1.
Lab Chip ; 22(17): 3147-3156, 2022 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-35678256

RESUMO

A microfluidic platform for the integration of multi-step biological assays has been developed. The presented system is a unique instrument compatible with microfluidic chips for various applications based on bead manipulation. Two examples of microfluidic cartridges are presented here. The first one contains two rows of eight chambers (40 and 80 µL), six reagent inlets, eight testing solution (calibrators and samples) inlets and eight outlets to reproduce precisely each step of a biological assay. This configuration is versatile enough to integrate many different biological assays and save a lot of development time. The second architecture is dedicated to one specific protocol and is completely automated from the standard and sample dilutions to the optical detection. Linear dilutions have been integrated to prepare automatically a range of standard concentrations and outlets have been modified for integrated colorimetric detection. The technology uses pneumatically collapsible chambers to perform all the fluidic operations for a fully automated protocol such as volume calibrations, fluid transport, mixing, and washing steps. A programmable instrument with a software interface has been developed to adapt rapidly a protocol to this cartridge. As an example, these new microfluidic cartridges have been used to successfully perform an immunoassay for gluten detection in the dynamic range of 10-30 ppm with good sensitivity (2 ppm) and specificity.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Glutens , Imunoensaio/métodos , Fenômenos Magnéticos , Microfluídica/métodos
2.
Biosensors (Basel) ; 12(5)2022 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-35624647

RESUMO

Loop-mediated isothermal amplification (LAMP) is an exponential amplification method of DNA strands that is more and more used for its high performances. Thanks to its high sensitivity and selectivity, LAMP found numerous applications from the detection of pathogens or viruses through their genome amplification to its incorporation as an amplification strategy in protein or miRNA biomarker quantification. The LAMP method is composed of two stages: the first one consists in the transformation of the DNA strands into dumbbell structures formed of two stems and loops thanks to four primers; then, in the second stage, only two primers are required to amplify the dumbbells exponentially in numerous hairpins of increasing lengths. In this paper, we propose a theoretical framework to analyze the kinetics of the second stage of LAMP, the isothermal dumbbell exponential amplification (IDEA) as function of the physico-chemical parameters of the amplification reaction. Dedicated experiments validate the models. We believe these results may help the optimization of LAMP performances by reducing the number of experiments necessary to find the best parameters.


Assuntos
Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , DNA , Cinética , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos
3.
Anal Chem ; 94(7): 3376-3385, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35143170

RESUMO

Detecting blood biomarkers such as proteins with high sensitivity and specificity is of the utmost importance for early and reliable disease diagnosis. As molecular probes, aptamers are raising increasing interest for biosensor applications as an alternative to antibodies, which are used in classical enzyme-linked immuno-sorbent assays (ELISA). We have developed a sensitive and antibody-free molecular quantification assay that combines the specificity of aptamers and the sensitivity of the loop-mediated isothermal amplification (LAMP). For the proof-of-concept, we consider two types of biomarkers: (i) a model of oligonucleotide mimicking nucleic acid targets and (ii) the thrombin involved in the complex coagulation cascade as a model protein for which two relevant aptamers form a stable sandwich. The assay protocol is based on a few successive steps, similar to sandwich ELISA. First, aptamer-coated magnetic beads are added to the sample to specifically capture the targets. Then, the sandwich complex is formed by adding the second aptamer. This secondary aptamer is integrated in a larger oligonucleotide dumbbell sequence designed for LAMP detection using only two primers. After a proper rinsing step, the isothermal dumbbell exponential amplification is performed to detect and quantify a low amount of targets (limit of detection ∼ 1 pM for the oligonucleotide and ∼100 pM for thrombin). This study demonstrates that our innovative aptamero-LAMP assay could be relevant for the detection of different types of biomarkers and their quantification at physiological levels. This may also pave the way for antibody-free molecular assays.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Anticorpos , Bioensaio , Técnicas Biossensoriais/métodos , Trombina/análise
4.
Anal Chem ; 93(2): 683-690, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33319979

RESUMO

Immunoassays have been used for decades in clinical laboratories to quantify proteins in serum and plasma samples. However, their limitations make them inappropriate in some cases. Recently, mass spectrometry (MS) based proteomics analysis has emerged as a promising alternative method when seeking to assess panels of protein biomarkers with a view to providing protein profiles to monitor health status. Up to now, however, translation of MS-based proteomics to the clinic has been hampered by its complexity and the substantial time and human resources necessary for sample preparation. Plasma matrix is particularly tricky to process as it contains more than 3000 proteins with concentrations spanning an extreme dynamic range (1010). To address this preanalytical challenge, we designed a microfluidic device (PepS) automating and accelerating blood sample preparation for bottom-up MS-based proteomics analysis. The microfluidic cartridge is operated through a dedicated compact instrument providing fully automated fluid processing and thermal control. In less than 2 h, the PepS device allows bedside plasma separation from whole blood, volume metering, depletion of albumin, protein digestion with trypsin, and stabilization of tryptic peptides on solid-phase extraction sorbent. For this first presentation, the performance of the PepS device was assessed using discovery proteomics and targeted proteomics, detecting a panel of three protein biomarkers routinely assayed in clinical laboratories (alanine aminotransferase 1, C-reactive protein, and myoglobin). This innovative microfluidic device and its associated instrumentation should help to streamline and simplify clinical proteomics studies.


Assuntos
Proteínas Sanguíneas/química , Proteômica/métodos , Biomarcadores , Humanos , Dispositivos Lab-On-A-Chip , Sistemas Automatizados de Assistência Junto ao Leito , Manejo de Espécimes
5.
J Pharm Biomed Anal ; 194: 113777, 2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33293175

RESUMO

Although cardiac pathologies are the major cause of death in the world, it remains difficult to provide a reliable diagnosis to prevent heart attacks. Rapid patient care and management in emergencies are critical to prevent dramatic consequences. Thus, relevant biomarkers such as cardiac troponin and natriuretic peptides are currently targeted by commercialized Point-Of-Care immunoassays. Key points still to be addressed concern cost, lack of standardization, and poor specificity, which could limit the reliability of the assays. Consequently, alternatives are emerging to address these issues. New probe molecules such as aptamers or molecularly imprinted polymers should allow a reduction in cost of the assays and an increase in reproducibility. In addition, the assay specificity and reliability could be improved by enabling multiplexing through the detection of several molecular targets in a single device.


Assuntos
Infarto do Miocárdio , Biomarcadores , Humanos , Imunoensaio , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes
6.
High Throughput ; 7(2)2018 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-29671804

RESUMO

Pre-transfusion bedside compatibility test is mandatory to check that the donor and the recipient present compatible groups before any transfusion is performed. Although blood typing devices are present on the market, they still suffer from various drawbacks, like results that are based on naked-eye observation or difficulties in blood handling and process automation. In this study, we addressed the development of a red blood cells (RBC) agglutination assay for point-of-care blood typing. An injection molded microfluidic chip that is designed to enhance capillary flow contained anti-A or anti-B dried reagents inside its microchannel. The only blood handling step in the assay protocol consisted in the deposit of a blood drop at the tip of the biochip, and imaging was then achieved. The embedded reagents were able to trigger RBC agglutination in situ, allowing for us to monitor in real time the whole process. An image processing algorithm was developed on diluted bloods to compute real-time agglutination indicator and was further validated on undiluted blood. Through this proof of concept, we achieved efficient, automated, real time, and quantitative measurement of agglutination inside a passive biochip for blood typing which could be further generalized to blood biomarker detection and quantification.

7.
Biosens Bioelectron ; 93: 110-117, 2017 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-27687224

RESUMO

The process of agglutination is commonly used for the detection of biomarkers like proteins or viruses. The multiple bindings between micrometer sized particles, either latex beads or red blood cells (RBCs), create aggregates that are easily detectable and give qualitative information about the presence of the biomarkers. In most cases, the detection is made by simple naked-eye observation of agglutinates without any access to the kinetics of agglutination. In this study, we address the development of a real-time time observation of RBCs agglutination. Using ABO blood typing as a proof-of-concept, we developed i) an integrated biological protocol suitable for further use as point-of-care (POC) analysis and ii) two dedicated image processing algorithms for the real-time and quantitative measurement of agglutination. Anti-A or anti-B typing reagents were dried inside the microchannel of a passive microfluidic chip designed to enhance capillary flow. A blood drop deposit at the tip of the biochip established a simple biological protocol. In situ agglutination of autologous RBCs was achieved by means of embedded reagents and real time agglutination process was monitored by video recording. Using a training set of 24 experiments, two real-time indicators based on correlation and variance of gray levels were optimized and then further confirmed on a validation set. 100% correct discrimination between positive and negative agglutinations was performed within less than 2min by measuring real-time evolution of both correlation and variance indicators.


Assuntos
Aglutinação/imunologia , Técnicas Biossensoriais , Tipagem e Reações Cruzadas Sanguíneas/métodos , Eritrócitos/imunologia , Anticorpos/química , Anticorpos/imunologia , Eritrócitos/química , Humanos , Microfluídica
8.
Proteomics Clin Appl ; 8(11-12): 982-93, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25290619

RESUMO

PURPOSE: Ovarian cancer is a devastating disease and biomarkers for its early diagnosis are urgently required. Serum may be a valuable source of biomarkers that may be revealed by proteomic profiling. Herein, complementary serum protein profiling strategies were employed for discovery of biomarkers that could discriminate cases of malignant and benign ovarian cancer. EXPERIMENTAL DESIGN: Identically collected and processed serum samples from 22 cases of invasive epithelial ovarian cancer, 45 benign ovarian neoplasms, and 64 healthy volunteers were subjected to immunodepletion and protein equalization coupled to 2D-DIGE/MS and multidimensional fractionation coupled to SELDI-TOF profiling with MS/MS for protein identification. Selected candidates were verified by ELISA in samples from malignant (n = 70) and benign (n = 89) cases and combined marker panels tested against serum CA125. RESULTS: Both profiling platforms were complementary in identifying biomarker candidates, four of which (A1AT, SLPI, APOA4, VDBP) significantly discriminated malignant from benign cases. However, no combination of markers was as good as CA125 for diagnostic accuracy. SLPI was further tested as an early marker using prediagnosis serum samples. While it rose in cases toward diagnosis, it did not discriminate prediagnosis cases from controls. CONCLUSIONS AND CLINICAL RELEVANCE: The candidate biomarkers warrant further validation in independent sample sets.


Assuntos
Biomarcadores Tumorais/metabolismo , Proteínas Sanguíneas/metabolismo , Neoplasias Ovarianas/metabolismo , Proteoma/metabolismo , Proteômica/métodos , Adulto , Idoso , Apolipoproteínas A/sangue , Apolipoproteínas A/metabolismo , Biomarcadores Tumorais/sangue , Eletroforese em Gel Bidimensional , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas/sangue , Neoplasias Ovarianas/diagnóstico , Reprodutibilidade dos Testes , Inibidor Secretado de Peptidases Leucocitárias/sangue , Inibidor Secretado de Peptidases Leucocitárias/metabolismo , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Espectrometria de Massas em Tandem
9.
Lab Chip ; 13(5): 901-9, 2013 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-23306307

RESUMO

On the road towards efficient diagnostics of infectious diseases, sample preparation is considered as the key step and remains a real technical challenge. Finding new methods for extraction of micro-organisms from a complex biological sample remains a major challenge prior to pathogen detection and analysis. This paper reports a new technique for capturing and isolating micro-organisms from a complex sample. To achieve the segregation of pathogens and blood cells, dielectrophoretic forces applied to bioparticles previously subjected to an osmotic shock are successfully implemented within a dedicated microfluidic device. Our device involves an electrode array of interdigitated electrodes, coated with an insulating layer, to minimize electrochemical reactions with the electrolyte and to enable long-time use. The electric field intensity inside the device is optimized, considering the insulating layer, for a given frequency bandwidth, enabling the separation of bioparticles by dielectrophoretic forces. Our predictions are based on analytical models, consistent with numerical simulations (using COMSOL Multiphysics) and correlated to experimental results. The method and device have been shown to extract different types of micro-organisms spiked in a blood cell sample. We strongly believe that this new separation approach may open the way towards a simple device for pathogen extraction from blood and more generally complex samples, with potential advantages of genericness and simplicity.


Assuntos
Células Sanguíneas/microbiologia , Candida albicans/isolamento & purificação , Eletroforese , Escherichia coli/isolamento & purificação , Técnicas Analíticas Microfluídicas/métodos , Eletrodos , Eritrócitos/microbiologia , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Pressão Osmótica
10.
J Biomed Opt ; 16(5): 057001, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21639579

RESUMO

We report a new technique to measure coagulation dynamics on whole-blood samples. The method relies on the analysis of the speckle figure resulting from a whole-blood sample mixed with coagulation reagent and introduced in a thin chamber illuminated with a coherent light. A dynamic study of the speckle reveals a typical behavior due to coagulation. We compare our measured coagulation times to a reference method obtained in a medical laboratory.


Assuntos
Coagulação Sanguínea/fisiologia , Lasers , Fotometria/instrumentação , Refratometria/instrumentação , Tempo de Coagulação do Sangue Total/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Luz , Espalhamento de Radiação
11.
Biomed Microdevices ; 12(3): 485-97, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20204703

RESUMO

This paper presents promising microfluidic devices designed for continuous and passive extraction of plasma from whole human blood. These designs are based on red cells lateral migration and the resulting cell-free layer locally expanded by geometric singularities such as an enlargement of the channel or a cavity adjacent to the channel. After an explanation of flow patterns, different tests are described that confirm the advantages of both proposed singularities, providing a 1.5 and 2X increase in extraction yield compared to a reference device, for 1:20 diluted blood at 100 microL/min. Devices have also been successively optimized, with extraction yields up to 17.8%, and biologically validated for plasma extraction, with no protein loss or denaturation, no hemolysis and with excellent cell purity. Finally, the dilution effect has been experimentally investigated.


Assuntos
Coleta de Amostras Sanguíneas/instrumentação , Sistema Livre de Células/química , Análise de Injeção de Fluxo/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Plasma/química , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos
12.
PLoS One ; 5(2): e9238, 2010 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-20169076

RESUMO

BACKGROUND: Tissue invasion or tissue infiltration are clinical behaviors of a poor-prognosis subset of meningiomas. We carried out proteomic analyses of tissue extracts to discover new markers to accurately distinguish between infiltrative and noninfiltrative meningiomas. METHODOLOGY/PRINCIPAL FINDINGS: Protein lysates of 64 different tissue samples (including two brain-invasive and 32 infiltrative tumors) were submitted to SELDI-TOF mass spectrometric analysis. Mass profiles were used to build up both unsupervised and supervised hierarchical clustering. One marker was found at high levels in noninvasive and noninfiltrative tumors and appeared to be a discriminative marker for clustering infiltrative and/or invasive meningiomas versus noninvasive meningiomas in two distinct subsets. Sensitivity and specificity were 86.7% and 100%, respectively. This marker was purified and identified as a multiphosphorylated form of vimentin, a cytoskeletal protein expressed in meningiomas. CONCLUSIONS/SIGNIFICANCE: Specific forms of vimentin can be surrogate molecular indicators of the invasive/infiltrative phenotype in tumors.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias Meníngeas/metabolismo , Meningioma/metabolismo , Vimentina/metabolismo , Adulto , Idoso , Biomarcadores Tumorais/química , Análise por Conglomerados , Feminino , Humanos , Masculino , Neoplasias Meníngeas/classificação , Neoplasias Meníngeas/diagnóstico , Meningioma/classificação , Meningioma/diagnóstico , Pessoa de Meia-Idade , Peso Molecular , Fosforilação , Proteômica/métodos , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Vimentina/química
13.
Mol Med ; 14(7-8): 383-94, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18496584

RESUMO

Hypertension represents one of the main risk factors for vascular diseases. Genetic susceptibility may influence the rate of its development and the associated vascular remodeling. To explore markers of hypertension-related morbidity, we have used surface-enhanced laser desorption/ionization time-of-flight (SELDI-TOF) mass spectrometry to study changes in proteins released by the aorta of two rat strains with different susceptibilities to hypertension. Fischer and Brown Norway (BN) rats were divided into a control group and a group receiving low-dose N(Omega)-nitro-L-arginine methyl ester (L-NAME), a hypertensive drug, interfering with endothelial function. In spite of a significant elevation of blood pressure in both strains in response to L-NAME, BN rats exhibited a lower vascular remodeling in response to hypertension. Proteomic analysis of secreted aortic proteins by SELDI-TOF MS allowed detection of four mass-to-charge ratio (m/z) peaks whose corresponding proteins were identified as ubiquitin, smooth muscle (SM) 22alpha, thymosin beta4, and C-terminal fragment of filamin A, differentially secreted in Fischer rats in response to L-NAME. We have confirmed a strain-dependent difference in susceptibility to L-NAME-induced hypertension between BN and Fischer rats. The greater susceptibility of Fischer rats is associated with aortic wall hypertrophic remodeling, reflected by increased aortic secretion of four identified biomarkers. Similar variations in one of them, SM22alpha, also were observed in plasma, suggesting that this marker could be used to assess vascular damage induced by hypertension.


Assuntos
Biomarcadores/análise , Hipertensão/fisiopatologia , Proteômica , Artéria Renal/fisiopatologia , Animais , Aorta/metabolismo , Aorta/patologia , Aorta/fisiopatologia , Biomarcadores/metabolismo , Endotélio Vascular/metabolismo , Endotélio Vascular/patologia , Endotélio Vascular/fisiopatologia , Hemodinâmica , Hipertensão/induzido quimicamente , Hipertensão/metabolismo , Hipertensão/patologia , NG-Nitroarginina Metil Éster , Inibidor 1 de Ativador de Plasminogênio/metabolismo , Proteoma/análise , Proteoma/metabolismo , Proteômica/métodos , Ratos , Ratos Endogâmicos BN , Ratos Endogâmicos F344 , Regeneração/fisiologia , Artéria Renal/metabolismo , Artéria Renal/patologia , Análise de Sobrevida
14.
Proteomics ; 6(23): 6288-99, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17072908

RESUMO

The troponin (Tn) complex is composed of troponin T, troponin C and troponin I. The cardiac isoform of TnI (cTnI) is modified and released in blood of patients with cardiovascular diseases as a heterogeneous mixture of free, complexed and posttranslationally modified forms. With the aim to determine later, whether specific forms of cTnI could be associated with the different pathologies leading to cTnI release, the cTnI forms present in the plasma from 64 patients with acute myocardial infarction (AMI) have been analysed by SELDI-TOF MS using anti-TnI mAbs coupled to PS20 ProteinChips arrays. Upfront immunoaffinity enrichment using anti-cTnI 19C7 mAb allowed us to detect cTnI and bis-phosphorylated cTnI in 11/12 and 9/12 analyses respectively, as well as truncated cTnI in plasma with concentration of cTnI as low as 8 ng/mL. Cardiac troponin C (cTnC) and covalent TnIC complex were also found in pools of plasma with higher concentrations of cTnI. MAb 19C7-affinity SELDI-TOF MS analysis performed after immunopurification of one pool of AMI plasma with anti-free cTnI, anti-cTnC, and anti-phosphorylated cTnI mAbs indicated that intact and bis-phosphorylated cTnI were mostly under the free form. Besides, a 18 718 m/z peak could correspond to a truncated phosphorylated form initially complexed with cTnC.


Assuntos
Infarto do Miocárdio/sangue , Isoformas de Proteínas/análise , Troponina I/análise , Western Blotting , Humanos , Fosforilação , Análise Serial de Proteínas , Isoformas de Proteínas/imunologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Troponina I/metabolismo
15.
Hepatology ; 41(1): 40-7, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15690480

RESUMO

Surface-enhanced laser desorption ionization time-of-flight mass spectrometry (SELDI-TOF MS) is a proteomic technique that enables the profiling of proteins present in any biological material studied. We used this approach to identify new biomarkers of hepatocellular carcinoma (HCC) in the sera of patients with cirrhosis. Sera from 82 patients with cirrhosis, either without (n = 38) or with (n = 44) HCC, were analyzed by SELDI-TOF MS, and the results of the two groups were compared. The most efficient protein peaks leading to discrimination of patients with HCC were selected (receiver operative characteristic curves). The highest-scoring peak combination was established in a first group of serum samples (multinomial regression) and was tested in an independent group. The protein corresponding to the highest discrimination was purified and characterized further. The intensity of 30 protein peaks significantly differed between cirrhotic patients with and without HCC. An algorithm including the six highest-scoring peaks allowed correct classification (presence or absence of HCC) of 92.5% of patients in the test sample set and 90% in the validation sample set. The highest discriminating peak (8900 Da) was purified further and was characterized as the C-terminal part of the V10 fragment of vitronectin. An in vitro study suggested that the increase of the 8900-Da fragment in the serum of patients with HCC may proceed from the cleavage of native vitronectin with metalloproteases, a family of enzymes whose activity is enhanced in HCC. In conclusion, global protein profiling is an efficient approach that enabled us to identify a catalytic fragment ofvitronectin as a new serum marker of HCC in patients with chronic liver diseases.


Assuntos
Biomarcadores Tumorais/sangue , Proteínas Sanguíneas/análise , Carcinoma Hepatocelular/sangue , Cirrose Hepática/sangue , Neoplasias Hepáticas/sangue , Idoso , Sequência de Aminoácidos , Proteínas Sanguíneas/química , Carcinoma Hepatocelular/complicações , Doença Crônica , Feminino , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/patologia , Cirrose Hepática/fisiopatologia , Neoplasias Hepáticas/complicações , Masculino , Metaloproteinase 2 da Matriz/metabolismo , Pessoa de Meia-Idade , Dados de Sequência Molecular , Peso Molecular , Fragmentos de Peptídeos/sangue , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/genética , Estudos Retrospectivos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Vitronectina/sangue , Vitronectina/química , Vitronectina/genética , Vitronectina/metabolismo
16.
Biochem Biophys Res Commun ; 325(3): 1021-9, 2004 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-15541391

RESUMO

The identification of protein components in complex networks of co-regulators responsible for the modulation of proliferation versus differentiation modes of cell growth is a major problem. We use a combination of surface enhanced laser desorption/ionization mass spectrometry, surface plasmon resonance coupled to electrospray mass spectrometry, and immunoelectromobility shift assays to identify members of the MAX/MAD family binding to a specific DNA silencer fragment involved in the regulation of transcription for the human T-cell receptor Vbeta2.2 segment. We also identify the cofactors mSin3 and N-CoR known to interact with histone deacetylases. Inhibition of deacetylase activity in Jurkat cells prevented transcription inhibitor complex formation at the Vbeta2.2 segment, suggesting that this is either directly or indirectly dependent on the presence of HDACs.


Assuntos
Proteínas de Ligação a DNA/metabolismo , Histona Desacetilases/metabolismo , Receptores de Antígenos de Linfócitos T alfa-beta/metabolismo , Proteínas Repressoras/metabolismo , Regulação para Baixo/genética , Regulação da Expressão Gênica/genética , Histona Desacetilases/genética , Humanos , Células Jurkat , Regiões Promotoras Genéticas/genética , Transcrição Gênica/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA