Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
JACC Case Rep ; 29(10): 102320, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38601848

RESUMO

Novel dedicated devices allow transcatheter treatment of pure aortic regurgitation (AR). The JenaValve Trilogy Heart Valve System was introduced as the first dedicated and on-label AR transcatheter aortic valve replacement system, implementing a locator-based and calcium-independent anchoring mechanism. Here, we present the first-in-human transcatheter aortic valve replacement for pure AR via a transcaval access in a patient with prohibitive alternative arterial accesses.

2.
J Clin Med ; 13(2)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38276098

RESUMO

Transcatheter aortic valve implantation (TAVI) is now well established as the treatment of choice for patients with native aortic valve stenosis who are high or intermediate risk for surgical aortic valve replacement. Recent data has also supported the use of TAVI in patients at low surgical risk and also in anatomical subsets that were previously felt to be contra-indicated including bicuspid aortic valves and aortic regurgitation. With advancements and refinements in procedural techniques, the application of this technology has now been further expanded to include the management of degenerated bioprosthesis. After the demonstration of feasibility and safety in the management of degenerated aortic bioprosthetic valves, mitral and tricuspid bioprosthetic valve treatment is now also well-established and provides an attractive alternative to performing redo surgery. In this review, we appraise the latest clinical evidence and highlight procedural considerations when utilising TAVI technology in the management of degenerated aortic, mitral or tricuspid prosthesis.

4.
Catheter Cardiovasc Interv ; 102(7): 1401-1405, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37694603

RESUMO

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
8.
Front Cardiovasc Med ; 10: 1091309, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37255703

RESUMO

The prevalence of mitral (MR) and tricuspid regurgitation (TR), especially in heart failure (HF) populations, is high. However, the distinct role of atrioventricular valve diseases in HF, whether they are merely indicators of disease status or rather independent contributors in a vicious disease cycle, is still not fully understood. For decades, tricuspid regurgitation (TR) was considered an innocent bystander subsequent to other heart or lung pathologies, thus, not needing dedicated treatment. Recent increasing awareness towards the role of atrioventricular valve diseases has revealed that MR and TR are, in fact, independent predictors of outcome in HF, thus, warranting attention in the HF treatment algorithm. This awareness arose, especially, with the development of minimally invasive transcatheter solutions providing new treatment options, which can also be used for patients considered as having increased surgical risk. However, outcomes of such transcatheter treatments have, in part, been sub-optimal and likely influenced by the status of the concomitant HF disease. Thus, this review aims to summarize data on the current understanding regarding the role of MR and TR in HF, how HF impacts outcomes of transcatheter MR and TR interventions, and how the understanding of this relationship might help to identify patients that benefit most from these therapies, which have proven to be lifesaving in properly selected candidates.

9.
JACC Case Rep ; 12: 101776, 2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37091051

RESUMO

Patients with tricuspid regurgitation are often referred late in their disease course and present with volume overload, which is a detrimental factor leading to right-sided chamber dilatation and dysfunction. Treatment of volume overload can 1) improve patient functional status; 2) avoid repeated invasive examinations; and 3) establish eligibility for transcatheter tricuspid intervention. (Level of Difficulty: Intermediate.).

14.
Eur Heart J Suppl ; 24(Suppl C): C233-C242, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35602251

RESUMO

Recent evidence has shown that transcatheter heart valve (THV) anchoring in bicuspid aortic valve (BAV) patients occurs at the level of the raphe, known as the LIRA (Level of Implantation at the RAphe) plane. Our previous work in a cohort of 20 patients has shown that the delineation of the perimeter and device sizing at this level is associated with optimal procedural outcome. The goals of this study were to confirm the feasibility of this method, evaluate 30-day outcomes of LIRA sizing in a larger cohort of patients, assess interobserver variation and reproducibility of this sizing methodology, and analyse the interaction of LIRA-sized prostheses with the surrounding anatomy. The LIRA sizing method was applied to consecutive patients presenting to our centre with raphe-type BAV disease between November 2018 and October 2021. Supra-annular self-expanding THVs were sized based on baseline CT scan perimeters at the LIRA plane and the virtual basal ring. In cases where there was discrepancy between the two measurements, the plane with the smallest perimeter was considered the reference for prosthesis sizing. Post-procedural device success, defined according to Valve Academic Research Consortium-2 (VARC-2) criteria, was evaluated in the overall cohort. A total of 50 patients (mean age 80 ± 6 years, 70% male) with raphe-type BAV disease underwent transcatheter aortic valve replacement (TAVR) using different THV prostheses. The LIRA plane method appeared to be highly successful (100% VARC-2 device success) with no procedural mortality, no valve migration, no moderate-severe paravalvular leak, and low transprosthetic gradients (residual mean gradient 8.2 ± 3.4 mmHg). There were no strokes, no in-hospital or 30-day mortality, and an incidence of in-hospital pacemaker implantation of 10%. Furthermore, measurement of the LIRA plane perimeter was highly reproducible between observers (r = 0.980; P < 0.001) and predictive of the post-procedural prosthetic valve perimeter on CT scanning (r = 0.981; P < 0.001). We confirm the feasibility of supra-annular sizing using the LIRA method in a large cohort of patients with high procedural success and good clinical outcomes at 30 days. Application of the LIRA method optimizes THV prosthesis sizing in patients with raphe-type BAV disease.

15.
J Invasive Cardiol ; 34(3): E226-E236, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35235529

RESUMO

BACKGROUND: Nonagenarians represent only a small proportion of patients included in large transcatheter aortic valve replacement (TAVR) trials, but will become a relevant future population in need of treatment due to demographic change. Thus, this study sought to evaluate outcomes of TAVR for the treatment of severe aortic stenosis (AS) in nonagenarian patients. METHODS: We screened Medline/Pubmed for studies that stated specific outcomes for nonagenarians undergoing TAVR. A weighted meta-analysis was conducted, calculating pooled estimate rates using a binary random-effects model for dichotomous variables, and comparing non-dichotomous outcomes with a continuous random-effects model. RESULTS: Data from 23 studies including 16,094 nonagenarians were merged; 53.4% were women. Despite reasonable rates of comorbidities, Society of Thoracic Surgeons mortality risk score was 10.2 ± 5.4. Pooled estimate rate of procedural success was 94.1% (95% confidence interval [CI], 91.7-96.6), with major vascular complications occurring in 6.3% (95% CI, 2.7-9.8) and at least moderate postprocedural paravalvular leak in 7.5% (95% CI, 4.4-10.6). The rate of periprocedural stroke or transient ischemic attack was 2.6% (95% CI, 2.0-3.2). At 30 days, the pooled estimate of mortality was 6.1% (95% CI, 4.7-7.4) and a permanent pacemaker was implanted in 12.6% (95% CI, 7.6-17.6). After 1 year, the mortality rate was 20.5% (95% CI, 15.9-25.1). CONCLUSION: TAVR in nonagenarians is an effective and safe procedure, with encouraging outcomes given the general life expectancy of these patients. Currently, only selected nonagenarians are undergoing TAVR, but their number will grow as life expectancy continues to increase in the developed world. Specific research to identify ideal candidates and techniques in this cohort is needed.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Nonagenários , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
16.
EuroIntervention ; 18(2): e160-e168, 2022 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-34916177

RESUMO

BACKGROUND: New ischaemic brain lesions on magnetic resonance imaging (MRI) are reported in up to 86% of patients after transcatheter edge-to-edge repair of the mitral valve (TEER-MV). Knowledge of the exact procedural step(s) that carry the highest risk for cerebral embolisation may help to further improve the procedure. AIMS: The aim of this study was to identify the procedural step(s) that are associated with an increased risk of cerebral embolisation during TEER-MV with the MitraClip system. Furthermore, the risk of overt stroke and silent brain ischaemia after TEER-MV was assessed. METHODS: In this prospective, pre-specified observational study, all patients underwent continuous transcranial Doppler examination during TEER-MV to detect microembolic signals (MES). MES were assigned to specific procedural steps: (1) transseptal puncture and placement of the guide, (2) advancing and adjustment of the clip in the left atrium, (3) device interaction with the MV, and (4) removal of the clip delivery system and the guide. Neurological examination using the National Institutes of Health Stroke Scale (NIHSS) and cerebral MRI were performed before and after TEER-MV. RESULTS: Fifty-four patients were included. The number of MES differed significantly between the procedural steps with the highest numbers observed during device interaction with the MV. Mild neurological deterioration (NIHSS ≤3) occurred in 9/54 patients. New ischaemic lesions were detected in 21/24 patients who underwent MRI. Larger infarct volume was significantly associated with neurological deterioration. CONCLUSIONS: Cerebral embolisation is immanent to TEER-MV and predominantly occurs during device interaction with the MV. Improvements to the procedure may focus on this procedural step.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Acidente Vascular Cerebral , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
17.
JACC Asia ; 2(7): 865-868, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36713756
19.
Interv Cardiol ; 16: e07, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34035831

RESUMO

Over the past decade, several transcatheter devices have been developed to address the treatment of severe mitral regurgitation (MR) in patients at high surgical risk, mainly aimed at repairing the native mitral valve (MV). MV repair devices have recently been shown to have high efficacy and safety. However, to replicate promising trial results, specific anatomical and pathophysiological criteria have to be met and operators need a high level of experience. As yet, the longer-term durability of transcatheter MV repair remains unknown. Transcatheter MV replacement (TMVR) might be a treatment option able to target various anatomies, reliably abolish MR, and foster ease of use with a standardised implantation protocol. This review presents upcoming TMVR devices and available data and discusses how TMVR might further advance the field of transcatheter treatment of MR.

20.
Int J Cardiol ; 330: 12-14, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33571564

RESUMO

BACKGROUND: Despite international revascularisation guidelines strongly recommending functional assessment of coronary artery stenosis using pressure-wire derived indices, the adoption rate of coronary physiology remains low. METHODS: An online questionnaire was designed to evaluate behavioural determinants impacting the adoption rate of coronary physiology. Factor analysis was performed to combine multiple items of a common behavioural domain into one explanatory factor. Regression analysis was performed to evaluate the influence of resulting factors on the variance of the coronary physiology adoption rate. Additionally, the influence of experience, demographics and provider structures was assessed. RESULTS: 104 interventional cardiologists, from 21 countries, completed the questionnaire. Mean adoption rate of coronary physiology was 26.9%. Regression analysis revealed that factors ease-of-use (Coefficient = 0.58, p = 0.01), financial and/or time constraints (Coefficient = -0.22, p = 0.01) and knowledge about guideline recommendations (Coefficient = 0.21, p = 0.06) had the greatest influence on coronary physiology adoption rate variance (R2 = 0.3, p < 0.001), with ease-of-use and guideline recommendations positively influencing greater uptake and constraints influencing lesser uptake of adoption of coronary physiology. CONCLUSION: Ease-of-use, financial and/or time constraints, and knowledge about guideline recommendations were the most relevant behavioural factors impacting the adoption rate of coronary physiology. Ease-of-use was identified as the most influential factor, highlighting the importance of cardiac catheterisation laboratory teams being adequately trained to perform coronary physiology assessment seamlessly.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Cateterismo Cardíaco , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...