Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 21(1): 87-94, 2005 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-15967355

RESUMO

This report describes technical improvements to the manufacture of a carbon fibre electrode for the stable and sensitive detection of H2O2 (detection limit at 0.5 microM). This electrode was also modified through the co-immobilisation of acetylcholinesterase (AChE) and/or choline oxidase (ChOx) in a bovine serum albumin (BSA) membrane for the development of a sensor for in vivo measurements of acetylcholine and choline. Amperometric measurements were performed using a conventional three-electrode system forming part of a flow-injection set-up at an applied potential of 800-1100 mV relative to an Ag/AgCl reference electrode. The optimised biosensor obtained was reproducible and stable, and exhibited a detection limit of 1 microM for both acetylcholine and choline. However, due to the high operating potential used, the biosensor was prone to substantial interference from other electroactive compounds, such as ascorbic acid. Therefore, in a further step, a mediated electron transfer approach was used that incorporated horseradish peroxidase into an osmium-based redox hydrogel layered onto the active surface of the electrode. Afterwards, a Nafion layer and a coating containing AChE and/or ChOx co-immobilised in a BSA membrane were successively deposited. This procedure further increased the selectivity of the biosensor, when operated in the same flow-injection system but at an applied potential of -50 mV relative to an Ag/AgCl reference electrode. The sensor exhibited good selectivity and a high sensitivity over a concentration range (0.3-100 microM) suitable for the measurement of choline and acetylcholine in vivo.


Assuntos
Acetilcolina/análise , Técnicas Biossensoriais/instrumentação , Carbono , Colina/análise , Acetilcolinesterase , Oxirredutases do Álcool , Química Encefálica , Fibra de Carbono , Peroxidase do Rábano Silvestre , Humanos , Microeletrodos
2.
Ukr Biokhim Zh (1999) ; 77(3): 146-54, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16566143

RESUMO

A new enzymo-chemical method for the simultaneous assay of methanol and formaldehyde in mixtures is described which exploits alcohol oxidase (AO) and aldehyde-selective reagent, 3-methyl-2-benzothiazolinone hydrazone (MBTH). The enzyme is used for methanol oxidation to formaldehyde and MBTH plays a double role: 1) at the first step of reaction, it forms a colorless azine adduct with pre-existing and enzymatically formed formaldehyde and masks it from oxidation by AO; 2) at the second step of reaction, non-enzymatic oxidation of azine product to cyanine dye occurs in the presence of ferric ions in acid medium. Pre-existing formaldehyde content is assayed by colorimetric reaction with MBTH without treating samples by AO, and methanol content is determined by a gain in a colored product due to methanol-oxidising reaction. Possibility of differential assay of methanol and formaldehyde by the proposed method has been proved for model solutions as well as for real samples of industrial waste and technical formaline. A threshold sensitivity of the assay method for both analytes is near 1 microM that responds to 30-32 ng analyte in 1 ml of reaction mixture and is 3.2-fold higher when compared to the chemical method with the use of permanganate and chromotropic acid. Linearity of the calibration curve is reliable (p < 0.0001) and standard deviation for parallel measurements for real samples does not exceed 7%. The proposed method, in contrast to the standard chemical approach, does not need the use of aggressive chemicals (concentrated sulfuric, phosphoric, chromotropic acids, permanganate), it is more simple in fulfillment and can be used for industrial wastes control and certification of formaline-contained stuffs.


Assuntos
Oxirredutases do Álcool/química , Poluentes Ambientais/análise , Formaldeído/análise , Metanol/análise , Benzotiazóis , Calibragem , Cromatografia Gasosa , Colorimetria/métodos , Enzimas Imobilizadas/química , Hidrazonas , Indicadores e Reagentes , Estrutura Molecular , Naftalenossulfonatos/química , Oxirredução , Permanganato de Potássio/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tiazóis/química
3.
Biotechnol Lett ; 26(7): 559-62, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15168854

RESUMO

The lux-gene fused Ralstonia eutropha, when adapting to static conditions, causes stratification of air-exposed and nutrient-rich cultures at above 0.15 mg biomass ml(-1). The O2 respiring biofilm (luminous neuston) phase, along with the dark sub-neustonic suspension phase, develops within 5-60 min. The instability of the biphasic static culture was identified as a reason for occasionally observable oscillatory bioluminescence.


Assuntos
Relógios Biológicos/fisiologia , Técnicas de Cultura de Células/métodos , Cupriavidus necator/fisiologia , Medições Luminescentes , Proteínas Luminescentes/metabolismo , Oxigênio/metabolismo , Adaptação Fisiológica/fisiologia , Homeostase/fisiologia , Proteínas Luminescentes/genética , Proteínas Recombinantes/metabolismo
4.
Biosens Bioelectron ; 16(9-12): 611-20, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11679236

RESUMO

An affinity-assay was developed that is based on the modulation of the diffusion coefficient of a redox-labelled hapten upon complementary recognition of the analyte leading to an increase of molecular weight and hence to a decrease of the diffusion coefficient. The slower diffusion is monitored by means of cyclic voltammetry. In order to demonstrate the feasibility of this assay format, recognition of biotin by streptavidin has been chosen as a model system. Labelling of biotin was achieved by covalent binding of a ferrocene derivative to the biotin unit. To reduce the consumption of expensive compounds and to allow automatisation of the assay a novel miniaturised set-up was developed based on a wall-free sample droplet which forms the electrochemical cell with typical volumes of up to 10 microl. This droplet is dispensed by means of a step-motor driven syringe pump through a specially designed electrode holder spanning the gap between a micro-working electrode and a macroscopic counter electrode. By means of a piezo-driven micro-dispenser a predefined number of nano-droplets (100 pl volume each) containing the redox-labelled hapten are shot into the sample droplet. By this, any physical contact and hence any cross-contamination between the sample and the reagent solution could be avoided. Signal amplification can be achieved by redox recycling between the micro-electrode and the perpendicular positioned macroscopic counter electrode.


Assuntos
Técnicas Biossensoriais/instrumentação , Biotina , Eletroquímica , Desenho de Equipamento , Haptenos , Imunoensaio/instrumentação , Imunoensaio/métodos , Miniaturização , Oxirredução , Estreptavidina
5.
Biosens Bioelectron ; 16(9-12): 765-71, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11679254

RESUMO

A bienzyme flow injection system is presented for the monitoring of alpha-ketoglutarate produced in a fermentation process, using glutamate dehydrogenase (GDH) and glutamate oxidase (GlOx) immobilised in two serially connected expanded bed reactors. The use of expanded bed resulted in unhindered passage of the bacterial cells through the columns, and thereby the need of a separate filtering step (e.g. microdialysis) was avoided. In the first reactor, alpha-ketoglutarate was converted to L-glutamate by GDH in the presence of ammonia and NADH. In the following reactor, L-glutamate was converted by GlOx to alpha-ketoglutarate, ammonia and hydrogen peroxide, which was detected in an electrochemical flow-through cell at +650 mV vs. Pt/(0.1 M KCl). The detection limit of alpha-ketoglutarate in the coupled packed bed reactors was 1 microM (defined as 3 S/N), the linear range 0-100 microM, and the sensitivity 0.80 nA/microM (R(2) 0.99). In the coupled expanded bed reactors, the detection limit of alpha-ketoglutarate was 7 microM (defined as 3 S/N), the linear range and the sensitivity being 0-500 microM and 0.11 nA/microM (R(2) 1.00), respectively. The response time (defined as the time between peak rise and return to baseline) was 5 min for coupled packed beds (injection of supernatant), and 12 min for coupled expanded beds (injection of sample containing cellular and particulate matter). Several other parameters, such as reactor stability, flow rate dependency, bed expansion, glutamate interference, etc. were investigated and characterised. When analysing real samples from a fermentation broth, the same results were obtained independent of the nature of the reactor system (packed or expanded bed). The hereby described system can easily be automatised and controlled from a personal computer.


Assuntos
Reatores Biológicos , Técnicas Biossensoriais/instrumentação , Ácidos Cetoglutáricos/análise , Aminoácido Oxirredutases , Enzimas Imobilizadas , Fermentação , Análise de Injeção de Fluxo , Glutamato Desidrogenase , Ácidos Cetoglutáricos/metabolismo
6.
Biosens Bioelectron ; 16(9-12): 827-37, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11679261

RESUMO

We are reporting on a novel approach for structured immobilisation of enzymes on gold surfaces modified with monolayers of functionalised alkylthiols. The formation of enzyme spots is achieved by shooting very small volumes of an appropriate enzyme solution (down to 100 pl) onto a thiol-monolayer modified gold surface using a micro-dispenser. Formation of enzyme patterns is obtained by moving the micro-dispenser relative to the modified gold surface using a micro-positioning device. Enzyme spots with typical lateral dimensions of 100 microm are obtained, but also, more complex structures, e.g. lines or meander structures, can be achieved by multiple droplets dispensed during the concomitant movement of the micro-dispenser. The first enzyme layer on top of the functionalised thiol-monolayer is subsequently covalently immobilised using either carbodiimide activation of carboxilic headgroups at the enzyme or via already introduced activated ester functions at the monolayer. Immobilised enzyme activities of glucose oxidase and lactate oxidase patterns have been characterised by means of scanning electrochemical microscopy. The product of the enzyme-catalysed reaction, H(2)O(2), is detected with an micro-electrode in the presence of either or both substrates, glucose and lactate, leading to a visualisation of the corresponding enzyme pattern and the lateral enzymatic activity.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Eletroquímica , Enzimas Imobilizadas , Glucose Oxidase , Ouro , Peróxido de Hidrogênio/análise , Microscopia/métodos , Miniaturização , Oxigenases de Função Mista , Propriedades de Superfície
7.
Anal Chem ; 73(17): 4254-61, 2001 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-11569817

RESUMO

Micrometer-sized enzyme grids were fabricated on gold surfaces using a novel method based on a flow-through microdispenser. The method involves dispensing very small droplets of enzyme solution (approximately 100 pL) during the concomitant relative movement of a gold substrate with respect to the nozzle of a microdispenser, resulting in enzyme patterns with a line width of approximately 100 microm. Different immobilization methods have been evaluated, yielding either enzyme monolayers using functionalized self-assembled thiol monolayers for covalent binding of the enzyme or enzyme multilayers by cross-linking or entrapping the enzymes in a polymer film. The latter immobilization techniques allow the formation of coupled multienzyme structures. On the basis of this feature, coupled bienzyme (glucose oxidase and catalase) or three-enzyme (alpha-glucosidase, mutarotase, and glucose oxidase) microstructures consisting of line patterns of one enzyme intersecting with the patterned lines of the other enzyme(s) were fabricated. By means of scanning electrochemical microscopy (SECM) operated in the generator-collector mode, the enzyme microstructures and their integrity were visualized using the localized detection of enzymatically produced/consumed H2O2. A calibration curve for glucose could be obtained by subsequent SECM line scans over a glucose oxidase microstructure for increasing glucose concentrations, demonstrating the possibility of obtaining localized quantitative data from the prepared microstructures. Possible applications of these enzyme microstructures for multianalyte detection and interference elimination and for screening of different biosensor configurations are highlighted.


Assuntos
Técnicas Biossensoriais/instrumentação , Enzimas Imobilizadas/química , Ouro , Proteínas/química
9.
Anal Chem ; 73(11): 2468-75, 2001 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-11403287

RESUMO

Two novel methods for the determination of diffusion coefficients of redox species combining the special properties of microdispensing devices and microelectrodes are presented. Both are based on the local application of tiny volumes of the redox-active species by means of a dispenser nozzle at a defined distance from the surface of a microelectrode. The microelectrode, which is inserted through the bottom into an electrochemical cell, is held at a constant potential sufficient to oxidize or reduce the electro-active species under diffusional control. The dispenser, which is filled with the electro-active species, can be positioned by means of micrometer screws over the microelectrode. After dispensing a defined number of droplets near the microelectrode surface, the current through the microelectrode is recorded, usually yielding a peak-shaped curve having a defined time delay between the shooting of the droplets and the maximum current. The time that is necessary to attain maximum current, together with the known distance between two dispensing points, can be used to determine the diffusion coefficient of the electroactive species without knowledge of any system parameters, such as concentration of the redox species, diameter of the electroactive surface or number of transferred electrons. A similar method for the determination of diffusion coefficient of redox species involves a second redox species for calibration purposes. A mixture of both species is shot close to the microelectrode surface. Due to the different formal potentials of the redox species that are used, they can be distinguished in sequential experiments by variation of the potentials that are applied to the microelectrode, and it is thus possible to determine the individual transit times of the redox species independently. The difference in the transit times, together with the known diffusion coefficient of one of the redox species, can be used to calculate the unknown diffusion coefficient of the second one.

10.
J Inorg Biochem ; 79(1-4): 225-9, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10830870

RESUMO

We have expressed and purified metal-resistance and metal regulatory proteins from the bacterial determinants of resistance to heavy metals and utilised these in the development of biosensors for heavy metals. Both the metallothionein from the cyanobacterium Synechococcus PCC 7942 and the MerR regulatory protein from transposon Tn501 allow the detection of non-specific metal binding down to 10(-15) M concentrations of Hg(II), Cu(II), Zn(II) and Cd(II) in pure solution. Differential effects of the metals can be detected at both low and high concentrations, and the shape of the capacitance curves may reflect biologically relevant responses of the proteins to metals. Further work is required to establish the relationship between the detected binding of metal and the biological response of the protein, or to provide biosensors of use in the natural environment.


Assuntos
Proteínas de Bactérias/metabolismo , Técnicas Biossensoriais , Cianobactérias/metabolismo , Proteínas de Ligação a DNA/metabolismo , Metalotioneína/metabolismo , Metais Pesados/análise , Metais Pesados/metabolismo , Proteínas de Bactérias/genética , Disponibilidade Biológica , Cádmio/análise , Cádmio/metabolismo , Cobre/análise , Cobre/metabolismo , Cianobactérias/genética , Elementos de DNA Transponíveis , Proteínas de Ligação a DNA/genética , Resistência Microbiana a Medicamentos , Mercúrio/análise , Mercúrio/metabolismo , Metalotioneína/genética , Metais Pesados/farmacologia , Proteínas Recombinantes/metabolismo , Zinco/análise , Zinco/metabolismo
11.
Anal Chem ; 72(7): 1591-7, 2000 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-10763257

RESUMO

This work presents the design and optimization of amperometric biosensors for the determination of biogenic amines (e.g., histamine, putrescine, cadaverine, tyramine, cystamine, agmatine, spermidine), commonly present in food products, and their application for monitoring of freshness in fish samples. The biosensors were used as the working electrodes of a three-electrode electrochemical cell of wall-jet type, operated at -50 mV vs Ag/AgCl, in a flow injection system. Two different bienzyme electrode designs were considered, one based on the two enzymes [a newly isolated and purified amine oxidase (AO) and horseradish peroxidase (HRP)] simply adsorbed onto graphite electrodes, and one when they were cross-linked to an Os-based redox polymer. The redox hydrogel-based biosensors showed better biosensors characteristics, i.e., sensitivity of 0.194 A M-1 cm-2 for putrescine and 0.073 A M-1 cm-2 for histamine, and detection limits (calculated as three times the signal-to-noise ratio) of 0.17 microM for putrescine and 0.33 microM for histamine. The optimized redox hydrogel-based biosensors were evaluated in terms of stability and selectivity, and were used for the determination of total amine content in fish samples kept for 10 days in different conditions.

12.
Anal Chem ; 72(24): 5988-93, 2000 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-11140767

RESUMO

Amine oxidase (AO, EC. 1.4.3.6) was previously shown to be a very efficient biological recognition element of amperometric biosensors for monitoring biogenic amines. The enzyme was effectively working in both mono- and bienzyme electrode designs, based on either a direct or a mediated electron-transfer pathway. This work focuses on the elucidation of the electron-transfer mechanism of the monoenzymatic unmediated AO-modified biosensor. The observed unmediated catalytic currents were assumed to be caused by (i) a direct electron-transfer process, (ii) the electrooxidation of the formed product, or (iii) their combination. Experiments supporting these assumptions are discussed in detail.


Assuntos
Amina Oxidase (contendo Cobre)/metabolismo , Monoaminas Biogênicas/metabolismo , Eletrodos , Amina Oxidase (contendo Cobre)/química , Monoaminas Biogênicas/química , Catálise , Oxirredução
13.
Biosens Bioelectron ; 15(9-10): 491-7, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11419644

RESUMO

Native horseradish peroxidase (HRP) on graphite has revealed approximately 50% of the active enzyme molecules to be in direct electron transfer (ET) contact with the electrode surface. Some novel plant peroxidases from tobacco, peanut and sweet potato were kinetically characterised on graphite in order to find promising candidates for biosensor applications and to understand the nature of the direct ET in the case of plant peroxidases. From measurements of the mediated and mediatorless currents of hydrogen peroxide reduction at the peroxidase-modified rotating disk electrodes (RDE), it was concluded that the fraction of enzyme molecules in direct ET varies substantially for the different plant peroxidases. It was observed that the anionic peroxidases (from sweet potato and tobacco) demonstrated a higher percentage of molecules in direct ET than the cationic ones (HRP and peanut peroxidase). The peroxidases with a high degree of glycosylation demonstrated a lower percentage of molecules in direct ET. It could, thus, be concluded that glycosylation of the peroxidases hinders direct ET and that a net negative charge on the peroxidase (low pI value) is beneficial for direct ET. Especially noticeable are the values obtained for sweet potato peroxidase (SPP), revealing both a high percentage in direct ET and a high rate constant of direct ET. The peroxidase electrodes were used for determination of hydrogen peroxide in RDE mode (mediatorless). SPP gave the lowest detection limit (40 nM) followed by HRP and peanut peroxidase.


Assuntos
Técnicas Biossensoriais/métodos , Peroxidases , Arachis/enzimologia , Eletroquímica , Transporte de Elétrons , Peroxidase do Rábano Silvestre/metabolismo , Cinética , Peroxidases/metabolismo , Solanaceae/enzimologia
14.
Anal Chem ; 71(16): 3581-6, 1999 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-10464483

RESUMO

It is reported for the first time that direct electron-transfer processes between a polypyrrole (PPY) entrapped quinohemoprotein alcohol dehydrogenase from Gluconobacter sp. 33 (QH-ADH) and a platinum electrode take place via the conducting-polymer network. The cooperative action of the enzyme-integrated prosthetic groups--pyrroloquinoline-quinone and hemes--is assumed to allow this electron-transfer pathway from the enzyme's active site to the conducting-polymer backbone. A hypothetical model of the electron transfer is proposed which is supported by the influence of various parameters, such as, e.g., ionic strength and nature of the buffer salts. This unusual electron-transfer pathway leads to an accentuated increase of the K M app value (102 mM) and hence to a significantly increased linear detection range of an ethanol sensor based on this enzyme.


Assuntos
Oxirredutases do Álcool , Polímeros , Pirróis , Acetobacteraceae/enzimologia , Transporte de Elétrons , Etanol , Modelos Químicos , Modelos Moleculares , Platina , Espectrofotometria Ultravioleta
15.
J Pharm Biomed Anal ; 19(1-2): 93-105, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10698571

RESUMO

Amperometric bienzyme electrodes based on coupled L-glutamate oxidase (GlOx) and horseradish peroxidase (HRP) were constructed for the direct monitoring of L-glutamate in a flow injection (FI)-system. The bienzyme electrodes were constructed by coating solid graphite rods with a premixed solution containing GlOx and HRP crosslinked with a redox polymer formed of poly(1-vinylimidazole) complexed with (osmium (4-4'-dimethylbpy)2 Cl)II/III. Poly(ethylene glycol) diglycidyl ether (PEGDGE) was used as the crosslinker and the modified electrodes were inserted as the working electrode in a conventional three electrode flow through amperometric cell operated at -0.05 V versus Ag¿AgCl (0.1 M KCl). The bienzyme electrode was optimized with regard to wire composition, Os-loading of the wires, enzyme ratios, coating procedure, flow rate, effect of poly(ethyleneimine) addition, etc. The optimized electrodes were characterized by a sensitivity of 88.36 +/- 0.14 microA mM(-1) cm(-2), a detection limit of 0.3 microM (calculated as three times the signal-to-noise ratio), a response time of less than 10 s and responded linearly between 0.3 and 250 microM (linear regression coefficient = 0.999) with an operational stability of only 3% sensitivity loss during 8 h of continuous FI operation at a sample throughput of 30 injections h(-1).


Assuntos
Aminoácido Oxirredutases , Técnicas Biossensoriais , Ácido Glutâmico/análise , Grafite , Peroxidase do Rábano Silvestre , Hidrogel de Polietilenoglicol-Dimetacrilato , Indicadores e Reagentes , Microeletrodos , Neurônios/química , Oxirredução , Potenciometria
16.
Anal Chem ; 70(19): 4162-9, 1998 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-9784752

RESUMO

Sensors based on proteins (GST-SmtA and MerR) with distinct binding sites for heavy metal ions were developed and characterized. A capacitive signal transducer was used to measure the conformational change following binding. The proteins were overexpressed in Escherichia coli, purified, and immobilized in different ways to a self-assembled thiol layer on a gold electrode placed as the working electrode in a potentiostatic arrangement in a flow analysis system. The selectivity and the sensitivity of the two protein-based biosensors were measured and compared for copper, cadmium, mercury, and zinc ions. The GST-SmtA electrodes displayed a broader selectivity (sensing all four heavy metal ions) compared with the MerR-based ones, which showed an accentuated selectivity for mercury ions. Metal ions could be detected with both electrode types down to femtomolar concentration. The upper measuring limits, presumably due to near saturation of the proteins' binding sites, were around 10(-10) M. Control electrodes similarly constructed but based on bovine serum albumin or urease did not yield any signals. The electrodes could be regenerated with EDTA and used for more than 2 weeks with about 40% reduction in sensitivity.


Assuntos
Técnicas Biossensoriais/métodos , Metais Pesados/análise , Sequência de Aminoácidos , Técnicas Biossensoriais/instrumentação , Eletrodos , Desenho de Equipamento , Escherichia coli/genética , Escherichia coli/metabolismo , Metais Pesados/química , Dados de Sequência Molecular , Potenciometria/métodos , Biossíntese de Proteínas
17.
Anal Chem ; 70(13): 2596-600, 1998 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-9666727

RESUMO

An amperometric flow system combined with a glucose oxidase-mutarotase reactor was optimized and used to determine aromatic amines and phenols using peroxidase-modified graphite electrodes. An increase in currents upon injection of the analyzed substrate was shown to be approximated by a Michaelis-Menten type dependence. The detection limit was calculated as 3 times the noise, and the sensitivity was calculated as Imax/K(m)app. Commercially available horseradish peroxidase was compared with tobacco anionic and peanut cationic peroxidases for determination of aromatic amines and phenols. Detection limits of 10 nM for determination of o-aminophenol and o- and p-phenylenediamine achieved with a tobacco peroxidase-modified electrode give a promise for further improvements in sensitivities and detection limits of biosensors.


Assuntos
Compostos de Anilina/análise , Técnicas Biossensoriais , Fenóis/análise , Animais , Arachis/enzimologia , Aspergillus niger/enzimologia , Carboidratos Epimerases , Análise de Injeção de Fluxo , Glucose Oxidase , Peroxidase do Rábano Silvestre , Rim/enzimologia , Plantas Geneticamente Modificadas , Plantas Tóxicas , Estereoisomerismo , Suínos , Nicotiana/enzimologia
19.
Anal Chem ; 69(19): 4039-44, 1997 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21639213

RESUMO

Enzyme electrodes for the determination of sugars based on solid graphite electrodes modified with oligosaccharide dehydrogenase "wired" with an osmium-based one-electron (no proton) acceptor redox hydrogel were studied as sensors in a flow injection system. The enzyme and a poly(1-vinylimidazole) (PVI) where every tenth mer is complexed with osmium (4,4'-dimethylbpy)(2)Cl, (denoted PVI(10)dmeOs) were cross-linked with poly(ethylene glycol) (diglycidyl) ether. The electrodes were active for l-arabinose, d-xylose, d-galactose, d-fructose, d-glucose, d-mannose, cellobiose, lactose, maltose, and maltooligosaccharides up to a degree of polymerization of 7. The highest relative response found was for glucose (100%) followed by maltose (40.6%) and lactose (40.6%). Fructose and isomaltotriose gave the lowest responses (<1%). Calibration curves for glucose were strictly linear in the range between 30 and 500 µM with sensitivity and apparent Michaelis-Menten constant (K(m)(app)) of 23.0 ± 1.4 µA mM(-)(1)cm(-)(2) and 4.26 ± 0.95 mM, respectively.

20.
Anal Chem ; 69(17): 3471-5, 1997 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21639270

RESUMO

An analysis system is described for the determination of the neurotoxin ß-N-oxalyl-l-α,ß-diaminopropionic acid (ß-ODAP). The system is based on liquid chromatographic separation of ß-ODAP from interfering amino acids on an anion exchange column coupled with an amperometric enzyme electrode for the registration of ß-ODAP. The electrode is based on a graphite rod modified with an Os(2+/3+) redox polymer cross-linked with l-glutamate oxidase and horseradish peroxidase. This LC-bienzyme electrode analytical system enabled monitoring of as low as 4 µM ß-ODAP (injection volume 100 µL). The ß-ODAP content in real grass pea samples was measured to range between 3.3 and 5.2 g kg(-)(1) in dry grass pea.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA