1.
J Interv Cardiol ; 2022: 9926423, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35832534

RESUMO

Objectives: This study was conducted to determine why heart teams recommended transcatheter aortic valve replacement (TAVR) versus surgical AVR (SAVR) for patients at low predicted risk of mortality (PROM) and describe outcomes of these cases. Background: Historically, referral to TAVR was based predominately on the Society of Thoracic Surgeons (STS) risk model's PROM >3%. In selected cases, heart teams had latitude to overrule these scores. The clinical reasons and outcomes for these cases are unclear. Methods: Retrospective data were gathered for all TAVR and SAVR cases conducted by 9 hospitals between 2013 and 2017. Results: Cases included TAVR patients with STS PROM >3% (n = 2,711) and ≤3% (n = 415) and SAVR with STS PROM ≤3% (n = 1,438). Leading reasons for recommending TAVR in the PROM ≤3% group were frailty (57%), hostile chest (22%), severe lung disease (16%), and morbid obesity (13%), and 44% of cases had multiple reasons. Most postoperative and 30-day outcomes were similar between TAVR groups, but the STS PROM ≤3% group had a one-day shorter length of stay (2.5 ± 3.4 vs. 3.5 ± 4.7 days; p ≤ 0.001) and higher one-year survival (91.6% vs. 86.0%, p=0.002). In patients with STS PROM ≤3%, 30-day mortality was higher for TAVR versus SAVR (2.0% vs. 0.6%; p < 0.001). Conclusions: Heart teams recommended TAVR in patients with STS PROM ≤3% primarily due to frailty, hostile chest, severe lung disease, and/or morbid obesity. Similar postoperative outcomes between these patients and those with STS PROM >3% suggest that decisions to overrule STS PROM ≤3% were merited and may have reduced SAVR 30-day mortality rate.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Implante de Prótese de Valva Cardíaca , Pneumopatias , Obesidade Mórbida , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Fragilidade/etiologia , Fragilidade/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pneumopatias/etiologia , Pneumopatias/cirurgia , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
J Invasive Cardiol ; 34(6): E433-E441, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35593541

RESUMO

BACKGROUND: Patients with small aortic annuli (SAA) are prone to higher post-transcatheter aortic valve replacement (TAVR) transvalvular gradients and development of prosthesis-patient mismatch (PPM). In many patients with SAA, the choice of TAVR valve commonly involves choosing between the 26-mm Medtronic Evolut 2 (ME26) or the 23-mm Edwards Sapien 3 valve (ES23). We compared echocardiographic and clinical outcomes in patients with SAA undergoing TAVR with either valve. METHODS: We queried the Providence St. Joseph Health Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry database for patients undergoing TAVR with either the ES23 or ME26 between July 2015 and December 2018 at 11 hospitals. Post-TAVR echocardiographic and clinical results in-hospital, at 1 month, and at 1 year were examined. High gradient (HG) was defined as mean gradient (MG) ≥20 mm Hg. RESULTS: We identified 1162 patients with SAA undergoing TAVR with either the ME26 (n = 233) or ES23 valve (n = 929). Baseline characteristics between groups were similar. At 1 month, the ME26 was associated with a lower MG than the ES23 (7.7 ± 4.7 mm Hg vs 13.1 ± 4.9 mm Hg; P<.001) and moderate or severe PPM (11% and 3% vs 27% and 13%; P<.001). Occurrence of HG at 1 year was lower with the ME26 valve vs the ES23 valve (0% vs 15%; P<.001). In-hospital and follow-up clinical outcomes to 1 year were similar for both groups. CONCLUSION: TAVR in SAA with the ME26 is associated with lower incidence of HG or PPM compared with the ES23. While clinical outcomes at 1 year were similar, the long-term implications of these findings remain unknown.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...