Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 67(20)2022 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-36126657

RESUMO

Objective. To develop a robust technique for calculating regional volume changes within the lung from x-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT).Approach. This technique is based on the change in transmitted x-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue.Main results. Lung air volumes calculated from x-ray intensity changes showed a strong correlation (R2= 0.98) against the true volumes, measured from high-resolution CT. This correlation enables us to accurately convert projected intensity data into relative changes in lung air volume. We have applied this technique to measure changes in regional lung volumes from x-ray image sequences of mechanically ventilated, recently-deceased newborn rabbits, without the use of CT.Significance. This method is suitable for biomedical research studies,enabling quantitative regional measurement of relative lung air volumes at high temporal resolution, and shows great potential for future clinical application.


Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Animais , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar/métodos , Coelhos , Radiografia , Tomografia Computadorizada por Raios X/métodos , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...