design: Cross-sectional secondary analysis. Methods: Estradiol concentrations from 89 transgender women were determined by 3 immunoassays (Access Sensitive Estradiol ('New BC') and Access Estradiol assays ('Old BC'), Beckman Coulter; Estradiol III assay ('Roche'), Roche Diagnostics) and LC-MS/MS. Bias was evaluated with and without adjustment for estrone concentrations. The number of participants who shifted between three estradiol concentration ranges for each immunoassay vs LC-MS/MS (>300 pg/mL, 70-300 pg/mL, and <70 pg/mL) was calculated. Results: The New BC assay had the largest magnitude overall bias (median: -34%) and was -40%, -22%, and -10%, among participants receiving tablet, patch, or injection preparations, respectively. Overall bias was -12% and +17% for the Roche and Old BC assays, respectively. When measured with the New BC assay, 18 participants shifted to a lower estradiol concentration range (vs 9 and 10 participants based on Roche or Old BC assays, respectively). Adjustment for estrone did not minimize bias. Conclusions: Immunoassay measurement of estradiol in transgender women may lead to falsely decreased concentrations that have the potential to affect management. A multidisciplinary health care approach is needed to ensure if appropriate analytical methods are available.

7.
Antimicrob Resist Infect Control ; 10(1): 163, 2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34809702

RESUMO

BACKGROUND: Early evaluations of healthcare professional (HCP) COVID-19 risk occurred during insufficient personal protective equipment and disproportionate testing, contributing to perceptions of high patient-care related HCP risk. We evaluated HCP COVID-19 seropositivity after accounting for community factors and coworker outbreaks. METHODS: Prior to universal masking, we conducted a single-center retrospective cohort plus cross-sectional study. All HCP (1) seen by Occupational Health for COVID-like symptoms (regardless of test result) or assigned to (2) dedicated COVID-19 units, (3) units with a COVID-19 HCP outbreak, or (4) control units from 01/01/2020 to 04/15/2020 were offered serologic testing by an FDA-authorized assay plus a research assay against 67 respiratory viruses, including 11 SARS-CoV-2 antigens. Multivariable models assessed the association of demographics, job role, comorbidities, care of a COVID-19 patient, and geocoded socioeconomic status with positive serology. RESULTS: Of 654 participants, 87 (13.3%) were seropositive; among these 60.8% (N = 52) had never cared for a COVID-19 patient. Being male (OR 1.79, CI 1.05-3.04, p = 0.03), working in a unit with a HCP-outbreak unit (OR 2.21, CI 1.28-3.81, p < 0.01), living in a community with low owner-occupied housing (OR = 1.63, CI = 1.00-2.64, p = 0.05), and ethnically Latino (OR 2.10, CI 1.12-3.96, p = 0.02) were positively-associated with COVID-19 seropositivity, while working in dedicated COVID-19 units was negatively-associated (OR 0.53, CI = 0.30-0.94, p = 0.03). The research assay identified 25 additional seropositive individuals (78 [12%] vs. 53 [8%], p < 0.01). CONCLUSIONS: Prior to universal masking, HCP COVID-19 risk was dominated by workplace and community exposures while working in a dedicated COVID-19 unit was protective, suggesting that infection prevention protocols prevent patient-to-HCP transmission. Prior to universal masking, HCP COVID-19 risk was dominated by workplace and community exposures while working in a dedicated COVID-19 unit was protective, suggesting that infection prevention protocols prevent patient-to-HCP transmission.


Assuntos
COVID-19/prevenção & controle , Pessoal de Saúde , Controle de Infecções , Centros Médicos Acadêmicos , Adulto , California/epidemiologia , Infecções Comunitárias Adquiridas , Estudos Transversais , Surtos de Doenças , Feminino , Humanos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Análise de Regressão , Estudos Retrospectivos , Fatores de Risco
8.
J Appl Lab Med ; 6(5): 1143-1154, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34240171

RESUMO

BACKGROUND: Racial disparities in SARS-CoV-2 prevalence are apparent. Race is a sociocultural construct, necessitating investigation into how sociocultural factors contribute. METHODS: This cross-sectional study linked laboratory data of adult patients between February 29 and May 15, 2020 with socio-demographics variables from the 2018 American Community Survey (ACS). Medical sites included healthcare organizations in Michigan, New York, North Carolina, California, Florida, Pennsylvania, and Washington. Race was treated as a proxy for racism and not biological essentialism. Laboratory data included patient age, sex, race, ethnicity, test result, test location, and residential ZIP code. ACS data included economic and educational variables contributing to an SES Index, population density, proportion Medicaid, and racial composition for corresponding ZIP code. Associations between race/socioeconomic variables and test results were examined using odds ratios (OR). RESULTS: Of 126 452 patients [mean (SD) age 51.9 (18.4) years; 52 747 (41.7%) men; 68 856 (54.5%) White and 27 805 (22.0%) Black], 18 905 (15.0%) tested positive. Of positive tests, 5238 (SD 27.7%) were White and 7223 (SD 38.2%) were Black. Black race increased the odds of a positive test; this finding was consistent across sites [OR 2.11 (95% CI 1.95-2.29)]. When subset by race, higher SES increased the odds of a positive test for White patients [OR 1.10 (95% CI 1.05-1.16)] but decreased the odds for Black patients [OR 0.92 (95% CI 0.86-0.99)]. Black patients, but not White patients, who tested positive overwhelmingly resided in more densely populated areas. CONCLUSIONS: Black race was associated with SARS-CoV-2 positivity and the relationship between SES and test positivity differed by race, suggesting the impact of socioeconomic status on test positivity is race-specific.


Assuntos
COVID-19 , SARS-CoV-2 , Fatores Socioeconômicos , Adulto , População Negra , COVID-19/diagnóstico , Teste para COVID-19 , Estudos Transversais , Feminino , Disparidades nos Níveis de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Estados Unidos , População Branca
10.
11.
Crit Rev Clin Lab Sci ; 57(3): 146-160, 2019 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-31680585

RESUMO

Increasing laboratory automation and efficiency requires quality assurance (QA) approaches to ensure that reported results are precise and accurate. Prerequisites for designing optimal QA strategies include an in-depth understanding of the laboratory processes, the expected results, and of the mechanisms that can cause erroneous results. Oftentimes, a laboratory's own data, extracted from the laboratory information system, electronic medical record, and/or clinical data warehouse are necessary to master the aforementioned requirements. Data-driven QA utilizes retrospective and/or prospective laboratory results to minimize errors in the clinical laboratory due to pre-analytical or analytical vulnerabilities. Additionally, exploitation of this data may improve result interpretation. The objective of this review is to illustrate specific examples of data-driven QA approaches for several areas of the clinical laboratory and for different phases of the testing cycle.

12.
Clin Chem ; 64(9): 1294-1295, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30154198
13.
Clin Chem ; 64(8): 1265-1266, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30054304
14.
Clin Biochem ; 50(4-5): 168-173, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27836621

RESUMO

OBJECTIVES: Point of care (POC) whole blood lactate testing may facilitate rapid detection of sepsis. We evaluated three POC methods against both plasma lactate comparison methods and a flow-injection mass spectrometric (MS) method. DESIGN AND METHODS: Nova StatStrip, Abbott i-STAT CG4+ and Radiometer ABL90 POC lactate methods were evaluated against the mean of Cobas Integra 400 and Vitros 350 plasma lactate. POC methods were also compared to a flow-injection mass spectrometric assay measuring lactate in ZnSO4-precipitated whole blood extracts. Intra- and inter-assay precision was determined using quality control material. Method comparison included specimens from normal donors at rest, after exertion, and after spiking with lactic acid. RESULTS: Intra- and inter-assay coefficient of variation was <5% for i-STAT and ABL90; but ranged from 3.1-8.2% on two StatStrip meters. Mean (±SD) bias between POC and plasma lactate ranged from -0.2±0.9 (i-STAT and ABL90) to -0.4±1.2 (StatStrip) mmol/L. At concentrations >6mmol/L, all POC methods showed proportional negative bias compared to plasma methods; but this bias was not observed when compared to the MS method. Despite proportional negative bias, all POC methods demonstrated acceptable concordance (94-100%) with plasma lactate within the reference interval (<2.3mmol/L) and >4mmol/L, commonly used clinical cut-offs for detection of sepsis. CONCLUSIONS: POC lactate methods demonstrate acceptable concordance with plasma lactate across commonly used clinical cut-offs for detection of sepsis. Due to systematic negative bias at higher lactate concentrations, POC and plasma lactate should not be used interchangeably to monitor patients with elevated lactate concentrations.


Assuntos
Análise Química do Sangue/instrumentação , Ácido Láctico/sangue , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Padrões de Referência , Sepse/sangue , Sepse/diagnóstico
16.
Clin Chim Acta ; 439: 50-7, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25314938

RESUMO

Hemoglobin disorders are recognized as one of the most common inherited diseases worldwide. Detecting and characterizing variant hemoglobins and thalassemias depends primarily on clinical laboratory methods. Multiple biophysical, biochemical, and genetic assays are available to provide phenotypic or genotypic evidence of pathology. For many years conventional slab-gel electrophoresis and HPLC were the most commonly utilized laboratory methods. However, the field has rapidly expanded to regularly include capillary zone electrophoresis, molecular assays, and, more recently, mass spectrometric assays. Interpretation of these techniques is, in general, complicated because of the involvement of multiple polymorphic genes. Proper characterization of hemoglobin variants is necessary for diagnosis, primary prevention and genetic counseling for underlying disorders. This review provides an overview of the current hemoglobin analysis techniques, and also discusses technologies that have potential to translate into widespread clinical settings.


Assuntos
Hemoglobinopatias/sangue , Hemoglobinopatias/diagnóstico , Hemoglobinas/análise , Hemoglobinas/química , Hemoglobinas/genética , Humanos , Análise Espectral
17.
Bioanalysis ; 6(21): 2839-53, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25486231

RESUMO

Urine specimens submitted for pain management drug testing often contain multiple psychotherapeutic drugs, in addition to opioids. Immunoassay-based screen-and-confirm approaches typically used for clinical drug testing have limited sensitivity to detect therapeutic concentrations of many drugs prescribed in pain management and do not differentiate between drugs in the same class. In addition, screening for all the various illicit and prescription drugs that may be present in the pain management population requires as many as 10-20 individual immunoassays. High-resolution MS approaches have the potential to transform the way clinical drug testing is performed for pain management.


Assuntos
Analgésicos/urina , Espectrometria de Massas , Analgésicos/uso terapêutico , Benzodiazepinas/urina , Monitoramento de Medicamentos , Humanos , Imunoensaio , Dor/tratamento farmacológico , Manejo da Dor
18.
J Pediatr Endocrinol Metab ; 27(7-8): 657-60, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24572984

RESUMO

Vitamin D status is best reflected by circulating concentrations of 25-hydroxyvitamin D2 and D3 (25-OH-D). An adequate blood concentration of total 25-OH-D is commonly defined as that which maintains parathyroid hormone (PTH) within the normal range. Consensus from studies of adults with renal impairment indicates that 75 nmol/L of 25-OH-D maintains suppression of PTH. No similar consensus exists in children. We studied the correlation of PTH and 25-OH-D in 271 patients aged 2 months to 21 years (mean 11 years) in a tertiary care pediatric setting. Patients with renal impairment were excluded by elevated creatinine concentration and chart review. PTH did not significantly correlate with 25-OH-D concentrations >25 nmol/L. PTH was significantly elevated in specimens with <25 nmol/L of 25-OH-D (p=10-17). Using PTH suppression as indicator, these data suggest that 25-OH-D concentrations >25 nmol/L in children indicate vitamin D sufficiency.


Assuntos
Hormônio Paratireóideo/sangue , Vitamina D/análogos & derivados , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Valores de Referência , Vitamina D/sangue , Adulto Jovem
20.
J Anal Toxicol ; 36(9): 601-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22995480

RESUMO

To evaluate liquid chromatography-high-resolution mass spectrometry (LC-HR-MS) for urine toxicology screening, 29 analytes were quantitated in 152 urine specimens from patients with chronic pain using two unique mass spectrometry platforms. De-identified specimens were quantitated in April of 2011 by liquid chromatography-triple quadrupole mass spectrometry (LC-MS-MS) and by full-scan LC-HR-MS at Millennium Laboratories. Considering LC-MS-MS as the reference method, false positive results were identified in 19 specimens measured by LC-HR-MS. Application of relative retention times using deuterium labeled internal standards improved the rate of false positive detection to only five specimens, with four occurring for the same analyte. Ultra-high-resolution mass spectrometry (R = 100,000 at m/z 200) showed no improvement over high-resolution mass spectrometry (R = 10,000 at m/z 200) in the number of false positives detected. Quantitative results measured by LC-MS-MS and LC-HR-MS showed good agreement over four orders of dynamic range. This study demonstrates that LC-HR-MS is a suitable platform for toxicology screening for a pain management population and that quantitative accuracy and sensitivity are comparable to that achieved with LC-MS-MS. The specificity of LC-HR-MS is improved by the addition of deuterium labeled internal standards and the implementation of relative retention time matching.


Assuntos
Analgésicos/análise , Cromatografia Líquida/métodos , Manejo da Dor , Espectrometria de Massas em Tandem/métodos , Urinálise/métodos , Dor Crônica/tratamento farmacológico , Deutério/análise , Humanos , Sensibilidade e Especificidade , Manejo de Espécimes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...