Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanomaterials (Basel) ; 14(2)2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38276744

RESUMO

Field-effect transistor (FET) biosensors can be used to measure the charge information carried by biomolecules. However, insurmountable hysteresis in the long-term and large-range transfer characteristic curve exists and affects the measurements. Noise signal, caused by the interference coefficient of external factors, may destroy the quantitative analysis of trace targets in complex biological systems. In this report, a "rectified signal" in the output characteristic curve, instead of the "absolute value signal" in the transfer characteristic curve, is obtained and analyzed to solve these problems. The proposed asymmetric Schottky barrier-generated MoS2/WTe2 FET biosensor achieved a 105 rectified signal, sufficient reliability and stability (maintained for 60 days), ultra-sensitive detection (10 aM) of the Down syndrome-related DYRK1A gene, and excellent specificity in base recognition. This biosensor with a response range of 10 aM-100 pM has significant application potential in the screening and rapid diagnosis of Down syndrome.

2.
J Ethnopharmacol ; 156: 125-9, 2014 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-25193683

RESUMO

ETHNOPHARMACOLOGICAL RELEVANCE: Escin, a natural mixture of triterpene saponins, is commonly utilized for the treatment of chronic venous insufficiency, hemorrhoids, inflammation and edema. Escin Ia is the chief active ingredient in escin and plays key role in mediating its pharmacological effects. Adequate pharmacokinetic data are essential for proper application of escin agent in clinical practice. However, pharmacokinetic properties of escin Ia are still poorly understood and this conflicts with the growing use of escin agent over the years. The goal of this study is to investigate the pharmacokinetic behavior of escin Ia in rats after low, medium and high-dose intravenous administration. MATERIALS AND METHODS: Wistar rats were divided into 3 groups (n=6 per group) and escin Ia was administered via the caudal vein at doses of 0.5, 1.0 and 2.0 mg/kg, respectively. Subsequently, the concentrations of escin Ia and its metabolite isoescin Ia, a positional isomer of escin Ia, in rats׳ plasma were measured by an established liquid chromatography tandem mass spectrometry (LC-MS/MS) method at various time points following the administration of the drug. Main pharmacokinetic parameters were calculated by non-compartmental analysis using the TopFit 2.0 software package (Thomae GmbH, Germany). RESULTS: After intravenous administration, the Cmax and AUC of escin Ia increased in a dose-proportional manner at the dose of 0.5 mg/kg and 1.0 mg/kg, while increased in a more than dose-proportional manner at the doses of 1.0 mg/kg and 2.0 mg/kg. The t1/2 was significantly longer with increased intravenous doses, while other parameters such as CL and Vd also exhibit disagreement among three doses. Taken together, our data showed dose-dependent pharmacokinetic profile of escin Ia in rats after intravenous administration at the doses of 0.5-2.0 mg/kg. After intravenous administration, escin Ia was rapidly and extensively converted to isoescin Ia. CONCLUSIONS: The results suggested dose-dependent pharmacokinetics of escin Ia at the doses of 0.5-2.0 mg/kg after intravenous administration. Escin Ia is isomerized to isoescin Ia rapidly and extensively regardless of the doses.


Assuntos
Escina/farmacocinética , Animais , Área Sob a Curva , Cromatografia Líquida , Relação Dose-Resposta a Droga , Feminino , Meia-Vida , Masculino , Taxa de Depuração Metabólica , Ratos , Ratos Wistar , Espectrometria de Massas em Tandem
3.
J Ethnopharmacol ; 151(2): 839-45, 2014 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-24334163

RESUMO

ETHNOPHARMACOLOGICAL RELEVANCE: Adequate pharmacokinetic data of escin, a natural mixture of triterpene saponins used for the treatment of chronic venous insufficiency, hemorrhoids, inflammation and edema, is of special interest in view of the growing use of escin agent in clinical medicine. However, pharmacokinetic data are inadequate to support their clinical indication. Escin Ib and isoescin Ib are the chief active ingredients in escin, pharmacokinetics study of them would be helpful for improving the practice of escin application. The goals of this study are to determine the plasma concentration of escin Ib and isoescin Ib using an established liquid chromatography tandem mass spectrometry (LC-MS/MS) method and to compare the pharmacokinetics and bioavailability of these compounds in rats when administered as pure isomers or as sodium escinate. MATERIALS AND METHODS: Five groups of Wistar rats (n=6 per group) were treated with either an intravenous (IV) dose (2.78mg/kg) of sodium escinate (corresponding to 0.5mg/kg of escin Ib and 0.5mg/kg of isoescin Ib), an IV dose (0.5mg/kg) and an oral dose (4mg/kg) of pure escin Ib or isoescin Ib. The concentrations of escin Ib and isoescin Ib in rat plasma were determined by LC-MS/MS at various times following the administration of the drugs. The pharmacokinetic parameters were estimated by a non-compartmental analysis and then subjected to statistical analysis. RESULTS: The administration of sodium escinate, which contains the two isomers, gave rise to higher terminal phase half-life (t1/2) and mean residence time (MRT) values for both escin Ib and isoescin Ib compared to the corresponding compounds administered alone. The absorption of escin Ib and isoescin Ib was very poor, with the oral bioavailability (F) values of <2% observed for both compounds. The two compounds were found to isomerize in vivo, wherein the conversion of escin Ib to isoescin Ib was much easier than that of isoescin Ib to escin Ib. CONCLUSIONS: A comparison of the pharmacokinetics of escin Ib and isoescin Ib administered alone and together in rats suggests that the administration of herbal preparations of escin in a clinical setting may result in a longer duration of action than the administration of each isomer alone. The interconversion of escin Ib and isoescin Ib when administered alone indicates that the administration of one isomer results in exposure to the other isomer.


Assuntos
Escina/farmacocinética , Administração Intravenosa , Administração Oral , Animais , Escina/sangue , Feminino , Masculino , Ratos , Ratos Wistar
4.
Exp Ther Med ; 5(2): 626-630, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23404219

RESUMO

A rapid, sensitive and specific analytical method based on high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the determination of thalidomide concentration in human plasma. The analyte and internal standard were extracted by liquid-liquid extraction with ether-dichloromethane (3:2, v/v) and separated on a TC-C(18) column using methanol-10 mM ammonium acetate-formic acid (60:40:0.04, v/v/v) as the mobile phase at a flow rate of 0.9 ml/min. The detection was performed using an API 4000 triple quadrupole mass spectrometer in the positive electrospray ionization (ESI) mode and completed within 3.0 min. The multiple reaction monitoring (MRM) transitions were m/z 259.1→84.0 for the analyte and m/z 195.9→138.9 for temozolomide. The calibration curve exhibited a linear dynamic range of 2-1500 ng/ml (r>0.9991). The intra-and inter-day precisions (as relative standard deviation; RSD) were 6.8-13.5% and 4.3-5.0% respectively and the accuracy (as relative error; RE) was 2.0-3.5%. The recoveries and matrix effects were satisfactory in all the biological matrices examined. This method was successfully used in a pharmacokinetic study of thalidomide in healthy male volunteers receiving an oral administration of a 200-mg dose.

5.
J Ethnopharmacol ; 139(1): 201-6, 2012 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-22094055

RESUMO

ETHNOPHARMACOLOGICAL RELEVANCE: Escin Ia and isoescin Ia have been traditionally used clinically as the chief active ingredients of escin, a major triterpene saponin isolated from horse chestnut (Aesculus hippocastanum) seeds for the treatment of chronic venous insufficiency, hemorrhoids, inflammation and edema. AIM OF THE STUDY: To establish a sensitive LC-MS/MS method and investigate the pharmacokinetic properties of escin Ia and isoescin Ia in rats and the pharmacokinetics difference of sodium escinate with pure escin Ia and isoescin Ia. The absolute bioavailability of escin Ia and isoescin Ia and the bidirectional interconversion of them in vivo were also scarcely reported. MATERIALS AND METHODS: Wister rats were administrated an intravenous (i.v.) dose (1.7 mg/kg) of sodium escinate (corresponding to 0.5mg/kg of escin Ia and 0.5mg/kg of isoescin Ia, respectively) and an i.v. dose (0.5mg/kg) or oral dose (4mg/kg) of pure escin Ia or isoescin Ia, respectively. At different time points, the concentrations of escin Ia and isoescin Ia in rat plasma were determined by LC-MS/MS method. Main pharmacokinetic parameters including t(1/2), MRT, CL, V(d), AUC and F were estimated by non-compartmental analysis using the TopFit 2.0 software package (Thomae GmbH, Germany) and statistical analysis was performed using the Student's t-test with P<0.05 as the level of significance. RESULTS: After administration of sodium escinate, the t(1/2) and MRT values for both escin Ia and isoescin Ia were larger than corresponding values for the compounds given alone. Absorption of escin Ia and isoescin Ia was very low with F values both <0.25%. Escin Ia and isoescin Ia were found to form the other isomer in vivo with the conversion of escin Ia to isoescin Ia being much extensive than from isoescin Ia to escin Ia. CONCLUSION: Comparison of the pharmacokinetics of escin Ia and isoescin Ia given alone and together in rat suggest that administration of herbal preparations of escin for clinical use may provide longer duration of action than administration of single isomers. The interconversion of escin Ia and isoescin Ia when given alone indicates that administration of one isomer leads to exposure to the other.


Assuntos
Aesculus , Escina/farmacocinética , Extratos Vegetais/farmacocinética , Administração Oral , Aesculus/química , Animais , Área Sob a Curva , Disponibilidade Biológica , Cromatografia Líquida , Escina/análogos & derivados , Escina/sangue , Escina/isolamento & purificação , Feminino , Injeções Intravenosas , Masculino , Extratos Vegetais/sangue , Ratos , Ratos Wistar , Sementes/química , Espectrometria de Massas em Tandem
6.
Talanta ; 86: 221-6, 2011 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-22063534

RESUMO

A method has been developed and validated for the quantitative determination of flumorph residues in vegetables and fruits using dimoxystrobin as internal standard (I.S.) by high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The conversion rule between flumorph (Z) and flumorph (E) has been studied through sunlight photodegradation test of flumorph. Flumorph and I.S. were extracted with ethyl acetate and preconcentrated by Oasis HLB cartridge. Qualitative and quantitative detection for the analytes were carried out under the multiple reaction monitoring (MRM) in positive ionization mode after chromatography separation on a Symmetry C(18) (150 mm × 2.1 mm × 3.5 µm) column. Studies at fortification level of 0.05-25 µg kg(-1) gave mean recoveries from 77.6 to 92.9% for flumorph, with relative standard deviation (R.S.D.) ≤ 8.7%. The limit of quantification (LOQ, S/N=10) was 0.05 µg kg(-1). The proposed method was successfully applied on real samples from different kinds of vegetables and fruits. Flumorph residues were detected in 70% of the samples analyzed and the highest concentration level was 1.83 µg kg(-1) in tomato sample.


Assuntos
Frutas/química , Morfolinas/análise , Resíduos de Praguicidas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Verduras/química , Cromatografia Líquida de Alta Pressão/métodos , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/normas , Espectrometria de Massas em Tandem/normas
7.
J Chromatogr Sci ; 49(2): 89-93, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21223631

RESUMO

A rapid and sensitive LC-MS-MS method for the quantitation of sertraline in human plasma was developed and validated. Sertraline and the internal standard, telmisartan, were cleaned up by protein precipitation from 100 µL of plasma sample, and analyzed on a TC-C18 column (5 µm, 150 × 4.6 mm i.d.) using 70% acetonitrile and 30% 10 mM ammonium acetate (0.1% formic acid) as mobile phase. The method was demonstrated to be linear from 0.1 ng/mL to 50 ng/mL with the lower limit of quantitation of 0.1 ng/mL. Intra- and inter-day precision were below 4.40% and 3.55%. Recoveries of sertraline at low, medium, and high levels were 88.0 ± 2.3%, 88.2 ± 1.9%, and 90.0 ± 2.0%, respectively. The method was successfully applied to a bioequivalence study of sertraline after a single oral administration of 50 mg sertraline hydrochloride tablets.


Assuntos
Cromatografia Líquida/métodos , Sertralina/sangue , Espectrometria de Massas em Tandem/métodos , Adulto , Benzimidazóis/análise , Benzimidazóis/química , Benzoatos/análise , Benzoatos/química , Humanos , Modelos Lineares , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sertralina/química , Sertralina/farmacocinética , Telmisartan
8.
Xenobiotica ; 41(4): 340-8, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21182394

RESUMO

Felbinac trometamol (trishydroxymethylaminomethane 4-biphenylacetate) is a new water-soluble salt of felbinac currently undergoing clinical evaluation as an intravenous (i.v.) formulation for the treatment of severe post-operative pain. This article reports the pharmacokinetics of felbinac after i.v. administration of felbinac trometamol in Sprague-Dawley rats. The maximum plasma concentration (C(0)) and area under the plasma concentration-time curve (AUC) of felbinac administered at doses of 3.36, 8.40 and 21.0 mg/kg felbinac trometamol increased linearly with dose. Felbinac was highly protein bound (~95%) at plasma concentrations up to 75 µg/ml and extensively metabolized with only small amounts being excreted unchanged in urine (0.318%), feces (0.530%) and bile (0.465%). 4'-Hydroxyfelbinac was the principal metabolite in urine, feces and bile together with felbinac glucuronide, 4'-hydroxyfelbinac glucuronide and sulfate. The majority of the administered dose was excreted in urine (63.6%) mostly as 4'-hydroxyfelbinac. Total drug in urine and feces accounted for about 72% of the dose. It would appear that felbinac trometamol has the potential to replace lipid-based NSAID formulations and progress to clinical evaluation.


Assuntos
Anti-Inflamatórios não Esteroides/farmacocinética , Fenilacetatos/farmacocinética , Trometamina/farmacocinética , Animais , Anti-Inflamatórios não Esteroides/administração & dosagem , Anti-Inflamatórios não Esteroides/metabolismo , Bile/metabolismo , Fezes/química , Feminino , Injeções Intravenosas , Masculino , Fenilacetatos/administração & dosagem , Fenilacetatos/metabolismo , Ratos , Ratos Sprague-Dawley , Trometamina/administração & dosagem
9.
J Pharm Biomed Anal ; 52(1): 149-54, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20079994

RESUMO

A rapid and sensitive method for the simultaneous quantitation of hydrochlorothiazide (HCT) and metoprolol (MET) in human plasma based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated. MS/MS detection involved switching the electrospray ionization (ESI) mode during chromatography from negative to detect HCT and its internal standard (I.S.) 5-bromouracil to positive to detect MET and its I.S. tramadol. Sample preparation by liquid-liquid extraction with diethyl ether-dichloromethane (60:40, v/v) was followed by chromatography on a Venusil MP-C18 column using methanol-ammonium acetate (10mM)-formic acid (pH 3.4) (50:50:0.05, v/v/v) at a flow rate of 0.8mL/min. The method was linear in the concentration range 3-1000ng/mL for both HCT and MET using 100microL human plasma. Intra- and inter-day precisions (as relative standard deviation) for HCT were 2.9-3.9% and 3.9-4.7%, respectively and for MET were 2.4-4.1% and 4.7-6.2%, respectively. Accuracies (as relative error) were +/-3.8% and +/-2.6% for HCT and MET, respectively. The assay was successfully applied to a pharmacokinetic study involving a single oral dose of a combination tablet (25mg HCT, 50mg MET) in healthy volunteers.


Assuntos
Anti-Hipertensivos/sangue , Cromatografia Líquida , Hidroclorotiazida/sangue , Metoprolol/sangue , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Administração Oral , Anti-Hipertensivos/administração & dosagem , Anti-Hipertensivos/farmacocinética , Calibragem , Cromatografia Líquida/normas , Combinação de Medicamentos , Humanos , Hidroclorotiazida/administração & dosagem , Hidroclorotiazida/farmacocinética , Concentração de Íons de Hidrogênio , Masculino , Metoprolol/administração & dosagem , Metoprolol/farmacocinética , Variações Dependentes do Observador , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/normas , Comprimidos , Espectrometria de Massas em Tandem/normas
10.
J Pharm Biomed Anal ; 50(2): 171-4, 2009 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-19395215

RESUMO

A rapid and sensitive method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the determination of octahydroaminoacridine in human plasma using tramadol as internal standard (I.S.). Sample preparation involved pH adjustment with sodium carbonate followed by solvent extraction with dichloromethane:ethyl ether (40:60, v/v). Chromatographic separation was achieved on a Venusil MP-C18 column (5 microm, 100 mm x 4.6mm) using acetonitrile:10mM ammonium acetate:formic acid (30:70:1, v/v/v) as mobile phase. Detection utilized an API 4000 system operated in the positive ion mode with multiple reaction monitoring of the analyte at m/z 203.1-->175.1 and of the I.S. at m/z 264.1-->58.0. The method was linear in the range 0.01-10 ng/ml with a lower limit of quantitation of 0.0 1ng/ml. Intra- and inter-day precisions measured as relative standard deviation were <3.15% and <5.01%, respectively. The method was successfully applied to a pharmacokinetic study involving oral administration of a tablet containing 4 mg octahydroaminoacridine succinate to healthy volunteers. Pharmacokinetic parameters for octahydroaminoacridine include C(max) 1.19+/-0.53 ng/ml, T(max) 0.77+/-0.17 h, AUC(0-t) 3.42+/-1.01 ng h/ml and t(1/2) 2.89+/-0.56 h.


Assuntos
Aminacrina/análogos & derivados , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Aminacrina/análise , Humanos , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA