Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Stem Cell Res Ther ; 7(1): 145, 2016 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-27680210

RESUMO

BACKGROUND: Mesenchymal stem cells derived from human umbilical cord tissue, termed UCX®, have the potential to promote a full range of events leading to tissue regeneration and homeostasis. The main goal of this work was to investigate UCX® action in experimentally induced hindlimb ischemia (HLI). METHODS: UCX®, obtained by using a proprietary technology developed by ECBio (Amadora, Portugal), were delivered via intramuscular injection to C57BL/6 females after unilateral HLI induction. Perfusion recovery, capillary and collateral density increase were evaluated by laser doppler, CD31 immunohistochemistry and diaphonisation, respectively. The activation state of endothelial cells (ECs) was analysed after EC isolation by laser capture microdissection microscopy followed by RNA extraction, cDNA synthesis and quantitative RT-PCR analysis. The UCX®-conditioned medium was analysed on Gallios flow cytometer. The capacity of UCX® in promoting tubulogenesis and EC migration was assessed by matrigel tubule formation and wound-healing assay, respectively. RESULTS: We demonstrated that UCX® enhance angiogenesis in vitro via a paracrine effect. Importantly, after HLI induction, UCX® improve blood perfusion by stimulating angiogenesis and arteriogenesis. This is achieved through a new mechanism in which durable and simultaneous upregulation of transforming growth factor ß2, angiopoietin 2, fibroblast growth factor 2, and hepatocyte growth factor, in endothelial cells is induced by UCX®. CONCLUSIONS: In conclusion, our data demonstrate that UCX® improve the angiogenic potency of endothelial cells in the murine ischemic limb suggesting the potential of UCX® as a new therapeutic tool for critical limb ischemia.

2.
Am J Vet Res ; 67(11): 1908-13, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17078754

RESUMO

OBJECTIVE: To establish optimal conditions for long-term culture of the erythrocytic stage of Theileria uilenbergi. SAMPLE POPULATION: Red blood cells from 3 splenectomized sheep experimentally infected with a blood stabilate of T uilenbergi. PROCEDURES: Cultures of T uilenbergi were initiated by use of blood from experimentally infected sheep collected when parasites were detected in Giemsa-stained thin blood smears. Different culture conditions were tested to optimize in vitro growth of the organisms. Subcultures were performed at a ratio of 1:2, 1:4, and 1:8 when the percentage of parasitized erythrocytes (PPE) was at least 1% or when the initial PPE was doubled. RESULTS: The optimal culture medium was HL-1 medium (a complete chemically defined medium) supplemented with 20% sheep serum and 0.75% chemically defined lipids. Optimal culture conditions included incubation in a humidified 2% O(2), 5% CO(2), and 93% N(2) atmosphere at 37 degrees C. Cultures of the merozoite stage of the parasite were continuously propagated in vitro for > 1 year. The PPE reached values of up to 3%. CONCLUSIONS AND CLINICAL RELEVANCE: Optimization of culture conditions to reach a high PPE seems worthwhile. The continuous propagation of T uilenbergi in culture allows the production of parasite material without infecting animals and provides a continuous laboratory source of parasites for further studies.


Assuntos
Técnicas de Cultura de Células , Doenças dos Ovinos/parasitologia , Theileria/crescimento & desenvolvimento , Theileriose/parasitologia , Animais , Criopreservação/veterinária , Meios de Cultura Livres de Soro , Primers do DNA , Eritrócitos/parasitologia , Reação em Cadeia da Polimerase/veterinária , Ovinos , Doenças dos Ovinos/sangue , Theileriose/sangue
3.
Prep Biochem Biotechnol ; 36(4): 333-53, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16971304

RESUMO

A spherical porous glass support Trisoperl (TRISO) with four pore diameters (ø 47.8; 55.9; 102.6, and 108.8 nm) was characterized and selected for application in an optical flow cell immunosensor, in comparison with controlled pore glass (CPG). The TRISO support was functionalized with aldehyde and isothiocyanate (-NCS) groups to attach bovine serum albumin and alkaline phosphatase (AP). The TRISO isothiocyanate pore diameter 47.8 nm (TRISO(-NCS) 47.8 nm) showed the better potential to be used in the immunosensor. It immobilized more protein (19.3 mg AP per g support) while presenting an optical performance comparable to the CPG. CPG(-NCS) and TRISO(-NCS) 47.8 nm were tested in the immunosensor model where the saturation of the Goat IgG immobilized in the supports with Monoclonal Anti-Goat IgG conjugated with Cyanine-5 was reached, followed by regeneration with the elution buffer modified PBS pH 2.0. The TRISO(-NCS) 47.8 nm presented lower fluorescence intensity at saturation (around 39 AU) than CPG(-NCS) (150 to 104 AU), but revealed a major advantage related to the uniform arrangement of the spherical particles in the flow cell, generating no significant fluorescence differences between gravity and flow package.


Assuntos
Fosfatase Alcalina/química , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Enzimas Imobilizadas/química , Vidro/química , Aldeídos/química , Animais , Anticorpos Monoclonais , Carbocianinas/análise , Bovinos , Corantes Fluorescentes/análise , Imunoglobulina G/química , Isotiocianatos/química , Óptica e Fotônica , Soroalbumina Bovina/química , Propriedades de Superfície
4.
Parasitol Res ; 88(13 Suppl 1): S4-7, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12051607

RESUMO

Immunosensors can play an important role in the improvement of veterinary diagnostics in areas such as the diagnosis of diseases, drug detection and food quality control, by providing applications with rapid detection, high sensitivity and specificity. Associated with advances in biochemistry, biotechnology, electronics and microfabrication, new transduction devices that translate a biological interaction into an electrical signal have been developed. An overview of the current immunoassay techniques used in standard diagnosis is presented. This includes a brief description of the different immunosensor transducer principles and some examples of present and future developments.


Assuntos
Doenças dos Animais/diagnóstico , Técnicas Biossensoriais , Medicina Veterinária/métodos , Animais , Imunoensaio/instrumentação , Imunoensaio/métodos
5.
Biosens Bioelectron ; 17(1-2): 45-52, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11742734

RESUMO

The increasing concentration of nitrite in groundwater, rivers and lakes brings serious risks to the public health and to the environment. The aim of this work was the development of an optical biosensor for quantifying nitrite based on the activity of cytochrome cd(1) nitrite reductase immobilised in controlled pore glass (CPG) beads. The developed biosensor operates by measuring the optical reflectance of nitrite reductase, which shows spectroscopic changes when nitrite reversibly binds to the reduced form and oxidizes the enzyme. The optimisation of the immobilisation procedure showed that the immobilisation efficiency is highly dependent on the pH, being very low at basic pH, and that the maximum capacity of the CPG for the immobilisation of cd(1) was estimated in 57+/-10 mg cd(1)/g CPG. The CPG/cd(1) specific activity remained stable at 4 degrees C, decreasing only 10% in 15 days. No observed effects of the immobilisation on the enzyme characteristics were detected, regarding both the red/ox absorbance spectra and the enzyme specific activity, since the red/ox spectra are in good agreement with similar ones obtained for cd(1) in solution, and the specific activity at time zero (0.6 micromoles of NO(2)(-) reduced min(-1) mg of protein(-1)) is similar to that found for the soluble enzyme. The biosensor shows a sensitive response to increasing concentrations of nitrite in solution, especially at 460 nm, at which it showed higher sensitivity. The corresponding detection limit of 0.93 microM is well below the maximum admissible concentration imposed by European Community norms, of 2.2 microM.


Assuntos
Técnicas Biossensoriais/métodos , Enzimas Imobilizadas/metabolismo , Nitrito Redutases/metabolismo , Nitritos/análise , Concentração de Íons de Hidrogênio , Temperatura , Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...