Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Eng Technol ; 15(3): 264-278, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38448643

RESUMO

INTRODUCTION: In native heart tissue, functions of cardiac fibroblasts (CFs) include synthesis, remodeling, and degradation of the extracellular matrix (ECM) as well as secreting factors that regulate cardiomyocyte (CM) function. The influence of direct co-culture and CF-derived ECM on CM mechanical function are not fully understood. METHODS: Here we use an engineered culture platform that provides control over ECM geometry and substrate stiffness to evaluate the influence of iPSC-CFs, and the ECM they produce, on the mechanical function of iPSC-CMs. Mechanical analysis was performed using digital image correlation to quantify maximum contractile strain, spontaneous contraction rate, and full-field organization of the contractions. RESULTS: When cultured alone, iPSC-CFs produce and remodel the ECM into fibers following the underlying 15° chevron patterned ECM. The substrates were decellularized and confirmed to have highly aligned fibers that covered a large fraction of the pattern area before reseeding with iPSC-CMs, alone or in co-culture with iPSC-CFs. When seeded on decellularized ECM, larger maximum contractile strains were observed in the co-culture condition compared to the CM Only condition. No significant difference was found in contractile strain between the Matrigel and decellularized ECM conditions; however, the spontaneous contraction rate was lower in the decellularized ECM condition. A methodology for quantifying alignment of cell contraction across the entire field of view was developed based on trajectories approximating the cell displacements during contraction. Trajectory alignment was unaltered by changes in culture or ECM conditions. CONCLUSIONS: These combined observations highlight the important role CFs play in vivo and the need for models that enable a quantitative approach to examine interactions between the CFs and CMs, as well as the interactions of these cells with the ECM.


Assuntos
Técnicas de Cocultura , Matriz Extracelular , Fibroblastos , Células-Tronco Pluripotentes Induzidas , Miócitos Cardíacos , Miócitos Cardíacos/fisiologia , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo , Células-Tronco Pluripotentes Induzidas/citologia , Células-Tronco Pluripotentes Induzidas/metabolismo , Fibroblastos/metabolismo , Matriz Extracelular/metabolismo , Humanos , Contração Miocárdica , Células Cultivadas , Mecanotransdução Celular , Matriz Extracelular Descelularizada , Diferenciação Celular , Engenharia Tecidual/métodos
2.
Front Bioeng Biotechnol ; 10: 873531, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35620470

RESUMO

Catecholaminergic polymorphic ventricular tachycardia (CPVT) is characterized by an arrhythmogenic mechanism involving disruption of calcium handling. This genetic disease can lead to sudden death in children and young adults during physical or emotional stress. Prior CPVT studies have focused on calcium handling, but mechanical functionality has rarely been investigated in vitro. In this research we combine stem cell-derived cardiomyocytes from a CPVT patient (RyR2-H2464D mutation) and a healthy familial control with an engineered culture platform to evaluate mechanical function of cardiomyocytes. Substrates with Young's modulus ranging from 10 to 50 kPa were used in conjunction with microcontact printing of ECM proteins into defined patterns for subsequent attachment. Digital Image Correlation (DIC) was used to evaluate collections of contracting cells. The amplitude of contractile strain was utilized as a quantitative indicator of functionality and disease severity. We found statistically significant differences: the maximum contractile strain was consistently higher in patient samples compared to control samples on all substrate stiffnesses. Additionally, the patient cell line had a statistically significantly slower intrinsic contraction rate than the control, which agrees with prior literature. Differences in mechanical strain have not been previously reported, and hypercontractility is not a known characteristic of CPVT. However, functional changes can occur as the disease progresses, thus this observation may not represent behavior observed in adolescent and adult patients. These results add to the limited studies of mechanical function of CPVT CMs reported in literature and identify functional differences that should be further explored.

3.
Physiol Rep ; 9(19): e15045, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34617673

RESUMO

In native heart tissue, cardiac fibroblasts provide the structural framework of extracellular matrix (ECM) while also influencing the electrical and mechanical properties of cardiomyocytes. Recent advances in the field of stem cell differentiation have led to the availability of human pluripotent stem cell-derived cardiac fibroblasts (iPSC-CFs) in addition to cardiomyocytes (iPSC-CMs). Here we use a novel 2D in vitro micropatterned platform that provides control over ECM geometry and substrate stiffness. When cultured alone on soft micropatterned substrates, iPSC-CFs are confined to the micropatterned features and remodel the ECM into anisotropic fibers. Similar remodeling and ECM production occurs when cultured with iPSC-CMs in a co-culture model. In addition to modifications in the ECM, our results show that iPSC-CFs influence iPSC-CM function with accelerated Ca2+ transient rise-up time and greater contractile strains in the co-culture conditions compared to when iPSC-CMs are cultured alone. These combined observations highlight the important role cardiac fibroblasts play in vivo and the need for co-culture models like the one presented here to provide more representative in vitro cardiac constructs.


Assuntos
Matriz Extracelular/metabolismo , Fibroblastos/metabolismo , Miócitos Cardíacos/metabolismo , Diferenciação Celular/fisiologia , Técnicas de Cocultura , Fibroblastos/citologia , Humanos , Células-Tronco Pluripotentes Induzidas/citologia , Células-Tronco Pluripotentes Induzidas/metabolismo , Miócitos Cardíacos/citologia
4.
Biotechnol Bioeng ; 118(1): 442-452, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32990953

RESUMO

Human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) have emerged as an exciting new tool for cardiac research and can serve as a preclinical platform for drug development and disease modeling studies. However, these aspirations are limited by current culture methods in which hPSC-CMs resemble fetal human cardiomyocytes in terms of structure and function. Herein we provide a novel in vitro platform that includes patterned extracellular matrix with physiological substrate stiffness and is amenable to both mechanical and electrical analysis. Micropatterned lanes promote the cellular and myofibril alignment of hPSC-CMs while the addition of micropatterned bridges enable formation of a functional cardiac syncytium that beats synchronously over a large two-dimensional area. We investigated the electrophysiological properties of the patterned cardiac constructs and showed they have anisotropic electrical impulse propagation, as occurs in the native myocardium, with speeds 2x faster in the primary direction of the pattern as compared to the transverse direction. Lastly, we interrogated the mechanical function of the pattern constructs and demonstrated the utility of this platform in recording the strength of cardiomyocyte contractions. This biomimetic platform with electrical and mechanical readout capabilities will enable the study of cardiac disease and the influence of pharmaceuticals and toxins on cardiomyocyte function. The platform also holds potential for high throughput evaluation of drug safety and efficacy, thus furthering our understanding of cardiovascular disease and increasing the translational use of hPSC-CMs.


Assuntos
Fenômenos Eletrofisiológicos , Células Gigantes/metabolismo , Miocárdio/metabolismo , Miócitos Cardíacos/metabolismo , Linhagem Celular , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo
5.
Exp Mech ; 59(9): 1235-1248, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31680699

RESUMO

Well-controlled 2D cell culture systems advance basic investigations in cell biology and provide innovative platforms for drug development, toxicity testing, and diagnostic assays. These cell culture systems have become more advanced in order to provide and to quantify the appropriate biomechanical and biochemical cues that mimic the milieu of conditions present in vivo. Here we present an innovative 2D cell culture system to investigate human stem cell-derived cardiomyocytes, the muscle cells of the heart responsible for pumping blood throughout the body. We designed our 2D cell culture platform to control intracellular features to produce adult-like cardiomyocyte organization with connectivity and anisotropic conduction comparable to the native heart, and combined it with optical microscopy to quantify cell-cell and cell-substrate mechanical interactions. We show the measurement of forces and displacements that occur within individual cells, between neighboring cells, and between cells and their surrounding matrix. This system has broad potential to expand our understanding of tissue physiology, with particular advantages for the study of the mechanically active heart. Furthermore, this technique should prove valuable in screening potential drugs for efficacy and testing for toxicity.

6.
Ann Biomed Eng ; 38(8): 2485-98, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20411334

RESUMO

An effort to understand the development of breast cancer motivates the study of mammary gland cells and their interactions with the extracellular matrix. A mixture of mammary gland epithelial cells (normal murine mammary gland), collagen, and fluorescent beads was loaded into microchannels and observed via four-dimensional imaging. Collagen concentrations of 1.3, 2, and 3 mg/mL were used. The displacements of the beads were used to calculate strains in the 3D matrix. To ensure physiologically relevant materials properties for analysis, the collagen was characterized using independent tensile testing with strain rates in the range of those measured in the cell-gel constructs. 3D elastic theory for an isotropic material was employed to calculate the stress. The technique presented adds to the field of measuring cell-generated stresses by providing the capability of measuring 3D stresses locally around a single cell and using physiologically relevant materials properties for analysis. The highest strains were observed in the most compliant matrix. Additionally, the stresses fluctuated over time due to the cells' interaction with the collagen matrix.


Assuntos
Colágeno , Glândulas Mamárias Animais/citologia , Alicerces Teciduais/química , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/metabolismo , Linhagem Celular , Células , Colágeno/química , Colágeno/metabolismo , Células Epiteliais/citologia , Matriz Extracelular/química , Matriz Extracelular/metabolismo , Feminino , Géis/química , Géis/metabolismo , Fenômenos Mecânicos , Camundongos , Engenharia Tecidual/métodos
7.
Biomed Mater Eng ; 20(6): 361-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21263182

RESUMO

Collagen is a key structural component of extracellular matrix and its mechanical properties, particularly its stiffness, have been shown to influence cell function. This study explores the mechanical behavior of type I collagen gels at low rates relevant to that of cell motion. The Young's modulus, E, was obtained for collagen samples of concentrations 1.3, 2 and 3 mg/ml at varying crosshead displacement rates: 0.01, 0.1 and 1 mm/min. Local strain measurement in the gage section were used for both the strain and strain rate determination. The power law models for the modulus at these low strain rates show that the values converge as the displacement rate approaches a quasistatic state. This study provides data that was unavailable in the past on the Young's modulus of collagen at rates relevant to the cell.


Assuntos
Colágeno/fisiologia , Módulo de Elasticidade/fisiologia , Movimento/fisiologia , Animais , Colágeno/química , Cães , Teste de Materiais , Modelos Biológicos , Modelos Teóricos , Concentração Osmolar , Ratos , Estresse Mecânico , Resistência à Tração/fisiologia , Fatores de Tempo , Alicerces Teciduais/química
8.
Biomaterials ; 24(22): 3931-9, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12834588

RESUMO

The understanding of corrosion behavior in NiTi is critical for the devices using this shape-memory alloy. In order to improve the surface properties of NiTi such as corrosion resistance, plasma source ion implantation (PSII) technique was employed with oxygen as incident ions at three levels of implantation dose (5x10(16), 1x10(17) and 3x10(17) ions/cm(-2)). Pitting corrosion and wear-corrosion behavior of control and PSII-modified Ti-50.7at% Ni alloy were evaluated by cyclic potentiodynamic polarization and wear-corrosion measurements. Surface characterization was used to interpret the different corrosion behavior observed between control and oxygen-implanted samples. Results showed that corrosion behavior was influenced by both heat treatment and surface modification. The best pitting corrosion resistance was observed for samples with Af=21 degrees C modified by oxygen implantation at a dose of 1x10(17) ions/cm(-2). Better wear-corrosion resistance was observed for oxygen-implanted samples.


Assuntos
Materiais Biocompatíveis , Níquel/química , Titânio/química , Corrosão , Concentração de Íons de Hidrogênio , Íons , Microscopia Eletrônica de Varredura , Oxigênio/química , Oxigênio/metabolismo , Propriedades de Superfície , Temperatura , Resistência à Tração
9.
J Mater Sci Mater Med ; 13(5): 501-8, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-15348604

RESUMO

A combination of shape memory characteristics, pseudoelasticity, and good damping properties make near-equiatomic nickel-titanium (Ni-Ti) alloy a desirable candidate material for certain biomedical device applications. The alloy has moderately good wear resistance, however, further improvements in this regard would be beneficial from the perspective of reducing wear debris generation, improving biocompatibility, and preventing failure during service. Fretting wear tests of Ni-Ti in both austenitic and martensitic microstructural conditions were performed with the goal of simulating wear which medical devices such as stents may experience during surgical implantation or service. The tests were performed using a stainless steel stylus counter-wearing surface under dry conditions and also with artificial plasma containing 80 g/L albumen protein as lubricant. Additionally, the research explores the feasibility of surface modification by sequential ion implantation with argon and oxygen to enhance the wear characteristics of the Ni-Ti alloy. Each of these implantations was performed to a dose of 3 x 10(17) atom/cm(2) and an energy of 50 kV, using the plasma source ion implantation process. Improvements in wear resistance were observed for the austenitic samples implanted with argon and oxygen. Ion implantation with argon also reduced the surface Ni content with respect to Ti due to differential sputtering rates of the two elements, an effect that points toward improved biocompatibility.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA